🔴 Communication between PLC and Drive🔵

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024
  • basic understanding of PLC and drive Communication.how plc send command to drive.how drive send feedback to plc,plc and drive communication network overview,how to start drive from plc,basic network arrangements of plc and drive.what is logic command word,what is logic status word. Plc to drive communication
    speed and torque mode of VFD
    • 🔴Speed and torque mode...

ความคิดเห็น • 89

  • @naveenkadkol9731
    @naveenkadkol9731 4 ปีที่แล้ว +2

    It was really a good explanation on communication between PLC and drive. Can you please make a video on PLC getting commands from other applications and pass on those communication to drive and vice versa. In short, Application PLC Drive
    Thanks in advance 🙏🙏🙏

  • @bijendrasingh6185
    @bijendrasingh6185 4 ปีที่แล้ว +2

    sir, extremely nice video. please share more videos .your explanation is very conceptual.

  • @r.d.245
    @r.d.245 4 ปีที่แล้ว

    Aap bahot achchhi tarah samjhate ak dam samjh me aa jata h

  • @nagarajukapileswarapu1294
    @nagarajukapileswarapu1294 4 ปีที่แล้ว +1

    Sir your teaching skills are so good please make a video on servo communication too

  • @mdmahtabalam925
    @mdmahtabalam925 5 หลายเดือนก่อน

    nice explained sir

  • @subramaniankrishnakumar3821
    @subramaniankrishnakumar3821 5 ปีที่แล้ว +2

    Brother really thanks. Good teaching skill you have.

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      thanks brother keep watching.. keep supporting.

  • @anandpatel2690
    @anandpatel2690 4 ปีที่แล้ว +1

    Truly helpful
    Thank You.

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Ur vedio very nice , & ur understanding ability so nic. Thanks.

  • @PankajTiwari-di1zq
    @PankajTiwari-di1zq 6 ปีที่แล้ว +2

    Sir thank u so much for this kind of vidio on drives......your explanation is very clean and easy to understand......specially i like to listen "theeek hai n" from u after every sent.....😍😍😍😍😍......nd sir plz make a vidio on master slave drive configuration......how we can operate two drive as master slave .......once agian thankxxxx......

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว +2

      thanks a lot Pankaj god bless you

  • @Mithilesh658
    @Mithilesh658 3 ปีที่แล้ว

    Very nice video sir🙏🙏

  • @vikramkaushik1767
    @vikramkaushik1767 3 ปีที่แล้ว +1

    sir please make a video in continuation of this video: communication between plc and drive

  • @abhishektiv4400
    @abhishektiv4400 3 ปีที่แล้ว

    Good 👍

  • @vinodbankar8942
    @vinodbankar8942 2 ปีที่แล้ว

    👌

  • @Surya.EMF.Automation
    @Surya.EMF.Automation 2 ปีที่แล้ว

    𝐍𝐢𝐜𝐞 𝐄𝐱𝐩𝐥𝐚𝐢𝐧𝐬

  • @rajushaikh5079
    @rajushaikh5079 3 ปีที่แล้ว

    Sir make more video about industrial automation(plc, instrumentation,scada,

  • @mukeshthakur-gu9gp
    @mukeshthakur-gu9gp 5 ปีที่แล้ว +1

    Sir please explain relative or magnetic sensor

  • @parveensinghania8809
    @parveensinghania8809 4 ปีที่แล้ว

    A for Automation please make a vedio on Profibus communication,

  • @nageshpandey5333
    @nageshpandey5333 4 ปีที่แล้ว

    Sir ek video PLC k specifications sheet or chart Ko explain kar k banayiyega

  • @ganeshlande9723
    @ganeshlande9723 ปีที่แล้ว

    Very nice sir
    Thik hai na, repeat mat Karna.

  • @jasinaj5397
    @jasinaj5397 6 ปีที่แล้ว +1

    😘😘😘

  • @sonasharma5627
    @sonasharma5627 5 ปีที่แล้ว

    sir
    siemens ki plc me prog addr karne ke liye .db2.db4 is tarah se use karte h..wo samajh nahi lagta h.can u explain it sir

  • @pankajsanwal2010
    @pankajsanwal2010 4 ปีที่แล้ว

    8 bit ya 16 bit ke adopter same honge ya different ? Unke cable bhi alag honge, optical fibre cabe ko chhodkar ? Kyonki whan par to do hi cable hote hain ek input ke liye doosra output ke liye .

    • @aforautomation
      @aforautomation  4 ปีที่แล้ว

      Adapter and other hardware depends upon the type of PLC is used and communication network.

