Shed Electrical Installation (How to Add Electricity to a Shed - DIY)

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 พ.ย. 2024

ความคิดเห็น • 714

  • @kpd3308
    @kpd3308 ปีที่แล้ว +221

    Always run at least two cables to your shed, and dedicate one to your lights. If you're working at night, using a power tool, and it trips the breaker, you won't be left in the dark with a spinning saw blade, or whatever. I suggest 15 amp for the lights, and 20 amp for your power tools.

    • @Sparkeycarp
      @Sparkeycarp ปีที่แล้ว +17

      Great point. Plus I don't like running Romex in conduit. Could have made an easy pull with just a couple hots, a neutral and ground. Use a two pole breaker if you do. Good luck ever pulling the Romex out of that conduit.

    • @houseman2414
      @houseman2414 ปีที่แล้ว +11

      It's a code violation to run two diffetent feeders to an outbuilding like that (unless you have special circumstances like a switch at the other end controlling an outdoor light, different power source, etc.). You generally get one feeder, although a multi wire circuit still counts as one. So, you could do a pair of 20 amp circuits to a shed on a shared neutral in a single 10/3 (or 12/3 if close).

    • @pld8993
      @pld8993 ปีที่แล้ว +8

      @@houseman2414 That's not a feeder, it's a branch circuit.

    • @artemkalinchuk
      @artemkalinchuk ปีที่แล้ว +32

      Run 240v cable and add subpanel in shed.

    • @godwin3265
      @godwin3265 ปีที่แล้ว +1

      you're actually running 3 or 4... at least in the us.. then setting up a subpanel and putting in different breakers for the lights than the outlets/tools... theres no issue here...

  • @johnstancliff7328
    @johnstancliff7328 ปีที่แล้ว +27

    I had a 50 Amp feed done years ago and I'm so glad I did.... it has both electric heat (5KW) and AC.... and its only a 12 X 8! but I love it!

  • @betta3301
    @betta3301 ปีที่แล้ว +42

    pro tip: take a couple photos of the full length of buried conduit before you backfill it for future reference (or make a sketch with annotated specifications.) locator services for underground utilities never mark DIYers' buried stuff.

    • @Mike_H76
      @Mike_H76 ปีที่แล้ว +2

      Even some utilities, like cable, do some "shady stuff"... they did a fix here a few years ago and literally ran their splice about 3 inches under the soil... I took a pic since I have to edge that bed every year. We also get frost heave here, so there are a couple other spots where the cable tv coax migrated and is literally laying on the ground, thanks to grass growing thatch, no issue in the lawn, only in beds and that gets mulched over. Granted, there's no safety risk.

    • @allenemiesforeignanddomest3320
      @allenemiesforeignanddomest3320 ปีที่แล้ว +6

      Tracer ribbon is always a good idea too.

  • @rosewoodsteel6656
    @rosewoodsteel6656 11 หลายเดือนก่อน +19

    Thanks for the video! You did a wonderful job building that shed and you gave us a lot of ideas on how to run electric to our sheds. My advice to those interested in doing their own electric would be to watch a lot of videos on this subject and read all of the associated comments. You will find a wealth of knowledge in the comment section and get an idea of what Andrew did right and where Andrew could have improved on his installation. To those who are critical of his work, I suggest that you help the rest of us by putting out your own videos on this subject. Thanks again for the work you put into this, Andrew. We all can learn from our mistakes, but we can never learn without attempting to try our hand at it.

    • @FranciscoGonzalez-ro7ht
      @FranciscoGonzalez-ro7ht 2 หลายเดือนก่อน

      You're absolutely right, good point Rose.

    • @DavePerry-h5r
      @DavePerry-h5r หลายเดือนก่อน

      There are different ways of achieving a proper install, as long as they all adhere to the code. The code is a minimum.
      A lot of what he did here is not up to any code I'm aware of.
      The reason the code exists is to prevent people from being electrocuted and fires. The code reads like a legal document and much of it resulted from previous fires and electrocutions.
      You can't guess when it comes to electrical work. With plumbing the worst thing that will happen is a leak, but with electrical the worst thing is a fire in the middle of the night when you're asleep or someone getting fried.

