The Simplest Soft Starter!

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ก.ย. 2024

ความคิดเห็น • 341

  • @ProjectFarm
    @ProjectFarm 4 ปีที่แล้ว +82

    Very useful video. Thank you for all the time and effort you put into it! Always a thumbs up and looking forward to the next video!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +6

      Thanks for watching! I greatly enjoyed yesterday's video!

    • @JT-lq4yd
      @JT-lq4yd 4 ปีที่แล้ว +6

      I subbed to PF for the excellent and valuable info on his videos, now I'm finding out he watches electronicsNmore videos... I will have to subscribe to electronicsNmore(when i finish this comment) for the same useful information as PF does and as shown in this video.

    • @94crocky
      @94crocky 2 ปีที่แล้ว +2

      @@JT-lq4yd exactly my thoughts. A great compliment to have Project Farm comment on your video.

    • @shanefages
      @shanefages 11 หลายเดือนก่อน

      Hey it’s project farm lol I watch your vids all the time man

    • @davidyummus6259
      @davidyummus6259 11 หลายเดือนก่อน

      Did you make one ?

  • @benhahaj8826
    @benhahaj8826 ปีที่แล้ว +6

    Man thats all I need? I knew there was a way to make one I spent atleast 3 hours scouring the web, I even went over to chatgpt and asked them boys. I just can't believe no one else made this video!

  • @BillEngel-kr1cv
    @BillEngel-kr1cv 29 วันที่ผ่านมา

    This is awesome. I was about to purchase a costly soft start for my little generator to run the RV 12k AC. I decided to try this for $20. It works perfectly!! I didn't have to climb on the RV roof, take off the shroud....none of that hassle. If you need a soft start... do this!

  • @SuperWhizy
    @SuperWhizy 2 ปีที่แล้ว +8

    Love your "schematic"; unorthodox but effective at clearly explaining the role of the grey box. Keep at it!

  • @Miata822
    @Miata822 3 ปีที่แล้ว +30

    Wonderful video. I used NTC thermistors in a commercial application to start high power DC cooling fans in an application that used a switch mode power supply sometimes. Mouser carries a wide assortment of these devices. Two tips on their use:
    Avoid the urge to automatically oversize these components. Choose an amperage rating just above your real load (fused correctly, of course).
    Secondly, these things get quite hot. Ensure they don't cause thermal damage to your wires but don't actively cool them. Resistance increases when they are cooled. I used a delay-on-make relay to cut the thermistors out of the circuit once the fans had started.
    A note on practical use. Once you turn the load on and get it running the thermistor's resistance drops. When you turn the load off the resistance will remain low until the thermistor cools. Switching the load off then immediately back on again before the thermistor cools will likely overload your power supply or inverter. That is part of the reason I used the time delay relay, so that the fans could cycle on and off with the thermistors being cool for each start.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +4

      Yes, you cannot cycle on and off quickly. The component needs to cool at least 30 seconds. Thanks for watching!

  • @eldiony45360
    @eldiony45360 หลายเดือนก่อน +1

    Thanks dude u just safed be alot of time and money well not that much time because ive been researching for a while but still i now know
    U got ur self a new like and a new subscriber

  • @KristoferTravelsHomesteading
    @KristoferTravelsHomesteading 3 ปีที่แล้ว +14

    This works great. I made this device exactly like yours. I have an off grid system and my new fridge was tripping my inverter all the time because of the big surge when it starts up. Ever since I installed this running on just the 5 ohms it has not tripped the inverter. Thank you thank you.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Glad it helped! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites. Thank you
      th-cam.com/users/electronicsnmoreplaylists

    • @stevej.6674
      @stevej.6674 3 ปีที่แล้ว

      I have the exact same problem with my new 240v fridge....probably going to try & make one of these also.

    • @amlanganon
      @amlanganon 3 ปีที่แล้ว

      @@stevej.6674 good day!! how did it go? what thermistor did you buy... i have same problem with my 220v 150 watts fridge..always trips the inverter after it wakes from cycle..

  • @natvega1
    @natvega1 2 ปีที่แล้ว +5

    I made one here in Puerto Rico, all I could find was a 10D-20, the fridge at start up is 8 amp and 1.5 amp running, I have a chinese inverter without any info on it of amp rating. The fridge with this 10D-20 starts up with no problem with one car battery and the small inverter, the battery remains at 12.1 after one hour even without solar, so I would say that this device does curve the inrush current well enough to power your fridge at startup with a cheap inverter.

    • @cafepuya
      @cafepuya ปีที่แล้ว

      Eso quiere decir que puedo hacer que el compresor de una nevera grande arranque con una planta pequeña??

    • @natvega1
      @natvega1 ปีที่แล้ว

      @@cafepuya primero tiene que medir el ampere de arranque luego el ampere del motor despues del arranque, si el ampere de arranque es de 11 ampere y luego 6 ampere corriendo, tienes que conseguir un inrush current limiter segun el consumo de arranque y el consumo del motor despues del arranque entonces si con una planta pequeña cual alcanza los amperes del motor despues del arranque, si funciona ya lo e visto muchas veces.