  • @nageshpandey5333
    @nageshpandey5333 4 ปีที่แล้ว

    Sir please make a video with program in Siemens and abb PLC and drives

  • @sushilkumarshukla9476
    @sushilkumarshukla9476 4 ปีที่แล้ว +1

    Dear sir please provide an lecture on IMCC panel and their communication with plc for feedback and control

  • @r.d.245
    @r.d.245 4 ปีที่แล้ว

    Nice Sr ji⚘⚘⚘
    Sr ji mujhe ak bat bata jigiy a jo bit 1 ya 0 bit y kya 24 DC v me jata h y bit kaise apana signal bhejata h frequency dwar ya kis tarah se please batane ki kripa kare msg dwara ya kisi bhi tarike plg sr

  • @pardeepsharma8657
    @pardeepsharma8657 6 ปีที่แล้ว

    Good

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      in next video i will upload practical example of this video so keep watching and subscribe my channel if you like this type of content

  • @mukeshthakur-gu9gp
    @mukeshthakur-gu9gp 5 ปีที่แล้ว

    Thank you sir

  • @shashankkumar7770
    @shashankkumar7770 3 ปีที่แล้ว

    Please make videos on profibus tracer

  • @anushkakiranlamba9046
    @anushkakiranlamba9046 5 ปีที่แล้ว +1

    sir PPO, PZD, PKW kya hota hai drive mai.....aur plc kaise isko use karta hai, iske bare mai please video banaiye

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      I think thease are the name of TAG or memory location in PLC program , have you seen these names in drive parameter/user manual ?
      I am not sure but it may be short form of some machine name.
      Where did you saw thease words please reply then i can understand better.

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      support.industry.siemens.com/tf/WW/en/posts/meaning-of-ppo-pzd-and-pkw/156488?page=0&pageSize=10
      Go in above link you will find answer

    • @anushkakiranlamba9046
      @anushkakiranlamba9046 5 ปีที่แล้ว +1

      Sir, I was trying to establish communication between siemens plc and abb dcs 800 drive through profibus. The PPO term came into picture after I installed the GSD file for abb drive. Then we have to select I/O type( here I got one option as PPO type 1,2,3,4 or 5), so that the plc can R/W data from drive.

  • @anshulkumar-kl4pr
    @anshulkumar-kl4pr 6 ปีที่แล้ว

    Sir yahi baat computer par bataiye very good video

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      th-cam.com/video/Q-IMfwXEJk8/w-d-xo.html

  • @atiqrehman8001
    @atiqrehman8001 6 ปีที่แล้ว +1

    I am second great work sir.
    God bless you.

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Plz tell me with details of LSW .thanks

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Agar aapki vedio starting se dekhne ko mil jaye toh aur better samajh me aayga.

  • @vasudevpandya2424
    @vasudevpandya2424 5 ปีที่แล้ว

    Please sir one more vidio of communication between pid and drive

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      i will make lot more.stay connected and thank you so much for watching..

  • @chauhanvijaysinh7737
    @chauhanvijaysinh7737 5 ปีที่แล้ว

    Nice sir most usefull lacture

  • @mueezkhan4429
    @mueezkhan4429 4 ปีที่แล้ว

    Sir make a more video with program abb

  • @KrishnaSingh-sm4nc
    @KrishnaSingh-sm4nc 6 ปีที่แล้ว

    hii sir vfd ka work kart a hu kiya ap iski repairing bta skte ho

  • @syedsaad5781
    @syedsaad5781 2 ปีที่แล้ว

    Ager communication time out error ata hai
    To is fault ko kis tarah remove kia ja sakta hai

    • @aforautomation
      @aforautomation  2 ปีที่แล้ว

      there are some time out time settings in communication parameters, you can increase the time or baud rate is to be decreased in communication parameters,check cable and change its route if possible

  • @majanudeewana9831
    @majanudeewana9831 4 ปีที่แล้ว

    Sir
    Riley
    Motor
    Sensor
    Atocot
    Speet setting
    Video

  • @pankajsanwal2010
    @pankajsanwal2010 4 ปีที่แล้ว

    Sir LCW main 10th se 15th number tak ke bit ke section main jo command honi chahiye wahan par cross mark kiya hua hai . Iski kya wajah hai kya wahan par zero ya one kuchh nahi ho sakta hai ?

    • @aforautomation
      @aforautomation  4 ปีที่แล้ว +1

      X means thease bit are not used they are reserved for future upgradation.jab drive ka new version ayega to in bits ko use kiya jayega kuch new command add karne k liye.

    • @pankajsanwal2010
      @pankajsanwal2010 4 ปีที่แล้ว

      Thanks

  • @syedadnanmoin2111
    @syedadnanmoin2111 5 ปีที่แล้ว

    Hi...
    What will be the reference address for logic command word to send command to drive

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      There are Fixed address for thease commnads, when we configure hardware and connect in network which is used to communicate with PLC, some address tags are generated in PLC memory like for unwinder it will show like Uncoiler:O.Logiccommand

    • @syedadnanmoin2111
      @syedadnanmoin2111 5 ปีที่แล้ว

      OK... And need to set any parameters of VFD for reciving data?.. Actually having trouble in fetching the data from ACS550 drive..
      Any suggestions will be helpfull

  • @tekramsahu9050
    @tekramsahu9050 5 ปีที่แล้ว

    sir plc se, realy k thrue drive ko dete hai kya?

