Gas Furnace Combustion Analysis Training with Tyler Nelson!

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ก.ค. 2024
  • In this HVAC Training Video, Tyler Teaches on: What is Combustion, How Does Excess Air affect Combustion Readings, 7 Functions of Highly Effective Combustion Analyzers, CO Safety, What do Analyzer Readings Mean, Importance of Checking/Adjusting Gas Pressure, Draft and Cross Contamination, Commissioning, Diagnostics, Testing Procedure, and Cracked Heat Exchanger Verification! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    Sauermann Links:
    Facebook: / sauermannamericas
    Linkedin: / sauermann-na
    Instagram: / sauermann_americas
    Web: sauermanngroup.com/en-US
    Trade-in: sauermanngroup.com/en-US/node...
    Training: sauermanngroup.com/en-US/node...
    Sauermann Tools at TruTechTools:
    Save 8% on Tools from www.trutechtools.com when using code "acservicetech"
    Si-CA 030: www.trutechtools.com/sauerman...
    Si-CA 130: www.trutechtools.com/sauerman...
    Si-CA 230: www.trutechtools.com/sauerman...
    Gas Manometer: www.trutechtools.com/sauerman...
    CO Monitors:
    AimSafety PM100-CO Carbon Monoxide Single-Gas Monitor: www.trutechtools.com/Macurco-...
    Sensorcon INS2-CO-02 Inspector Industrial Portable CO Monitor: www.trutechtools.com/sensorco...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Timestamps:
    0:00 - Craig Introduces Tyler
    0:16 - Chapter 1 Introduction
    3:50 - Chapter 2 Situational Awareness
    7:53 - Chapter 3 Why you are here
    16:24 - Chapter 4 What is combustion
    22:16 - Chapter 5 Excess Air
    23:46 - Chapter 6 Seven Functions of Highly effective Analyzers
    24:47 - Chapter 7 CO Safety
    35:36 - Chapter 8 What do these readings mean
    38:49 - Chapter 9 Importance of checking gas pressure
    46:40 - Chapter 10 Draft and cross contamination
    51:55 - Chapter 11 Commissioning
    53:32 - Chapter 12 Seasonal Maintenance
    56:19 - Chapter 13 Diagnostics
    1:05:49 - Chapter 14 Testing Procedure
    1:11:50 - Chapter 15 Combustion Efficiency
    1:15:55 - Chapter 16 Cracked Heat Exchanger Verification
    1:22:18 - Chapter 17 NCI and measureQuick
    1:25:36 - Chapter 18 Si-CA analyzer line features
    1:33:24 - Chapter 19 Thank You
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

ความคิดเห็น • 54

  • @user-ix2oc5zs7d
    @user-ix2oc5zs7d 8 หลายเดือนก่อน +4

    Tyler is awesome. We had him at our shop.

  • @voltgan
    @voltgan 5 หลายเดือนก่อน +1

    Awesome re-education on the value of using a combustion analyzer
    Thanks for this video

  • @user-pf9ig8wc1c
    @user-pf9ig8wc1c 8 หลายเดือนก่อน +6

    Thank you very much for all this information! it inspired me to get this tool for my new one man company. I understand the general idea of what this tool does and how it's done, however I would like to see videos of how it's used in the field. I noticed the Manuel ,and what this video says is a bit different . so I to be honest the Manuel doesn't have a lot go info as far as instructions. I would love for you Craig to show a how to , step by step, how to use this tool. examples of when to start the furnace up, when to have the probe in, when doing a heat exchanger test. a pass and fail. how long should a test take and so on. again I thank you for all of your content and all your help! God Bless!

  • @asalazar7696
    @asalazar7696 8 หลายเดือนก่อน +2

    Greatly appreciate these type of videos thanks for all the good work you guys do to help technician

  • @BasedNj
    @BasedNj 8 หลายเดือนก่อน +2

    I did your preventative maintenance for AC 2023

  • @UncleEarlHeatingAirCondition
    @UncleEarlHeatingAirCondition 10 หลายเดือนก่อน +2

    Great Presentation Tyler!!
    Earl

  • @jimgill5706
    @jimgill5706 10 หลายเดือนก่อน +4

    Great presentation. Thanks.