    • @cafepuya
      @cafepuya ปีที่แล้ว

      @@natvega1 Es que tengo una Sportsman GEN1000i de 1000W-800w mi nevera dice en el sticker de adentro 6.5A.. A la planta le tengo un kill-a-watt para ver el consumo de watts y cuando está corriendo veo que usa 120w a 230w aveces marca 0.0 como si estuviera apagada.. pero de momento cuando el Compressor arranca.. llega como a los 8Amperes y la planta de apaga. No se si con este truco pueda solucionar eso.

    • @natvega1
      @natvega1 ปีที่แล้ว +1

      @@cafepuya si, si hace este inrush current limiter tu nevera va funcionar con el sportman, enviame tu email y te envio una photo de como se hace, el limiter cuesta $6 y se encuentra en cualquier tienda de venta electronico

    • @natvega1
      @natvega1 ปีที่แล้ว

      @@cafepuya How do you reduce the starting current of a refrigerator?
      a) use a start capacitor, 150uF, for the first 1000ms. b) use an NTC thermistor. c) power resistors, for the first 1000ms (similar effect as NTC) d) voltage transformation to a lower voltage, e.g. from 230V to 200V.

  • @jessemurray1757
    @jessemurray1757 11 วันที่ผ่านมา

    great tip, now if I only knew how to make something similar to this for my 220 volt well pump.

  • @dennisjohnson5271
    @dennisjohnson5271 4 ปีที่แล้ว +6

    You can find these current limiters in the variable speed, dc, hvac blower motors used in most late model ac systems. I stock them on my service truck because they fail very often. Most techs replace the motors for around $800-1000 I take them apart and replace the limiter for about $200. This is the most common failure of the hvac motors.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +3

      Many people allow their air filters to get very dirty, and the reduced airflow causes the winding of the blow motor to run hotter. Thanks for watching!

  • @billg4630
    @billg4630 3 ปีที่แล้ว +2

    I knew the minute I seen project Farm comment that this was a good video after watching it I can confirm it's an awesome video thanks a lot appreciate it

  • @lazar2175
    @lazar2175 4 ปีที่แล้ว +6

    Very elegant solution.
    But i think most people trying to run big inductive loads off inverters are trying to do emergency repair, so i thought i'd give you a few ideas on how you could limit the inrush current with stuff you can find around your house.
    So if you are a regular guy you probably don't have NTC's just laying around, especially in a emergency situation when power is out.
    What you probably own or could easily get your hands on is a graphite pencil.
    Shave off the ends and connect the wires to it, then wire a lightswitch in parallel to it.
    It is a single use and incredibly dangerous but when that little risk is the difference between life and death, i'm pretty sure you won't care.
    I used this method to start a really big drill when we had floods in 2014. I used that drill to bust a hole in a floor and stop water into coming into first floor flats and creating damage.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +2

      Not really about what you'd do in an emergency situation. It's about having the device on hand now, so in the event you need to power an appliance/power tool using a small generator or power inverter, you'll have a good chance of doing it. Before the pencil trick, I'd pull the oil filled run caps out of my A/C system to get the inrush reduced. Thanks for watching!

    • @charlesrichards5389
      @charlesrichards5389 3 ปีที่แล้ว +2

      MacGyver would be proud!

  • @impressusa
    @impressusa 2 ปีที่แล้ว

    I've read through as many of the comments as I could and did not find this subject addressed; apologies if its buried further down the line. I would like to use this directly in my shop on 120V house current where my table saw sometimes trips the 15A breaker. This has been the case ever since I bought the table saw a few years ago and it's something I just deal with. If this could alleviate the inrush current that trips the breaker then, AWESOME!! Really enjoyed the video. Clear, concise and your voice is very professional.

  • @GregHassler
    @GregHassler 3 ปีที่แล้ว +1

    Cool, simple solution. I just ordered parts to build something similar. I'm just going to put a receptacle on the end directly in the box.

  • @fortwoods
    @fortwoods 3 ปีที่แล้ว +4

    Wow this is amazing and thanks for including the link to the data sheet. There are 15 and 20 amp ones as well. Awesome.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Glad you enjoyed the video! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @stevef8993
    @stevef8993 4 ปีที่แล้ว +2

    Just used those on a project at work. The common name for the device is a thermistor. Nice video.

  • @budpark7790
    @budpark7790 2 ปีที่แล้ว +3

    I added a normally-closed, momentary-action shorting switch across the NTC on my table saw. I labeled the new switch "soft start" and "run" and mounted it next next to the on-off switch. When starting on utility power where soft-start isn't needed, I simply turn on the power switch and the NTC isn't in the circuit, being shorted by "start" switch. When starting on battery/inverter power, I first activate the "start" switch, putting the NTC in the circuit before turning on the power switch. As soon as the saw comes up to speed I release the "start" switch back to "run", again shorting the NTC. This allows the NTC to begin cooling while the motor is running and provides for more frequent starts. I wonder if it might also increase the life of the NTC by significantly reducing the time it is in use?

