Aircon Circuit Breaker and Wire Size Computation | Philippines | Local Electrician

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ต.ค. 2024

ความคิดเห็น • 380

  • @darwinpagtanac4865
    @darwinpagtanac4865 9 หลายเดือนก่อน +1

    Good Evening Po it's me Darwin Pagtanac from SanIsidro Magalang Pampanga still watching on your TH-cam channel

    • @LocalElectricianPH
      @LocalElectricianPH  9 หลายเดือนก่อน

      Wow! Salamat po Sir. Shoutout po sa inyo

  • @charliegabriel9164
    @charliegabriel9164 ปีที่แล้ว +1

    thanks for sharing. laking tulong sa akin na hindi electrcian.

  • @galawangelectrical
    @galawangelectrical 3 ปีที่แล้ว +1

    watching here lodi kasama harang, thanks for sharing this very informative topic Aircon Circuit Breaker and Wire Size Computation.

  • @MasterBaetiong
    @MasterBaetiong 7 หลายเดือนก่อน +1

    Salamat po sa informative na video. Kukuha po ako ng AC na 2.0hp, nasa specs po ng aircon itself na 10A ang max na running current niya. So sakto po ang 20A na CB, tama po ba? May isa pa kasing nakasulat sa specs na 25A ang recommended na CB pero hindi naman po 'yun available sa atin kaya choice ko po ay between 20A at 30A. Salamat po!

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      Meron naman po 25A na Sir...or 30A pwedi rin...gamit ka 5.5 thhn wire

    • @MasterBaetiong
      @MasterBaetiong 7 หลายเดือนก่อน +1

      @@LocalElectricianPH anong brand po?

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      Royu or omni or koten or schiender

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Lagpas sa 175 to 225 ng FLC yung 30A CB. Overkill na yun. Hindi na magtitrip yun basta basta. Mas ok kung makakita ng 25A CB. ❤

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      @leeedwardtayson9141 thanks sir

  • @rakajawaa5500
    @rakajawaa5500 ปีที่แล้ว +2

    Nice video po. Confirm ko lang po ung ipapakabit ko TCL 1HP TAC-09CWI/UJE, okay lang po ba 20A 3.5mm #12?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Yes po

    • @j40377
      @j40377 3 หลายเดือนก่อน +1

      @@LocalElectricianPHhi po. eto po ung sukat na alam ko, 12 awg for 20amps. peo pinabibili sakin 10awg 20amps mcb, same po kami ng ac 1hp Tcl. tama po ba cla? tpos sa ilaw nag #12awg kc daw nagbago na PEC? tama po ba? sana po makapgreply kyo. slmt po.

    • @LocalElectricianPH
      @LocalElectricianPH  3 หลายเดือนก่อน

      Ok lang naman mg size up ng wite lalot mahahaba ang wiring..yun nga lng mapapagastos kayo..pero ok yan mag size up kaysa mag downsize

  • @markwhite3938
    @markwhite3938 8 หลายเดือนก่อน +1

    Sir ung video nato applicable to lahat na 1.5hp wind or split type inverter?

  • @louiecao
    @louiecao 2 ปีที่แล้ว +2

    Sir, salamat sa video mo. May tanong lang ako Sir, panu naman ang magiging pag size ng breaker at wire gauge kapag nagdagdag ka ng aorcon sa bahay. Sana mapansin nyo po ito.

  • @bongcomcom9837
    @bongcomcom9837 3 หลายเดือนก่อน +1

    Hi ask lng po pede po ba sa 1.5 hp split type 20amp size 10 wire? Instead of 12

    • @LocalElectricianPH
      @LocalElectricianPH  3 หลายเดือนก่อน

      Yes pwedi naman po

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Yes po. Goods naman po yan. Kaya lang mas may kamahalan nga lang kaya hindi practical 😂

  • @paanovlog3296
    @paanovlog3296 2 ปีที่แล้ว +2

    ambangers nio ako sir..ask kulang po sana sa 20A pwde poba dalawang window type na aircon at ano size ng wire #12 awg poba?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      1 is to 1 lng po tayo sa ac sir.

    • @paanovlog3296
      @paanovlog3296 2 ปีที่แล้ว +1

      @@LocalElectricianPH pano po kong 30A tapos no.12 na wire ganun din poba 1 is to 1?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      No.10 po gamitin nyo f 30 amps sir. 12 sa 20A. Mg panel board nlng po kau sir.

    • @paanovlog3296
      @paanovlog3296 2 ปีที่แล้ว +1

      @@LocalElectricianPH slamat sir sa sagot😇

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Wwlcome po sir

  • @samanthajerag.netario6869
    @samanthajerag.netario6869 3 ปีที่แล้ว +2

    sir kapag po ba motor ang kailangan wire talaga gamitin ay THWN? di po pede na THHN wire ang gamitin para 90c sya?

  • @danieltaylor8830
    @danieltaylor8830 ปีที่แล้ว +1

    Idol, halimbawa may existing #14 wire ffrom fuse box na may 15A CB sa dulo para sa 0.6 ACU, pwede kaya i-splice ku yung 14# wire at magdagdag ng isa pang 15A CB for another 0.5 ACU

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      D i po pwedi splice Sir..need mo recta sa breaker papuntang ac...1 is to 1

  • @beverlyhomboy4917
    @beverlyhomboy4917 ปีที่แล้ว +1

    Hi, kapag 2hp split type aircon, anong wire and breaker ang dapat gamitin? Thank you po.

  • @Javier-lj8ss
    @Javier-lj8ss 5 หลายเดือนก่อน +1

    Hi po curious lang po ako ngayun na calculate nyo na po na dapat gamiten is 3.5mm na cable but prang meron kulang po kasi yung 3.5mm pag mag draw ng let say up to 20A at what distance po bago mag change for example po yung 2.5mm na cable can only cary 20A in 15meters tapos size up na dahil sa Vd.

    • @LocalElectricianPH
      @LocalElectricianPH  5 หลายเดือนก่อน

      Iba pa yan Sir computation ng voltage drop...

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Meron din po sa PEC nyang voltage drop per meter ng bawat wire gauge.

