Installing a 1" Moen Flo Smart Water Monitor

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 พ.ย. 2024

ความคิดเห็น • 15

  • @dannynungaray4379
    @dannynungaray4379 6 หลายเดือนก่อน

    Great job. I have seen plumbers use a coupling on a soft copper then sweat a type L copper pipe to the Propress fittings for the Propress Tool

  • @gm1937
    @gm1937 2 หลายเดือนก่อน

    Great video can you please explain the issue with the pipe that might cause a leak?

    • @pershingplumbing9007
      @pershingplumbing9007  2 หลายเดือนก่อน

      @@gm1937 propress sometimes will crush type m copper too much and cause a tiny little seepage on the propress fittings

  • @tomdale1313
    @tomdale1313 6 หลายเดือนก่อน

    good explanation on your installation, awesome you called them...all the tips and tricks are very helpful, thxs for sharing...

  • @jeffreyplumber1975
    @jeffreyplumber1975 4 หลายเดือนก่อน

    Nice job Type M not rated for press ?

    • @pershingplumbing9007
      @pershingplumbing9007  4 หลายเดือนก่อน

      @jeffreyplumber1975 yes u can press type m. Old type m gets really thin over time so you gotta be careful. Sometimes it's too thin and the fitting will seep

  • @PlumbThumbs
    @PlumbThumbs 6 หลายเดือนก่อน

    Hell yeah!

  • @JohnJohn-mz3kh
    @JohnJohn-mz3kh 6 หลายเดือนก่อน

    GOOD JOB SEE YOU NEXT TIME

  • @aaronbaraiya3692
    @aaronbaraiya3692 6 หลายเดือนก่อน

    Just wondering if there's water in a pipe how could one get it out to solder?

    • @MisterWeekday
      @MisterWeekday 6 หลายเดือนก่อน +1

      Many methods. Suck it out with vacuum or a tube, Freeze the pipe (This is used if you don't want to turn off water to the building you're working on like large commercial facilities), use a jet sweat (inserts into the pipe and expands to prevent water from coming back when soldering on a fitting. Usually used with an open ended fitting so you can remove the jet sweat), Shove some white bread into the pipe to absorb the water (The bread will hopefully dissolve completely when reinstating water), and many more!

    • @pershingplumbing9007
      @pershingplumbing9007  6 หลายเดือนก่อน

      jet sweat, put in a spray bottle head and spray it out, those are what i do, or use a shop vac

  • @workingshlub8861
    @workingshlub8861 6 หลายเดือนก่อน

    thought you are not supposed to have a PRV upside down

    • @pershingplumbing9007
      @pershingplumbing9007  6 หลายเดือนก่อน

      doesnt matter as long as you have the direction of flow in the right direction

  • @charliegodinez9655
    @charliegodinez9655 5 หลายเดือนก่อน +1

    Insurance companies are getting intrusive now. Good for plumbers I guess

  • @Longeno55
    @Longeno55 3 หลายเดือนก่อน

    Another cool install. These meters seem to be getting way too smart LOL. You obviously got this though bro!