    • @stratocasterblue
      @stratocasterblue 2 ปีที่แล้ว

      Is this the reason for shorting one of the thyristors in his circuit, he never says why he put the switch in, it must be like you explain it to allow for cooling to provide more frequent starts, because why not just leave them in series without a switch to give you 10 ohm resistance a 50 volt drop every time you start it, strange he never explains that.

  • @idicalidical5343
    @idicalidical5343 4 ปีที่แล้ว +2

    Good work, I looked for a super cheapie inverter with built-in limiter without success, and settled on a capacitor setup which has been inconsistent as success depended on the particular load. So I'll give this a go.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      If you get the right ICL value, it works great. Thanks for watching!

  • @KG-wh8yv
    @KG-wh8yv 2 ปีที่แล้ว +2

    Well done and great explanation !
    This will work for my 2000W BESTEK Inverter tripping running a 200 watt Fridge when the power is out.
    Btw, your explanation at the end about why shouldn't wire them in parallel exactly explains what happened to the person on an RV website that said his setup exploded when he plugged it in.

  • @CraigHesling
    @CraigHesling ปีที่แล้ว +4

    Great tip! Have you considered adding another switch position to bypass both in-rush limiters, once startup is complete?

    • @lenturnbow8038
      @lenturnbow8038 ปีที่แล้ว +1

      Already done. Each thermistor drops to about 60 milliohms shortly after power is applied. For a 6 A load, the voltage drop for each is about 360 mV.

  • @jregamey
    @jregamey 2 ปีที่แล้ว +1

    I had my inverter replaced. It ended up being a smaller unit but it has soft start. So great. It could do better then my 4000 watt inverter

  • @button-puncher
    @button-puncher ปีที่แล้ว

    Great video! Thanks for the idea.
    Personally, I'm going to use a metal box and using a barrier strip for the connections. Putting these in a plastic box is just asking for trouble.

  • @anthonyalleyne8724
    @anthonyalleyne8724 ปีที่แล้ว +1

    Great video! Instead I used one sl32 10015 and it worked perfectly!! Thanks.

    • @electronicsNmore
      @electronicsNmore  ปีที่แล้ว +1

      Glad it helped Anthony! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others. Thanks
      th-cam.com/users/electronicsnmoreplaylists

    • @davidyummus6259
      @davidyummus6259 11 หลายเดือนก่อน

      So, a 1 OHM 20amp Thermistor would work fine ?

  • @david.vieiraocurioso4917
    @david.vieiraocurioso4917 2 หลายเดือนก่อน +1

    Its Very helpfull. Thanks you!

  • @vevenaneathna
    @vevenaneathna 3 หลายเดือนก่อน

    you can also use a solid state relay coz the optocoupler has to start at the 0 cross point of the sine wave. not sure what would cause more parasitic resistance when running.

  • @davidbivens2246
    @davidbivens2246 2 ปีที่แล้ว +1

    I NEED HELP…. I have an air conditioner 5.9 amps running. 115v @ 60 hz. My inverter is 1000 watts. The inverter is overloaded 9 out of ten times I turn the a/c on with it. Which thermistor do I need?

  • @pulesjet
    @pulesjet 4 ปีที่แล้ว +3

    Good Stuff from you Sir. Easy and Practical. Think I will build one into a small pig tail extension cord.

  • @NETBotic
    @NETBotic 4 ปีที่แล้ว +10

    I always take an angle grinder camping, thanks!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +4

      There are other things that have high inrush, that was just a good example. :-)

    • @NETBotic
      @NETBotic 4 ปีที่แล้ว

      @@electronicsNmore excellent example

    • @Lumbeelegend
      @Lumbeelegend 3 ปีที่แล้ว

      I'm off grid, and was looking for a solution to stop my window unit AC, (~1300w) from tripping my 5Kw inverter/charge controller. The in-rush is making it impossible to run it, even though I run my water heater on it (resistive vs inductive, as you stated). Hopefully this will work. I may build a few of these, lol. Thank you so much.

    • @johnq8792
      @johnq8792 3 ปีที่แล้ว

      RV uses fridge or AC which the inverter can't handle, and the commercial unit for this problem is $300.- this $1 fix is a way out, and thank you for this.

    • @Vigo327
      @Vigo327 3 ปีที่แล้ว

      @@Lumbeelegend Did you try yet? Very curious..

  • @raphola1
    @raphola1 2 ปีที่แล้ว +1

    This is good education. Thank you.

  • @jimm2442
    @jimm2442 2 ปีที่แล้ว +1

    Fantastic! So glad I found you. Thank you!

  • @dwash595
    @dwash595 8 หลายเดือนก่อน

    Great video. I have a project for it already! Three actually. Thanks!!!

  • @timothydelossantos3622
    @timothydelossantos3622 3 ปีที่แล้ว +2

    Can i use this with an air-conditioning non inverter, will this soft start the compressor every time it kicks on?

