Recharging a dehumidifier with Freon Part 3

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ต.ค. 2024

ความคิดเห็น • 168

  • @BENZ007
    @BENZ007 2 ปีที่แล้ว +2

    Thanks for these 2 videos, this one looked very similar to mine and now it works great. Was just low on refrigerant. I got the piercing valve from Walmart.

    • @supjay3945
      @supjay3945 8 หลายเดือนก่อน

      Whats the kit called? Thx

    • @BENZ007
      @BENZ007 8 หลายเดือนก่อน +1

      @@supjay3945 before you try it, mine lasted about 4 weeks and died again, likely leaked out. So I bought a new dehumidifier. It's just an a/c tap line. Ordered it from Walmart. Was not worth the effort for me. Good luck

  • @Horse-c2t
    @Horse-c2t ปีที่แล้ว +8

    All the time this takes and supplies needed (the cost exceeds a replacement) you convinced me throw out my broken one. Thanks! BTW, you can go faster with those bursts. Not necessarily to go that slow.

    • @michaelprosperity3420
      @michaelprosperity3420 ปีที่แล้ว +2

      You can buy the refrigerant for about $89 bucks and the piercing valve for about $10. The refrigerant he has that comes with the gauge is about $190. The $89 refrigerant doesn't have a gauge. My take on this is if I'm going to spend $190 for the refrigerant I'll get a leak detector, piercing valve, a really good gauge set on Amazon and then get the $89 can and I'll have the equipment to service other things around my house. My refrigerant is the R410-a

    • @nudracodad738
      @nudracodad738 ปีที่แล้ว

      @@michaelprosperity3420 I strongly believe that R410-a is could be easily replaced by R-134A

    • @joshledford8921
      @joshledford8921 4 หลายเดือนก่อน

      My dehumidifier cost over $500.00 This is well worth it in my opinion.

    • @nickdangelo2591
      @nickdangelo2591 4 หลายเดือนก่อน

      @@nudracodad738 can i really use 134a in a 410a system ?

  • @inoahguy1578
    @inoahguy1578 6 ปีที่แล้ว +10

    Freon is Dupont's name for r12 and r22. So I was a little confused when I was your video. But great instructional video keep up the good work. Btw if you dont like calling refrigerants by their number r410a can be called Puron.

    • @reganlebaron7103
      @reganlebaron7103 6 ปีที่แล้ว +1

      Good to know, thanks for Watching

    • @egSmith-sp9gl
      @egSmith-sp9gl 5 ปีที่แล้ว

      R12 is not in use anymore
      the most common now is r134a or Tetrafluoroethane

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว

      @@egSmith-sp9gl R134a is used in automotive applications, R410a is used in most residential AC units.

    • @craigerickson1910
      @craigerickson1910 3 ปีที่แล้ว +1

      @@paulmoffat9306 This is outdated. R134a was used in cars starting in 1994 until recently. Many cars now use R1234yf as R134a is being phased out. Older residential A/C used R22 no longer being made. R410a is common now.

  • @dili00007
    @dili00007 2 หลายเดือนก่อน +4

    Where can I find the piercing valve and r410a can with hose and gauge?

  • @SpartanBrass
    @SpartanBrass 4 ปีที่แล้ว +5

    I’ll be damned it worked! Finding a hose for r410 wasn’t that easy but I’m ready to open up my own dehumidifier service business

    • @chrisglass7654
      @chrisglass7654 4 ปีที่แล้ว

      Jim ... what Bullet Valve did you use? Can you tell me the one you purchased?. They all seem to indicate they are not for use with R410A. I purchased a BPV31 but when I read the instructions it says not to use with R410A. Thank you.

    • @electricboyo
      @electricboyo 3 ปีที่แล้ว

      @@chrisglass7654 I wondered about this also. So I researched it and confirmed that bullet piercing valves are safe to use with R-410A when installed on the low side (suction line) only. This is the line from the evaporator to the compressor. It is usually covered with mastic or foam insulation. This is the line which gets cold when the unit is running. Note that R-410A has much higher operating pressures than R-22 or R-134A. Therefore it is wise to avoid making any connections to the high side, which may have several hundred PSI while the compressor is running.

  • @MrRene1968
    @MrRene1968 3 ปีที่แล้ว +5

    great info. I am curious. The refrigerant escaped, was the leak fixed before refilling?

    • @Horse-c2t
      @Horse-c2t ปีที่แล้ว

      Details 😂 with all the cost to get the stuff to repair it, cheaper to just buy a new one.