  • @portaadonai
    @portaadonai ปีที่แล้ว +47

    ProTip- always add a spare conduit, you can use this for low volt, telecomm, or if the other conduit fails, you can use the second one, you wont easily get another chance to trench later on.
    CodeTip- Most circuits are required to be 18 inches down in pvc, not 12 inches. Thats only an exception for GFCI protected wiring
    ProTip- Its very for the GFCI to nuissance trip in years to come, because water ALWAYS gets into the conduit, if the wire gets damaged at some point, you will lose power without the GFCI. You dont want to be chained to a GFCI for power, they are not reliable long term
    Look up the 'NEC burial depth chart' and make sure its from the last few years to be certain
    [also your not supposed to use romex in outdoor conduit, but as long as it doesnt go underground, its not a huge deal]

    • @ShaunPaget
      @ShaunPaget 4 หลายเดือนก่อน +1

      18" deep? ipvc is 24" by NEC RMC is 18"

    • @DavePerry-h5r
      @DavePerry-h5r หลายเดือนก่อน

      What do you mean by "chained to a gfci"? That gfci is designed to trip very easily so you don't get electrocuted. Its there for a reason. You take that out and replace it with something else and you're removing an essential safety device.

    • @DavePerry-h5r
      @DavePerry-h5r หลายเดือนก่อน

      Canada has a different code, but it depends on if the burial site has vehicle traffic over it.

  • @barryomahony4983
    @barryomahony4983 ปีที่แล้ว +64

    @6:10 No, if you're going to use non-metallic sheathed cable in underground conduit for some reason, it must be type UF. The interior of conduit outside or underground is considered a wet location (they always end up with some water in them). But it makes no sense to run UF in conduit; it's expensive and a pain to work with. Cheaper and easier to run individual 12 gauge THWN wires. Also, you cannot run the wires/cables as you go. NEC 300.18(A) says the conduit must be installed as a complete run before running any conductors. This helps ensure you don't have too many bends and/or the conduit isn't too small.

    • @usmc6153
      @usmc6153 ปีที่แล้ว +20

      I was actually dinged on an inspection for using sheathed cable in conduit. I was told it would not disperse heat properly.

    • @barryomahony4983
      @barryomahony4983 ปีที่แล้ว +7

      @@usmc6153 Yea you here that sometimes and it's not true. Sheathed cable is installed in exterior walls buried in inches of insulation without problem. Its conductors are massively derated; they use 90 degrees C insulated conductors, but the ampacity of the cable is calculated using the 60 degrees C column. In some limited situations Code even requires it in conduit to protect from physical damage (334.15(B)).

    • @Bryankrall8090
      @Bryankrall8090 ปีที่แล้ว +9

      You cannot use NMC in conduit per code. Have I done it in a residential situation, yes, usually to protect the cable from damage. if I was running this, I would use 1-inch pipe and pull conductors to give you options later. put for a DIY installed, this will last forever with no issues.

    • @barryomahony4983
      @barryomahony4983 ปีที่แล้ว

      @@Bryankrall8090 Where does it say that in Code? I don't see anything about it in 334.12. I know flexible cords can't per 400.12(6), but I can't find anything similar for NM. It's a dumb thing to do bur I don't see any prohibition for it.

    • @mikelawler2278
      @mikelawler2278 ปีที่แล้ว +1

      @@barryomahony4983 NEC 300.18(A) "Exception: Short sections of raceways used to contain conductors or cable assemblies for protection from physical damage shall not be required to be installed complete between outlet, junction, or splicing points."

  • @TheTidalwaveDave122
    @TheTidalwaveDave122 ปีที่แล้ว +18

    Very informative and well explained! The comments and tips by the other viewers was very helpful as well! Thanks to all!

  • @jasonbodenheimer4017
    @jasonbodenheimer4017 7 หลายเดือนก่อน +4

    Andrew, Love the easy to follow step by step. Regarding pulling the cable through the conduit, what I would offer as a tip: Since you performed the appropriate sweeping bends, this is super easy to pull romex through... Fully glue and bury your conduit... Option A: pull mule tape or 1/4" nylon rope through the conduit as you go. Option B: fully assemble all the way to just before your junction boxes and using a vacuum, you can suck the mule tape through the full length by tying a large cotton ball to the end of your mule tape/nylon rope. once the rope is in the conduit, you can use conduit lube to pull your electrical through the fully buried line... and since it's buried, it won't budge.
    Knowing that you did this build completely by yourself, the way you did it is perfectly acceptable considering you only had a single pair of hands, but you can save yourself a decent chunk of time sucking mule tape, then pulling cable through lubed conduit. Cheers, great video!

  • @johnhooton3286
    @johnhooton3286 ปีที่แล้ว +11

    Depth of trench is from top of conduit to grade.