  • @fannyuser3796
    @fannyuser3796 ปีที่แล้ว +1

    Sir ask lang po saan natin mahana ang (PEC)? Salamat po.. sana masagut nyu po.. godbless

  • @marwinsmesa
    @marwinsmesa ปีที่แล้ว +1

    Hello, pag dalawang 1hp aircon. 2x20A circuit breaker tapos 3.5mm. pwede bang i splice yung wire coming out of 2 circuit breaker papuntang panel board?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Separate cb and wire po dapat Sir. Papuntang panel

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Special Outlet po ang ACU, mula panel board hanggang sa conduits, recommended po na solo lang nya ang line.
      From 20A cb, hanggang sa batak at latag ng conduits, hanggang sa outlet ng aircon, solo nya lang po. ❤

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      @leeedwardtayson9141 thanks sir

  • @roelalintv1421
    @roelalintv1421 2 ปีที่แล้ว +1

    Good evening sir, diyan po sa video mo ang naging computation mo sa 1.5HP is 20A lang, halimbawa kung gagamit Ako Ng 30A Hindi ba pwede?

  • @victoralmoniajr9971
    @victoralmoniajr9971 2 ปีที่แล้ว +2

    Ok lang Po ba na 30amp Yung breaker sa 1hp inverter aircon

  • @daudsappal68
    @daudsappal68 7 หลายเดือนก่อน +1

    Sir pwede po ba akong gumamit ng number 12 pdx wire sa 0.5hp?

  • @mlislife6225
    @mlislife6225 2 ปีที่แล้ว +1

    Sir tanong lng. 20a cb ko. At. 08 acu ko. Pde Pa po Ba ko mag lagay ng outlet dun para sa computer?

  • @jhannymarange2702
    @jhannymarange2702 9 หลายเดือนก่อน +1

    Sir kapag sa 2hp po na aircone window type sya ayus lng ba yung 3,5mm² yung wire and 30A ang breaker?

    • @LocalElectricianPH
      @LocalElectricianPH  9 หลายเดือนก่อน

      5.5mm² sir at 30A cb..pero f 3.5mm² na thhn pwedi..tapos 25A cb....kaso bihira ang 25A cb sa atin...21A to 27A kasi ang cb nya dapat base on computation...pero f hindi sya mg trip sa 20A cb..ayos lng

    • @jobellelera
      @jobellelera 7 หลายเดือนก่อน +1

      Sir ano po dpat ang wire and CB ng 1.5 hp split type?

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      @jobellelera 20A cb 3.5mm thhn type wirr

  • @roelalintv1421
    @roelalintv1421 2 ปีที่แล้ว +2

    Saan n'yo po nakuha iyong listahan Ng ampere rating sir, mayroon ba iyan sa national book store?

  • @cjstories5429
    @cjstories5429 ปีที่แล้ว +1

    sir para sa AC na full DC Inverter Po, 20 or 30amp po ba?alin Po sa dalawa need ko bilhin.

  • @regietangente5073
    @regietangente5073 3 ปีที่แล้ว +1

    Thanks po sa video sir. Tanong ko lng po, anong tamang breaker at number ng wire para sa 1hp na aircon interver type? Salamat po

  • @ronnahmaemelon3522
    @ronnahmaemelon3522 ปีที่แล้ว +1

    Sir tanong lang po ganyan lang din po ang formula sa pag compute ng chest freezer o inverter na Aircon

  • @ellag.3781
    @ellag.3781 4 หลายเดือนก่อน +1

    paano po pag 2 unit ng 3 tons stand floor at isang 2.5 na split? ilang ampheres po yun at anong wire. salamat po. yung main breaker kasi namin nainit. Pinalitan na yung wire ng main ng 8.0 at yung breaker ng 60amp ganun pa rin. Pag pinagsasabay sabay yung tatlo umiinit yung main breaker.

    • @LocalElectricianPH
      @LocalElectricianPH  4 หลายเดือนก่อน

      Mag base po kayo sa full load current ng bawat aircon..makikita yan sa specs sticker ..dn bawat aircon FLC x 2.25 = Size ng individual CB...dn sa total amp ng CB e add mo lahat ng FLC plus 25% ng highest rated motor

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      35-40AT CB, 5.5mm² or AWG 10 THHN na po per Aircon Unit need nyo. Mag iinit po main breaker nyo kase kailangan nyo na pong magpacompute ng full load schedule dahil sa tingin ko po ay nag upgrade kayo ng mga heavy load appliances. Dapat nasa range na po kayo ng 60A CB+14mm² wire or above pa po. Hindi na po kaya ng 8.0mm² yun at hindi po specified ang 8.0mm² for 60Amp CB

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Hindi lang po CB ang nag iinit. Ang nauuna pong maginit ay yung linya na nakakabit sa CB na yun. It may cause fire pa if papabayaan.

  • @fredmarksantillan6109
    @fredmarksantillan6109 2 ปีที่แล้ว +1

    hello goodday boss
    sa 1hp aircon
    20A CB #12AWG/3.5mm wire gagamitin? tama po ba? thank you

  • @Ground_Effex
    @Ground_Effex 7 หลายเดือนก่อน

    Sir, applicable pa din po ba yung 20A circuit breaker para sa 1.5 HP na window type ac at 25A circuit breaker para sa 2 HP window type ac? Para updated pa din po ako sa latest PEC.

  • @mjcqjoson9375
    @mjcqjoson9375 6 หลายเดือนก่อน +1

    if 2 ac (1 hp at 0.5), puede po ba sa isang line lang? then 2 branches?

    • @LocalElectricianPH
      @LocalElectricianPH  6 หลายเดือนก่อน

      In that case Sir..need nyo panel board to have 2 acs individual branch sa panel board po. Kasi f mg isang line kayo need nyo pa ng another cb to support sa wiring papunta sa 2 ac..yes gagana yan sir pero i cant recommend that way po.

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Negative po yan. Wag na wag po kayo magsasabay ng 2 AC or any continuous running motor sa iisang linya. Iba po ang startup operating current computation nyan lalo na kung sabay binuksan. Hindi po sya as simple as 1.0hp + 0.5hp = 1.5hp. both ACs are recommended to be treated as Special Outlet Aplliance. Means, both have their own CB and Wirings with matched specifications.