  • @jeffreynavallo6684
    @jeffreynavallo6684 2 ปีที่แล้ว +3

    Did the compressor get real hot to the touch when you recharged?

  • @publicEnima
    @publicEnima 3 ปีที่แล้ว +4

    did you have to recharge it since the video?

  • @BENZ007
    @BENZ007 2 ปีที่แล้ว

    great videos

  • @CUSTOMWORKS7.3PSD
    @CUSTOMWORKS7.3PSD 2 ปีที่แล้ว

    THANKS HEY Just got done doing a 1 year old fridgidaire 90 was a little scary the pressure gauge jumped from zero to 20 after alot of filling so patients folks let it cycle

  • @saulvilleda9954
    @saulvilleda9954 19 วันที่ผ่านมา

    My compressor is very hot.
    I have to replace the compressor? The freedom valve is in the top. Santa fe classic vertical unit

  • @celestialdream49
    @celestialdream49 ปีที่แล้ว +2

    Reganrepairs, thank you for the videos - nice job. I have a question: My dehumidifier is freezing up and I'm assuming the problem is it needs a charge. If my system is freezing up because it's low on coolant, doesn't that mean somewhere on my system there's a leak? If you don't find and repair the leak, isn't it just going to need (and keep needing) to be charged up with additional coolant?

    • @ranger178
      @ranger178 หลายเดือนก่อน

      yes they make all the parts out of crazy thin tubing and there is probably a pin hole someplace you could try soapy water and solder hole, but you will probably need to keep adding some freon over time

  • @jeffwen6120
    @jeffwen6120 2 ปีที่แล้ว +1

    Hi,Thank you for your nice video,it is helpful!May I know what is the band for the R410A Refrigerant,and where can I buy it?could you please leave a link for R410A Refrigerant?

  • @tommycfchen
    @tommycfchen 3 ปีที่แล้ว

    You inspire me and I am going to get my dehum back in service......

  • @MrAntosh73
    @MrAntosh73 ปีที่แล้ว

    Hi, which way the fan blows?

  • @mnew213
    @mnew213 5 ปีที่แล้ว +26

    where to buy the Freon and the Gauge? Thanks

  • @rondail5675
    @rondail5675 หลายเดือนก่อน

    I was just going to install piercing valve on my dehumidifier which uses R410. The Supco Piercing valve instructions state it is not for R410 use. Any thoughts??? Please!

  • @John-dp3ln
    @John-dp3ln ปีที่แล้ว +1

    Small appliances, proper way to do this is to evacuate the system and per the nameplate, weigh in exact amount. The demonstrated method works also but there is no guessing with weigh in method.

  • @kevinstiles286
    @kevinstiles286 2 ปีที่แล้ว

    Thank You for the demonstration, My compressor runs but there no frosting occurring. I’m assuming there’s no refrigerator gas in the system or it’s too low. I don’t have a valve g

    • @kevinstiles286
      @kevinstiles286 2 ปีที่แล้ว

      Sorry to add the gas , any suggestions. This unit is only 1 year old . GE model uses the 410A gas

  • @MichaelChanslor
    @MichaelChanslor 5 ปีที่แล้ว +5

    Thanks for the video! Did the silver clamp on the compressor end come with the r410 kit? I'm looking at mine and I don't see any connectors for adding freon.

    • @waveriper20021
      @waveriper20021 5 ปีที่แล้ว +3

      Michael Chanslor its called a bullet piercing valve you can get on ebay or amazon

    • @kairamon8810
      @kairamon8810 3 ปีที่แล้ว

      You all probably dont give a damn but does anyone know of a trick to log back into an Instagram account..?
      I somehow lost my password. I would love any tricks you can offer me

    • @milomaxim9038
      @milomaxim9038 3 ปีที่แล้ว

      @Kai Ramon instablaster =)

    • @kairamon8810
      @kairamon8810 3 ปีที่แล้ว

      @Milo Maxim I really appreciate your reply. I got to the site through google and im trying it out now.
      Looks like it's gonna take a while so I will reply here later when my account password hopefully is recovered.

    • @kairamon8810
      @kairamon8810 3 ปีที่แล้ว

      @Milo Maxim It did the trick and I now got access to my account again. I'm so happy!
      Thanks so much, you really help me out :D

  • @runthenumbers9698
    @runthenumbers9698 ปีที่แล้ว

    Thanks for the video
    I'm a bit confused though. I don't understand why the ice spread when you gave it more freon... and then when you gave it even more, the ice receded.

