Boiler Training Class, Parts, Operation, Zoning, Explained!

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 พ.ย. 2024

ความคิดเห็น • 287

  • @uwetoob9265
    @uwetoob9265 2 ปีที่แล้ว +81

    This is the best video about boiler function that I have found since searching and watching for the last 3-4 years. Absolutely a great teacher.

    • @uwetoob9265
      @uwetoob9265 2 ปีที่แล้ว +2

      Blows This Old House right out of the water !

    • @AngelR1987
      @AngelR1987 11 หลายเดือนก่อน

      For you. I didn’t get better at anything with this vid

  • @kevinfeil5337
    @kevinfeil5337 ปีที่แล้ว +9

    Currently, in my advanced school level 3 of my plumbing apprenticeship. I'm watching this to simplify boilers, and this guy did a fantastic job 👏 ... must appreciate people who can wrap their heads around this stuff.

  • @stevesingleton3133
    @stevesingleton3133 ปีที่แล้ว +2

    I love how you explain things Step by Step. This is how one is supposed to teach. Thx please keep doing these videos.

  • @edwinjewell5359
    @edwinjewell5359 2 ปีที่แล้ว +7

    Sir you are the Best
    Instructor I have
    Ever heard. Thank's

  • @patrickquirk3859
    @patrickquirk3859 ปีที่แล้ว +1

    Just purchased a home with a boiler system, thank you for making this easy to understand.

  • @StanleyHalas
    @StanleyHalas 2 ปีที่แล้ว +32

    I've been learning boilers for 2 years now and I really appreciate stuff like this. I learned a little and reaffirmed that I'm actually doing things and understanding them correctly. Just did my first steam boiler install

    • @BigTuskk
      @BigTuskk 17 วันที่ผ่านมา

      How’s it going?

  • @Nextlevup
    @Nextlevup ปีที่แล้ว +3

    I would love to work side by side with this man. Perfect teacher

  • @dronetherapy5800
    @dronetherapy5800 2 ปีที่แล้ว +13

    Great explanation! I wish there was another same video on a regular house (2500sqf max) where we would see an older boiler and all necessary components that should be there.
    Thanks again!

  • @yosefyaffee5912
    @yosefyaffee5912 2 ปีที่แล้ว +11

    I’m a plumber and all of ur videos are truly amazing!! Maybe u can make more on boilers? Thank you so much!

  • @00ABBITT00
    @00ABBITT00 ปีที่แล้ว +1

    I learn more from these videos than I do in trade school and it’s not even close.

    • @acservicetechchannel
      @acservicetechchannel  ปีที่แล้ว

      So sorry that you didn't learn more in trade school!! Thats a shame!

  • @johnliu7631
    @johnliu7631 ปีที่แล้ว

    This is the best, NO1 boiler training Video in my life.

  • @anthonyspadafora1384
    @anthonyspadafora1384 2 ปีที่แล้ว +3

    Very well done. Just want to point out a few things that will make our lives go easier. Install a ball valve after the auto feed so you can isolate the feed valve from both incoming water pressure and boiler side pressure. The quality of these feed valves is not what they were 30 years ago and they must be replaced more often. Maybe a little more explanation on why the mixing valve is just a high temperature stop when used on a system with outdoor reset and mixed temperature supplies. My last pet peeve is what is a very common mistake. Always install a drain valve between the expansion tank isolation valve and the tank. These bladder tanks must have their air pressure checked every season. The only way to do this is to isolate the tank and remove the water pressure from inside the tank. Your other options would be to take a bath or introduce a lot of air into the system. Great video Thanks

  • @deanmartin1966
    @deanmartin1966 2 ปีที่แล้ว +7

    I definitely need a refresher on this. Thanks for sharing

  • @joe800096
    @joe800096 2 ปีที่แล้ว

    Very good, straightforward description of how a Residential Boiler system works. Thanks very much for posting.