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      Nahi this video is regarding communication through Network

  • @raselrana9528
    @raselrana9528 2 ปีที่แล้ว

    Allen Bradley 20-comm-p Profibus vfd speed problem

    • @aforautomation
      @aforautomation  2 ปีที่แล้ว

      what is problem like speed is less or speed reference is not working?

  • @suhelansari7048
    @suhelansari7048 6 ปีที่แล้ว

    sir ek bar precticaly vfd me parameter bhar ke video banao na

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      next video practical hoga keep in touch brother

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Lsw se matlab aapka drive feedback se hai kya

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      yes logic status word ye drive ka status ka feedback hota hai jo plc ko jata hai

  • @angadgupta7737
    @angadgupta7737 4 ปีที่แล้ว

    Sir ji
    CPU and drive ke beech jo cable lagata hai use kaun sa cable kahte hain

    • @aforautomation
      @aforautomation  4 ปีที่แล้ว +1

      Cable bahut si type ki ho sakti hain jaise ki Profibus/Ethernet/Controlnet/Can bus/Modbus ye sab plc k type aur network requirement k hisab se design kiya jata hai. jaise ki plc aur drive k bich me distance kitna hai,Total drive kitne add karne hain etc.

    • @angadgupta7737
      @angadgupta7737 4 ปีที่แล้ว

      @@aforautomation thank you sir ji

    • @angadgupta7737
      @angadgupta7737 4 ปีที่แล้ว

      Sir ji program ko kaise upload karte hain usper video banaiye please

  • @kaatnikaatni9012
    @kaatnikaatni9012 5 ปีที่แล้ว

    Sir what is Enable on Drive?

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว

      Enable is a digital input which is reserved for emergency stop some time this input comes from from plc and sumtimes through hard wire wiring.this is for safety purpose and it never should be bypassed.if drive does not receive this input motor will stop immediately .and this stop will be coast to stop

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Sir apki vedio starting se kaise dekh sakta hu.

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      channel k naam pe click karo jahan A For Automation likha hai phir upar video pe click karo sare video ki list open ho jayegi

  • @bhupenderbhati7
    @bhupenderbhati7 6 ปีที่แล้ว

    Sir ji logic status word se jo command jati hai vo plc me jati hai kya.agar jati hai toh ye plc ke liye kya hoti aur drive ke liye kya hoti hai.

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      lsw drive se plc me jata hai as a.feedback jaise ki drive ready,drive running, drive faulty etc..

    • @bhupenderbhati7
      @bhupenderbhati7 6 ปีที่แล้ว

      @@aforautomation , sorry sir but one more question ,LCW will connect with input plc module or output module.I mean that LCW will be for plc input or output

    • @aforautomation
      @aforautomation  6 ปีที่แล้ว

      LSW input ya output module me nahi jata ye direct communication cable se plc me pahuch jata hai..

    • @bhupenderbhati7
      @bhupenderbhati7 6 ปีที่แล้ว

      @@aforautomation , thanks sir , I understand.

    • @bhupenderbhati7
      @bhupenderbhati7 6 ปีที่แล้ว

      Running, faulted, enabled & jog rev etc ko indicate karne ke liye plc se lamp(24 v) on karate hai.

  • @thakorjagdish9616
    @thakorjagdish9616 5 ปีที่แล้ว

    Schneider drive or yaskawa drive communications kase kare please sir

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว +1

      which network you want to use ?
      or you can use analogue input output for speed reference and feedback

  • @vishalgovekar6369
    @vishalgovekar6369 5 ปีที่แล้ว

    Please do practically

    • @aforautomation
      @aforautomation  5 ปีที่แล้ว +1

      th-cam.com/video/Q-IMfwXEJk8/w-d-xo.html
      this is one practical example of same i will make some more for more clarification.
      thanks for watching.

  • @angadgupta7737
    @angadgupta7737 4 ปีที่แล้ว

    Hello sir ji

  • @edgaregan2421
    @edgaregan2421 3 ปีที่แล้ว

    English please?

  • @akhtarshamim2424
    @akhtarshamim2424 4 ปีที่แล้ว

    Hi

  • @Surya.EMF.Automation
    @Surya.EMF.Automation 2 ปีที่แล้ว

    𝐈𝐬𝐤𝐚 𝐝𝐮𝐬𝐫𝐚 𝐩𝐚𝐫𝐭 𝐤𝐚𝐛 𝐚𝐚𝐲𝐞𝐠𝐚