    • @ranger178
      @ranger178 หลายเดือนก่อน

      the freon is released through a valve from warm high-pressure liquid into a cold low-pressure gas if there is too little freon it only goes a small distance into pipes of coil at very cold temp the more you add the further it travels but has some pressure in coil, so it is right around freezing rather than way down at 20 degrees like a can of duster for computers.

  • @mariuszdy5843
    @mariuszdy5843 ปีที่แล้ว

    awesome video, It's shame that R410A is being faze-out! Where did you get your gas from I'm struggling to find one here in Canada :(

  • @ranger178
    @ranger178 หลายเดือนก่อน

    actually, the compressor takes the cold low-pressure gas and compresses it into high pressure hot gas as it goes though the condenser coil it cools enough to be a warm liquid at high pressure then gets released through valve into the cooling evaporator coils and drops to a low-pressure gas making it ice cold.

  • @thomaslynn8441
    @thomaslynn8441 ปีที่แล้ว

    Hello, all I need is hose and gauge like your , where can you get them?

  • @421CentralIowa
    @421CentralIowa ปีที่แล้ว

    Thanks for the info. Man, a can of R410a like this costs 140 dollars? That's the same price as a new dehumidifier. Can you just empty the system and replace with R134a?

    • @ranger178
      @ranger178 หลายเดือนก่อน

      no they use incompatible oil and the refrigerant runs at different pressures

  • @Jolly-Way
    @Jolly-Way 4 ปีที่แล้ว

    Your straightforward demonstration on how to recharge a faltered dehumidifier encouraged me to try it also. I would appreciate if you could answer the following questions before I feel more confident to do try it myself. The dehumidifier in your demonstration looks (or is) the same as mine.
    What should the low/high pressure be in a normally working unit? - with motor running or not? The answer will help in estimating the loss of refrigerant after comparing the present pressure with normal pressure. Of course, the connecting valve (piercing valve) is always connected at the low side. Specs show that the pressure in a working unit is 290 - 580 PSIG. Is that range on the low side/suction side - when running? Presently the unit is not cooling down, i.e., not collecting water.
    Where would I be able to buy a recharge tank the size/type you are showing in the demonstration - and the cost?
    Your helpful reply would be appreciated.
    Best regards.

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว +3

      I purchased the same system just recently, and you can get it as a 'kit', which is the gas tank and a hose with a gauge. Always use the gauge that is intended for the gas being used, as the pressures do change (R22 is lower than R410a or R134). A 1.8 lb kit for R410a is about $135 US (Pro Charge brand) on eBay.

    • @Jolly-Way
      @Jolly-Way 4 ปีที่แล้ว

      Thank you very much for your very helpful reply.

    • @Horse-c2t
      @Horse-c2t ปีที่แล้ว +1

      Yeah, the cost is not worth it. Just buy a new one. If the coils have a hole anyway, you won’t have any choice.

  • @sonyyoung1036
    @sonyyoung1036 2 ปีที่แล้ว

    Great video. Can you confirm where you installed the valve? Is it installed at the line coming out of the compressor where the freon has been compressed to a liquid?

    • @inhocsigno9151
      @inhocsigno9151 2 ปีที่แล้ว

      NO! Low Pressure side or Suction side. High pressure side could explode the can.

  • @shenvalpress3535
    @shenvalpress3535 ปีที่แล้ว

    I see you use R410A. It's not available to the DYIer it seems. Can R-32 suffice?

  • @victoryfirst2878
    @victoryfirst2878 4 ปีที่แล้ว +1

    Why does the the line first freeze up and then stop ??? Can you put in a sealer with the gas to keep the unit from losing the gas ???

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว +1

      Many of the recharge kits have a sealant and UV dye indicator in the gas mix - the 410a kit that I purchased (Amazon) had that.

    • @victoryfirst2878
      @victoryfirst2878 4 ปีที่แล้ว

      @@paulmoffat9306 Thanks Paul for the information fella. VF

  • @patrickhurley707
    @patrickhurley707 3 ปีที่แล้ว +2

    Did he provide the source for the filler device and Freon?

  • @jerrychan1471
    @jerrychan1471 4 ปีที่แล้ว +1

    Thank you for sharing this info. It was very helpful!