  • @MerriteBaloy
    @MerriteBaloy 4 หลายเดือนก่อน +1

    Boss kaya naba nang 3.5 wire ung 1.5 hp. Na split typ aircon

    • @LocalElectricianPH
      @LocalElectricianPH  4 หลายเดือนก่อน

      Yes gamit ka 3.5mm² thhn wite with 20A cb

    • @MerriteBaloy
      @MerriteBaloy 4 หลายเดือนก่อน

      Galing na po sa panel board ung 20 amps. Tapos ung papunta sa kwarto 3.5 po ok po ba un sir.

    • @LocalElectricianPH
      @LocalElectricianPH  4 หลายเดือนก่อน

      @user-dz4sq2de9x yes ok po basta solo nya sa branch

  • @nemrodmondez6492
    @nemrodmondez6492 ปีที่แล้ว +1

    pwde ba tong #12 2.0mm/2 na wire pra 20amp breaker, 0.6hp na aircon? Parang ibang wire kasi yata nabili ko #12 nmn sya kaso 2.0mm lng hindi 3.5mm

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Yes po #12 awg yan solid wire..katumbas ng 2.omm² 20A parin po yamm..ok yan

    • @nemrodmondez6492
      @nemrodmondez6492 ปีที่แล้ว

      @@LocalElectricianPH Maraming salamat po. Pro alin po ba mas ok kumpara sa 3.5mm?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Same capacity naman yan Sir..hang 3.5mm² stranded kasi yan...unless gusto mo ng higher temp. 3.5mm² na thhn mas ok..pero sa load mo na .6hp kayang kaya yan

    • @nemrodmondez6492
      @nemrodmondez6492 ปีที่แล้ว +1

      @@LocalElectricianPH Ah ok. slamat po

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Welcome po

  • @zaldymnyql7074
    @zaldymnyql7074 3 ปีที่แล้ว +2

    boss ,ask lang po, paano po pag compute ng aircon tonnage? tnx

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว +1

      1 ton = 3.5 kw sir

    • @MaeGarcia-ey2dn
      @MaeGarcia-ey2dn ชั่วโมงที่ผ่านมา

      Sir ano breaker at wire dpt gamitin sa 0.75 salamat po

  • @jackofalltrades7786
    @jackofalltrades7786 ปีที่แล้ว +1

    Lods ano ba magandang gamitin sa aircon cercuit breaker o yung magnetic contactor switch? Problema kasi sa magnetic palagi naga trip off tapos buksan naman para e reset ang thermal switch

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Circuit breaker po...basta akma ang size para sa hp rating ng AC

  • @ramaquino9776
    @ramaquino9776 ปีที่แล้ว +1

    Pasok ba yang 20A CB kung starting current ang oagbabasihan...

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Yes po dependi sa HP rating ng AC Sir

    • @ramaquino9776
      @ramaquino9776 ปีที่แล้ว +1

      @@LocalElectricianPH 1.5 hp kasi ang issue d2..,pasok ba sa 1.5hp starting current...

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Sir ito po ay base sa PEC standard. Iba po ang computation ng compressor sa induction motors po. Pasok po sa 175% to 225% ang 20A sa 1.5hp AC Sir.

    • @ramaquino9776
      @ramaquino9776 ปีที่แล้ว +1

      @@LocalElectricianPH kasi starting current ang basihan ko ng breaker NG motor & wire size...

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Ah ok po Sir ..d po ako makikipagtalo sa inyo sa bagay na yan..hehe..basta po ako sa Philippine Electrical Code parin ako mag base po ng computation. . Salamat Sir

  • @calixbella
    @calixbella 7 หลายเดือนก่อน +1

    hello po. ask ko. lng ang aircon ko po 1.5HP at ang outlet ko ay 20amp na may #10 size wire naka connect sa 30amp circuit breaker ok lng po ba?

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน +1

      Dapat 20A lng ang breaker sa 1.5hp sir..masyado mataas ang 30A

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      ​@@LocalElectricianPHbaka po ibig nya sabihin, 30A ang main CB nila.
      Depende po sa overall load ng bahay kung other appliances ay 2 pcs efan, 5 lightings. 1 acu 1.5hp. ok na po yung 30A main CB. Pero kung may ref, at ibang large appliances. Negative na po yang 30A CB

  • @aljancabatingan6379
    @aljancabatingan6379 3 ปีที่แล้ว +1

    Sir ask lang po, anong size ng circuit breaker for 6hp cassete type aircon? thank you po

  • @soroanjonnel9484
    @soroanjonnel9484 7 หลายเดือนก่อน

    Good day master tanong kulang po kung kaya Ng 30amp Ang dalawang 1.5hp ,ty po

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      1 cb per ac lng po Sir... 20A sa 1.5hp per ac

  • @noahidos873
    @noahidos873 2 ปีที่แล้ว +1

    2hp po sir. pwede ba 12 na wire?

  • @MajesticRecaps23
    @MajesticRecaps23 3 ปีที่แล้ว +1

    Good day po sir. Itatanong ko lang po yung about sa computation ng CB ampere ng aircon, ang gamit po kasi ng iba is 250% sa Table 4.30.4.2 po nila kinuha, sa inyo naman po maging yung sa iba is 225% sa table 4.40.4.2 naman, ano po ba dahilan akit magkaiba. Anyway maliit lng naman deperensya 0.025% lang. thanks…

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว +1

      Iba po kasi computation ng motor at ac compressor sir

  • @cirilabagon3813
    @cirilabagon3813 7 หลายเดือนก่อน +1

    Sir good afternoon po 1.5hp split type aircon inverter pwede po ba 32A na MCB?