  • @hvacrwrld1402
    @hvacrwrld1402 7 หลายเดือนก่อน +1

    I FGA every unit I isolate. Be it for a strip or cleaning a condensate trap. Always go home with a clear conscience. That flue piped to the basement is paying for death.
    The UK has very high standards; retrain every 5 years mandatory. Its bloody hard work here hence £90 per hour rates.

  • @ToddRiva
    @ToddRiva 5 หลายเดือนก่อน +2

    Great video, thank you for sharing. As a fellow instructor I can appreciate sharing good information to the instructors and Technicians. I was wondering if there is a way to get a copy of the venting images shown in the beginning of the training video.

  • @brianmcdermott1718
    @brianmcdermott1718 10 หลายเดือนก่อน +2

    Great presentation. Thank you .

  • @monoitalian
    @monoitalian 9 หลายเดือนก่อน

    Great video thanks for sharing

  • @eastcoast186
    @eastcoast186 10 หลายเดือนก่อน +3

    Very informative video thank you and Craig 👍👍👍👍👍

  • @mauroaparicio1855
    @mauroaparicio1855 10 หลายเดือนก่อน +3

    great information

  • @kingpoopthe7th
    @kingpoopthe7th 7 หลายเดือนก่อน +1

    Great presentation, very digestable for a novice. As a home owner, i wonder why we use gas in residential applications at all? I gather price is the main factor but it seems to me that electric system like heat pumps are far safer and qsuming a competent installer, better for ghg emissions

  • @brianbray5397
    @brianbray5397 6 หลายเดือนก่อน +1

    There is some push back on the pvc vs. pp change over. PP has it's own problems such as it's prone to oxidation in some environments and it doesn't withstand heat as well as pvc.

  • @roydaugherty2971
    @roydaugherty2971 6 หลายเดือนก่อน +1

    I am certified in this been doing it for many many years in Los Angeles Orange County retired now people talk about cleaning up the atmosphere I did there are many other safety factors

  • @SombraLocs
    @SombraLocs 9 หลายเดือนก่อน +3

    Why are those carbon monoxide detectors allowed to be sold if they’re not effective at all? Can we sue them?

  • @joshua-the-seer8494
    @joshua-the-seer8494 10 หลายเดือนก่อน +3

    Also, please make an on the job demonstration. And explain the importance of the other gases in Combustion Analysis

    • @tyty3022
      @tyty3022 10 หลายเดือนก่อน +1

      Great feedback. This is where coming to one of my live classes comes in where we do hands on. I do them all over the Americas.

    • @joshua-the-seer8494
      @joshua-the-seer8494 10 หลายเดือนก่อน

      @@tyty3022 when & where?

  • @santhoshmonteiro1666
    @santhoshmonteiro1666 10 หลายเดือนก่อน +2

    Can you please make a video on chamber vacuum sealer machine. Please❤️

  • @brianf2401
    @brianf2401 10 หลายเดือนก่อน +4

    Great presentation gentlemen! Curious on your thoughts about adding a valve on the inlet air (NCI often talks about this)? Also - I'm in canada - we have different codes as far as penetrating the flue pipes. You mentioned PVC is going away, but we're required to use the ULC S636 rated PVC - not sure if that's going as well - or anything else (polypro) rated to s636. the pipe manufacturers have a fitting for combustion analysis that is basically a 2x2x1/2 FPT fitting. Will the threads of the cone thread into this ok? I previously carried around a 1/2 plug cap that I drilled a little hole in to put the probe into because I was worried about the threads not matching. Thanks again! Appreciate your hard work!

    • @marconantel7735
      @marconantel7735 10 หลายเดือนก่อน

      Unrated PVC is going away. 636 is rated and listed as a venting material. Polypropylene (polypro, centrotherm, and others) are also rated, and some glue “PVC” products are as well, 1738 and 636 for example. As approved fittings and systems, they offer test ports. Great idea in my opinion, use approved fittings and avoid liability problems

  • @theusername07
    @theusername07 9 หลายเดือนก่อน

    Is there a resource to download the power point presentation as a pdf

  • @woogiewaters
    @woogiewaters 10 หลายเดือนก่อน +1

    I understand how a high setting of manifold pressure could increase the dimensions, particularly the length, of the flame, reducing distance to the heat exchanger walls until the point of causing flame impingement. But, at 40:02, Tyler reads from the slide that a LOW setting of manifold pressure can cause flame impingement. How would a decrease in flame dimension cause impingement? Have I misunderstood somewhere or is it just an error on the slide?

