Installing Central Lock/Keyless Entry to Toyota Vios

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Part 1. Central Locking System installed in Toyota Vios bought from LAZADA s.lazada.com.p...

ความคิดเห็น • 28

  • @espiratoguieb7244
    @espiratoguieb7244 2 ปีที่แล้ว +1

    Sir,Salamat sa pagtuturo,pati ako nalilito dahil cable den ung sa akin..ngaun alam ko na.

  • @Scott-NCC1701
    @Scott-NCC1701 3 ปีที่แล้ว +1

    Great work! Making it work with a cable control is difficult. Thanks for sharing!

  • @tnamen1307
    @tnamen1307 3 ปีที่แล้ว

    Sir, one thing very danger about double operations of hazard warning light and key operations.
    Activate the hazard warning switch and closed all doors.
    Now, press the lock and unlock buttons one after another, the turn signal bulb will be fused and damaged.

  • @markanthonysantos4782
    @markanthonysantos4782 2 ปีที่แล้ว

    Good am po idol, ask lang po paano po sa vios 2019 xe ang installation ng keyless? Thanks po

  • @donmeneses1265
    @donmeneses1265 ปีที่แล้ว

    Bos paano po magconnect sa flasher/hazard yung remote?

  • @maureenromerovlog5506
    @maureenromerovlog5506 3 ปีที่แล้ว +1

    Sir na co-convert din po ba ang manual window into power window? batman vios din thanks

    • @chomytuideas1784
      @chomytuideas1784  3 ปีที่แล้ว +1

      yes sir

    • @tnamen1307
      @tnamen1307 3 ปีที่แล้ว

      @@chomytuideas1784 Sir, one thing very danger about double operations of hazard warning light and key operations.
      Activate the hazard warning switch and closed all doors.
      Now, press the lock and unlock buttons one after another, the turn signal bulb will be fused and damaged.

    • @chomytuideas1784
      @chomytuideas1784  3 ปีที่แล้ว +1

      @@tnamen1307 the operation is still safe sir considering all supplies from hazard and key operation are all positive. Moreover, positive signal from the module has a rectifier diode before it reaches to the signal light bulbs

    • @tnamen1307
      @tnamen1307 3 ปีที่แล้ว

      @@chomytuideas1784 when hazard is activated, turn signal bulbs are coming on.
      Now, you operate the 4 buttons on the key with all doors closed, the bulbs will be fused out. Why? Because you have 2 sources of current meeting at the same load..
      1. Coming from hazard switch to bulbs.
      2. Coming from the remote control module to the same bulbs.

    • @chomytuideas1784
      @chomytuideas1784  3 ปีที่แล้ว +1

      @@tnamen1307 yes, you're right. 2 sources from the same load. but remember that those 2 sources came from one battery that has 12v output. even if they were activated at the sime time, the operation is still safe

  • @sprintermototv9750
    @sprintermototv9750 ปีที่แล้ว

    Boss ano ba kulay ng possitve at negative wire sa sasakyan at saan makikita?

    • @chomytuideas1784
      @chomytuideas1784  ปีที่แล้ว

      Dpende boss. Pero usually red sa positive. black sa negative

  • @rondchin8782
    @rondchin8782 2 ปีที่แล้ว

    Sir magkano pakabit sau at san loaction mo?

  • @RobertoGutierrez-u7o
    @RobertoGutierrez-u7o ปีที่แล้ว

    Sir location nyo po? At mag jano mag pa install

  • @RobertoGutierrez-u7o
    @RobertoGutierrez-u7o ปีที่แล้ว

    Sir location nyo po