  • @winna101ify
    @winna101ify 4 หลายเดือนก่อน

    It would be nice if the type of refrigerent was stated in the video

    • @ranger178
      @ranger178 หลายเดือนก่อน

      you have to look at plate on dehumidifier it tells you which yours uses

  • @ghostridergr8259
    @ghostridergr8259 2 ปีที่แล้ว

    i have ice to the first pipe or evaporator is noemal? how much is the the lowest temp to the evaporator in room temperature????? and how mutc is the highest temp to the compressor?? the ice.in the beginning of evaporator and before it is Normal??? i dont know how mutc gramms 407 i must put

  • @DEtchells
    @DEtchells 3 ปีที่แล้ว

    This is great, super helpful - Thanks!!

  • @lordbyronofbedford5183
    @lordbyronofbedford5183 2 ปีที่แล้ว

    I have 3 units that need charging. How much refrigerant does one unit take approximately? Do I need to buy 5 pound tank?

  • @Jolly-Way
    @Jolly-Way 5 ปีที่แล้ว +1

    Your straightforward demonstration on how to recharge a faltered dehumidifier encouraged me to try it also. I would like to have your private email as I have some other questions.

  • @yaoypl
    @yaoypl 6 ปีที่แล้ว +4

    You must have a leak issue.. Did you fix the coil leak before your recharge?

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว +1

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว +2

      Most recharge kits, have the gas mixed with a UV leak marker and a sealing agent - that is why he was shaking the can to keep it mixed. Once filled, and running for a while, a UV light can show where the leaks are present. If the leak is a tiny pin hole, the sealant should do its job.

  • @gerggry
    @gerggry 4 ปีที่แล้ว +2

    How long did it continue to run before needing another charge? I didn't see you address any leaks so I have to assume that's a temporary fix...

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว +3

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @keninatlanta8452
      @keninatlanta8452 4 ปีที่แล้ว +5

      @@zachqueen8316 Can you provide just one textual reference that backs up your statement. These are closed systems engineered so the refrigerant is compatible with the oil. Here is a link from ACHR-News describing how oil and refrigerant react in an HVAC system. No mention of refrigerant breakdown over time. www.achrnews.com/articles/135762-inside-refrigerant-and-oil-relationships

    • @clintonrh
      @clintonrh 3 ปีที่แล้ว +3

      Ken is correct. There should be no refrigerant loss. These closed systems should run with no loss for 20 years. The fact that this is a new dehumidifier means there is a definite leak in the system that should have been addressed first! I do not recommend people doing what he did. Bullet valves are only good for a couple of years at most and are not intended to be opened and closed multiple times (this causes them to start leaking). The fact that he used a bullet valve, refused to repair the leak, and did not properly measure the refrigerant pressure in the system are all indicators that this unit will not function for very long or at efficiency level. This is why you do not buy used items like this on eBay. People like him are doing this and the units go bad in as month or two! Very bad repair video!

    • @精萃篇
      @精萃篇 3 ปีที่แล้ว

      @@clintonrh My dehumidifier did not collect water. I wonder how can I check the leaks that you just mentioned?

    • @clintonrh
      @clintonrh 3 ปีที่แล้ว +2

      @@精萃篇 Try adding something like cliplight super seal. It is for a/c systems and repairs leaks in the metal parts as well. The cheap stop leak products only work on non metal leaks so make sure what you get will repair metal leaks. Do not add the entire amount. Only about 1/4 of the canister. After it has circulated through the system, turn it off for a couple hours then turn it back on and refill with refrigerant. Before you do any of this, make sure the compressor is working. If the compressor is running but the coils do not get cold, the problem is low refrigerant. If you want to find the exact position of the leak, you can use an auto ac leak detector. The easiest way is to just use a leak repair sealant. Just be careful not to add too much sealant as it will limit how much refrigerant you can add.

  • @curthatch8092
    @curthatch8092 3 ปีที่แล้ว +1

    Why could your not hold the R410A bottle the other way up and put gas into the system instead of liquid since liquid could be a problem to the compressor?

    • @tony17112acst
      @tony17112acst หลายเดือนก่อน

      R410a is azeotropic; it's a mixture of more than one refrigerant and must be charged as a liquid. Otherwise the different gasses will exit at different rates and will change the perfect mixture proportion of the mixed refrigerants.

  • @flyingdaworld
    @flyingdaworld 3 ปีที่แล้ว

    I just purchased a secondhand refrigerant R290 dehumidifier. It’s called the corlitec dehumidifier. How do I know if it’s operating well? I’m afraid of a potential gas leak/carbon monoxide leak. Is a refrigerant dehumidifier capable of doing those things? Thank you.