  • @kevinfinnerty3754
    @kevinfinnerty3754 ปีที่แล้ว

    If only every job was set up this way. Great video

  • @steve19841117
    @steve19841117 2 ปีที่แล้ว +1

    men ! you are the god of HVAC. thanks for upload

  • @joemartinez7765
    @joemartinez7765 2 ปีที่แล้ว +1

    Your the man . Thank you. Wow.
    Piping, piping plus how to design a combo system.

  • @kyleh1974
    @kyleh1974 2 ปีที่แล้ว +4

    I would love a video on primary/secondary piping. Thank you for what you do!

  • @jacobmillard7792
    @jacobmillard7792 11 หลายเดือนก่อน

    Great informative video! I have been doing Residebtial HVAC for about 8 years now, i haven't done a ton of boiler work though, so im trying to better understand them to help further progress my career. You did a great job explaining some basic boiler functions and components. I'm a huge fan of your channel, and there have been a few instances where you have helped me better understand something so that I can diagnose a problem more effectively. Thank you for the content and willingness to share your knowledge and experience with us for free!

    • @acservicetechchannel
      @acservicetechchannel  10 หลายเดือนก่อน

      Thank you for watching our videos and for sharing your insight and experience in the field! Hearing the stories and struggles of technicians is the most rewarding part of it all!!

  • @chillguy8916
    @chillguy8916 2 ปีที่แล้ว +2

    Great video, I just got done with hydronic heating class and this video coved the whole class in a few minutes lol

  • @mava5634
    @mava5634 ปีที่แล้ว

    very well explained. i am sure this man knows his job well

  • @integrity5264
    @integrity5264 2 ปีที่แล้ว +3

    great job explaining everything. My compliments to the installer, neat and clean

  • @bozly209
    @bozly209 หลายเดือนก่อน

    Great video. One thing I would do is wrap those mc power cables to keep them off of the copper tubing.

  • @brianmcdermott1718
    @brianmcdermott1718 2 ปีที่แล้ว +1

    Thank you Craig. An excellant explanation of a combi boiler and controls .. Thanks again.

  • @zahedaminullah6934
    @zahedaminullah6934 2 ปีที่แล้ว +2

    Well explained as always Craig. Good job! I always get intimidated by seeing all that piping. The way you narrowed it down makes me confident now.

  • @ori4640
    @ori4640 2 ปีที่แล้ว

    Perfect presentation, well explained, many thanks for showing how much knowledge is needed as an HVAC/R technician. 👍🙏

  • @chuckrambo2270
    @chuckrambo2270 2 ปีที่แล้ว +1

    Some comments regarding this install: This is a modulating boiler. That’s why there is a range of input/output of 72,000 to 330,000 Btuh. The way that it is setup/installed, though, makes no use of the modulating feature. This means that it never runs lower than its full rated input/output and because of this it will never reach its maximum efficiency. It is also capable of outdoor air temperature reset but this feature is not being used. With outdoor reset the output temperature for space heating will vary depending on how cold it is outside. Instead, it is set to a fixed output temperature for space heating and this is probably why the installer put in all of those mixing valves…to knock the temperature down to a more reasonable level. Outdoor reset takes care of that automatically and that makes better use of the modulating capability of the boiler.
    This boiler has an aluminum heat exchanger which requires a special formulation of antifreeze (aluminum safe inhibited propylene glycol)…always a good thing to mention.
    One more thing that sticks out to me is the lack of dielectric unions where the copper pipe connects to the low-loss header and to the water heater.
    Good basic overview of one type (zone pump) of hydronic heating system. I am sure that there will be additional videos that go much more in depth.

  • @DuragDusse
    @DuragDusse ปีที่แล้ว

    Hands down best boiler explanation video on YT! Appreciate the info and knowledge given in the video!

  • @SailPalarran
    @SailPalarran 10 หลายเดือนก่อน +1

    Your a great instructor, I love the clarity and energy in the video. What a great job in installing that system also. We have done some nice ones but this is probably better / cleaner. Symmetrical always makes the systems look great. It's odd with the natural gas being run in what looks like galvanized pipe. In our area thats a general no-no.