  • @flash001USA
    @flash001USA 4 ปีที่แล้ว +7

    Couple of McQuestions: Once the threshold temperature is reached and the resistance drops does it hold that resistance as long as the load is still powered up? In other words does it stay latched in it's low resistance state once it's activated even when the current demand drops once the inductive load has started? I ask this because once the resistance is triggered low then the voltage drop across the Inrush Limiter will fall too so it would naturally cool down.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +2

      Yes. As long as the load is applied, the low level of resistance will remain. The ICL will be fairly hot, but it's normal. You cannot rapidly cycle loads on and off using the ICL. You must wait 30 secs to 1 minute. Thanks for watching!

    • @pepeshopping
      @pepeshopping 4 ปีที่แล้ว

      flash001USA
      Google has the answer.

    • @andrewferg8737
      @andrewferg8737 4 ปีที่แล้ว +4

      You can add a temperature sensing circuit to bypass the inrush limiter once it heats up.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +1

      @Andrew Ferg Not necessary because the resistance drops to a very low level. Thanks for watching!

    • @charlesrichards5389
      @charlesrichards5389 3 ปีที่แล้ว

      @@andrewferg8737 Not a bad idea. Inrush limiters do wear out. In fact, they are often the only part that wears out on pool chlorinator control boards.

  • @rogergregory5981
    @rogergregory5981 4 ปีที่แล้ว +1

    Nice and very useful , In the uk If you have trouble with 110 volt site transformers tripping circuit breaker's when you plug the in /switch then you can get round this by plugging in your power tool to the trans former first then switch on power tool , then switch on the transformer this can limit inrush to the transformer and prevent the circuit breaker tripping

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Interesting workaround! Thanks for watching

  • @alexvonbosse5090
    @alexvonbosse5090 4 ปีที่แล้ว +3

    Very good information! Thanks for sharing!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Thanks, and you're welcome! Helpful videos like this are only worthwhile to make if viewers take one minute of their time to share the video link with others.

  • @jamesallen6007
    @jamesallen6007 3 ปีที่แล้ว +1

    Simply put. Many thanks.🇬🇧😷

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Glad you enjoyed it James! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @riloariichoariicho884
    @riloariichoariicho884 4 ปีที่แล้ว +3

    I like this idea.it's so helpful to me

  • @liquidrockaquatics3900
    @liquidrockaquatics3900 3 ปีที่แล้ว +2

    Interesting. Would you couple this with a capacitor for greater effect?

  • @Ewolk89
    @Ewolk89 4 ปีที่แล้ว +1

    Loved the video! Thank you! So what you really have to do is break the Hot line and add the components, switch and box. The other lines can stay intact.

  • @oldmgbs2
    @oldmgbs2 4 ปีที่แล้ว +2

    Very handy device, thanks.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      You're welcome Steve! Be sure to share. Thank you

  • @anonymous.369
    @anonymous.369 2 หลายเดือนก่อน

    Great video, thank you. Can you do one for 50 amp 240v 4 wire split phase grnerator/inverter. Thx.

  • @benkanobe7500
    @benkanobe7500 2 ปีที่แล้ว

    Amazing! Thank You, Thank You, Thank You! I am going to make one this weekend. I think using a metal box would dissipate heat better (or would it?).

  • @pfoxhound
    @pfoxhound ปีที่แล้ว +1

    Very nice 👍🏿, can you please make one for air conditioner compressor, because if air conditioner doesn't start and continue to work immediately, than the elements will get hot fast and there will be no soft start for the compressor.

  • @marksr49341
    @marksr49341 ปีที่แล้ว +1

    Great, thank you.

  • @teku3985
    @teku3985 3 ปีที่แล้ว +2

    This is a useful video for a quick and cheap soft starter for preventing inrush currents in devices. However, you should design an updated version of the circuit. While this design works, and works well, there is one fatal flaw. If you unplug the load and plug it back in or switch the load on and off it draws the same inrush current we are trying to prevent.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +4

      This method isn't recommended for rapid switching ON/OFF of appliances/devices.

  • @jp040759
    @jp040759 4 ปีที่แล้ว +2

    Good simple solution!!!!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Yes. It's very handy to have around in the event you have an inrush problem. Thanks for watching!

  • @freeradical431
    @freeradical431 2 ปีที่แล้ว

    Where were you ten years ago when I went off grid? lol I just got a new water pump 12 amps that wont start off my Cotek sk1500. If this will work on a capacitor start motor its gonna be a big help!

  • @skipwilson5086
    @skipwilson5086 ปีที่แล้ว +1

    I just found this video this morning, already watched it two or three times and copied the adderess so I could share it with my buddy down in Louisiana, any way I'm wondering if you could do one or at least answer the question about a single phase 10 Hp motor that keeps throwing my inverter into safe mode. I've got an 18K inverter that drives the motor, but it still needs a soft start, Any help would be sincerely appreciated.

  • @ScinnerNo1
    @ScinnerNo1 4 ปีที่แล้ว +2

    Thx for the video. I have a question.
    Let's say I wanted to power my refridgerator with your inverter, how much power will those two buggers dissipate in heat? And also could you bypass them when the fridge have started or are they needed every time the compressor starts?