  • @astralavizta200
    @astralavizta200 ปีที่แล้ว +2

    anong tamang breaker at number ng wire para sa 2hp na aircon interver type?
    Tama po ba na dalawang circuit breaker, isang circuit breaker katabi sa acu at naka connect sa isang branch ng circuit breaker doon sa loob ng panel?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      30A 5.5mm thhn Wire

    • @astralavizta200
      @astralavizta200 ปีที่แล้ว +1

      @@LocalElectricianPH ok din po ba kung magdagdag ako ng 20A katabi ng 2hp acu then naka connect sa 30A cb sa panel?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Idaan nyo po sa panel board Sir..anh 30A for ac nyo ay solo dapat

    • @astralavizta200
      @astralavizta200 ปีที่แล้ว +1

      @@LocalElectricianPH Good eve ulit sir, tama lang po ba na ang main cb ay 40A?
      2HP ACU (30A)
      0.8HP ACU (20A)
      Lighting, CO (15A)
      Main CB (40A)
      Tama po ang nasa panel?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Gawin nyo po 60A Main #6 copper or #4 aluminum na service entrance wire

  • @spidey3747
    @spidey3747 20 วันที่ผ่านมา +1

    Bro my tanong po ko.good at safe po ba gamitin yun circuit breaker na my outlet na sa ilalim.thanks po

    • @LocalElectricianPH
      @LocalElectricianPH  19 วันที่ผ่านมา

      Yes sir..sa AC po ba? Basta tama ang size ok yan

    • @spidey3747
      @spidey3747 19 วันที่ผ่านมา

      @@LocalElectricianPH thanks po

    • @LocalElectricianPH
      @LocalElectricianPH  19 วันที่ผ่านมา

      @spidey3747 welcome p o sir

    • @spidey3747
      @spidey3747 19 วันที่ผ่านมา

      Salamat bro

    • @LocalElectricianPH
      @LocalElectricianPH  18 วันที่ผ่านมา

      @spidey3747 salamat dn po sir

  • @itsprivate5623
    @itsprivate5623 ปีที่แล้ว +1

    Lods ok lang ba na 40A ang circuit breaker ng 1.5hp na aircon? Yon kasi nakita kong nakalagay sa panep board na circuit brealer ng aircon 40A

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      20A lang po yan Sir. Oversize yan 40

    • @itsprivate5623
      @itsprivate5623 ปีที่แล้ว

      @@LocalElectricianPH ito kasi nakalagay sa box panel board ng apartment boss pwede ba palitan to boss kaya lang ung wire nya to putlet hindi mapapalitan fix kasi ok lang ba di napalitan wire kung sakali?

    • @itsprivate5623
      @itsprivate5623 ปีที่แล้ว

      @@LocalElectricianPH at masisira ba AC ko kapag pversize ang circuit breaker boss. 1.5hp inverter kolin gamit ko

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      F 3.5mm or higher gauge ang wire nyan no need palitan..yes pwedi palitan ang cb....d naman masisira dahil sa mataas ang cb ng ac...wala lamg syang protection in case of overload or short ckt...sonog na ac mo..d pa mg trip cb mo

    • @itsprivate5623
      @itsprivate5623 ปีที่แล้ว +1

      @@LocalElectricianPH aww buti natanong kita lods kakabili ko lang kahapon ng kolin full dc inverter kasi na 1.5hp kaya nagwoworry ako kasi napanood ko mga vlogs mo. Papapalitan ko ng 20A ang CB sa main panel board as soon as posible lods. 20 A lang mismo lods noh? Salamat lods

  • @richarddaviddumalag9901
    @richarddaviddumalag9901 หลายเดือนก่อน

    Sir sa table 3.10.1.16 hanggang 25 amps ung 2.5mm2 nd ba sya pwedeng gamitin since 12.5amps lang ung calculated load ng 1.5hp?

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      Pwedi naman po sir basta pasok sa ampacity at tugma sa cb size basta tamang type dn po ng wire

    • @richarddaviddumalag9901
      @richarddaviddumalag9901 หลายเดือนก่อน

      @@LocalElectricianPH Noted sir, 2 factor pla maliban sa konsumo ng amperahe ng load need dn pla na ung CB is match sa wire.

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      Yes sir..dapat match size

  • @sirnickotv7165
    @sirnickotv7165 2 ปีที่แล้ว +1

    Sr gdpm, counter check lng dn po, 200amp main panel, isa slot 30amp meron po, magllgay po bukod C.B. 30amp near A.C 2hp, tma po b sir? Size of wire 14awg?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      10awg po ang partner ng 30A cb Sir.

    • @sirnickotv7165
      @sirnickotv7165 2 ปีที่แล้ว +1

      Thank you, sir. Yung 200amp(main) --》30amp(1slot sa panel)--》30amp(near aircon) ok namn po ito?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Dependi yan sa overall load nyo Sir..basta f 30A breaker 10awg. Pag 20 A ay 12awg

    • @sirnickotv7165
      @sirnickotv7165 2 ปีที่แล้ว +1

      Thank you sir. Hnd ko makita fb page nyo sir. Pd po pasend link dto. Para follow ako

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      facebook.com/localelectricianandmore

  • @rizzapalconit4965
    @rizzapalconit4965 10 หลายเดือนก่อน +1

    Sir sa amin kac is 0.6 hp tapus ginagamit na min na wire is 1.6 mm ung breker njya po is 30 amp uk lng po ba un

    • @LocalElectricianPH
      @LocalElectricianPH  10 หลายเดือนก่อน +1

      20A cb 3.5mm² dapat wire Sir

    • @rizzapalconit4965
      @rizzapalconit4965 10 หลายเดือนก่อน

      @@LocalElectricianPH pero sir puede parin un ba sir

    • @LocalElectricianPH
      @LocalElectricianPH  10 หลายเดือนก่อน

      @rizzapalconit4965 unsafe po..masusunog nlng wire mo pag meron problema d yan mg t trip cb

    • @rizzapalconit4965
      @rizzapalconit4965 10 หลายเดือนก่อน +1

      @@LocalElectricianPH ako uk sir salamat po sir

    • @rizzapalconit4965
      @rizzapalconit4965 10 หลายเดือนก่อน

      @@LocalElectricianPH maraming salamat po sir isa na lng po na tanong sir sa main panel talaga sya connect po bah?

  • @andriebon7346
    @andriebon7346 2 ปีที่แล้ว +1

    Sir 1hp aircon ko,anong amperes ng cb ang dapat bilhin ko pra sa ac?

  • @missgracie1865
    @missgracie1865 ปีที่แล้ว +1

    Hi po sir ask ko lang po yung tamang breaker for .8hp na window ac at yung size po ng wire.thank u po

  • @elizaldedaan4237
    @elizaldedaan4237 3 ปีที่แล้ว +1

    Paano kng instead 1.5hp c.breker 20 A gagamitin gawin kong 30 A puede po ba. Pls advice..