    • @acservicetechchannel
      @acservicetechchannel  10 หลายเดือนก่อน

      Supply houses here by the ocean only sell galvanuzed, local inspectors only approve galv outside here and in the ifgc 2021 code book, there is no distiguishment between using schedule 40 galvanized and schedule 40 black iron, so its technically fine by that code book, thanks!

  • @sidisow572
    @sidisow572 7 หลายเดือนก่อน +1

    Bro you truly are a genius Craig. Thank you bro.

  • @EnjoyCalculus
    @EnjoyCalculus 2 ปีที่แล้ว +3

    Amazing video. Words cannot describe. Thank you so much

  • @devonbailey2480
    @devonbailey2480 ปีที่แล้ว

    I'd love more videos on boilers! Your videos have been extremely helpful for both myself and coworkers. I'd like some information on the different brands, designs, and especially the internal parts of gas and oil-fired boilers. Thank you

  • @somap8380
    @somap8380 2 ปีที่แล้ว +2

    Question; can backflow valve be installed in vertical position OR it has to be only horizontal.
    Wonderful video, Thank you.

  • @brianmcdermott1718
    @brianmcdermott1718 7 หลายเดือนก่อน

    Great detail on boiler and the system. Thank you Craig.

    • @acservicetechchannel
      @acservicetechchannel  7 หลายเดือนก่อน

      I'm glad you liked it! Thank you for watching!!

  • @Blessedrosales
    @Blessedrosales 2 ปีที่แล้ว +3

    Man, I’ve been waiting for you to do a boiler video!!!!! Thank you sir may I have another???!!!!

  • @youngsuit
    @youngsuit 6 หลายเดือนก่อน

    The best episode of Boiler Room

  • @marcusdarnell3348
    @marcusdarnell3348 2 ปีที่แล้ว +1

    Thank you so much Craig! I have a better understanding of hydronic heat!

  • @alexandrostapantaola191
    @alexandrostapantaola191 2 ปีที่แล้ว +4

    More boiler training please!!!🙏🏻

  • @bonbonz3011
    @bonbonz3011 2 ปีที่แล้ว +2

    Great job nice video.
    In our area which is New York, you must add neutralizer for the condensation line

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว

      you really should have a neutralizer on a condensing boiler, no matter where in the world. the problem then is nobody rebuilds them with fresh neutralizer material( often just clean limestone and maybe marble chips)

  • @FarFromPar
    @FarFromPar 2 ปีที่แล้ว +3

    I've been looking for a video like this one. Thanks!

  • @hollywinsman9464
    @hollywinsman9464 2 ปีที่แล้ว

    Wow, what a beautiful video. You are a great instructor.

  • @jfoley1968jf
    @jfoley1968jf 2 ปีที่แล้ว +3

    Great video!!
    Very impressive piping job!!

  • @Jeff-Lawrence
    @Jeff-Lawrence 2 ปีที่แล้ว +3

    Thanks for the fantastic video
    I’m sure it took a lot of time to make
    The only thing I could add is more videos on hydronics and controls please.
    Merry Christmas

  • @boby115
    @boby115 2 ปีที่แล้ว +3

    These systems are most popular around the East Coast ( Massachusetts, New York & New Jersey), very expensive and requires a lot more maintenance compared to a forced air system. Craig did a very good job of explaining this particular hydronic system, along with the domestic hot water 👍. Some things that were concerning to me was uninsulated domestic hot water pipes, his statement about pressure relief pipes needing to be 6 to 8 inchs above floor ( this is incorrect, pressure relief pipes are required to be a maximum of 6" above the floor & not closer than 1" above the floor), exterior low water cutoff not mounted 6" above the height of the boiler's heat exchanger, no condensate neutralizer installed before the sump pump pit, and I am suspect about gas pipe sizing ( a 1-inch fuel run is good for about 40 feet but we have to consider elbows equaling 5 feet and any other gas loads that may be coming off the line). Other than my concerns this looks like a very good install to me.