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      You need to choose the correct size ICL for the load. They can be bypassed if desired after start-up. Thanks for watching!
      www.ametherm.com/inrush-current/selecting-an-inrush-current-limiter.html

  • @jws3925
    @jws3925 8 หลายเดือนก่อน

    Nice idea! I am going to try this.
    Question: What is the difference between these in rush limiters and a resistor, in this case like a 5 ohm, 100watt resister?
    I am using a resistor in series for a few seconds between a battery bank and an inverter prior to hooking up the last cable to the inverter to prevent the spark I would incur due to the in rush current which is caused by the charging up of the internal capacitors of the inverter.
    I know one is a DC circuit and one an AC circuit so that is one difference. I don't know if this the reason for these in rush current limiters vs just a resistor. Do they both work the same?
    What does the 15% designation mean in the specifications of the limiter? I see there are other limiters with different specs such as one rated for 20 amps, 1 ohm resistance and 20%?
    I want to start an electric motor that after startup will draw 6 amps but, as you know, it draws about 3x that on startup. Will your idea work for me and, if so, what size in rush limiter should I be looking at. Thanks so much.

  • @donniehill1383
    @donniehill1383 หลายเดือนก่อน

    Was wondering if this is a safe solution for a mini split AC that dims the lights when the compressor kicks on? What would it hurt to leave the switch on all the time or just delete the switch on the box altogether? Would be sure to drill the vent holes in the box

  • @techs5564
    @techs5564 4 ปีที่แล้ว +2

    great trick.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Thanks for watching! Please share the video.

  • @abidchaudhary3439
    @abidchaudhary3439 6 หลายเดือนก่อน +1

    Thank you so much❤

    • @electronicsNmore
      @electronicsNmore  6 หลายเดือนก่อน

      You're welcome! Be sure to check out my extensive video playlists for many other videos of interest to you and share. Thanks

  • @glasser2819
    @glasser2819 2 ปีที่แล้ว +1

    smart man... and cheap too 👍

  • @raybrown9655
    @raybrown9655 2 หลายเดือนก่อน +1

    can you make a soft start to be used on RV a/c (DOMETIC) on 5th wheel in order to use a small 2000 gen to run a/c

    • @Steve-xl2mn
      @Steve-xl2mn 14 วันที่ผ่านมา

      Check Amazon. Running a cheap no-name here, and it's been fantastic.

  • @Olavotemrazaodenovo
    @Olavotemrazaodenovo 4 ปีที่แล้ว +1

    Excellent idea.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you liked it! Be sure to share the video link. Thank you

  • @HR-rt9nh
    @HR-rt9nh 5 หลายเดือนก่อน

    can you attach a heat sink directly to it? or does it need to get hot to work and a heat sink would prevent it from working correctly

  • @stanwinston7199
    @stanwinston7199 2 ปีที่แล้ว +1

    Would I put the thermistors on both L1 and L2 for a 240V submersible 1.5HP 4" pump? Normal amperage on both legs is 11.5 A, so am thinking that I'd be able to mimic exactly what you have, but put 2 on each leg. Is that correct?

  • @davidyummus6259
    @davidyummus6259 11 หลายเดือนก่อน

    So the Limiters are 12 amps each,... Does that mean if you only need to start a smaller appliance of under 12 amps, you would just switch your box to "Low" to use just one ?... Could you not use a switch to have it wired to use both Limiters all the time ?
    Thanks for the video.

  • @Allenw154
    @Allenw154 2 ปีที่แล้ว

    If you’re near a Home Depot, you can setup an excellent box cheap. Get a 2 gang square metal box, a toggle switch, a duplex outlet, and a square box cover with toggle/duplex holes. Sleek and secure!

  • @ThePreyMantas
    @ThePreyMantas 4 ปีที่แล้ว +1

    Very useful. Another great tip eNm! Keep'em coming!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว +1

      As long as people share, they'll keep coming. 😀 Thanks for watching!

    • @ThePreyMantas
      @ThePreyMantas 4 ปีที่แล้ว

      @@electronicsNmore What do you think about these Graphene Module Packs?

  • @AlanCanon2222
    @AlanCanon2222 2 ปีที่แล้ว +1

    A thought on using this circuit to power a room air conditioner (I'm thinking 450 W, 115 VAC, 5000 BTU). Considering also what others here have suggested (power factor capacitor, and a timed relay), etc. My thought is that the air conditioner has two motors in it, the fan and the compressor. So should I actually open up the air conditioner and install two separate instances of this DIY soft starter, one on the fan motor, and one on the compressor motor, both with independent inrush limiters, capacitors, and relays? That way the fan and compressor loads are each separately buffered. What I'm worried about is that the fan will run continuously (keeping the inrush current limiter hot and therefore out of action), the compressor will turn off, then on again, and the inrush current limiter will not be active. Having two separate soft starters would seem to solve that problem.

  • @markrigneymd6570
    @markrigneymd6570 4 ปีที่แล้ว +1

    I am a firm believer in Occam's razor!

  • @remingtontreich9986
    @remingtontreich9986 2 หลายเดือนก่อน

    Thank you very much. You just saved me from buying a new generator.