  • @incredable6211
    @incredable6211 ปีที่แล้ว +6

    Andrew, obviously you are a great DIYer, but an electrician you are not and don't appear to know NEC code. Instructing others how to install something governed by codes and not being trained, it's just not a good plan.
    For those wanting to meet the NEC requirements: the code requires a disconnect means for separate buildings. a gfic recept is not usually rated as a disconnect for a separate building (just a switch where you put the gfic recept would do. A heat gun making those 90's not so sharp would help.
    A bushing is required where the romex enters the conduit. UF cable in pvc is overkill, it just makes it needlessly difficult to install and strip it at a small pvc box. Your shed is gorgeous, looks great.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน +1

      Technically this is a branch CCT not bigger than 20A, so not technically feeder, so shouldn't need a disconnect/ ground rod. no?

  • @microcolonel
    @microcolonel ปีที่แล้ว +15

    Buried conduit is considered a wet environment in code, so that UF-B was mandatory once you were in the buried conduit.
    Honestly seems like you might as well have started with UF-B. NEC does not demand 24" in all circumstances, that is the deepest general recommendation.
    One way you could have done this is to put a GFCI or dual function breaker at the panel, and run UF-B right from the main panel to your shed branch circuit.

  • @ScottsSynthStuff
    @ScottsSynthStuff ปีที่แล้ว +53

    Huge rookie mistake at 9:18. NEVER fasten two wires onto a single terminal on a switch or receptacle! Always join them to a third, single wire using a wire connector, then wrap that single wire around the terminal. You espouse doing things to code, but that double-wrapped wire will fail code inspections pretty much everywhere.

    • @Boobtube.
      @Boobtube. ปีที่แล้ว +3

      i saw that also

    • @smast16
      @smast16 ปีที่แล้ว +12

      I came to say the same thing. Two grounds on a single ground terminal is a no-go. He needs to go back and pigtail it or one of those fancy ground pass through.

    • @bigtroll8249
      @bigtroll8249 ปีที่แล้ว +3

      Gotta use a pigtail

    • @justind4763
      @justind4763 ปีที่แล้ว +3

      Yeah, I'm no electrician but I've done light electrical work and this part let me know the creator might not know what he's doing.

  • @tonywagner4836
    @tonywagner4836 ปีที่แล้ว +164

    Conduits are considered a wet environment by code so romex is a no no.

    • @pld8993
      @pld8993 ปีที่แล้ว +23

      The inside of conduits outdoors or underground are considered wet locations, like the one under the deck in this video; in dry locations they are considered dry locations.

    • @luvdady
      @luvdady ปีที่แล้ว +6

      Yeah I imagine that its a better idea to go to the foundation with Romex than a junction box , then go thhn to a larger level size than you think you'll need now (within reason 😉) as the price between 14 and 10 is a matter of a few bucks and having to buy 14 ft now and fishing vs buying 10awg and fishing is not so cheap...

    • @OrdinaryDude67
      @OrdinaryDude67 ปีที่แล้ว +6

      @@pld8993 that’s a good point. Conduit isn’t a wet location by default, it depends where it’s installed.

    • @bobniles1928
      @bobniles1928 ปีที่แล้ว +22

      @@OrdinaryDude67 Any conduit outside or underground is a wet location.

    • @OrdinaryDude67
      @OrdinaryDude67 ปีที่แล้ว +5

      @@bobniles1928 mostly correct, and conduit installed indoors is a dry location.

  • @danielmalack3714
    @danielmalack3714 ปีที่แล้ว +4

    #2 Conduit has to be built then wire pulled! The glue will melt the sheathing on the cable. you will nick the cable doing it that way and it will be compromised. All conduits underground will have water in them no matter how much glue you put on the conduit, If you nicked the wire (which you did) is compromised.

  • @josephknapick5307
    @josephknapick5307 2 ปีที่แล้ว +18

    I believe the round boxes for the spotlights must be flush with the OUTSIDE SURFACE of your sheathing...

  • @dfj555
    @dfj555 ปีที่แล้ว +11

    Should have used a sub panel at the shed and ran a thicker wire, like a 6 for future upgrades, AC/Heat, outlets, lights, etc.

  • @monteporche5552
    @monteporche5552 ปีที่แล้ว +24

    One other little thing. You're not allowed to have more than 360 degrees worth of bends between pull points in your conduit. You have two 90's right at the bottom of the house, one 90 a few feet away, what looks like a 45 right before the shed, and then a 90 going up. That's 405 degrees total.