    • @Joopsmann
      @Joopsmann 2 ปีที่แล้ว +1

      You’ll know it’s operating well when it dries a damp area. The evaporator coil gets cold to do that. If it isn’t pulling moisture from the air, it’s not working. Carbon monoxide leaks wouldn’t be possible. That’s an issue with natural gas or propane furnaces and water heaters. A refrigerant leak is possible. Toxicity isn’t a huge issue with a small system like a home dehumidifier. It can be with bigger systems.

    • @flyingdaworld
      @flyingdaworld 2 ปีที่แล้ว

      @@Joopsmann thank you for your reply! Would you say a completely electrical appliance is safer than a gas-run appliance?

    • @Joopsmann
      @Joopsmann 2 ปีที่แล้ว

      @@flyingdaworld I wouldn't say that gas appliances are "unsafe," just make sure your furnace flue is not blocked by leaves or a squirrel nest, etc. Not a bad idea to have a CO detector/alarm just like you most likely have a smoke detector. Your dehumidifier is electric though, right? (Electric motors turn the compressor and fan?)

  • @prolinelectricful
    @prolinelectricful 3 ปีที่แล้ว +3

    How many more times can you say uhh uhh? Damn

  • @michelstellato6395
    @michelstellato6395 4 ปีที่แล้ว +1

    hi my dehumidifier Dandy need R410A, can Top it with another gaz, mixing with another gaz is ok or not, because a live in Canada and I find not R410A in automotive store

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว +1

      Another gas is not ok the oils are not compatible. R410a is alot more expensive than r134a and is not sold it automotive stores as cars do not use 410a only 134a. If you mix the two refrigerants the oils will make a curdled milk like substance and destroy the compressor.

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว

      You can find vendors for a recharge kit for R410a on eBay (about $135 US), and they do ship to Canada.

  • @tskipwadoo3447
    @tskipwadoo3447 4 ปีที่แล้ว

    It makes total sense now, thank you for this vid.

  • @viktorsologub6837
    @viktorsologub6837 3 หลายเดือนก่อน

    What the heck you get the valve in I take my dehumidifier part no valve to charge BS, and I have same exact brand Hisense

    • @ranger178
      @ranger178 หลายเดือนก่อน

      you buy valve and clamp it onto the pipe on cold low pressure line then turn center to push pin into line

  • @joehawthorn3018
    @joehawthorn3018 ปีที่แล้ว

    My dehumidifier takes r22, can i put in 410

  • @roxyv8750
    @roxyv8750 4 ปีที่แล้ว

    I have Amana dehumidifier D970E-E and is not collecting water anymore. I assume I run out of Freon. Where can i find small quantity of freon. I assume should be R410A

    • @inhocsigno9151
      @inhocsigno9151 2 ปีที่แล้ว

      The label on the compressor should state what gas is used, and how much.tnks

  • @user-er6lz9nq4z
    @user-er6lz9nq4z 2 ปีที่แล้ว

    where did you get your gauge a push valve with hose , and the 410a

  • @Homer19521
    @Homer19521 5 ปีที่แล้ว

    My 70 pint Hisense almost quit working. Just a little part of the condenser coil is cold. But I notice the compressor is very hot. Is that because it is low on freon or do they all get blazing hot? Thanx for the video.

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว +1

      All the compressors get hot. Heat is a byproduct of compressing the refrigerant. As a fluid is compressed it gets colder therefore heat is released and as the refrigerant expands it gets warmer therefore heat is absorbed from the air this the reason the coils get cold or in the case of low refrigerant the refrigerant expands too much and the coils freeze over. If you have the correct amount of refrigerant in the system the coils will only condensate which is how the water is removed from the air.

    • @Homer19521
      @Homer19521 4 ปีที่แล้ว +1

      @@zachqueen8316 ZQ - I understand the concept of LHV (Latent Heat of Vaporization). I just wanted to know how hot does the typical dehumidifier compressor get. Maybe I didn't make that clear. Is 120F normal? 160F? 180F????

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว

      Yeah sorry I didn't realize that. Most people don't realize understand it so I just figured I would post it in the event you didn't understand it. Typically though under normal operation they get hot enough that you can't typically hold your hand on them very long but not typically hot enough to burn instantly. As for specific operating temperature that I could not give you.

    • @ranckie
      @ranckie 4 ปีที่แล้ว

      @@zachqueen8316 In that case, a normal human hand can usually withstand about 125 degrees of heat before most people have to let go, so it sounds like based on your description, the compressor may get to be around 130 degrees or so F.