  • @rjl110919581
    @rjl110919581 4 ปีที่แล้ว +1

    thank you for detail video

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      You're welcome Rob! Please share the video link with others. Thank you

  • @ahmadmughal2893
    @ahmadmughal2893 3 ปีที่แล้ว +1

    Great information

  • @dig1035
    @dig1035 4 ปีที่แล้ว +2

    Very cool vid, thanks!

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you enjoyed it! Please share the link. Thank you

  • @justinmas299
    @justinmas299 7 หลายเดือนก่อน

    Cool thing, gonna make it and see

  • @graemeboese1405
    @graemeboese1405 3 ปีที่แล้ว

    Great video I have a inverter fridge should I mount this on the power to the compressor motor

  • @zackvizeman5329
    @zackvizeman5329 2 ปีที่แล้ว +2

    Great video much appreciated.
    Question: I am trying to lower the combat of a compressor with a rated LRA of 122 amp! The reason I need to do that is that its FLA is only 24 amp and I wonder if one could use a 30 AMP breaker instead of the specified 40 amp. Can I use your trick for that purpose?
    I greatly appreciate your response!

    • @button-puncher
      @button-puncher ปีที่แล้ว

      I was wondering the same thing. I'm guessing that Digikey or Mouser would have monster limiters that could handle the current.
      The only thing that I'd do is add a timer relay and a solenoid valve to the unloader line on the compressor. So that when you apply power it keeps the unloader pipe open for a few seconds until the compressor is up to speed. The close the solenoid to build pressure. You'd also want a relay to short the current limiter once the compressor is running. That way the current limiter won't burn up.

  • @y1hardtop
    @y1hardtop 4 ปีที่แล้ว +1

    Fantastic tip!!

  • @SolarEngineering
    @SolarEngineering 4 ปีที่แล้ว +1

    great video! thank you.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you liked it! Be sure to look over my extensive video playlists below for many other videos of interest to you, and share links to my videos with many others on social networking sites. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @MoritzvonSchweinitz
    @MoritzvonSchweinitz ปีที่แล้ว

    I would like to use an inrush limiter like this for my hydropneumatic pump that has a cycle time of aprox. 20 seconds. How quickly do these NTC thermistors warm up and cool down? Something tells me that this elegant solution wouldn't work for a load that cycles 20 seconds on and 20 seconds off?

  • @markrigneymd6570
    @markrigneymd6570 4 ปีที่แล้ว

    I just saw your previous response to the same 220V question and I think my thinking was correct (just l got lucky with a tiny bit of self education) but I choose not to go with an "I think" when dealing with A/C. Still interested in you thoughts on the other more complex methods?

  • @emanwols8219
    @emanwols8219 3 ปีที่แล้ว

    Thanks for video. exactly what i was looking for. really good info.
    i am having trouble selecting which NTC is appropriate for a 300watt inverter which will be powering a 200watt PTC ceramic steamer only. I am thinking i need an NTC that can handle 20 amps .
    thanks

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      If the inverter is only 300w, then 20A is overkill.

  • @danic9523
    @danic9523 ปีที่แล้ว

    If I build one for use with a small Residential refrigerator (with compressor) that will run 24/7off an inverter--will I need to add a capacitor somewhere? If yes, where would I place it if it had to be soldered. Also, is the same build applicable to a 30A unit if I buy 2 X 10 Ohm resistors?

  • @robindas1207
    @robindas1207 4 ปีที่แล้ว +1

    sweet! nice demo

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you enjoyed it! Be sure to check out my wide range of videos for many other videos of interest to you, and most importantly share my video links with many others. Thanks Robin!
      th-cam.com/users/electronicsnmorec/playlists

  • @sahilsharmadec25
    @sahilsharmadec25 4 ปีที่แล้ว +1

    easy and logicable

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you enjoyed the video! Be sure to look over my extensive video playlists below for many other videos of interest to you, use supplied Amazon links to support my channel when making purchases(No added cost to you), and share links to my videos with many others on social networking sites. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @JasonCarmichael
    @JasonCarmichael 3 ปีที่แล้ว +2

    Sure beats the heck out of paying $140 for someone else's soft starter!
    Thanks!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +2

      There are cheaper soft starters sold, but this is as cheap as you'll get. :-) Be sure to look over my video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites. Thanks
      th-cam.com/users/electronicsnmoreplaylists

    • @OgBooder302
      @OgBooder302 3 ปีที่แล้ว

      Where can i find them?

    • @JasonCarmichael
      @JasonCarmichael 3 ปีที่แล้ว +1

      @@OgBooder302 links are in the discription

  • @Skipperj
    @Skipperj 3 ปีที่แล้ว +1

    Thanks great stuff! Now,do you have a box for a 240v soft start, for a 4 ton ac?

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      I would try using a hard start kit for your AC condensing unit.

  • @whitefreeman5798
    @whitefreeman5798 ปีที่แล้ว

    does this do the same thing as the soft start products sold for air conditioners that are 300 or more dollars

  • @bolmarie
    @bolmarie 4 ปีที่แล้ว

    Amazing solution. Thanks. Questions 1) Why did you install that switch? Why not always have the two SG333 in the circuit? 2) Will this harm non-inductive loads such as computer devices, TV, or cell phones powered by the inverter thru that soft starter end female plug?