    • @sarimjk
      @sarimjk 11 หลายเดือนก่อน

      Why is that?

    • @monteporche5552
      @monteporche5552 11 หลายเดือนก่อน +2

      @@sarimjk I would assume its because each turn adds to the difficulty in pulling the cable through.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      Because he was supposed to build the entire pipe before pulling through with a fish wire/tape, which would be next to impossible with more than 360 degrees. I doubt anyone would even be able to pull it out without digging up the pipe.@@sarimjk

  • @quicksilver462
    @quicksilver462 ปีที่แล้ว +6

    I bought a house in 2000, it had the water well in the front yard, about 50 feet from the street, and the pump and tank was also located there. The house sat about 300 feet further back from the street, and to power the water pump, the previous owner had romex suspended from the oak trees running all the way back to the house, entering the front living room through a hole in the floor, with the romex connecting to a lamp corp with wire nuts, then inserted into the electrical outlet in the wall of the living room! ...face palm/shakes head/ rolles eyes!! I installed UFC down about 3' (ditchwitch) and a proper 20A breaker in the electrical box. Took be a whole weekend to do...oaktree roots!

    • @allenemiesforeignanddomest3320
      @allenemiesforeignanddomest3320 ปีที่แล้ว +1

      And that’s why you should always hire an inspector before you close.

    • @quicksilver462
      @quicksilver462 ปีที่แล้ว +4

      @@allenemiesforeignanddomest3320 I really don't need to hire someone to tell me something I already know!

    • @TheRaker1000
      @TheRaker1000 ปีที่แล้ว +2

      when i bought my house, the well had a harbor freight sump pump sitting in the well pit with a garden hose run down the hole to the water... and it was powered by an extension cord with the plug cut off and stuck into a breaker in the electric panel.

  • @fldave612
    @fldave612 ปีที่แล้ว +6

    I'm actually surprised your electrician didn't put in a GFCI breaker in the panel knowing that everything that circuit will feed is outside, in fact I believe the NEC mandates that GFCI protection must begin at or before the transition point from interior to exterior in a branch circuit. That 20 amp single circuit feeding your shed is kind of small, that only leaves enough power for lights and a few small power tools like a circular saw or jig saw. I would have ran an 80 or 100 amp feed to the shed and put a small sub panel out there and branched everything off of that, but I also have a drill press, 60 gallon compressor, a 2 HP table saw, and a 5000 btu window A/C in my shed/shop which is much more than most homeowners normally have.

    • @rmcdaniel423
      @rmcdaniel423 11 หลายเดือนก่อน +1

      He's using it to store a lawn mower and shovels, etc. I seriously doubt he would ever need 100 amps out there. LOL

  • @theradonpros
    @theradonpros ปีที่แล้ว +1

    Hand unroll that coil of wire, to prevent twisting which led to piping difficulty. Great job!

  • @AC9T
    @AC9T 4 หลายเดือนก่อน +4

    YEs folks, always check with a local electrician to make sure you aren't engineering a code violations as code does in fact change and there may be considerations to where you live. As of today, prior to watching this video, I found another that specifies that NMC (non metallic/Romex etc.) can not be run inside ANY conduit once it transitions to a wet location...for example, if the conduit/pvc goes outside, your wires inside must be THHN and NOT even just stripped NMC/Romex!

  • @mcarroll598
    @mcarroll598 ปีที่แล้ว +72

    Non metallic sheath cable is not rated for wet locations. This is a code violation. If you would’ve ran UF cable (sleeved with PVC conduit) outside under the deck you would be good. And you should’ve used expansion fittings transitioning out of the ground to the structure. When the ground moves it expands and contracts, it will pull PVC apart.

    • @jamesstuart3700
      @jamesstuart3700 ปีที่แล้ว +4

      So run UF-B all the way?

    • @mcarroll598
      @mcarroll598 ปีที่แล้ว +9

      @@jamesstuart3700 yes or install conductors rated for wet and damp locations.

    • @chrispopp2713
      @chrispopp2713 ปีที่แล้ว

      Pvc is rated for underground and wet. Shut up.

    • @pld8993
      @pld8993 ปีที่แล้ว

      @@chrispopp2713 But NM in PVC is not rated for wet. Shut up.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      one could argue the deck is damp not wet, but best practice would also be to unsheath the entire run in conduit.

  • @christophereric1407
    @christophereric1407 5 หลายเดือนก่อน

    Helpful video. I’d run a underground spec data cable in a half inch PVC for a shed node to push a strong wifi signal out into the yard. With a clothesline string to upgrade or replace the data cable as necessary.