    • @tyty3022
      @tyty3022 10 หลายเดือนก่อน +2

      Error on tbe slide my friend. Transposition error. Apologies.

  • @drohvac4583
    @drohvac4583 8 หลายเดือนก่อน

    Install those boards often. Just half to rotate them sideways and will not have to extend any wires!

  • @deltaf222
    @deltaf222 4 หลายเดือนก่อน +1

    How does someone get a hold of Tyler? Anyone?

  • @reinhardhurt50
    @reinhardhurt50 4 หลายเดือนก่อน

    What training material are those chapter references at the top of the screen from?

  • @RTFMhvac
    @RTFMhvac 9 หลายเดือนก่อน +1

    I’ve always heard to not have your analyzer in the flue during light off due to it damaging your sensors from the high CO on ignition, is this not true?

    • @marconantel7735
      @marconantel7735 9 หลายเดือนก่อน

      Little of both. Newer machines have a “cutoff” threshold you can program to protect them from spikes, many older machines did not just make sure yours does, and it’s programmed to work!

    • @tyty3022
      @tyty3022 9 หลายเดือนก่อน

      It was true. However, with the Sauermann SICA combustion analyzers we give you a robust 8000 PPM limit with programmable pump cut off so you won’t over range your CO sensor. That is why I want those who use ours to test at all firing rates. This is another reason why NCI uses us as well as a great deal of others switching to us. We also have sensor life indicators and end of life indicators plus other class leading features.

  • @garypoplin4599
    @garypoplin4599 8 หลายเดือนก่อน

    38:54 - I have a challenge for you: how do I clock the meter in a restaurant with four RTUs, two gas griddles (one - 2 foot and one 3 foot) and one two eye burner?

  • @joshua-the-seer8494
    @joshua-the-seer8494 10 หลายเดือนก่อน +1

    29:11 Wouldn't keeping the hoses attached mean that the startup would negate any contamination from past analyses left over in the hoses?

    • @tyty3022
      @tyty3022 10 หลายเดือนก่อน +3

      Great question my friend. If you had kept the hoses attached at start up you run the risk of pulling the remnants of a previous combustion test into the analyzer and thus skewing the auto zero process. Auto zero is always done with no probes or hoses attached and away from potential contaminants.

    • @joshua-the-seer8494
      @joshua-the-seer8494 10 หลายเดือนก่อน +1

      @@tyty3022 I appreciate the quick replies. Let me know where I can learn more. I'm also looking to upgrade from my Testo analyzer

  • @jevianfe
    @jevianfe 7 หลายเดือนก่อน +1

    Nice training, but I see only CO reading on your combustion examples, I didn’t see COaf, on you combustion examples.

    • @tyty3022
      @tyty3022 7 หลายเดือนก่อน +1

      It was farther down on the display. You can change what you see and in what order on the analyzer. I have since moved it up as number 2 under O2.

  • @caru3257
    @caru3257 9 หลายเดือนก่อน

    How about proves? No mani.

  • @ROCKETKOBE
    @ROCKETKOBE 10 หลายเดือนก่อน

    Hi!😊

  • @Firehawk841
    @Firehawk841 8 หลายเดือนก่อน +1

    this was more a selling piece for that too.. my fieldpiece cat85 is way better than that tool.

  • @CybekCusal
    @CybekCusal 10 หลายเดือนก่อน +6

    It's too general, not enough specifics. Also he just talks and never actually says anything useful.

    • @timdestasio3367
      @timdestasio3367 10 หลายเดือนก่อน +8

      If you didn't find anything useful then you are unteachable. Hopefully you're happy as a barista.

    • @CybekCusal
      @CybekCusal 10 หลายเดือนก่อน +2

      @@timdestasio3367 nobody cares what you have to say.

    • @timdestasiohvac
      @timdestasiohvac 10 หลายเดือนก่อน +3

      @@CybekCusal 👏👏👏 I'll have a large black, 1 sugar please and thank yoy.

    • @CybekCusal
      @CybekCusal 10 หลายเดือนก่อน

      @@timdestasiohvac you guys have no life but to be Internet small d trolls

    • @davidthomas2585
      @davidthomas2585 10 หลายเดือนก่อน +1

      What would you have added?