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      Gagana naman po..kaso oversize. Baka hindi yan mag trip sisirain muna compresor nyo bago mg trip

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน

      Walang silbi po yung CB nun pag ganun. Need muna mag short circuit bago mag trip. Sunog na ung linya. Kaya dapat matched po ang wire specs and CB specs

  • @fluffyabdurahman8958
    @fluffyabdurahman8958 2 ปีที่แล้ว +1

    Kaya po ung 10amp para sa 1hp na ac?

  • @tzadebalois7345
    @tzadebalois7345 2 ปีที่แล้ว +1

    Pwd ba na 20amp ang breaker tapos ang wire is 5.5mm? Pra sa 1 hp aircon?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Pwedi naman po f may stock wire kau jan..pero f wala 3.5mm pwedi napo...mapapamahal lng po kayo sa 5.5

    • @tzadebalois7345
      @tzadebalois7345 2 ปีที่แล้ว +1

      @@LocalElectricianPH YEs meron ako stock dito..okay n nakabit ko nasa new nit ko,,ty

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      👍👍👍

  • @aceavila4222
    @aceavila4222 ปีที่แล้ว +1

    sir may website po kaya para maka pag download nung PEC?

  • @LucasMateo-hq3kg
    @LucasMateo-hq3kg ปีที่แล้ว

    sir,kung dalawang 1.5hp na aircon need ba magkahiwalay na circuit breaker at anong size po ng wire

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Yes po hiwalay..20A each na cb at 3.5mm² thhn wire.

  • @prodesign8928
    @prodesign8928 2 ปีที่แล้ว +1

    Ok lang Po ba n mas mataas Ang amperahe ng acu kesa sa c.b?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Hindi po...mg t trip po breaker nyo

    • @prodesign8928
      @prodesign8928 2 ปีที่แล้ว +1

      Pero 22.5a Po NASA computation nyo idol. Ibig Sabihin mas mataas kesa sa 20a. Salamat

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Sir 175%-225% po ng FLC ang breaker..hindi po mas mababa Sir. Kasi 10A lang po FLC natin sa 1.5hp ac

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Yung 20A breaker po ay pasok sya sa 175 to 225% ..meaning pwedi sa kanya ang breaker na 17.5A to 22.5A dn wala namang breaker na ganyan sa mercado unless mag pa costumize po kayo..kaya 20A ang nka lagay po jan

    • @prodesign8928
      @prodesign8928 2 ปีที่แล้ว +1

      Ah ok sir. Pwede xa sa 17.5-22.5A na c.b. salamat idol

  • @SolarBoyPH
    @SolarBoyPH 7 หลายเดือนก่อน +1

    Boss balak ko mag split type na aircon 1hp, pwede po ba ung 30 amperes na breaker?

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      20A lng po

    • @SolarBoyPH
      @SolarBoyPH 7 หลายเดือนก่อน +1

      @@LocalElectricianPH sir ok lng ba ung 30 amp na breaker na lng gawin kong main, tapos sa aircon ko 20ampere? Ok lmg po ba yn? Washing tv ref ilaw at saksakan lng gamit ko sa bahay. Salamat sir.

    • @LocalElectricianPH
      @LocalElectricianPH  7 หลายเดือนก่อน

      40A po e main nyo..#8 poba ang service drop cable nyo? Tapos sa branches mo ac 20A outlets20A ilaw 15A ref20A

  • @JenTaljaJenjen-xh9lb
    @JenTaljaJenjen-xh9lb ปีที่แล้ว

    Sir pwede po bang yung main breaker 40A tapos yung pang AC ayy 30A?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      F main ay 40A dapat ang branch ay d lalagpas sa 50% neto whc is 20A....ilan ba hp ng ac nyo sir

  • @jakeconde2871
    @jakeconde2871 2 ปีที่แล้ว +1

    Hi Sir, kung dalawa unit ng aircon both split type 1.5hp at 1.0hp, ano po main wires ang gagamitin at breaker? thank you in advance :)

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว +1

      E separate nyo po ng breaker yan Sir. Tig 20A breaker tpus 3.5mm na wire..pagdating sa main ay dependi po yam sa kaboang load nyo sa bahay

    • @jakeconde2871
      @jakeconde2871 2 ปีที่แล้ว +1

      @@LocalElectricianPH salamat po sir, ff pwede po ba kung 2 wires lang gagamitin ko pa punta sa outdoor unit ng two aircon, balak ko sana i-jump na lang sa yung dalawang breaker sa two wires na galing sa main breaker. medyo mahaba po kase yung pag gagalingan from main cb two outdoor unit. or need ko pa rin sir na 4 wires na 3.5mm pa punta sa main panel?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Welcome po

  • @gumabonsharmainej.7787
    @gumabonsharmainej.7787 2 ปีที่แล้ว +1

    Sir tanong ko lng po yung ac ko po ay sharp 0.5 hp bakit sabi daw po ng kakabit ng aircon 30A daw po bibilhin ko na breaker. Dba po dpat 15A lng?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Yes kaya naman 15A..pero mas better po 20A

    • @kevinnozup8813
      @kevinnozup8813 2 ปีที่แล้ว +1

      Sir ok lang ba 20amps 5.5 wire 0.75 hp pa baba ??

    • @kevinnozup8813
      @kevinnozup8813 2 ปีที่แล้ว

      Nag over sized po kasi ung amp ang wires

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Sayang pera nyo Sir
      ..20A 3.5mm wire lng minimum natin small appliances

    • @kevinnozup8813
      @kevinnozup8813 2 ปีที่แล้ว +1

      Unsafe po ba pag 30amp 5.5 wire ang gagamitin?

  • @rosemariemosqueda9668
    @rosemariemosqueda9668 3 ปีที่แล้ว +1

    ask lag po sir. anong tamang breaker po para sa 0.5hp?

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      15 amps mam.

    • @Prince-tt3xi
      @Prince-tt3xi ปีที่แล้ว

      @@LocalElectricianPH sir, good day! Bakit sa PEC, ang FLC ng 0.5hp is 4.9A * 225% = 11A (sabi nyo sir based sa PEC, not exceeding 225% dapat) so bakit po 15A CB reco nyo? Di po ba pwede yung 10A? Though, hnd na sya pasok sa standard ampere ratings...
      Thank you po sa pagturo, sir!