    • @inhocsigno9151
      @inhocsigno9151 2 ปีที่แล้ว

      @@zachqueen8316 Just to note that fluid can not be compressed. When gas is compressed by the compressor, the gas get hotter. The compr output line will be hot. When the gas goes thru the condensor coil it cools and condenses into a liquid. As the liquid goes thru the fixed orifice, it expands into a gas, cooling the coils. Your explanation on why coils freeze up sounds good.

  • @289r
    @289r 2 ปีที่แล้ว

    How much pressure in psi should the gauge show

  • @troyarthur829
    @troyarthur829 3 ปีที่แล้ว

    Love the video, its a great help, but the word is “Thaw” not “unthaw” which actually means “Freeze”... LOL... Sorry about that...

  • @16DeathCore
    @16DeathCore 5 ปีที่แล้ว +1

    Where did you get the hose ? Have Freon from auto parts store but it’s the quick disconnect not screw oh

    • @reganlebaron7103
      @reganlebaron7103 5 ปีที่แล้ว

      Hi, the hose came with the Freon kit, but you can get the connectors on eBay cheap, thanks for Watching

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว

      Don't use r134a it is not compatible with anything except r134a. If you aren't sure what refrigerant to use it should be marked on the compressor with the type of refrigerant and I compacity of refrigerant as well as the amount of oil required.

  • @jasondepriest326
    @jasondepriest326 4 ปีที่แล้ว +1

    brilliant!

  • @kodak_jack
    @kodak_jack 2 ปีที่แล้ว +1

    Do your viewers a favor and link to what you used in this video.
    When the system is charged properly, the frost will flash away and you're done.

  • @josephmeckel7070
    @josephmeckel7070 ปีที่แล้ว

    Where did you purchase the R410a refrigerant???

    • @Calliber50
      @Calliber50 7 หลายเดือนก่อน

      I got mine off ebay. Frosty-Freeze A/C Products Company. Just be careful. The cans may come with a little metal cap on the bottle. When unscrewing that cap, make sure you're in a room with no breakable items like windows or your fine china collection. Point the cap away from your face and slowly unscrew it. There may be substantial pressure and that cap will shoot off like a bullet. I was an idiot. Package arrived, I opened the box, I loosened the cap, there was a loud bang. Scared me, scared the dog, the wife screamed. The cap shot past my face and ricochet off a mirror. So I highly recommend a face shield or safety glasses when messing with these things.

  • @PRIDEMARTIALARTS
    @PRIDEMARTIALARTS 4 ปีที่แล้ว

    If my dehumidifier is blowing hot air is that a sign it needs freon?

  • @Dungtran-oc2hp
    @Dungtran-oc2hp 2 ปีที่แล้ว

    What the brand of Freon ?

  • @mikemccartney59
    @mikemccartney59 5 หลายเดือนก่อน

    Any idea of E2 error on a Hisense?

  • @addmealready
    @addmealready 4 ปีที่แล้ว

    Does the dehumidifier have to be operating in order to remove the freon?

    • @normbutton537
      @normbutton537 3 ปีที่แล้ว

      No they apply a vacuum pump and draw the freon out

  • @nicolasrodriguez2440
    @nicolasrodriguez2440 5 ปีที่แล้ว +1

    Hello! I really like your videos. Thanks for uploading them!!
    I wonder why a dehumidifier loses refrigerant so that it requires some recharging. I mean, does a refrigerant fade with no leaking in the system?
    I'd appreciate your kind reply.

    • @reganlebaron7103
      @reganlebaron7103 5 ปีที่แล้ว

      I bought this unit as a refurbished item, I am going to assume that there must be a small leak some where, it’s a closed system, and theoretically it should not lose any refrigerant, Jon has a good explanation on charging in a previous comment.
      Thanks for Watching

    • @0GSoon
      @0GSoon 5 ปีที่แล้ว

      I mad with the manufacture, new unit lasts only few years. Broken fan, noise or run dry on freon... too much problems...end up in scrap yard.

    • @petergabriel2593
      @petergabriel2593 5 ปีที่แล้ว

      qiansview m

    • @zachqueen8316
      @zachqueen8316 4 ปีที่แล้ว +1

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @jonweigel2806
      @jonweigel2806 3 ปีที่แล้ว +1

      @@zachqueen8316 Freon doesn't wear out!! I have worked on units made 70 years ago! I can't imagine where you heard this, surely not from a competent repairman!