  • @arnelvlog
    @arnelvlog 2 ปีที่แล้ว +1

    Nice good job for the procedure on how to learn and understand the A/C

  • @whitneyowen8551
    @whitneyowen8551 2 ปีที่แล้ว +2

    So desperately needed! Thank you!

  • @wtfman5313
    @wtfman5313 2 ปีที่แล้ว +2

    Very comprehensive overview! Thank you!

  • @akomar3437
    @akomar3437 2 ปีที่แล้ว +2

    Very well explained. Thanks for sharing your knowledge.

  • @geraldschilli8870
    @geraldschilli8870 ปีที่แล้ว +2

    Good video; except for 3 issues. 1)galvanized gas line; really? 2)where is the pot feeder for chemical treatment of the water. 3)this system would be more efficient if long radius elbows would be used versus short radius elbows. Get back to me on these issues.

  • @ducharmehvactraining925
    @ducharmehvactraining925 2 ปีที่แล้ว +2

    great job Craig as always!

  • @Craigisgreat
    @Craigisgreat 2 ปีที่แล้ว +9

    We needed this! Thank you! Please continue with the boiler training!! 🤙

    • @monirhossain8961
      @monirhossain8961 2 ปีที่แล้ว

      Please let me know how I can join with this course free of charse.

  • @darrenskinner5928
    @darrenskinner5928 2 ปีที่แล้ว +2

    Lots of good information on your channel thanks so much for sharing it

  • @humer101
    @humer101 2 ปีที่แล้ว +1

    Thank you for your time. Great details; the guy takes his time to make a great video. I only disagree that they use a regular PVC in the exhaust; it should be scheduled 80 or CPVC at least the first 10 feet. We have been doing that since 2010.

    • @StanleyHalas
      @StanleyHalas 2 ปีที่แล้ว

      Aren't there some boilers that are specifically designed for pvc exhaust? I've only ever done metal but I've seen boilers that call for pvc

    • @humer101
      @humer101 2 ปีที่แล้ว

      @@StanleyHalas Pvc overtime gets toast, cpvc and sch. 80 last till you died.
      Check.the thickness and you will understand.

    • @StanleyHalas
      @StanleyHalas 2 ปีที่แล้ว +2

      @@humer101 I'm very familiar with the different types of pipe. My comment wasn't about the different types, it was about the manufacturers recommendations

    • @humer101
      @humer101 2 ปีที่แล้ว

      @@StanleyHalas Ryan im doing these boilers for 23 years. I learn that the regular PVC pipes get toast with the pass of time. I cannot longer go by the manufacturers' recommendation. We are the people on the street, I mean on-site, and we learn what happens with most of the stuff.
      Do you think it is better to use sch.40 pipes or sch.80 for the exhaust? Please forget about the manufacturer's recommendation and answer this question.

    • @StanleyHalas
      @StanleyHalas 2 ปีที่แล้ว

      @@humer101 I've never installed anything but metal exhaust for a boiler system. Thats my personal policy. I don't trust plastic for high heat discharge. I've seen installations with pvc though.

  • @kenmassaplumbingheatingair4092
    @kenmassaplumbingheatingair4092 2 ปีที่แล้ว +1

    Hey Craig,
    Really appreciate your passion for the trade!

    • @mansourtommy6555
      @mansourtommy6555 2 ปีที่แล้ว

      Thanks for bringing hydronic systems explanation

  • @lance39478
    @lance39478 2 ปีที่แล้ว +1

    Excellent demo man!.like your show. Please include animations in your future demonstration.

  • @christiamgomez5822
    @christiamgomez5822 2 ปีที่แล้ว

    Best video on TH-cam

  • @thediyguy_handson2901
    @thediyguy_handson2901 2 ปีที่แล้ว

    Hvac god have sent you here to help us!