  • @benchmacawile9285
    @benchmacawile9285 3 ปีที่แล้ว +1

    ano po magyayari kng sa panel 30A ttapos s nema 3r nya 60A na aircon.

  • @maesalas6990
    @maesalas6990 11 หลายเดือนก่อน

    Sir how about sa fujidenzo 0.60hp inverter window type anong wire po dpat..

  • @RandySelleza
    @RandySelleza 7 วันที่ผ่านมา +1

    Good day. . Magtanong po sana ko tungkol sa aircon. Yung luma po nmin aircon almost 3 yrs napo gamit window type, ngayon po bigla nlang po sya namamatay pag lumipat na cool, pero pag sa fan lang ok nman hindi namamatay. Ngayon po nagpalit kami ng bago ganon pa din po pag fan ok nman po kahit ilan oras naka fan pero pag nilipat na sa cool namamatay din po. . Possible po ba na sa breaker ang sira. . At kung papalitan po ba ng breaker ilan ampere po ang ipapalit nmin . . 15 amp po yung dating nakalagay. 1hp nman po yung aircon. Salamat po sir

    • @LocalElectricianPH
      @LocalElectricianPH  7 วันที่ผ่านมา +1

      20A cb at 3.5mm² thhn wire gamitin nyo po baka di nya kaya ang starting current of ng loose sa wiring or cb nyo

    • @RandySelleza
      @RandySelleza 7 วันที่ผ่านมา +1

      @@LocalElectricianPH salamat po sir

    • @LocalElectricianPH
      @LocalElectricianPH  6 วันที่ผ่านมา

      @RandySelleza welcome po magandang gabi

    • @RandySelleza
      @RandySelleza 5 วันที่ผ่านมา

      @@LocalElectricianPH gudeve sir, paistorbo lang ulit. Yung wire po ba ng breaker papuntang socket?

    • @RandySelleza
      @RandySelleza 5 วันที่ผ่านมา +1

      @@LocalElectricianPH at paano po ba sa matukoy kung nag loose na po

  • @richterarcangel66
    @richterarcangel66 10 หลายเดือนก่อน +1

    Pag 0.75hp po sir paano ang basa nun sa PEC?

    • @LocalElectricianPH
      @LocalElectricianPH  10 หลายเดือนก่อน

      Need nyo po 20A cb at 3.5mm² thhn na wire sir

  • @djamesdjonbarol610
    @djamesdjonbarol610 3 ปีที่แล้ว +1

    Pwde Po bang Isang circuit breaker sa tatlong Aircon sir?

  • @kristaljoyrabino3623
    @kristaljoyrabino3623 2 ปีที่แล้ว +1

    Ano pong tamang amp at # ng wire sa 1hp na aircon window type po?

  • @pat4645
    @pat4645 2 ปีที่แล้ว +1

    bakit po 20A yung circuit breaker? mas maliit pa dun sa 22.5A na nacompute?

  • @cvelasquez4205
    @cvelasquez4205 2 ปีที่แล้ว +1

    Paano sir nakuha yung mga multiplier kada hp.
    Sa 1hp paano naging 8? Ano po formula na gamit sir

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว +1

      Standard po ng PEC Sir.

    • @cvelasquez4205
      @cvelasquez4205 2 ปีที่แล้ว +1

      @@LocalElectricianPH ah ok sir salamat po ng marami. Madami po ako natututunan sa mga video niyo. More power

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Welcome po. Salamat sa panonood.

  • @samanthajerag.netario6869
    @samanthajerag.netario6869 3 ปีที่แล้ว +2

    sir kung 0.75HP ang ACU na ikakabit ko bali sa nominal voltage sa 230V ay 6.9 x 225% bali 15.525A, ibig sabihin sir 15A lang po ang gagamitin kong circuit breaker para sa 0.75HP na ACU? kung sa wire naman po na gagamitin 6.9 x 125% bali 8.625 ang wire po na gagamitin ay #14 or 2.0?

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      Yes po mam.

    • @samanthajerag.netario6869
      @samanthajerag.netario6869 3 ปีที่แล้ว +1

      @@LocalElectricianPH tnx po sir

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      Welcome po

    • @eugeniogozon7440
      @eugeniogozon7440 ปีที่แล้ว +1

      @@LocalElectricianPH Sir, sabi mo po sa isang video, yung sa 1hp na video, ang minimum para sa 1hp pababa ay 20A na CB at 3.5mm2 na wire. Alin po ba ang tama? Salamat po.

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Yes Sir. Standard po talaga yan kc considered small Appliances ay 20A Cb at 3.5mm wire ang gagamitin..minimum requirements....pero ang tanong kc ni Maam ay kong kakayanin po ng 15A cb amg .75hp nha...ang sagot ay kayang kaya po..ma consider natin na hindi standard. Pero totally safe parin sya...since base sa actual computation natin ay kaya nya e handle ang load.

  • @itsprivate5623
    @itsprivate5623 ปีที่แล้ว

    At pwede ba lods ung breaker i connect sa saksakan ng aircon ko ngaun kapag mag install ako circuit breaker?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Dko po ma gets ibig nyong sabihin Sir...follow nyo lng po ito...power supply input to ckt breaker. Dn cb out to outlet..dn don kau sa outlet mg sak2 ng ac...or meron dn nabibili na Ac cb.with built in outlet napo

    • @itsprivate5623
      @itsprivate5623 ปีที่แล้ว

      @@LocalElectricianPH may outlet kasi kami lods ng ac ngaun kapag naglagay ba ng circuit breaker dun kukunin power supply sa outlet ng Ac o sa mismong main breaker ng bahay dapat?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      F connected na sa ckt breaker na solo ang outlet intended for ac..ok na yan sir...1 cb for 1 ac

    • @itsprivate5623
      @itsprivate5623 ปีที่แล้ว

      @@LocalElectricianPH wala po siya CB lods. Outlet for Ac lang eh. Dahil napa ood kp vlog mo parang gusto ko lagyan ng CB. Sa outlet lang ba ako luluha ng supply at sa outlet ng ac ko lang ba itatap ang CB lods?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Papaano pong walang cb ang outlet nyo sir?? Saan galing linya nyo? Recta sa poste ng kuryente? Yes pwedi nyo yan lagyan jan..cut nyo yang linya ng outlet. Dn lagyan nyo ng cb

