That first piece is an apron flashing 😂 that’s not counter at all… you didn’t cut a riglet in the brick… you have to cut the brick a 1/2 inch or more then install a counter in that groove that comes down over the piece you installed… you can’t caulk the top of that piece it will leak in 5 years…
I did my roof the way you showed and the rain ran down the side of the chimney and underneath the shingles. You have to put something on the chimney that goes over the ones you showed. Cost $6000 to repair. Please give contact information. My lawyer has to talk with your lawyer.
All I do is flashing and custom sheet metal items dormers. standing seam roofs. Etc. It's ALL WRONG sorry man I love my job and your lesson was a slap in the face
Crazy the table on the lower side of the chimney that you caulk to your flashing is going to trap water someone will definitely be repairing this in the future
Would you use quarter-size dabs of adhesive instead of a continuous bead or would you leave the flashing on top of the shingles completely to allow water that flows down the chimney wall onto the flashing to drain onto the shingles unimpeded? It seems that putting shingles on top of that bottom flashing would allow for a horizontal movement of water underneath the shingle to go onto the deck at both ends.
From a REAL roofers perspective.keep.doing it that way, wel will repair it for a living. What a joke!!!!!!!!!!!
That's not how I would do it
This is not right at all does no one teach this new generation anything 😂
Wuao😅 people. If you’ll don’t know how to do the job. Please don’t record it.
That first piece is an apron flashing 😂 that’s not counter at all… you didn’t cut a riglet in the brick… you have to cut the brick a 1/2 inch or more then install a counter in that groove that comes down over the piece you installed… you can’t caulk the top of that piece it will leak in 5 years…
When you learn to do it better, you'll stop cutting into the more permanent structure
This video is not the best way to flash a chimney, but neither is the way you were taught
He did u dnt c the brick cut
There's 100 things wrong with this. Please take this video down your company will get sued
Wow.... That is not how you properly flash a chimney
I did my roof the way you showed and the rain ran down the side of the chimney and underneath the shingles. You have to put something on the chimney that goes over the ones you showed. Cost $6000 to repair. Please give contact information. My lawyer has to talk with your lawyer.
I was expecting a builder bob not a handy manny the things people film themselves doing
What fail job people don’t do this please
Por favor no lo hagan así eso es una porquería, NO GOOD 👎👎👎👎👎👎
Who guarantees that at 2:32 no water will pass from below!
I stared doing all my chimneys this way. Saves so much time and haven’t gotten a single call back since I turned my ringer off
All I do is flashing and custom sheet metal items dormers. standing seam roofs. Etc. It's ALL WRONG sorry man I love my job and your lesson was a slap in the face
This is terrible. So many problems with the flashing, let alone the adhesive he used. If you are new and trying to learn, this is what not to do.
Explain it
Everyone says it's wrong but nobody explains what's actually wrong and the proper procedure
This isa fail
Crazy the table on the lower side of the chimney that you caulk to your flashing is going to trap water someone will definitely be repairing this in the future
Would you use quarter-size dabs of adhesive instead of a continuous bead or would you leave the flashing on top of the shingles completely to allow water that flows down the chimney wall onto the flashing to drain onto the shingles unimpeded? It seems that putting shingles on top of that bottom flashing would allow for a horizontal movement of water underneath the shingle to go onto the deck at both ends.
Are you kidding, 42 yrs in made all my chimney flashings outl of 24ga. and rivits and solder, this cheap bullshit!
Nice video - what is the make of the caulking ??
Thats not good dude. You have to overlap 1.5 to 2 inches.
Is it done like others might do? No but this will work. If youre such a good roofer why are you watching this lol
What no counter?
Por qué ke pones silicon debajo
Today must be your first day ! That is 💯 wrong.
This is perfect. I don’t want to do it the right way anyway. So all the haters in the comments can stuff it.
Everyone on his ass 😂😂😂😂😂
pobre compa no sabe Nilo k está aciendo
Aa
I 😊
😂😢😅
Super helpful video, thanks
Good job