Rs.50,000 BUDGET 1KW SOLAR PANEL WITHOUT SOLAR INVERTER - OFF Grid Solar Power System in Tamil
ฝัง
- เผยแพร่เมื่อ 14 ก.ค. 2022
- Under Rs.50,000 budget you can build your own 1KW solar panels without Solar inverter.
Yes it is possible to install your solar panel on your existing Home inverter and battery. No solar inverter and no more additional cost involved very effective way .
Iam creating series of Solar energy related topics with easy and practical way to build solar power plant.
My solar Episode links
Part1 : • My 30,000 rupees solar...
Part2 : • Single 12V Battery Sol...
Part3: • Solar Plant உங்களுக்கு...
Part4 : • 1KW Offgrid Solar Syst...
You can mail me for any clarification
Mail me : myevreview@gmail.com
Telegram group :
#solar #solarelectricity #loomsolar #waaree #solarelectricity
Consider Subscribe and if you like the video click like button .Share it to all your friends and relatives. - ยานยนต์และพาหนะ
அருமையான காணொளி
நல்ல தொறு முயற்சி
நண்பரும் தன் வீட்டிலுள்ள சோலார் செட்டப்பை வீடியோ விளக்கங்களும் புரியும்படி எடுத்து அனுப்பியதற்கு நன்றி மற்றும் வாழ்த்துகள்
இது போன்று சுயசார்புக்கு மாறி அனைவரையும் ஊக்குவிக்க வேண்டும்
உங்கள் அனைத்து காணொளிகளும் வரவேற்பை பெறுகின்றன
நன்றி சகோ 🙏🙏
Good informative, you have any idea EXIDE C10 battery bulk / float voltage can set in MPPT
My solar Episode links - Should watch
Part1 : th-cam.com/video/0v0haaoCEG4/w-d-xo.html
Part2 : th-cam.com/video/yI1H4rAEGok/w-d-xo.html
Part3: th-cam.com/video/aF3IX-SDRVA/w-d-xo.html
Part4 :th-cam.com/video/0YhIHWt-jHw/w-d-xo.html
Part5: th-cam.com/video/0Sm2-cnnPzw/w-d-xo.html
Nice sir good information
வாழ்த்துக்கள் சகோ வேற லெவல் வீடியோ நன்றி
நன்றி சகோ 🙏👍
congratulations sir
Super sir valthukel
Super nanba
If 24v system....2nos 220ah batt.....one 445w mono perc half cut panel will take how long to charge it ? Dealer says 450w is enough to feed 2 such batts and charge them from 30% DOD to full in one day. Is this true ?
Super sar
Bro daily 1000unit current kidikuma scrubber machine daily 8 hours use pannura mathiri current bill yae 8 hours ku 800 aagum mam
30 a Changer controlr 750 Watts panel continue propulam varuma
battery illama panna mudiyuma? Can we reduce cost even more by reducing battery? Day time mattum use panrathukku.
Super ji
keep watching and keep supporting. More interesting Solar related content on the way.
Super
Good
இந்த வீடியோவில் காணப்பட்ட சோலார் பேனல் ஸ்டாண்ட் ரெடிமேடாக வாங்கினதா அல்லது, customise ஆக செய்யப்பட்டதா?
How to do this in apartment ??
Great video and I thank you very much for this but I have a question in my farm there is no grid supply or government provide electricity can I use this inverter without mains and run small house?
Yes you can use off-grid solar panels with battery to run your farm.no electricity needed.
Wari 550w pannel price please
Unga shop which district
I am ravikumar,we are into solar in Chennai
Ok bro. Good to hear from you.
Hi Sir, How to setup solar for 4 led tube light and 2 fans. so we need it for minimum 14 hours of power from solar actually we dont have eb connection. Please advice
You can have 540watts single panel with 2x12volt c10 battery system.
@@DiwakarRajanOnline is it 150ah battery? And which brand is preferred?
Excide inverter 1050 va 165Ah -2 battery inverter supply painnuma bro inverter la display painnu irkka 120Ah-2
Bro i didn't understand you exact question.
Panel life plz, sir
Brother ubs use pandr vitu old battery death new battery evola pota nalla eruka
For solar use go for Exide 150AH C10 battery
Hi sir
I am having 2 Exide IT 500 batteries and the inverter is also Exide 24 V 1450 va inverter.I am planning to install 3 nos of 445 watts mono perc half cut solar panel with smarten 50 Amps MPPT charge controller.will smarten Mppt 12/24 support this setup?
For the above configuration should I install 2 panel or 3 panels of 445 mono perc?.Pl.suggest.
Bro for your setup you can use maximum 3panels. check the load carrying capacity for smarten at 24v system.
