5 Ways To Fix Open Ground Receptacles. With code references and visuals! How to fix an open ground.

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ธ.ค. 2024

ความคิดเห็น • 23

  • @abelferia1
    @abelferia1 2 ปีที่แล้ว +6

    God Bless.
    Hello there brother in faith for life. Just reaching out to thank you and bless you for all you've done with the electrical community. I my self just passed the master's exam thanks to your dedication and passion for the electrical coaching, am 60 years old and believe me when I tell you the lord has given you a precious gift. Again keep up doing what you do many blessings for you and your family.

  • @noconsentgiven
    @noconsentgiven ปีที่แล้ว +2

    My day got better when I came to your channel❤️. Thanks Coach and God bless👍!!

  • @Jesusbeliever1
    @Jesusbeliever1 ปีที่แล้ว

    I learned some good information on this short, to the point and very understandable information. Thanks a lot.

  • @Gruntled2001
    @Gruntled2001 2 ปีที่แล้ว +2

    Coach, thank you for sharing your knowledge with us 🤝

  • @mikekares-b8q
    @mikekares-b8q 3 หลายเดือนก่อน

    Many Older Homes had those Old two prong outlets and Old style Knob and Tube wires.

  • @chrispate2788
    @chrispate2788 2 ปีที่แล้ว +1

    Great explanation coach 👍

  • @anthonyelectric6045
    @anthonyelectric6045 2 ปีที่แล้ว +3

    Hey coach I ran into this situation a long time ago when we didn’t have these many code or equipment options. Snaking new wire and #12 wire all over the place uhh. Great explanation as always 👍

  • @gregsettle9725
    @gregsettle9725 10 หลายเดือนก่อน +2

    Good video. There are so many opinions on the use of GFCI outlets to fix missing ground. Some say one downstream, some say all outlets must be GFCI. Who to believe?

  • @thomaswatson6960
    @thomaswatson6960 2 ปีที่แล้ว +1

    great work

  • @Sparky-ww5re
    @Sparky-ww5re 2 ปีที่แล้ว +1

    Helpful video. While adding GFCI protection does not protect sensitive electronics, like your 50 inch smart TV plugged into a surge protector, it does provide personal shock protection, so it's important to note that while Code does allow this practice, it's not quite as good as having a true ground.

  • @jmichel70
    @jmichel70 ปีที่แล้ว

    Thank you,

  • @martinfishersings
    @martinfishersings 2 หลายเดือนก่อน

    If you install an individual GFCI, it will still light up as an open ground, correct?

  • @vince6829
    @vince6829 2 ปีที่แล้ว +1

    Thank you for sharing your knowledge.
    Question: the second way to address a missing ground (rewire the location), involves running a new stretch of romex (e.g. 14-2), correct? Could it simply involve running a single green ground wire from the breaker box to the receptacle?

  • @liberaltears1714
    @liberaltears1714 ปีที่แล้ว

    If I installed exterior outlets (because I don’t have any, built in the 50’s) could I drill a small hole through my old metal boxes and block house to run a short ground wire from the inside to the new outdoor outlets?

  • @88PeteZa
    @88PeteZa ปีที่แล้ว

    I have a garage with only one outlet in it. The outlet is not grounded. Would it be safe to go to earth with a physical ground outside via grounding spike?

    • @ElectricalCodeCoach
      @ElectricalCodeCoach  ปีที่แล้ว

      I would contact a qualified licensed electrician!!

    • @88PeteZa
      @88PeteZa ปีที่แล้ว

      @@ElectricalCodeCoach absolutely

  • @wiley0714
    @wiley0714 2 ปีที่แล้ว +1

    You buy a pack of pigtails. And then you connect the ground wire to the receptacle, and you connect the other end with a twist nut to the neutral.
    Can you sell the house and smile!

    • @johnrueb2257
      @johnrueb2257 2 ปีที่แล้ว +8

      See above, that is illegal and unethical. DO NOT DO THIS.