DIC Microscopy | Differential interference contrast | DIC vs Phase contrast.

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 มิ.ย. 2024
  • DIC is also termed as Differential interference contrast Microscope. This microscopy technique uses the polarizer and a special type of prism to split light into two rays (or two waves) known as the e ray and the o ray. Both the rays are separated by a small distance known as the shear distance. There is also a phase difference between both the rays. Both the rays passes through the specimen and further hits the second prism which combines them into a single ray. finally the image observed has one bright region and other dark region. the physics involved in DIC microscope has been discussed in detail. Finally we also compare DIC and phase contrast microscope as both of them can be confusing.

ความคิดเห็น • 22

  • @asphyx9
    @asphyx9 ปีที่แล้ว +4

    Thank you - one of the best explanations I have seen on DIC

  • @nourelhoudabenyahia257
    @nourelhoudabenyahia257 ปีที่แล้ว +2

    Amazing explanation!

  • @tarunkumarpalli7580
    @tarunkumarpalli7580 2 ปีที่แล้ว +2

    Wow dude, its so, clear to understand

  • @phamdung3884
    @phamdung3884 ปีที่แล้ว

    This really is a simple explanation. Thank you so much! ^^

  • @potharlaanil5621
    @potharlaanil5621 2 ปีที่แล้ว +2

    I salute for your explanation..

  • @yixuanshen8366
    @yixuanshen8366 2 ปีที่แล้ว +3

    Dude, you are saving my life

  • @peterallen8573
    @peterallen8573 7 หลายเดือนก่อน

    Good explanation.Thank you.

  • @shivanin8708
    @shivanin8708 2 ปีที่แล้ว

    Thank you so much!!

  • @keshaxLOVEx
    @keshaxLOVEx ปีที่แล้ว +1

    very useful thank you

  • @moneeralhalabi1272
    @moneeralhalabi1272 ปีที่แล้ว

    Great work

  • @christeenamathew8606
    @christeenamathew8606 ปีที่แล้ว +1

    crystal clear 🤟

  • @CHAMPIONSBio
    @CHAMPIONSBio 2 ปีที่แล้ว

    Thanks a lot bro .....

  • @anindita6913
    @anindita6913 2 ปีที่แล้ว

    Excellent

  • @nihalhathaway4089
    @nihalhathaway4089 ปีที่แล้ว

    thank you very much! Isn't the condenser after the polarizer, between prism and stage?

  • @pak2966
    @pak2966 3 หลายเดือนก่อน

    Are the two Nomarski prisms exactly the same (just inversed) or do they differ?

  • @gregvisioninfosoft
    @gregvisioninfosoft 5 หลายเดือนก่อน

    Does anyone here have broad experience using DIC? I was hoping I could ask a question. I am trying to understand this in a general manner. From this video at 0:06 timestamp, we see that two (I assume 'matched') 'DIC Nomarski Prisms' are required. One below the sample, and one above. Apparently there is no concept of a single one-size-fits-all 'DIC Nomarski Prism. As when I look at actual part numbers, for example in the Olympus microscope line, there are several of these: U-DIC-10, U-DIC-20, U-DIC-40, U-DIC60, and U-DIC100. What I notice in the differing catalog numbers is what appears to be the 'Magnification' is different. This implies the DIC Nomarski Prism is somehow 'optimized' to a given magnification. My first question is - what actually causes these DIC Nomarski Prisms to be different in their manufactured characteristics? In other words, if one were to hold both a U-DIC10 and compare it to a U-DIC20 - how exactly would they be different?

  • @user-yj6ye4zk8v
    @user-yj6ye4zk8v ปีที่แล้ว

    5:34

  • @JongcheolLee
    @JongcheolLee 2 ปีที่แล้ว

    Wow best video ever explaining DIC

  • @mototajo8911
    @mototajo8911 2 ปีที่แล้ว

    Thanda

  • @user-yj6ye4zk8v
    @user-yj6ye4zk8v ปีที่แล้ว

    6:16