  • @johnpiolobantog291
    @johnpiolobantog291 3 ปีที่แล้ว +1

    at sir sa 2HP na AIRCON ilan AMP po salamat OJT LANG SANA masagot aga sir salaamt po

  • @johnnychin9598
    @johnnychin9598 ปีที่แล้ว

    sir paano po kung inverter type po yun aircon, sabi kasi mas mababa daw yun ampere paano computation ng 2hp inverter aircon

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Yes mas mababa ng kaunti pero dependiparin sa pag gamit yan...wag po maging kampanti kasi inverter f gusto nyo mka tipid. Tamang setting at timing parin po ang kailangan

  • @gilbertgalina6749
    @gilbertgalina6749 3 ปีที่แล้ว +1

    Sir ung .6hrp ang wire at breaker n pwdeng gamitin p help nmn

  • @ronniearciga8643
    @ronniearciga8643 ปีที่แล้ว +1

    Ilan amperes ng circuit breaker para sa 2.5 Hp na inverter na split air conditioner? Anong size po ng wire din? Ty

  • @itsprivate5623
    @itsprivate5623 ปีที่แล้ว +1

    Magkano usually palagay ng ganito ngaun lods?

  • @robertnava3956
    @robertnava3956 ปีที่แล้ว +1

    itatap ko lang yong dalawang wire sa existing na 20 amperes idol magdadagdag sana ng isang aircon kaso wala ng spare eh sana mapansin mo idol

  • @marcosjuancordova5906
    @marcosjuancordova5906 8 หลายเดือนก่อน

    Isang 1hp at isang 1.5 power sa 30amp cb kaya po ba?

  • @jrbansao5601
    @jrbansao5601 3 ปีที่แล้ว +1

    sir anu wire size at breaker sa 2hp aircon

  • @djamesdjonbarol610
    @djamesdjonbarol610 3 ปีที่แล้ว +1

    Paano po Kung madami na Aircon ilang circuit breaker Ang gagamit?

  • @jazzlayne5993
    @jazzlayne5993 3 ปีที่แล้ว +1

    sir hinde ko po padin maintindihan sir..
    yun sa 175 percent - 225 percent. paano po yun sir sana masagot niyo po salamat.
    baguhan palang po .

  • @jessiedelacueva5469
    @jessiedelacueva5469 2 ปีที่แล้ว +1

    sana po mapansin, size po kasi yung wie ng supply galing poste papuntang bahay, magkakbit sana kamo ng isang split type ac 1.5 which is pang apat na siyang A/C dito sa bahay, nagwoworry po kami kung kakayanin paba nung supply pag nagsabay sabay lahat, any suggestions po will really appreciate po

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Ano po size ng main feeder nyo mam? #6 aluminum po ba?

    • @jessiedelacueva5469
      @jessiedelacueva5469 2 ปีที่แล้ว +1

      di ko rin po alam eh, wala po ko idea ang alam lang namin is yung wire na nagcoconnect sa supply galing sa poste papuntang bahay is 8 or 10 😥

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Ahh ok yung minimum req.is 8 f copper. 6 f aluminum...hindi napo yqn kakayanin mam...4 AC na 1.5hp. Nasa 40Amps napo max nyan..dagdag nyo pa ibang gamit. Apply po kau ng upgrade..atleast 100 amps katumbas ng #1 copper wire feeder from post

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Ilan po ba Amps ng Main Circuit Breaker nyo Mam

    • @jessiedelacueva5469
      @jessiedelacueva5469 2 ปีที่แล้ว +1

      sa pagakakaalala ko dun sa huling nagkabit 30 daw po

  • @tonyooynot9582
    @tonyooynot9582 2 ปีที่แล้ว +2

    kung .5HP ang aircon ko ano size ng wire at ano ampers nh circuit breaker ko

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      3.5mm wire at 20A breaker.. or pwedi rin 15A Sir

    • @tonyooynot9582
      @tonyooynot9582 2 ปีที่แล้ว +1

      salamat bro succes ang DIY ko hirap pala maglayout sa loob ng kesame ang init

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Nice one Sir😊

  • @RRR-sl1ig
    @RRR-sl1ig 2 ปีที่แล้ว +1

    hi sir baka may link kayo ng PEC na gamit nyo thx

  • @remjoycarino709
    @remjoycarino709 ปีที่แล้ว

    Yung amin po 1hp nabili namin 15amp pwede na kaya po ?

  • @maycelnido2843
    @maycelnido2843 2 ปีที่แล้ว +1

    ilan amp po kapag 2.5hp window type

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      30A

    • @maycelnido2843
      @maycelnido2843 2 ปีที่แล้ว +1

      @@LocalElectricianPH ano pong number ng wire ang gagamitin??

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      5.5mm

    • @maycelnido2843
      @maycelnido2843 2 ปีที่แล้ว +1

      @@LocalElectricianPH parang may nabasa ko sa comment na reply nyo #10 alin po ang mas tama?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      #10 AWG wire is equivalent ng 5.5mm stranded wire po

  • @robertnava3956
    @robertnava3956 ปีที่แล้ว +1

    idol? tanong lang sana idol'
    pwedi kaya ang dalawang aircon na 1/2 horsepower sa isang 20 amperes na breaker'' sana mapansin mo idol salamat

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      Kaya naman yan kaso wag nyo po pag sabayin..dapat may solo breaker sya.gaya neto po nasa link shope.ee/4ARghEjYMC

    • @robertnava3956
      @robertnava3956 ปีที่แล้ว +1

      maraming salamat idol ha' sa pagsagot idol
      pero kong pinagsabay yung dalawang aircon idol' ano kaya pwedi mangyari idol mag trip lang kaya ang breaker idol?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว +1

      D naman mag trip. Kaso pag ngka problema breaker mo..damay lahat.

    • @robertnava3956
      @robertnava3956 ปีที่แล้ว +1

      idol maraming salamat talaga idol laking tulong ng pagsagot mo idol
      papaliwanag ko nalang sa may ari idol'
      sanay marami kapang matulongan katulad kong baguhan idol god bless

  • @hatdogs4075
    @hatdogs4075 3 ปีที่แล้ว +1

    Sa 1.5 hp na air conditioner mas maganda ang 30 cb at 10 awg wire po. Kung hindi ka sigurado mag tanong sa isang engr.

