Trane Txv conversion kit from a short orifice header assembly

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 ต.ค. 2024
  • Trane Txv conversion

ความคิดเห็น • 104

  • @thepharaoh7565
    @thepharaoh7565 3 ปีที่แล้ว +2

    Excellent job, the way of making a hole in the suction line for the external equalizer while it was under pressure to keep it clean is awesome. Thank you

  • @wechselrichterschaltungen
    @wechselrichterschaltungen 7 ปีที่แล้ว +1

    Hello Ulises,
    See it from germany, super work and beautifully described what they just do. Please keep it up.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      walter f. Thank you I appreciate it.

  • @joeshearer1247
    @joeshearer1247 7 ปีที่แล้ว +1

    I've never seen a liquid line drier with 2 schraders like that. Awesome

    • @joeshearer1247
      @joeshearer1247 7 ปีที่แล้ว +1

      If you don't want shavings you can start the drill bit until almost through and then use a nail to finish it

    • @joeshearer1247
      @joeshearer1247 7 ปีที่แล้ว +1

      That other compressor looks like it's flooding

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Joe Shearer good eye. That thing has sweat stains on it lol. I was gonna mention that in the video. It was overcharged by a bit.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Joe Shearer yeah. That's pretty cool to see pressure drop.

  • @arturofromtucson6262
    @arturofromtucson6262 7 ปีที่แล้ว +1

    Professional.. hope I never encounter that but if I do I know what to do now. thanks dude

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Arturo from Tucson 👍🏼. It’s actually easier than it looks.

  • @rubenv929
    @rubenv929 7 ปีที่แล้ว +1

    great job and video. I like the case set up for your hoses.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Ruben V thanks. Me too. It's the Appion case.

  • @rookierefrigeration4357
    @rookierefrigeration4357 5 ปีที่แล้ว +1

    You are my idol. I want to be like you when I grow up 😍😍😍

  • @AgentFunk
    @AgentFunk 7 ปีที่แล้ว +5

    fantastic video! Learned a lot!

  • @FireandFrostHVAC
    @FireandFrostHVAC 5 ปีที่แล้ว

    This is one of my favourite videos, thank you.

  • @AKHVAC
    @AKHVAC 7 ปีที่แล้ว +1

    This is awesome man. It's a pain but it you pull the panel off the opposite side on the header assembly (it's a huge panel) I found 3 or 4 U bends frosted up during a freeze test. Glad I checked, otherwise I would have just quoted the header replacement (which was restricted too) instead of a who new evap which was what they really needed.

    • @AKHVAC
      @AKHVAC 7 ปีที่แล้ว +1

      Definitely gonna try to go with a TXV next time instead of replacing header assembly

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      AKGreaves HVAC the txv kit it's actually pretty easy. I would go for it.

  • @Wisdomoftheair
    @Wisdomoftheair 7 ปีที่แล้ว +1

    We just changed a compressor on a 5 ton single stage. On start up I had correct pressures and temps, but over the weekend, it changed, by Monday we got called back. The head was 200 psi R-22, and the lo-side 100. SL 65, LL 89.
    I called tech support, and he had me block off the cond. fan, to see if pressure, and amps would go up. It only went up to 225 psi, and the lo-side went to 140 psi, and the amps never changed. He condemned the compressor. I got on FB, HVAC school group, and some guys were saying this acutrol was the likely culprit, but I figured they would only restrict, not bypass?

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Chris waessil yeah it seems like a issue with the compressor. You can also disconnect the blower to see if the suction pressure drops below normal. It's not the acutrol short orifice metering devices. It's a just a fixed piston in each tube. It would not raise your suction pressure.

    • @xraybravo7180
      @xraybravo7180 9 วันที่ผ่านมา

      Whsts the difference between sccurltrol and piston ?​@@UlisesPalacios

  • @texasstarniles5
    @texasstarniles5 7 ปีที่แล้ว +1

    Nice Work Mr Palacios there is a lot of this type of Metering Devices out there not working well

  • @eva-wp7vo
    @eva-wp7vo 7 ปีที่แล้ว

    Great work just got a ICP unit with the same orifice set up

  • @jonhvac
    @jonhvac 7 ปีที่แล้ว +4

    Copper plating on the schrader? You and Eric M should do collab vid together...our heads will explode with knowledge💣💥
    Great vid Ulises!

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Jon HVAC lol 😂 thanks man. that would be fun.

    • @jonhvac
      @jonhvac 7 ปีที่แล้ว +1

      Ulises Palacios Can I ask you about the channel art on your home page?

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Jon HVAC sure. It's actually my reversing valve for my unit lol. I used the flir one thermal to take the photo.

    • @jonhvac
      @jonhvac 7 ปีที่แล้ว

      Ulises Palacios I see that but, I'm referring to the picture on your channel home page.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Jon HVAC is it the iManifold screen?