  • @DTNTNNTTN7065
    @DTNTNNTTN7065 4 ปีที่แล้ว

    what is suction psi would be it normal surrounding like 72 degree

  • @gareld12
    @gareld12 4 ปีที่แล้ว

    thanks im going to try this , im a techy ,like new stuff,

  • @byron821
    @byron821 3 หลายเดือนก่อน

    This makes no sense to me.... the freon leaked out but you didn't repair the leak. It's just going to leak out again? I've had several dehumidifier units. None of them lasted more than 2 years. Why can't any American company make a dehumidifier that LASTS?

  • @c.rutherford
    @c.rutherford 4 หลายเดือนก่อน

    This is no longer possible as the manufacturers have all conveniently discontinued R134a dehumidifiers which were the only ones that could realistically be recharged- even though they run better. Most have also switched to ridiculously short 1 year warranties.
    Planned obsolesence.

  • @dave1026
    @dave1026 4 ปีที่แล้ว +7

    What it's actually doing is thawing. To dethaw or unthaw is to freeze.

  • @virusvirus3701
    @virusvirus3701 ปีที่แล้ว

    how to remove freon from dehumidifier

  • @g1g1420
    @g1g1420 ปีที่แล้ว

    That's the evaporator

  • @1marcelfilms
    @1marcelfilms ปีที่แล้ว

    Can i put propane in my r22 vintage AC ?
    Cant buy any refrigerants here in europe

  • @michaeldowling9120
    @michaeldowling9120 4 ปีที่แล้ว

    Can you use r134 instead?

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว

      No, should be same type to be compatible. Check the unit's label to verify the gas used.

  • @772777777777777
    @772777777777777 ปีที่แล้ว

    Most unit do not have the shudder value on the unit

  • @chevy77rock
    @chevy77rock 6 ปีที่แล้ว

    What type of freon do you use?

    • @reganlebaron7103
      @reganlebaron7103 6 ปีที่แล้ว +3

      My system uses r410, yours may use a different Freon, check the label on the side of the compressor, or on the side of the unit
      Thanks

  • @ardiemclelland2039
    @ardiemclelland2039 5 ปีที่แล้ว +4

    Buy an old dehumidifier and you’ll never have a leak issue.

  • @Jon-hx7pe
    @Jon-hx7pe 5 ปีที่แล้ว +9

    This isn't an accurate charging method. It will get the machine running, not necessarily optimally and there's a possibility of liquid refrigerant getting back to the compressor. You can overcharge or undercharge depending on the operating conditions. There's no required psi, it greatly varies depending on the operating conditions and design of the unit.
    DIY kits like this aren't good because they increase the likelyhood of the work being done incorrectly. Need recovery machine, proper gauges, thermometers, vacuum pump, brazing torch, nitrogen, plus knowledge of theory to do refrigeration work correctly. People think charging is like inflating a tire.
    These units have fixed metering devices, so there are two valid methods:
    1. Superheat - temperature rise above boiling point. boiling point determined by pressure and sunction refrigerant temp measured with insulated or clamp thermometer. Subtract measured temp from saturation temp. Normally the required superheat depends on the operating conditions and there are tables indicating what the superheat should be for a/c. But in a dehumidifier application, because the condenser is cooled by cold air from the evap coil and the temp of the cold air is proportional to the load on the evap coil, it should stay pretty consistent. It should be anywhere from 5 to 15F degrees. The ideal superheat is 0 with no liquid getting to the compressor, but manufacturers design for above that to be sure no liquid gets back.
    2. Weight, which requires recovering all the refrigerant and weighting in the amount on the rating plate. This is the best method for small appliances like this.

    • @reganlebaron7103
      @reganlebaron7103 5 ปีที่แล้ว

      Thanks for the explanation, thanks for Watching

    • @ilovefunnyamv2nd
      @ilovefunnyamv2nd 4 ปีที่แล้ว

      Yeah, but accurate would be sending it back to the factory with the people who made it 6-12 years ago, next best would be a licensed HVAC specialist familiar with the process and coolants, if not this specific model. But still, if you were going to throw it out and buy a new anyway....

    • @Jon-hx7pe
      @Jon-hx7pe 4 ปีที่แล้ว

      the charge can be weighed in, the amount of refrigerant is on the rating plate. can also get it very close to factory checking superheat/subcool.

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว

      @@Jon-hx7pe That method works it the unit is emptied of it's remaining gas load.

    • @paulmoffat9306
      @paulmoffat9306 4 ปีที่แล้ว +1

      @@ilovefunnyamv2nd Most HVAC don't want to service a small unit - not enough money for the call. They may service it if you bring it to their shop.