  • @corbana4743
    @corbana4743 ปีที่แล้ว

    What a valuable information in this video, thanks a lot for taking the time

  • @falconewk
    @falconewk 2 ปีที่แล้ว +1

    Such a great video Craig, thank you so much for sharing!!

  • @anthonytortorice1264
    @anthonytortorice1264 2 ปีที่แล้ว +1

    Awesome video. Thank you again for all your content. I greatly appreciate it.

  • @greekmaster1001
    @greekmaster1001 8 หลายเดือนก่อน

    The backflow preventer should’ve been installed upstream of the tea before the bypass
    Very clean work btw

  • @bobpaulino4714
    @bobpaulino4714 2 ปีที่แล้ว +2

    Hmm, typically LWCO controls that I've worked with on large industrial and institutional boilers (in multiple states over 35+ years) are N.O. and close with water present at a certain level.. One wouldn't want a N.C. switch.
    Much like a draft proof or flow proof switch. They are N.O. switches that close when draft or flow are proven.

    • @boby115
      @boby115 2 ปีที่แล้ว

      I thought the same thing but I think Craig was just not very clear in his explanation. I think he meant it was normally closed when in contact with water, like you I was taught it's what the position of the switch is in when manufactured or in the box ( the normal position with no contact of any kind).👍🛠

  • @ChristopherTrybus
    @ChristopherTrybus 7 หลายเดือนก่อน

    awesome video. would you mind detailing a two zone boiler system (upstairs/downstairs) using a modern combi-boiler without recirculating the dhw. im beginning my training on boilers and would like a simplified understanding of the loop and adding a zone. this video was very helpful.

  • @garysmith9772
    @garysmith9772 2 ปีที่แล้ว +3

    Just wondering if that low-water cut off should be above the top of the boiler just thinking because if the water got down that low that boiler heat exchanger would be toast. Very nice job of explaining the system

    • @bonbonz3011
      @bonbonz3011 2 ปีที่แล้ว +1

      Yes you are right
      Cuz in New York City DOB plumbing division inspector will fail the inspection.
      Unless it's on the top of the boiler for the same reason you mentioned. In general he did a very nice job

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว

      yes, it really should be above the boilers heat exchanger highest point. (since it's not a steam boiler)
      ideally you want it to cut off when or before any circulator pumps run dry, not just the boiler. cartridge pumps cannot be ran dry, the water lubricates the bearing surfaces(often ceramic sleeve on stainless steel shaft)

    • @chuckrambo2270
      @chuckrambo2270 2 ปีที่แล้ว

      Can’t say that I am an expert on Buderus boilers (I would want to see the install guide) but I would agree that a LWCO would generally be located above the boiler heat exchanger.

  • @mangoisback
    @mangoisback 2 ปีที่แล้ว +2

    When are you releasing a book on boilers?!! With topics about steam , hydronic and oil burners

  • @brianleb
    @brianleb 11 หลายเดือนก่อน

    Great job explaining made it very understandable! That said, what an impressive system, compared to mine at home I’m blown away. What would the price range for that setup be?

  • @billythomas7701
    @billythomas7701 7 หลายเดือนก่อน

    Comment is, GREAT Video! My question is, i have a 20 year old boiler with 2 zone valves, one circ pump. The boiler is short cycling and i mean short!! Like boiler will fire and then immediately shut down and i do not know why. I know there could be several possibilities but can you touch on some, or maybe a video on older boilers. Thanks again for the great videos!

  • @DaRealGodBody387
    @DaRealGodBody387 2 ปีที่แล้ว

    Great break down of the system

  • @kingbulldog107
    @kingbulldog107 2 ปีที่แล้ว +1

    absolutely beautiful, I am in my 7th year as a service plumber, and this video is so perfect, just quick question, can those swing checks be spring checks on the domestic and return to the storage tank? if not why?