  • @anthonnnyy
    @anthonnnyy 5 ปีที่แล้ว

    Nice job,wish you all the best

  • @benkuxhouse787
    @benkuxhouse787 6 ปีที่แล้ว

    I spoke with Trane tech support about this issue he also recommended putting on a crankcase heater if one is not on there and you have the original orifices. If carrier doesn't make it like that if you can get the right tonnage of TXV get like that it should work on the carriers to

  • @jimbola77
    @jimbola77 7 ปีที่แล้ว

    thank's palacios for sharing Excellent work!!!!!!

  • @WinsteadClimateControl
    @WinsteadClimateControl 7 ปีที่แล้ว +1

    This looks to be fairly easy to do.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Lynn Winstead it's super easy. easier than replacing a compressor.

  • @KungFuMaintenance
    @KungFuMaintenance 7 ปีที่แล้ว +1

    Nicely done!!!

  • @a11ten071
    @a11ten071 3 ปีที่แล้ว

    Great job tnx a bunch for sharing.

  • @mrcrux213
    @mrcrux213 6 ปีที่แล้ว

    From 1000 micron firts decayed test and should not pass 2000 microns. If so put nitrogen to 15 psi just to absorb humidity for 15minutes. Repeat the process until you pass the decay test for the 1000 microns them you take it to 500 microns and for a period of 10 minutes should not pass over a 1000 microns if so repeat the process. If you can not achieve the decay test most probably the valcores or the system has a leak. Don't panic and remember you got to 500 microns and most of the tech do not used a micron gauges and nobody is there to see if you did it. Laughs and charges the system After all it is not a refrigeration system just AC.
    Thanks for the video man. I have been seeing so many videos of how to do a vacuum that I got okay when I do not achieve the decay test.

  • @alessichris07
    @alessichris07 7 ปีที่แล้ว +1

    Top notch work

  • @cosmodog1803
    @cosmodog1803 2 ปีที่แล้ว

    You really know your craft, was problem low evap pressure?

  • @NorCal-refrigeration
    @NorCal-refrigeration 7 ปีที่แล้ว +2

    Nice video.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Nor-Cal Refrigeration & H.V.A.C thanks man

  • @capitolrefrigerationheatin7501
    @capitolrefrigerationheatin7501 7 ปีที่แล้ว +1

    I thought there is a way of clearing the short orifice tubes by heating them and passing nitrogen through them, I believe Eric M has a video showing how to do it.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Capitol Refrigeration,Heating,and Cooling there is but it's not guaranteed to work. Trane actually sales an additive called mjx but they say it's for 410a only. The junk really sticks to those little orifices.

  • @justin0957
    @justin0957 7 ปีที่แล้ว +2

    I don't wear safety glasses I want to make sure I see the shavings fly out into my eyes

  • @juanmarquez8
    @juanmarquez8 7 ปีที่แล้ว +1

    great video thanks

  • @ZuffaLtdDanaWhite
    @ZuffaLtdDanaWhite 7 ปีที่แล้ว +1

    Equalizer should be after the sensing bulb.

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      ZuffaLtdDanaWhite in the installation instructions it says to mount the sensing bulb right after the equalizer tube

  • @rodgraff1782
    @rodgraff1782 5 ปีที่แล้ว +1

    If the oil is broken down enough to plug up offices, due to running high discharge temperatures, shouldn’t you have dumped the compressor and changed the oil? Why is the other compressor so rusty around the shell?

    • @UlisesPalacios
      @UlisesPalacios  5 ปีที่แล้ว

      Rod Graff all good questions . Probably. The other compressor was flooding back. They had bad airflow due to bad ductwork and the wall around the units didn’t help during the summer. Especially since they never cleaned the coils.

  • @RobHVAC
    @RobHVAC 7 ปีที่แล้ว +1

    Great vid

  • @aircooledtx
    @aircooledtx 7 ปีที่แล้ว +1

    Good txv change-out. HATE/header orifices .Good job, Ulises ..Get back to work.

  • @hookedup9424
    @hookedup9424 ปีที่แล้ว +1

    You wouldn’t happen to remember the part number for this txt kit you used.

    • @UlisesPalacios
      @UlisesPalacios  ปีที่แล้ว

      Is it an r22 system? If so what’s the model number

    • @hookedup9424
      @hookedup9424 ปีที่แล้ว +1

      @@UlisesPalacios YHC092A3EMA1V0000000000

    • @hookedup9424
      @hookedup9424 ปีที่แล้ว

      Yes it's r22 7.5 ton.

    • @UlisesPalacios
      @UlisesPalacios  ปีที่แล้ว

      @@hookedup9424 what’s your email

    • @redred5389
      @redred5389 2 หลายเดือนก่อน

      What’s the part number?