All mppt controller support 12and 24v
U connect panel in parallel connection
30 ams varum better u go for smarten 50a controller
Unga battery 150 ah*2 so toatl 300 ah so total 3600 watts. Mono or poly any panel 445 or 450 3 panels ah parallel panunga like 33 ams varum .50ams charge controller la kudunga smarten or any other brand ok. But compulsory parallel connectors potu nala tight ah crimp pani kudunga dc cable 6sqmm use panunga because ams heavy soo..
3 hoursla battery full aidum
@@vidhyasahara2078 Thank you bro
@@SenthilUHD welcome bro
Compulsory parralel 3 in 1 connector podunga 6sqmm dc cable podunga.. Wirela join podathinga heat agum fire kuda agum
Pls post video reg ev two wheelers charging pin in india
Ok bro
Bro உங்க video va புரிந்து கொள்ள வேண்டும் என்றால் EEE ல மாஸ்டர் panna மட்டும் தான் தெரியும், சதாரண மக்கள் புரிந்து கொள்ளும் வகையில் எத்தனை Fan, லைட் யூஸ் பண்ண முடியும் என்று மட்டுமே கூறி Video போடுங்க must tell the solar panels and inverter with battery price
🤝👍
நண்பரே இந்த MPPT charge controller எப்படி செட்டிங் செய்வது.
குறிப்பாக இரவில்( பேனலில் இருந்து DC volt வரதபோது) வீட்டு AC mpptவழியாக இன்வெர்ட்டர்க்கு செல்லும்போது பேட்டரி full ஆகி Battery too high என mppt வருகிறது. பேட்டரியும் ஹீட் ஆகிறது.இது எதனால்.
Bro, inverter la low amp charging set panikonga so evening time battery full agathu, grid charging off option irutha atha disable panikoga evening time battery charge agathu only grid mulamah appliances run agum .
Bro I have 150ah battery and 800va Invertor
I want to update with that battery as solar can we use
Yes you can do that like me. Retro model off-grid system. All you need is mppt controller with sufficient amps.
@@DiwakarRajanOnline can we run refgirator and mixer on that
hi sir, i need a Wind turbine + solar pv On-grid Hybrid inverter system . is it available in chennai or in India.... ? Solar People are saying , we can connect wind energy input and solar input in any hybrid inverter that has 2 MPPT controllers. Is that true sir....?
Wind turbine model not a successful model in chennai. Also it is costlier than solar panel implementation. Instead you can have battery souce for night time and charge it using morning hours.
@@DiwakarRajanOnline its for my farm house situated at Bodi foothills sir. Malai adivaram, so there is a constant wind speed of 10-18kmph.
is it not hybrid ? Why we need to switch off the EB ?
He show us it is off-grid which works without EB. Mppt itself take control of when to make eb available and when to switch off depend on solar power.
57 thousand for 1 kw panels, inverter,2 nos 12 volt battery,how is it possible
Battery 1 no with 12 volt is costing minimum 15 k so 30 k battery alone to 1 kw ( 3 x335 w panels) 45 k minimum
Inverter sine wave around 12 k
Without cables and installation exp
It is adding to 87 k.
Cable and installation wil be another 12 k minimum so 1 lakh.
Every 3 to 4 years you have to change battery now 30 k.
Instead you can go for good on grid set up fir day time power 2 kw will be mak 1.5 lakh no recruiting expense.
Only net metre you have to buy.
Your roi is 6 years Max from 7 th year system is free until 25 th year
Partially you are right here in my off grid setup i didn't purchase inverter and battery. I used my existing inverter and battery which lower my over all cost. Since it is 12v system iam going to maintain same amount of cost for battery after 6years. Ongrid grid system still costly and government planning for subsidy in that case people who install this year may get subsidy.
Hi sir
Hi Sir, is it possible to install ongrid & offgrid together ? why i am asking this question is.... say for example if we are not getting EB current more than a day due to natural calamity or any other reason then can we convert/repurpose ongrid system to offgrid with minimal manual intervention ? how much it will cost ?can you please make a video for it ?
Yes bro we can install both off-grid and ongrid together.
Contact number
😊
Bro solar pannel la ac 24 hours work aguma bro please explain
Yes bro work aagum.
Can we charge Ather scooter with 1kw home inverter ?
Try it and see.
Brother can you guide me actually my friend doing business (idly mavvu) he using big grinder for commercial purpose
For two months around 600 units coming. He want to reduce current bill
I said why not going for solar panel. But I also don't have clear idea for that possible. Also if we are going solar how much over cost it will take. We are in trichy. Can you pls guide us how much cost we have to invest and it will be ok normal connection.
Go for Ongrid system with minimum 2kw panel capacity. Check with nearest dealer and get quotation. Go for polypanels which will bring down the cost.