  • @richrich6235
    @richrich6235 2 ปีที่แล้ว +1

    Hi Craig, do you have any video's or articles on water source heat pumps? Regarding install walkhrough, service, and troubleshooting? Would love to get your insight on these systems. Ive been a tech. for 16 years and yet im always learning something new from your channel. Keep up the good work 👍

  • @PenaR85
    @PenaR85 ปีที่แล้ว

    Im just getting training on boilers now and it's intimidating

  • @phs84
    @phs84 2 ปีที่แล้ว

    Nice video,
    Fairly neat install to except the bucket / tile holding up the calorifier expansion tank, and the back flow prevention should be prior to the quick fill bypass
    How do you add the inhibitor, any dosing pots or do you guys Just crack a nut pour into the pipe work ?

  • @soltannorozi6784
    @soltannorozi6784 2 ปีที่แล้ว

    This is amazing!!! What is the size of the water boiler manifold, return and supply pipes? How do you calculate them?

  • @FrankD-p5s
    @FrankD-p5s 10 หลายเดือนก่อน

    Very good video. I'm having troubles with a zone valve system. Control valves have been disconnected and so the hot water is suppose to evenly spread throughout the entire piping system and have it balanced off return mixing valves and I've been struggling trying to do so. Anythoughts?

  • @JohnDoe-ej1lw
    @JohnDoe-ej1lw 2 ปีที่แล้ว +1

    Great explanation! Thanks for sharing 👍

  • @dominicd2694
    @dominicd2694 7 หลายเดือนก่อน

    A few things I noticed, you are using PVC for your boiler vent pipe which is only rated for 140 F and is against code. You need to use CPVC which is rated for 200 F. Also, there is no condensate neutralizer on the condensate drain. Licensed Refrigeration Mechanic/Heating Technician Toronto, Canada and NATE Certified in USA

  • @nitrofan917
    @nitrofan917 2 ปีที่แล้ว

    That is one heck of a system. Must be a Mansion.

  • @christopherborner1139
    @christopherborner1139 2 ปีที่แล้ว +3

    Great thorough video! Thanks Craig. Couple questions. The drain goes into the sump crock and that condensate water is very acidic and will eat up the pump. Many municipalities do not allow you to drain into the sump. Is that legal where you are? Also the LWCO looks low. If the water level in the boiler got that low, it can ruin the heat exchanger. Is that in the right spot? Thanks again

    • @waymonblevins6939
      @waymonblevins6939 2 ปีที่แล้ว +2

      Christopher, I have worked on Boilers for Thirty Years. One thing that improves and protects boilers tubes and pump is to use DE mineralized water and do a closed Loop System. By doing this You have All the Minerals from the Water removed and You recover the water to a Holding Tank so you never add water to the System. As long as you don't have a leak you never add Water but if You have a leak then add De mineralized Water back to the system. On the Hot Water Tank used a Hot Water Tank that uses a coil in the tank to heat the Water. If You have to drain the system for any reason You can pump the Demineralized Water into a Holding Tank. You are only use about 250 Gallons of Water at the Maximum in all the Lines, Evaporators and the Coils. By doing this You add 5 to 7 years to a Units life. One other thing Never use any Carbon Steel Fittings or Pipes in the Heating System. Carbon Will transfer to Stainless Steel. By doing this You will Add Years of Life to Your System. Carbon and Mineral Water is a Cancer to the System. Any Old Boilermakers and Service Tech's with knowledge will tell You the Same thing. One other thing do a Boiler Chemistry Test by doing this it will Tell You the state of your Water Chemicals in your system. You need to Stop any Corrosion in Your System. by doing this You add life to Your System. Most People that installs these Systems don't care because it's not their system.

  • @aredee3814
    @aredee3814 2 ปีที่แล้ว +1

    Craig very good overview and explanation of each component. Have you ever used taco radiant mixing blocks (rmb-1) it simplifies the install through one unit.

  • @Danny-fs1hk
    @Danny-fs1hk 2 ปีที่แล้ว

    Damn, you’re an excellent teacher. Thank you!