  • @kriskringle913
    @kriskringle913 5 ปีที่แล้ว

    Curious what if dehumidifier not blowing hot air, coils not cold, low refrigerant?

  • @bladder1010
    @bladder1010 4 ปีที่แล้ว +2

    But where can I get r410a freon? I can't seem to find a bottle like you have for sale to the public anywhere?

    • @AS-TIGTV
      @AS-TIGTV 4 ปีที่แล้ว

      If you're humidifier needs r410a, only licensed person can purchase the freon and that is by law implementation.

    • @bobs7597
      @bobs7597 3 ปีที่แล้ว

      410a is not restricted. Can be found on the internet ......it’s not cheap, but it’s available to the general public.

    • @bladder1010
      @bladder1010 3 ปีที่แล้ว

      @@bobs7597 So, basically, my dehumidifier is garbage. No economical way to recharge it.

    • @stevescherer4954
      @stevescherer4954 3 ปีที่แล้ว

      @@bladder1010 The coils and refrigerant can be recycled and other parts used to repair other units.

  • @chitownvaulter
    @chitownvaulter 5 ปีที่แล้ว

    how much refrigerant was left in the can after you recharged it?? or how many times can you recharge it with one can??

    • @ilovefunnyamv2nd
      @ilovefunnyamv2nd 4 ปีที่แล้ว

      All that depends, When I recharged my car, I used most of a can, when I did my parent's, I think I had to used a can between them

  • @dennisgostas5124
    @dennisgostas5124 5 ปีที่แล้ว +1

    very nice thank you

  • @dandillon5163
    @dandillon5163 2 ปีที่แล้ว +1

    Not worth it. First it’s not fixed. It will need to be charged again and again. Second - valve and Freon cost. If the dehumidifier has a low side leak it may last longer. If it has high side leak it won’t last long at all. Problem dehumidifier is poorly made.

  • @ES-AT
    @ES-AT 3 ปีที่แล้ว

    R410 is not a freon. it is a Puron

  • @PaineStakingTruth
    @PaineStakingTruth 11 หลายเดือนก่อน

    Sorry, the word is “thaw”. That alone means ice or frost is eliminated. De-thaw or un-thaw is nonsensical.

  • @TruePatriot59
    @TruePatriot59 3 ปีที่แล้ว +1

    Not worth fixing...I agree with other comments here...too expensive for the freon and valve.

  • @qtig9490
    @qtig9490 4 ปีที่แล้ว +1

    You are filling on the low pressure side so why not just flip the freon can right side up? That way you dont inject the liquid just the gas which is what you wanto to keep from damaging your compressor with a slug of liquid.

    • @BatByke
      @BatByke 4 ปีที่แล้ว +1

      You cannot charge R410A as gas, only liquid. R401A is a composite of different refrigerants, not a single like R12 and R22, If charged as gas, the lower fraction boils off first giving you the wrong gas, which will change the mixture both in the supply bottle and the device being charged.

  • @knowyuhgrow420
    @knowyuhgrow420 2 ปีที่แล้ว

    👍🏽

  • @g1g1420
    @g1g1420 ปีที่แล้ว

    Still low

  • @chempennllcthechemicalcomp1438
    @chempennllcthechemicalcomp1438 4 ปีที่แล้ว

    Hello,
    thank you for using one of our product in your video. I would like to discuss with you opportunities. Please contact me at sales@chempenn.com at your early convenience.

  • @apher2012
    @apher2012 ปีที่แล้ว

    Need to make a better effort on the way you speak up description, sound like you are trustworthy repair man

  • @holdurhorse9149
    @holdurhorse9149 5 ปีที่แล้ว

    It shouldn't frost at all. The frosting indicates the system is overcharged!
    What is sub cooling limits and over heated vapor rules fall in the play?
    Overcoming would flood the compressor and it eventually get damaged.

    • @bobs7597
      @bobs7597 3 ปีที่แล้ว +3

      Wrong...under charge

  • @Lil_Taco
    @Lil_Taco 2 ปีที่แล้ว

    Just recorded yourself committing a federal offense lmao you can not under any circumstances let refrigerant in the atmosphere

  • @JR-hh8ou
    @JR-hh8ou 3 ปีที่แล้ว +1

    Quit saying you are using Freon you are using refrigerant Freon is a brand name made by DuPont!!! Unless you're using Dupont refrigerant then you may say freon.