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      The switch allows me to choose between two levels of starting resistance. No reason to use what's shown for non-inductive loads. Thanks for watching

    • @stratocasterblue
      @stratocasterblue 2 ปีที่แล้ว +1

      @@electronicsNmore Why do you want two levels of starting resistance though, Why not just always use both in series to make 10 ohms and always have the lowest the inrush current making it easier on the inverter and the motor.

  • @MiamiWebDesign
    @MiamiWebDesign 3 ปีที่แล้ว +2

    Awesome work. Commercially available softstarters for window AC units cost around $300. Can this be used to turn on a small fridge or window AC with a generator or inverter? Thanks for this video!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +3

      If you size the inrush limiter properly, it can help you start up the fridge/AC. If you don't size it correctly, then the compressor may not start up.

    • @MiamiWebDesign
      @MiamiWebDesign 3 ปีที่แล้ว

      Thanks alot

    • @energydreamer5347
      @energydreamer5347 ปีที่แล้ว

      @@electronicsNmore - is there a size limit to build this device? Is there a cutoff on scaling it up? Searching for a Soft Starter for 10HP AC Motor. Any feedback?

  • @putumadhava3519
    @putumadhava3519 4 ปีที่แล้ว +2

    Very informative video, this is the kind of video I was looking for a while, but I do have some questions, does this system works with induction motors ?, and if the resistance is very low after the resistor heats up, does it mean if the load is powered up in short interval and the resistor resistance value is still low it can experience inrush current again ?

    • @Vigo327
      @Vigo327 3 ปีที่แล้ว +1

      Good question. I am interested in this for reducing the inrush current to a small ac compressor but once the ac is 'running' it will cycle the compressor as needed. It would depend on if the thermistors can cool all the way off before the next compressor start. It also seems possible that you run into an issue of your normal 'running' current not creating enough heat in the thermistor to maintain its lowest resistance value consistently, causing the current in the actual load device to fluctuate as the thermistor 'hunts'. Really interested to know how this works on a ~5000btu ac.

    • @AlanCanon2222
      @AlanCanon2222 2 ปีที่แล้ว +1

      @@Vigo327 Did you ever try it? I'm wanting the exact same application, 5000 BTU A/C that is rated 450W @ 115 VAC.

    • @Vigo327
      @Vigo327 2 ปีที่แล้ว

      @@AlanCanon2222 I have not! I have tabs open in my phone about calculating the value of the thermistor, etc, but never did do it. I have been working on an off-grid electrical system for my home and can say that my 5000btu unit in the home actually is down around 400w with the compressor running and fan on high. The fan itself is 60w on high, so compressor load on my unit is ~340w. I have not accurately captured the compressor 'inrush current' yet, though. Good luck with your project and i hope whoever tries it first will post their result. 👍

  • @AlCapwndYou
    @AlCapwndYou 3 ปีที่แล้ว +2

    Quick question; I am thinking about doing this for a dust collector (basically a giant vacuum). It pulls 35-50A on the inrush, and settles down to around 8-10A at running load. Would something like this work to reduce that massive inrush current to prevent overloading a circuit breaker? Also, when you mention sizing the inrush limiter, is that for the inrush load or the running load?

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +5

      If you use the correct resistance value and current rating, yes. The size is matched to the operating current.

    • @AlCapwndYou
      @AlCapwndYou 3 ปีที่แล้ว +1

      @@electronicsNmore Thank you very much - appreciate the response! Subscribed!

  • @jamesstethers8173
    @jamesstethers8173 10 วันที่ผ่านมา

    Probably won’t ever see this comment but I made one using 2 15 amp rated current limiters around 5 ohms each, got it all put together plugged it in nothing happened, plugged in a small shopvac to try and get my little generator to run it and one of the limiters started smoking, shouldn’t they be able to handled that load being rated at 15amps?

  • @syedzada411
    @syedzada411 2 ปีที่แล้ว

    Great video, I have 2000 watt Honda generator with max output of 13 amp.
    when I try to power my 8k btu ac on its trip.
    Will your device work for it.

  • @ambitious44
    @ambitious44 3 ปีที่แล้ว

    hi , thanks for the great explanation. still one point : if we power Off and quickly try to power on the appliance, a good chance the thermal resistor still hot and thus didn't present high resistance so It will not work. I ve not tested it myself but I am curious if someone have experienced that exact very scenario I am describing here

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      You cannot power on and off quickly. You need to wait at least 30 seconds.

  • @jasonlucero1523
    @jasonlucero1523 2 ปีที่แล้ว +1

    Hello. Great video! I would like to build a similar soft start for a miter saw. I would like to build it for 25 amps. Would this work? Ametherm SL32 1R030 (Pack of 2) NTC Thermistor, SG379 HVAC, Inrush Current Limiter 1 Ohm Ohm ±20% 1.18" (30mm), or what do you recommend? Thank you sooooo much!