  • @macpatel7810
    @macpatel7810 2 ปีที่แล้ว

    Fantastic detailed video. Very well explained.

  • @michaelmonaghan2717
    @michaelmonaghan2717 2 ปีที่แล้ว +3

    I love your videos and your knowledge! Best instructor on youtube,bar none! I am not looking to criticize or "catch" you in a mistake. But I thought you could not use galvanized pipe for gas pipes. Honest question!
    Also, you said the manifold underneath "mixes", I don't understand. How does the water not mix to one temperature if it is blended in the manifold? You've taught me a lot, just need some clarity on this.

    • @moeselec
      @moeselec 2 ปีที่แล้ว +1

      Hi Michael, you are right. AC Service Tec LLC is one of the best instructive channels.
      I watched and learned a lot from it. 😊👍.

    • @jkbrown5496
      @jkbrown5496 2 ปีที่แล้ว +3

      Magic. Well, it seems like magic as I'm just reading up on this. That is the "point of no pressure change" because between the supply and the return is where the expansion tank connects. The circulators can't create a pressure differential at that point. As there can't be a pressure difference between the supply side and the return side of the manifold, flow doesn't happen, but thermal transfer can occur to warm the return water so it is at the proper temperature for the boiler's efficient operation. You have to keep in mind the entire system is filled with water. The circulators just create a pressure differential from their input to output which causes the water in the system to move to compensate.
      I'm well past my understanding. I recommend looking at the books or talks of Dan Holohan, of the Heating Help website.

    • @waynecostanza2280
      @waynecostanza2280 2 ปีที่แล้ว +3

      It creates hydraulic separation. It allows the boiler which has a relatively restrictive hydraulic path to circulate and keep the return water from getting to cold to prevent shock to the boiler. The secondary loop where all the circulators are will be free to flow as much as the header pipe size will allow without the restriction of the boiler.

    • @boby115
      @boby115 2 ปีที่แล้ว +5

      Michael, the national gas fuel code NFPA 54 does allow the use of galvanized pipe for gas fuel runs. Back in the days when gas was manufactured from coal (coal gasification, before the late 1950s) galvanized pipe was prohibited because of possible flaking but now with better galvanized Processing /Manufacturing & clean dry natural gas the problem of flaking has been eliminated. That being said it is still prohibited for use underground ( it will corrode underground and quite rapidly, especially without cathodic protection). There is still municipal codes that prohibit the use of galvanized pipe for fuel run purposes and I feel this is because they are uneducated about current manufacturer processing and the cleaner natural gas used today. I do worry about fuel run materials currently used if the Gas Utilities start switching over to some type of hydrogen fuel or fuel mixture but that probably won't happen for quite some time and at my age I'm sure I will be long gone.👍🛠

    • @moeselec
      @moeselec 2 ปีที่แล้ว +2

      Thanks for your input.

  • @wjb-lc5hl
    @wjb-lc5hl ปีที่แล้ว

    That’s why I love this trade I learned as much from the comments as I did the video. Great job Craig you and Steve Lav keeping me sharp. I had to smile at the hot water heater expansion tank sitting on the five gallon bucket(temporarily until it’s properly secured of course). When can we expect the boiler book? Thanks again

    • @truthbebold4009
      @truthbebold4009 ปีที่แล้ว

      So these boiler set ups are normally done by plumbers or HVAC? I'm looking at getting into residential HVAC service technician. Thanks

    • @wjb-lc5hl
      @wjb-lc5hl ปีที่แล้ว

      @@truthbebold4009 Plumbers usually do the installs and mechanical repairs, but a good Hvac tech understands the overall function and every components operation. For example an hvac tech knows how to troubleshoot a boiler and find the circuit is being interrupted by a faulty low water cut off. Hope that helps good luck stay safe.

  • @rickolson9011
    @rickolson9011 2 ปีที่แล้ว

    Very clean! Very thorough!

