HVAC Basics: Service & Troubleshoot - Testing a compressor with a shorted winding & Capacitors

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ก.ค. 2024
  • This video shows what happens when the winding are shorted together but not shorted to ground. We also look at some reasons for capacitors.

ความคิดเห็น • 14

  • @nixcoolfix
    @nixcoolfix 4 ปีที่แล้ว +1

    "Common, start, wun" lol. Good video man. Dammit Ronnie!

  • @benjaminday3868
    @benjaminday3868 5 ปีที่แล้ว +1

    I wish he spoke a little slower, but he is knowledgeable. Thanks for the video.

  • @waitemc
    @waitemc 5 ปีที่แล้ว

    I got 3 of these scroll compressors daisy chained with 5 sec delay between each . They are my home shop air compressors . Extreamly quiet and plumbed them in such a way to dump into a catch can above them to capture all the oil which by way of them extra small copper lines .030 in inner diameter links back to intake reoiling all 3 continually . Then to an old condenser to a water drain then to 30 gal tank. This bud just helped me dig through a pile of these compressors a local HVAC were scrapping. Fun prodject. Fyi the amount of air from each produce the same as a C.H piston compressor . So this series up is 3 times faster 100 times quieter

  • @diegomagallon321
    @diegomagallon321 6 ปีที่แล้ว

    Excellent lesson

  • @waitemc
    @waitemc 5 ปีที่แล้ว +2

    Dang it Ronnie

  • @jimbola77
    @jimbola77 8 ปีที่แล้ว

    very nice great video!!!

    • @edisonhvac
      @edisonhvac  8 ปีที่แล้ว

      +jimbola77 thanks for the comment and thanks for watching!

  • @derrickhill2419
    @derrickhill2419 8 ปีที่แล้ว

    Great job

    • @edisonhvac
      @edisonhvac  8 ปีที่แล้ว

      +derrick hill thanks!

  • @r4ym1n13
    @r4ym1n13 8 ปีที่แล้ว

    nice video

  • @woodenboatclassroom7172
    @woodenboatclassroom7172 6 ปีที่แล้ว

    Can you help me? I have Ductless system one 18 k and two 9 k the 18 one is woking ok but the two 9 are not working. When I turn them on the fan comes on but they not energise the out door unit can you give some advise on what could be the most likely cause of the problem. Thanks

  • @carlosportillo8863
    @carlosportillo8863 5 ปีที่แล้ว

    Does a Locked rotor compressor need to be replaced?

  • @markllamera5121
    @markllamera5121 7 ปีที่แล้ว +2

    If you use ohms don't touch with your hand the pin of multimeter..our body have current..

  • @justinfrias9030
    @justinfrias9030 5 ปีที่แล้ว

    He doesn’t know the compressor says the cap size it calls for on it?