  • @gene-khvacr
    @gene-khvacr 7 ปีที่แล้ว

    good job great vid isnt there a restrictor( on the original ) at end of cap tube on the header would you drill or braze it out and How long did it take you to finish up total time approximately .

  • @syedbasheer8210
    @syedbasheer8210 3 ปีที่แล้ว

    Good job🤩

  • @xraybravo7180
    @xraybravo7180 2 หลายเดือนก่อน

    How did you size your txv and cap tubes did trane give you this ? How can i get this for any unit or unit im working on different tonnage and acutra tubes i have 25 ton trane with 16 orifices.

  • @islamkloub4491
    @islamkloub4491 3 ปีที่แล้ว

    All you have to do it's get your torches tip closer to the 7 inch copper and I guarantee you it's going to make a hole in it get within a butt half an inch grommet tip to pipe

  • @jacobscyphers6322
    @jacobscyphers6322 7 ปีที่แล้ว +1

    Great job. Doing my first one of these tomorrow. May I ask why you chose to not use the bells on the distributor tubes. Just easier to braze?

    • @UlisesPalacios
      @UlisesPalacios  7 ปีที่แล้ว

      Jacob Scyphers awesome. It's pretty easy. The instructions say to cut them off and deburr them. Then stick them in about 1 inch and crimp the pipe around them carefully. What's your email. I'll send you a PDF

    • @jacobscyphers6322
      @jacobscyphers6322 7 ปีที่แล้ว

      Ulises Palacios . That would be great thank you sir. Jacobscyphers@gmail.

    • @nicolasmartinez1693
      @nicolasmartinez1693 6 ปีที่แล้ว

      Do you mind sending me the email as well.

  • @marster37
    @marster37 4 ปีที่แล้ว

    More importantly, what is the part number from Trane for the conversion?

  • @nayemislam1417
    @nayemislam1417 2 ปีที่แล้ว

    What size this capillary Sir

  • @dimensionxtoys
    @dimensionxtoys 2 ปีที่แล้ว

    How do you calculate what size txv for the header?

  • @bouchikhilarbi3641
    @bouchikhilarbi3641 3 ปีที่แล้ว

    👍👍

  • @joshuapoche5137
    @joshuapoche5137 6 ปีที่แล้ว

    Man ive done a ton of these kits and none of mine have ever come with the ends flared out like that.

  • @Saqmadiq69
    @Saqmadiq69 6 ปีที่แล้ว

    did you have to adjust txv for your superheat?

  • @monteiroair4259
    @monteiroair4259 5 ปีที่แล้ว

    Great video. Does Trane and Carrier actually have these kits available for this conversion?

    • @UlisesPalacios
      @UlisesPalacios  5 ปีที่แล้ว

      monteiro air yes they do make a kit. Thank you

    • @nickmiller4544
      @nickmiller4544 3 ปีที่แล้ว

      Our local carrier store say they don't have the conversion kit, haven't try Trane yet

  • @usmanchaudry7167
    @usmanchaudry7167 5 ปีที่แล้ว

    Thank u sir

  • @brucemoine9749
    @brucemoine9749 5 ปีที่แล้ว

    So this is a really cool kit. Where did you get it ?

    • @UlisesPalacios
      @UlisesPalacios  5 ปีที่แล้ว

      Bruce Moine just go to your local trane and ask for it. They will hook you up with the correct kit

    • @brucemoine9749
      @brucemoine9749 5 ปีที่แล้ว

      @@UlisesPalacios I did. They say it doesn't exist. Factory just refrerences the header. You have a part number ?

    • @UlisesPalacios
      @UlisesPalacios  5 ปีที่แล้ว

      Bruce Moine whats the model number of the unit. Send me your email. I will forward you some information that I got from trane. It has the part numbers.

  • @squirtlehvac8962
    @squirtlehvac8962 5 ปีที่แล้ว

    What were your pressures sh and sc while it was running restricted?
    Thanks

    • @UlisesPalacios
      @UlisesPalacios  5 ปีที่แล้ว +1

      Squirtle Hvac I don’t remember exactly but I had a high superheat with a low suction pressure. And high subcooling

  • @thomasmann1527
    @thomasmann1527 2 ปีที่แล้ว

    what the part number!!?!?

  • @throttlebottle5906
    @throttlebottle5906 7 ปีที่แล้ว +1

    multi-tube nightmare :)

  • @juliusshalom9099
    @juliusshalom9099 5 ปีที่แล้ว

    Who TF will dislike this video.

  • @juanjover9977
    @juanjover9977 7 ปีที่แล้ว +1

    What is the name of the little lube for the gage?

  • @himanshujoshi3071
    @himanshujoshi3071 5 ปีที่แล้ว

    Nice but you are not leakage test

  • @notanewbie1718
    @notanewbie1718 7 ปีที่แล้ว +1

    Dirty condenser coils cause these kind of problems.