  • @bravoactual2423
    @bravoactual2423 2 ปีที่แล้ว +1

    Awesome. Thanks a ton for sharing this!!!

  • @mariusm3595
    @mariusm3595 2 ปีที่แล้ว +2

    Love 5 gal bucket under expansion tank hehhee

  • @johnjohn-ne8fw
    @johnjohn-ne8fw หลายเดือนก่อน

    Master Class 🏆

  • @jkbrown5496
    @jkbrown5496 2 ปีที่แล้ว

    Some have commented on the LWCO. It looks to me to be at the level of the boiler circulator, above the boiler manifold. As such, the boiler should sense whether there is water flow from the circulator, and depending on the pressure differential between the larger distribution manifold pipes and the boiler supply-return piping from the boiler manifold, the level in the boiler might remain sufficient with the boiler just cycling through the manifold since there would be no system pressure from the expansion tank once the system was open to atmosphere.

  • @ArchinatorWC88
    @ArchinatorWC88 ปีที่แล้ว

    Got it....I'll just stick to changing angle stops

  • @markchocolas4236
    @markchocolas4236 2 ปีที่แล้ว +1

    Great video, very informative, but I have a question. What are all the low voltage transformers for? The zone board should be supplying the thermostats with 24 volts, correct?

  • @coreinfrank1468
    @coreinfrank1468 2 ปีที่แล้ว +1

    Great explanation , thank you so much

  • @stanli8069
    @stanli8069 หลายเดือนก่อน

    really throrough, i am a layman and i can understand what you are talking about

  • @noelj62
    @noelj62 2 ปีที่แล้ว

    Very detailed infos. Great video.
    Thank you

  • @cadealexander360
    @cadealexander360 2 หลายเดือนก่อน

    Thank you for helping me. cheers

  • @christopherbaier4847
    @christopherbaier4847 2 ปีที่แล้ว

    Nice presentation
    Thanks for the information
    Nice work when you get it

  • @lukehodgson5222
    @lukehodgson5222 2 ปีที่แล้ว

    Thx for the informative video! I have boiler heat in my home so I've been trying to learn as much as I can. One question, how do you tell if you're automatic air bleed is working? I hear gurgling, mainly in my bedroom. I have tried to manually bleed air at the floor radiator without much success.

  • @flexiblefix-montreal1167
    @flexiblefix-montreal1167 2 ปีที่แล้ว +1

    Pure gold!!!

  • @jhonatanoyarce4488
    @jhonatanoyarce4488 2 ปีที่แล้ว

    great video, i've learned so much from this!

  • @mattrempel4369
    @mattrempel4369 ปีที่แล้ว

    I like your videos but i think you missed out on a few learning opportunities here. I noticed several errors in installation. LWCO needs to be above the boiler, fill system should be installed at the point of no pressure change, header actuators should not be installed pointing down (that is my preference for longevity, consult manual for specific installs), recirc pump is improperly mounted motor needs to be horizontal…. Any others i missed?

  • @KINGPAFA
    @KINGPAFA 2 ปีที่แล้ว +4

    Also missing a valve on top of air scoop in case if we need to change the bleeder!

    • @waynecostanza2280
      @waynecostanza2280 2 ปีที่แล้ว

      Look close, they have a check valve installed, when you u screw the air vent the valve will seal like a schrader.

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว

      @@waynecostanza2280 those check valves are junk and will blow apart showering you in burning hot boiler water, how? they blow apart when the o-ring fails. the single o-ring on the moving valve core part is what seals when you remove the air vent, that same o-ring also holds the whole valve core in place when it's closed(air vent removed).
      I've had five of them pop apart already, age ranging 1 to 6 years old from install, luckily I always isolate and relieve the pressure and yes they all popped apart with nearly zero pressure. even at no pressure a wide open dumps lots of water fast and if your working on it hot it's very ugly.

    • @waynecostanza2280
      @waynecostanza2280 2 ปีที่แล้ว

      Good to know!