AC Blown Fuses - How to test them and why they blow

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ก.ค. 2024
  • How to test AC Blown Fuses and why they blow? We show how a low voltage fuse works to protect the low voltage circuit in am air conditioner. How to use a volt and ohm meter to test and how to inspect the system for the cause.
    Check out our 208V vs 240V video here: • How is 208 volts diffe...
    Read all the tech tips, take the quizzes
    and find our handy calculators at www.hvacrschool.com/

ความคิดเห็น • 34

  • @kennyjohnson4411
    @kennyjohnson4411 3 ปีที่แล้ว +1

    Awesome video!

  • @randallshawver3
    @randallshawver3 ปีที่แล้ว +3

    Never worked on HVAC before, but through this video, I was able to diagnose and fix the issue. 3 wires were so old they had Roman numerals on them. Replaced them and done! Thanks!

  • @b-2466
    @b-2466 3 ปีที่แล้ว +4

    I'm about to finish my second semester of school for hvac. This channel helps so much.

  • @loganguzman6856
    @loganguzman6856 2 ปีที่แล้ว +2

    Awesome video best I seen! Congratulations and thank you for helping us out!

  • @TeslaBoy123
    @TeslaBoy123 2 ปีที่แล้ว +1

    Thanks for sharing this 👍

  • @nhattuygiaithiensaunguyen9885
    @nhattuygiaithiensaunguyen9885 2 ปีที่แล้ว +1

    Thank you so much your video help me learned a lot

  • @joejesko7410
    @joejesko7410 3 ปีที่แล้ว +5

    Shorted wires are probably the most common, but I had a system recently that was blowing fuses because the contactor was bad. Very low resistance (ohms), so basically it was shorting out. Easy fix once problem was diagnosed.

    • @austrianpainterhidingfromt5920
      @austrianpainterhidingfromt5920 2 ปีที่แล้ว

      I'm learning the tech side after having been an installer, and that just happened to me last week. I opened up the air handler to find a pile of blown fuses laying in there, apparently is was a chronic issue. When I put a new fuse in, the relay in the AHU made this strange clicking sound, I thought maybe the relay was bad, replaced it, same thing. I ended up checking the contactor on the condenser and it read only .2 ohms, replaced that and everything started up fine.
      I don't know why the AHU relay was clicking but my guess is that sporadic low voltage from that contactor beginning to short was clicking it on and off.

  • @baitcasterdisaster8981
    @baitcasterdisaster8981 3 ปีที่แล้ว +6

    I’ve ran into a low voltage fuse that was blowing intermittently and it was quite humbling. I had 2 call backs before I ended up pulling a new wire to the outdoor unit and I haven’t been back since. Each time I visually inspected everything and isolated all low voltage circuits but couldn’t find it so I put a new fuse in and when I left it was working. Then a few days later I’d get a call back it was very frustrating

  • @arielhernandez2911
    @arielhernandez2911 3 ปีที่แล้ว

    This is great man

  • @nakiapringley5391
    @nakiapringley5391 2 ปีที่แล้ว

    Awesome video 💯💯💯💯💯

  • @paisaconstructiondavid1964
    @paisaconstructiondavid1964 หลายเดือนก่อน

    Muchas gracias, if I understood correctly an E fuse is 3.5 amp?

  • @ncooty
    @ncooty 5 หลายเดือนก่อน

    @3:05: No need to remove the fuse to check continuity. Just touch the probes to the top contacts.

  • @michaelcostello6991
    @michaelcostello6991 3 ปีที่แล้ว

    Is low voltage usually AC and not DC ? Do we come across DC often. Thanks for great video

  • @turbo12v
    @turbo12v 3 ปีที่แล้ว

    Hi
    I have a new heat pump installed 2 yrs ago (Carrier)
    I didn’t pay attention until this past winter season in FL,that my unit doesn’t turn outside on heat mode,just the heating strip in the air handler unit.
    It’s a heat pump ! I look at the reversing valve on condenser to make sure they install the correct unit.
    But it won’t reverse anything at all! I think it’s the thermostat,but I would like to get a second opinion to see what else besides the thermostat I can start looking at. Thanks

    • @repeatman
      @repeatman 9 หลายเดือนก่อน

      I would check and see if the reversing valve wire is hooked up. If it's not on some units it won't reverse the flow of refrigerant.

  • @jmac213stuff
    @jmac213stuff 3 ปีที่แล้ว

    What the proper amp/volt rating for 120 and 208/240 v systems? Are they all rated for 24v?

  • @geekedbot5784
    @geekedbot5784 3 ปีที่แล้ว +1

    Why would the transformer blow before the fuse ? One of the outdoor fan wires came out & I put it back in place. Once I turned the unit on the transformer was done. Why ?

  • @jandshatton331
    @jandshatton331 3 ปีที่แล้ว +1

    I just saw this. The last tech didn't put the capacitor back in the clamp and left it dangling. Eventually it made contact with the wall and shorted the fuse out

  • @migosmadeira9892
    @migosmadeira9892 3 ปีที่แล้ว

    I have a 35 yr old Bryant air handler , there’s no circuit board and I can’t find a 3 amp fuse. What happend was I bypass the thermosthat with a paperclip, in the proccess , I think I shorted something the AC won’t run. If I can’t find a fuse , any suggestions which part is shorted? The AC was working before I did the bypass.

    • @jeffreylamelas8102
      @jeffreylamelas8102 3 ปีที่แล้ว

      Yes please call your local HVAC company

    • @jasonkinney8129
      @jasonkinney8129 3 ปีที่แล้ว

      Call a tech.

    • @josephfarrow2685
      @josephfarrow2685 3 ปีที่แล้ว +4

      Those old air handlers did not have fuses. You probably shorted the transformer

    • @texasterry4414
      @texasterry4414 3 ปีที่แล้ว +1

      Did you use a plastic paper clip? That’s crucial...and definitely a red one.

  • @monteglover4133
    @monteglover4133 3 ปีที่แล้ว

    Be extremely careful when testing voltages to ground you can often get improper voltage readings

  • @chuckdearruda6271
    @chuckdearruda6271 3 ปีที่แล้ว

    👍🏽

  • @andresperez-wc8ty
    @andresperez-wc8ty 3 ปีที่แล้ว

    Shorted coils are a source of shorts, i always check

  • @donnierobertson3088
    @donnierobertson3088 3 ปีที่แล้ว

    Ok

  • @pathannold6150
    @pathannold6150 2 ปีที่แล้ว

    Heat blowing cold o

  • @danmartens1282
    @danmartens1282 3 ปีที่แล้ว

    Can a thermostat with batteries installed and c wire connected cause fuse to blow.?

  • @samboherring3673
    @samboherring3673 3 ปีที่แล้ว

    Just put a bigger one in

  • @teamaztecas763
    @teamaztecas763 2 ปีที่แล้ว

    To confusing. You should keep it simple

  • @nakiapringley5391
    @nakiapringley5391 2 ปีที่แล้ว

    Awesome video 💯💯💯💯💯💯