  • Along with the shuttle valves, another critical piece in every Load Sense system is the pressure compensated flow control valves (also known as pressure compensator valves) in the valve section. These valves serve an important role in controlling the rate of flow through the directional valves, so that even as the pump changes its flow rate (due to the load sense signal), the flow to the actuators remains constant. To continue learning, you can buy our load sense working animations on our website www.lunchboxse... and watch all the video in our load sense playlist • Load Sense
    We have more great hydraulic videos coming out every week. If there's a hydraulic (or electrical) topic you'd like to see us cover, leave a comment. And as always, "Thanks for watching!"

ความคิดเห็น • 35

  • @msm8212
    @msm8212 3 ปีที่แล้ว

    A heartful thanks to your videos. I believe this video shows about the pre comp system and not sure how this flow controlled evenly with heavy and light load.

    • @terryjefferson747
      @terryjefferson747 3 ปีที่แล้ว

      i guess Im randomly asking but does any of you know a method to get back into an Instagram account..?
      I stupidly forgot the login password. I would appreciate any assistance you can offer me

    • @austinjalen2789
      @austinjalen2789 3 ปีที่แล้ว

      @Terry Jefferson Instablaster =)

    • @terryjefferson747
      @terryjefferson747 3 ปีที่แล้ว

      @Austin Jalen i really appreciate your reply. I found the site thru google and I'm in the hacking process now.
      Seems to take a while so I will reply here later when my account password hopefully is recovered.

    • @terryjefferson747
      @terryjefferson747 3 ปีที่แล้ว

      @Austin Jalen it did the trick and I finally got access to my account again. I'm so happy:D
      Thanks so much, you saved my account :D

    • @austinjalen2789
      @austinjalen2789 3 ปีที่แล้ว

      @Terry Jefferson No problem :D

  • @plcprofessor
    @plcprofessor 7 ปีที่แล้ว +4

    Absolutely excellent...keep up this excellent endeavor!!!

  • @rickardjonsson4526
    @rickardjonsson4526 5 ปีที่แล้ว +1

    Isnt the compensator moving the wrong way in this simulation? It moves from from center to the left, shouldnt it move to the right?

  • @inventpal6176
    @inventpal6176 5 ปีที่แล้ว +1

    Why are you not answering every ones question, "What hydraulic software are you using"?

    • @lunchboxsessions
      @lunchboxsessions  5 ปีที่แล้ว

      We're so busy making new content for lunchboxsessions.com that we don't often check in on the TH-cam channel. The short answer is that we build everything - the art, the animation, the code - from scratch using our own in-house tools. We've got some more information about how we make these simulations here: www.lunchboxsessions.com/help/what-software-do-you-use-to-make-the-simulations

  • @danalex2991
    @danalex2991 7 ปีที่แล้ว +1

    These are really insightful videos that answer exact questions that I always had .
    Thank you so much! subscribed !

  • @pinalbaraiya7625
    @pinalbaraiya7625 7 ปีที่แล้ว

    nice animated explanation, i could understand this valve. Could i please know which software it is used to create this animation?

  • @michaelcostello6991
    @michaelcostello6991 5 ปีที่แล้ว +1

    Greatttt

  • @oliverramos4454
    @oliverramos4454 6 ปีที่แล้ว

    nice. what software used to create this animation?

  • @TananBaboo
    @TananBaboo 6 ปีที่แล้ว

    What software are you using?

  • @licensejeon
    @licensejeon 4 ปีที่แล้ว

    What software are you using?

    • @lunchboxsessions
      @lunchboxsessions  4 ปีที่แล้ว

      We've got some information about how we make these simulations here on our website: www.lunchboxsessions.com/help/what-software-do-you-use-to-make-the-simulations

  • @t4sturm
    @t4sturm 7 ปีที่แล้ว

    What's an example of what a circuit like this would be on?

    • @lunchboxsessions
      @lunchboxsessions  7 ปีที่แล้ว +1

      A load sensing, directional valve bank, complete with pressure compensators in each valve section is very common on a road grader or an excavator.

  • @waqarkhan-pz3sw
    @waqarkhan-pz3sw 7 ปีที่แล้ว

    Ok it is a good animation to get the idea for pressure compensation system but i have one question that how flow equally distributed to both sections as we know that flow always find low resistance path now if we move both valves in all over above or down position then surely in your example the more or even all pump's flow will move to second section which have 16000 lbs load which is resistance.???

    • @sathishr7774
      @sathishr7774 4 ปีที่แล้ว

      That is where the pressure compensator comes into play. It will close accordingly thereby restricting the flow to the load .

    • @sandeepsharma7217
      @sandeepsharma7217 4 ปีที่แล้ว

      @@sathishr7774
      But how?
      In this animation, it is not clear how pressure compensator is restricting pressure in second half section. With my current understanding, it is logical that all the flow must transfer to the 2nd section due to less resistance.

    • @sathishr7774
      @sathishr7774 4 ปีที่แล้ว

      @@sandeepsharma7217 there is a spring in the compensator that closes it accordingly. There is a separate video in lunchbox session

  • @licensejeon
    @licensejeon 4 ปีที่แล้ว

    Absolutely excellent

  • @BrendonVorio
    @BrendonVorio 3 ปีที่แล้ว

    These vids are great. I’m trying to find out a name/explanation for a system where your source flow would be 10gpm. You would want all of that 10gpm to be supplied to a circuit, until another circle calls for 5gpm of that flow. This would in turn operate both circuits at the same time, tho both would be operating at 5gpm while that one circuit is active and full flow restored once its inactive.

    • @aidwilli
      @aidwilli 3 ปีที่แล้ว

      priority flow divider

    • @BrendonVorio
      @BrendonVorio 3 ปีที่แล้ว

      @@aidwilli thanks! I’ve looked into those, but it seems like it splits the incoming flow even when one of the systems is at rest. I’m trying to rob partial flow from the incoming flow, but yet when that system is at rest, I’d want 100% flow to provide the other system.

    • @aidwilli
      @aidwilli 3 ปีที่แล้ว

      @@BrendonVorio What exactly is your system? Fixed or variable displacement pump?

    • @BrendonVorio
      @BrendonVorio 3 ปีที่แล้ว

      @@aidwilli
      Fixed

    • @aidwilli
      @aidwilli 3 ปีที่แล้ว

      @@BrendonVorio you could try a power steering priority valve. Flow is sent to excess flow port at only ~ 150 to 250psi drop when controlled flow port is blocked. Try searching Eaton vle type in line priority valve for an example. You can pull one off of a tractor or other mobile hydraulic machine if you can verify valve gpm rating is enough.

  • @vincenzovitiello5745
    @vincenzovitiello5745 7 ปีที่แล้ว +2

    Great work!!! I have only one question. So if you have only one load in your circuit, you don't need a pressure compensator, right? Just the load sensing pump is enough to ensure a constant deltap across the directional valve??