AC Blown Fuses - How to test them and why they blow
ฝัง
- เผยแพร่เมื่อ 17 ก.ค. 2024
- How to test AC Blown Fuses and why they blow? We show how a low voltage fuse works to protect the low voltage circuit in am air conditioner. How to use a volt and ohm meter to test and how to inspect the system for the cause.
Check out our 208V vs 240V video here: • How is 208 volts diffe...
Read all the tech tips, take the quizzes
and find our handy calculators at www.hvacrschool.com/
Awesome video!
Never worked on HVAC before, but through this video, I was able to diagnose and fix the issue. 3 wires were so old they had Roman numerals on them. Replaced them and done! Thanks!
I'm about to finish my second semester of school for hvac. This channel helps so much.
Awesome video best I seen! Congratulations and thank you for helping us out!
Thanks for sharing this 👍
Thank you so much your video help me learned a lot
Shorted wires are probably the most common, but I had a system recently that was blowing fuses because the contactor was bad. Very low resistance (ohms), so basically it was shorting out. Easy fix once problem was diagnosed.
I'm learning the tech side after having been an installer, and that just happened to me last week. I opened up the air handler to find a pile of blown fuses laying in there, apparently is was a chronic issue. When I put a new fuse in, the relay in the AHU made this strange clicking sound, I thought maybe the relay was bad, replaced it, same thing. I ended up checking the contactor on the condenser and it read only .2 ohms, replaced that and everything started up fine.
I don't know why the AHU relay was clicking but my guess is that sporadic low voltage from that contactor beginning to short was clicking it on and off.
I’ve ran into a low voltage fuse that was blowing intermittently and it was quite humbling. I had 2 call backs before I ended up pulling a new wire to the outdoor unit and I haven’t been back since. Each time I visually inspected everything and isolated all low voltage circuits but couldn’t find it so I put a new fuse in and when I left it was working. Then a few days later I’d get a call back it was very frustrating
This is great man
Awesome video 💯💯💯💯💯
Muchas gracias, if I understood correctly an E fuse is 3.5 amp?
@3:05: No need to remove the fuse to check continuity. Just touch the probes to the top contacts.
Is low voltage usually AC and not DC ? Do we come across DC often. Thanks for great video
Hi
I have a new heat pump installed 2 yrs ago (Carrier)
I didn’t pay attention until this past winter season in FL,that my unit doesn’t turn outside on heat mode,just the heating strip in the air handler unit.
It’s a heat pump ! I look at the reversing valve on condenser to make sure they install the correct unit.
But it won’t reverse anything at all! I think it’s the thermostat,but I would like to get a second opinion to see what else besides the thermostat I can start looking at. Thanks
I would check and see if the reversing valve wire is hooked up. If it's not on some units it won't reverse the flow of refrigerant.
What the proper amp/volt rating for 120 and 208/240 v systems? Are they all rated for 24v?
Why would the transformer blow before the fuse ? One of the outdoor fan wires came out & I put it back in place. Once I turned the unit on the transformer was done. Why ?
I just saw this. The last tech didn't put the capacitor back in the clamp and left it dangling. Eventually it made contact with the wall and shorted the fuse out
I have a 35 yr old Bryant air handler , there’s no circuit board and I can’t find a 3 amp fuse. What happend was I bypass the thermosthat with a paperclip, in the proccess , I think I shorted something the AC won’t run. If I can’t find a fuse , any suggestions which part is shorted? The AC was working before I did the bypass.
Yes please call your local HVAC company
Call a tech.
Those old air handlers did not have fuses. You probably shorted the transformer
Did you use a plastic paper clip? That’s crucial...and definitely a red one.
Be extremely careful when testing voltages to ground you can often get improper voltage readings
👍🏽
Shorted coils are a source of shorts, i always check
Ok
Heat blowing cold o
Can a thermostat with batteries installed and c wire connected cause fuse to blow.?
No
Just put a bigger one in
To confusing. You should keep it simple
Awesome video 💯💯💯💯💯💯