  • @Edmorbus
    @Edmorbus 4 ปีที่แล้ว +1

    Thanks for sharing

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Thanks for watching Ed! No idea why, but your comments always end up in spam. I need to approve them. Weird.

  • @jrm4408
    @jrm4408 11 หลายเดือนก่อน

    I would like to make one of these for an off grid cabin I have. It has a fairly new Best Buy/Insigina 9.9 cu ft fridge/freezer that lists power consumption of 160W at 1.4A. I have a 12v 2000W inverter connected to 2 banks of GC2 6V batteries in series, so 2 pairs of 6V's on a battery switch so I can switch from bank 1, 2, or tie both together. You'd think that would be enough to start the fridge under any circumstances, but it doesn't. When one bank gets on the low side but still far from the end of its cycle, the fridge starting up will trip the low power alarm on the inverter and it won't reset itself (all power cables are correctly sized, probably overly large). If I flip the battery switch briefly to the other bank then back again, the inverter will be happy, quit beeping and the fridge will run until it shuts off, and the cycle repeats. Question is - do you think the setup in your video would be sufficient for this fridge, or should I be re-sizing the components and if so how do I know what size?

    • @jrm4408
      @jrm4408 9 หลายเดือนก่อน

      I built this and tried it out but it didn't seem to solve the problem and the inverter still trips to under voltage. The fridge (1.4 running amps) is the only thing I'm using this for. Should I be using smaller inrush current limiter like a 5D-11 rated for 4A continuous?

  • @edwinsabado2385
    @edwinsabado2385 ปีที่แล้ว

    how about 220 v. what is the value to use sg333?

  • @DIYwithBatteries
    @DIYwithBatteries 4 ปีที่แล้ว +1

    That looks pretty cool🤓 sir.

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Thanks for watching! Be sure to share the link.

    • @DIYwithBatteries
      @DIYwithBatteries 4 ปีที่แล้ว

      @@electronicsNmore yes i do sir 😊

  • @curtchase3730
    @curtchase3730 3 ปีที่แล้ว +1

    Nice tutorial. You failed to mention the drawback of this method.....Repeated use. If you use a power tool for instance, you may have tool on and off many times during a job, like cutting 2x4's. The thermistor would have to cool really fast between starts or it will be supplied with full inrush current again, right?

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Correct, this method isn't ideal for fast ON/OFF switching. You need 30 seconds minimum wait time

    • @SalC1
      @SalC1 2 ปีที่แล้ว

      @@electronicsNmore I have a portable log splitter that I want to run with this. I ordered the inrush current limiter and I plan to thermal epoxy it to the inside of an aluminum junction box to remedy this issue. Hopefully it works!

  • @thomasdoherty6876
    @thomasdoherty6876 3 ปีที่แล้ว

    Great video! Very informative and a simple solution to many problems. I have been thinking about rigging up a couple of flexvolt batteries to power 110v 1/2 router but was worried about the inrush current damaging the batteries with arcing during switching on and off, would this not only soft start but soft stop? If thats a thing?

  • @richiem9316
    @richiem9316 2 ปีที่แล้ว

    Hey thanks for the vid. Do you mind linking a oil filled run capacitor to test? I have a 2000w inverter and on occasion it will alarm when starting a 15a mitre saw or tablesaw. Amazon likes to write both start and run on the capacitors.

  • @aircondititioning
    @aircondititioning ปีที่แล้ว

    Great video! I would like to make one of these to help power on a window AC unit with a 12v inverter. Forgive my ignorance but is is necessary to use a switch to use the two limiters? Would it be a bad thing or would certain items not work if you were to always leave the two limiters connected at all times? Thank you!

    • @davidyummus6259
      @davidyummus6259 11 หลายเดือนก่อน

      I was wondering the same & wish you got an answer.

  • @russeljamesalamer2332
    @russeljamesalamer2332 3 ปีที่แล้ว

    Thank you for this video. I have however a 5.8 full load ampere pump, and 220v hot wire. Will the same limiter suits my equipment? Appreciate your advice.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      There's a link in the video description area to a calculator.

  • @trench01
    @trench01 4 ปีที่แล้ว +2

    fantastic. I am sure more will see this video. ;) does this have a technical name?

    • @electronicsNmore
      @electronicsNmore  4 ปีที่แล้ว

      Glad you liked it. More will only see it, if my viewers take the time to share the links. No technical name that I'm aware of. Thanks for watching!

  • @awaywedrove8861
    @awaywedrove8861 3 ปีที่แล้ว +1

    Am I right to imagine that there's a good deal of efficiency loss due to heat? I recently got a soft start RV which is designed to start AC compressors specifically, and it doesn't have any visible heat sinks or anything like that. I imagine it's a more efficient setup, but obviously much more expensive. Kinda curious if what you have here would work for some smaller inductive loads i have in the RV

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      What you bought must use a capacitor. A soft start kit. As for the ICL, you will always have some power loss with it connected.

    • @awaywedrove8861
      @awaywedrove8861 3 ปีที่แล้ว

      @@electronicsNmore that makes sense, thanks!