Eccentric Welded Connection Out of Plane | Design of Steel Structures

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ม.ค. 2025

ความคิดเห็น • 26

  • @mirakhtaryousuf6582
    @mirakhtaryousuf6582 2 ปีที่แล้ว +1

    Out of all the questions on eccentric loading from various channels , I found this best

  • @satyamhr
    @satyamhr 6 ปีที่แล้ว +2

    One doubt here. In sk duggal book( limit state designof steel structure 2nd edition) page no. 702 and 703 they have given entirely different thing. Please can you look at it and also see example 14.9 and 14.10

  • @furqansayyed813
    @furqansayyed813 2 ปีที่แล้ว

    bro i just wanted to ask,the way we divide the length of weld on either side when designing in plane member, can we divide this required weld ht in the same manner??plz answer

  • @mohdsaquibazam3786
    @mohdsaquibazam3786 4 ปีที่แล้ว +1

    Thanks

    • @beoptimistic5853
      @beoptimistic5853 4 ปีที่แล้ว

      th-cam.com/video/vFDMaHQ4kW8/w-d-xo.html ...💐

  • @deiwakarsingh2508
    @deiwakarsingh2508 7 ปีที่แล้ว

    Hello sir, Hydrology is not as important as surveying..... So plz consider about surveying...
    by the way, you know very well what topic should be covered first better than us...

  • @Durgeshkumar-ip1ls
    @Durgeshkumar-ip1ls 5 ปีที่แล้ว

    Thank you sir

  • @priyanshupatel2282
    @priyanshupatel2282 5 ปีที่แล้ว

    Awesome

  • @rigneshchandra6031
    @rigneshchandra6031 4 ปีที่แล้ว

    When minimum throat thickness(t) should be 3 mm as you said as per the code .. then why we have taken it as 2.8 mm??

  • @sakarjoshi5705
    @sakarjoshi5705 5 ปีที่แล้ว

    What if the load is inclined ? How is the design done?

  • @foohong3235
    @foohong3235 6 ปีที่แล้ว

    if the beam is welded to the column without any plate, may i know how should i calculate for the eccentricity? The loading on beam is UDL.

  • @MustafaAhmed-mb7hu
    @MustafaAhmed-mb7hu 5 ปีที่แล้ว

    When is cleat angle used for connection??? what is the procedure to design using cleat angle??

  • @jyotiacademy2022
    @jyotiacademy2022 5 ปีที่แล้ว

    #CORRECTION IS NEEDED.#
    This has to be separately dealt for FILLET WELD and BUTT WELD.

  • @SanjayKumar-fg8wx
    @SanjayKumar-fg8wx 5 ปีที่แล้ว

    Minimum size of weld is governed by thickness of thicker plate ..

  • @kumareshbiswas5798
    @kumareshbiswas5798 7 ปีที่แล้ว

    sir next steel
    video kab upload hoga... i am waiting sir

  • @shrirammeena228
    @shrirammeena228 7 ปีที่แล้ว

    sir hydrology when...

    • @APSEDUVERSE
      @APSEDUVERSE  7 ปีที่แล้ว

      After steel, environment 1 and then hydrology

  • @lakshyasehgal1465
    @lakshyasehgal1465 5 ปีที่แล้ว +2

    Even shit is more clearer than this writing.

  • @civilenggmcq7926
    @civilenggmcq7926 7 ปีที่แล้ว

    here t will be thickness or throat thickness plz tell me clearly
    and in lecture 11 part2 u r taking 300KN as factored load ie not multiplyed in solution with1.5

    • @APSEDUVERSE
      @APSEDUVERSE  7 ปีที่แล้ว

      Here t is throat thickness. In example also I have multiplied thickness with 0.7. In lecture 11 part 2, In question it was given as factored load. I did not write the question that is why this confusion came. For future problems if you find in question that working load is given then multiply with 1.5 and if factored load is given then take as it is.

    • @civilenggmcq7926
      @civilenggmcq7926 7 ปีที่แล้ว

      thank u sir and plz upload more videos on environmental engg

    • @APSEDUVERSE
      @APSEDUVERSE  7 ปีที่แล้ว

      +PARITOSH KASAUDHAN Sure

  • @yashdeepkeer6937
    @yashdeepkeer6937 5 ปีที่แล้ว

    Half knowledge kyu de rahe ho bhai de rahe ho pura batao na

  • @manindersinghbakshi6167
    @manindersinghbakshi6167 4 ปีที่แล้ว +1

    kch explain nhi krta yeh.....padhana aata h nai aur channel chla rhe h youtube pr..

  • @civilbooster
    @civilbooster ปีที่แล้ว

    Thank you