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      Ng base lang po ako sa PEC Sir. Salamat po sa commento

    • @hatdogs4075
      @hatdogs4075 3 ปีที่แล้ว +1

      Kasi po sinabi naman po na dapat mas malaki po ang cb na ilalagay compare sa computation at sa wire naman po dapat may aditional .80 po

    • @LocalElectricianPH
      @LocalElectricianPH  3 ปีที่แล้ว

      Opo Sir. Basta pasok po sa 175% - 225% po ng FLC

    • @hatdogs4075
      @hatdogs4075 3 ปีที่แล้ว +1

      @@LocalElectricianPH kasi po sa 175percent 21.8ampere parin sabi sa mas malaki sa flc ang breaker mo

    • @hatdogs4075
      @hatdogs4075 3 ปีที่แล้ว

      @@LocalElectricianPH at ang available na breaker sa market is 30 amp na breaker

  • @Omanh703
    @Omanh703 4 หลายเดือนก่อน

    0.5 hp ACU ilang amp po ng cb need at anung wire #

  • @leonardaguirre2104
    @leonardaguirre2104 ปีที่แล้ว +1

    Ilang amperes po sa 1 hp

  • @RM-eu5et
    @RM-eu5et 2 ปีที่แล้ว +1

    Boss pwde po patulong
    Window type po na 0.6hp ilan amps po sa breaker at gano po kakapal ang wire?
    Window type 1hp ilan amps po at kapal ng wire?
    Salamat po

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว +1

      3.5mm wire 20A breaker po

    • @RM-eu5et
      @RM-eu5et 2 ปีที่แล้ว

      @@LocalElectricianPH 20A boss pra sa 0.6hp at 1hp?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Yes pwedi rin sa 1 hp. Pero e hiwalay nyo lng po breaker

    • @tamposph
      @tamposph ปีที่แล้ว +1

      @@LocalElectricianPH hello sir.. paano mag compute Ng main circuit breaker na my 16 branches(20A) .

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Dapat meron po kayo schedule of load Sir..mahabang computation po iyan..mahirap po e explain dito...pwedi kai mg message sa fb page

  • @rampats
    @rampats 2 ปีที่แล้ว +1

    Ano po breaker po ng 2hp at size ng wire gagamitin?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      30A at 5.5mm wire

    • @rampats
      @rampats 2 ปีที่แล้ว +1

      @@LocalElectricianPH sir may nkaabang na po wire para sa ac #12 at may sariling cb sa panel board.. Tanong ko lng sir kylangan ko pa rin bang mag dag2 ng breaker? Kung kylangan magdagdag pwed po ba yang 30amps na cb?

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Actually pwedi na jan ang #12 at 20A...pero f mg trip gawin mong 25...kaso wala naman 25 sa matket..kaya 30A nlng...pero f hindi mg trip sa 20A...goods na yan

    • @rampats
      @rampats 2 ปีที่แล้ว +1

      @@LocalElectricianPH salamat sir

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Welcome po

  • @jaysonmeneses965
    @jaysonmeneses965 2 ปีที่แล้ว +1

    hindi ba pwedend tignan n lng sa mismong unit kung ilang wattage kesa magcompute pa..dba nkasulat nmn kung ilang amperes yan acu

    • @LocalElectricianPH
      @LocalElectricianPH  2 ปีที่แล้ว

      Pwedi naman po..guide lng po ito as per Standard sa Philippine Electrical Code natin. F prefered nyo ang safety po.

  • @oldsongcalixtro7472
    @oldsongcalixtro7472 2 ปีที่แล้ว +1

    Watt/220=amperes

    • @leeedwardtayson9141
      @leeedwardtayson9141 หลายเดือนก่อน +1

      Depende, iba ang full load current at instantaneous current. Both expressed in Amperes(A). Pero magkaiba ang usage in formulas

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      Thanks sir

  • @twenfrigga1687
    @twenfrigga1687 2 ปีที่แล้ว +1

    Sir para sa 3hp o 4hp anong amp ng breaker mas ok?

  • @joeyparaon2682
    @joeyparaon2682 3 ปีที่แล้ว +1

    Sir pa help po,..0.75 po ang AC nmin ilang amp na breaker ang pede ko gamitin?

  • @alvindepedro918
    @alvindepedro918 ปีที่แล้ว

    Paano malalaman kung kaya ba ng 175 or hindi?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Testing Po ng actual Sir..pero usualy lower HP kaya po yan like 2hp below

  • @miguelhomero9762
    @miguelhomero9762 3 ปีที่แล้ว +1

    May tanong lang po Sir.
    pano po kung dalawang 1.5 hp window type na aircon pagsasamahin ko po sa iisang breaker pwede po yun?
    Salamat po Sir sana mapansin 🙂
    God bless po

  • @alvindepedro918
    @alvindepedro918 ปีที่แล้ว

    Paano po malalaman kung alin gagamitin 175% o 225% ?

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      Gagagana po yan Sir..base kasi yan sa standard ng PEC

  • @riconoodle7747
    @riconoodle7747 ปีที่แล้ว

    Master sa 2.5hp na aircon naman ano po dapat na breaker dyan?

  • @ptspinoytechnicalscience3495
    @ptspinoytechnicalscience3495 ปีที่แล้ว +1

    mali yang 225 percent! 250 dapat yan nasa PEC

    • @LocalElectricianPH
      @LocalElectricianPH  ปีที่แล้ว

      250 po f sa mga ilaw o general applianve receptacle Sir. 225 f AC . Nsa PEC po yan Sir

  • @LopeEusebio-p1d
    @LopeEusebio-p1d หลายเดือนก่อน

    Ipaliwanag mo maigi hindi Yong percentage na sinasabi mong percentage

    • @LocalElectricianPH
      @LocalElectricianPH  หลายเดือนก่อน

      Percentage po talaga yan Sir..nasa libro naman po ang guide sir.. salamat po...

  • @christiantomandao030
    @christiantomandao030 ปีที่แล้ว +1

    Bili ka