Thanks brother for your guidance.
1hp submotor use பண்ணலாமா 24vor12v?
It is not about voltage your inverter should support High watts motor.
Sir I have 250×2 poly panel, 200 ah battery, old inverter.
For upgrade can I go for ashapower mppt inverter nova50, exide c10 150ah battery, and 250×2 mono panels so that I can use about 750 watts from solar, if u give ur contact I can talk to U
You can use 500watts as per your panel. design vise it will work with old inverter.
@@DiwakarRajanOnline shall I buy ashapower nova 50 and non perc 250×2 panels
I have 250 watt two panels poly,
If I want to add 335 watt panel can I go for mono crystal panels
Sir 750watts solar panel ku ena solar charge controller use panalam sir?
It depends on which Voltage system you are using.
@@DiwakarRajanOnline 12 v
Go for asha mppt controller.
@@DiwakarRajanOnline ok thankyou 😊👍
Only c10 battery
Can u install
I can help to get install .
சொல்ற விஷயத்தே டக்குன்னு சொல்லுங்க புரோ
Ungala eppadi contact panradhu
Email பன்னுங்க. myevreview@gmail.com
Ongrid 5kw price
Mail me your requirements and phone number.
1 kw 50k vaa is it true
Yes our subscriber solar plant. Watch it completely
Bad investment. I invested in two installations of 1 KW each. initially they were sukam. company went out of business and the product had issues. Replaced with hykon. Biggest cost was batteries. Two of my batteries blew up from overcharge issues. Now I disconnected the solar setup since the batteries had to be constantly topped up leading to safety issues with acid. Replacement cost for 4 lead acid batteries is about 50,000. Not worth it. Netmetering might be better - but the TN govt cannot be trusted for long term payments. In future we might have LiPo batteries that can be used both for scooter and UPS - that might be a better option...
Bro for off-grid solar setup use Exide solar battery. Which will last for at least 2 to 3years
@@DiwakarRajanOnline my tall tubulars lasted about 3-4 years. But the problem is that I have to redo the entire battery investment every 3 years. Also, i need to refill battery liquid every 4-6 months. That is a headache because it is risky as there is acid involved, and there was a bit of shock if you touch any terminals by mistake. Not ideal for domestic users. EB also has problems during rainy season - a few times they sent 440V due to their problem !!! This causes issues with the inverter. Even without such EB issues, the inverter develops problems after 3 years - which is why most of these companies only give 2-3 years warranty for inverter.
I spent 5Lakhs on two installations - complete waste.
I would not recommend Lead Acid batteries. I prefer LifePO batteries that last 10 years, with many more recharche cycles - and safer too. But the price is still too high for such batteries. But because of growth in EV segment, I think such LifePO battery cost will come down in 1-2 years. So I would recommend waiting for 2 years.
சரி சோலார்ல போட்டரி ஃபுல்லா சார்ஜ் ஆன பின்பு, லோட் நம்ம பயன்படுத்தாத போது என்ன ஆகும்,
ஏன்னா சோலார் இன்னும் சப்ளை உற்பத்தி பன்னிகிட்டே இருக்குமே?
Mppt controller Solar productionஐ நிறுத்திவிடும்.
Solar production will continue. But, mppt will not allow. Yes, solar power produced will get wasted. So, plan carefully
@@damu2000 yes why we have to waste the solar production,
If we switch into ongrid system, unused power will send it to grid,
100% we can utilise the energy.
But this system only works when the grid supply is present.
ஒரு விண்ணப்பம் முதலில் சில புரிதல் இல்லாமல் இருக்கு எங்களை போன்ற தொழில் நுட்பம் தெரியாதவர்களுக்கு அதனால அடிப்படை கற்று கொடுங்க உதாரணம் ஆப் கிரிட் ஆன் க்ரிட் என்றால் என்ன கிலோவாட் அம்ப்ஸ் இது போன்ற அடிப்படை விஷயத்தை சொல்லி பிறகு மாற்றத்தை சொன்னால் தெளிவா இருக்கும் நன்றி
இப்படி சோலார் பேனல மாடியிலும், சார்ஜ் கண்ட்ரோல கீழேயும் வச்சா, பேனல் இருந்து வரும் டிசி வோல்டேஜ் டிராப் ஆகாதா.
செய்யலாம் என்றால் எத்தனை மீட்டர் தூரத்திற்க்கு எத்தனை வோல்ட் டிராப் ஆகும்?
அவர் வைத்த அந்த சிஸ்டதில் எவ்வளவு யூனிட் மிச்சம் ஆச்சு?
எதாவது தெரியுமா
DC wiring should not exceed 20 meters distance.
Good morning pls give me contact sir I'm in Chennai
Pleas email me myevreview@gmail.com