  • @XsoloXela1989
    @XsoloXela1989 หลายเดือนก่อน

    Thank you for the best, detailed diy video ive seen, and ive watched a lot 😂😂

  • @edgardodelvalle2769
    @edgardodelvalle2769 7 หลายเดือนก่อน +1

    For your information the number of curves you used is higher than the NEC code electric recommend.
    358.26 Bends - Number in One Run. “There shall not be more than the equivalent of four quarter bends (360 degrees total) between pull points, for example, conduit bodies and boxes.”

  • @dyson9422
    @dyson9422 10 หลายเดือนก่อน

    When I read the National Electric Code (NEC) the conduit had to be fully assembled before the wire was pulled through. If you plan on storing gas powered equipment in the shed then read the part of the code that explains when explosion proof fittings are needed. Generally the plan is developed and drawn so that with the aid of the drawing and parts list a permit can be issued. No permit means your home owners insurance may not pay if something goes wrong.

    • @pld8993
      @pld8993 9 หลายเดือนก่อน +1

      Yes, conduit is required to be completed before installing conductors but a residential shed is not a hazardous location requiring explosion-proof fittings.

  • @tr8970
    @tr8970 2 หลายเดือนก่อน

    After reading a fraction of the remarks I have decided to hire a licensed electrician to wire my shed. Andrew, my advice is to hire a licensed electrician; show him this video and have it brought up to code. Afterwards, sell the rights to this video to National Fire Protection Association (NFPA) which writes the NEC . They can use as a training video. Hopefully water doesn’t get into the tubing and cause a short, especially since you poured concrete.

  • @johngrafton6868
    @johngrafton6868 ปีที่แล้ว +28

    People like you is the reason we have a National Electrical code!

    • @I-sed-no
      @I-sed-no ปีที่แล้ว +12

      lol... says the electrician who didn't get paid for this job

    • @yeeyee2739
      @yeeyee2739 ปีที่แล้ว +3

      that non-metallic sheathed cable is swimming in water

    • @johndavies2949
      @johndavies2949 11 หลายเดือนก่อน

      Yes.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน +1

      I've seen a lot worse than this; some from licensed electricians. :{ He did a great job building the shed!

    • @mikei759
      @mikei759 10 หลายเดือนก่อน

      Ok cuck

  • @keithhupp5995
    @keithhupp5995 ปีที่แล้ว +4

    I just bought a house that has power going to the shed its a 20 amp breaker and they followed the same guidelines on the depth so I know now by watching this video that my shed is safe and the guys who did the work knew what they were doing. I enjoy watching the different videos of each project very educational. TY

  • @mhh102
    @mhh102 ปีที่แล้ว +1

    solid video and nice shed! i think im gonna forgo the gfci outlet with an all in one breaker tho. 1 less thing to worry about.

  • @robertpetit57
    @robertpetit57 2 วันที่ผ่านมา

    You are also in violation for having more than 360 ° of bend by 45 degrees. I would have used THWN in the PVC.
    ITS A GREAT looking shed, especially the slat wall and accessories!

  • @robertzeigler370
    @robertzeigler370 ปีที่แล้ว +2

    you must ground the circuit at a sub panel at a shed with a ground rod

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      if it's a feeder over 20A, not a branch cct.

  • @LawGPT
    @LawGPT ปีที่แล้ว +4

    Nice tutorial. Is it ok to join the PVC in place with the cable running through it? I thought that was verboten.

    • @shelms488
      @shelms488 ปีที่แล้ว +2

      You’re correct that is against code.

  • @wjohanw
    @wjohanw 5 หลายเดือนก่อน +2

    I'm fairly certain you aren't allowed to run romex outside in conduit. Outside (even in a trench) is considered a wet location. Might need to double check the NEC codebook.

    • @fizwin1
      @fizwin1 5 หลายเดือนก่อน

      this^ !!!! omg

  • @billdarling2629
    @billdarling2629 ปีที่แล้ว +11

    All of the electrical (blue) "boxes" (circular and rectangular) on the exterior walls of the shed should be mounted flush with the exterior wall. So, neither the box for the double switches or any of the boxes for the exterior lights comply with electrical codes. And they're all fire hazards and potential shock hazards. Other than that (and running the wrong type of wire out of the house), good video.

  • @douglasgreaves188
    @douglasgreaves188 ปีที่แล้ว +1

    UK electrician, we generally use an armoured cable for outdoor runs. Have a 600mm depth rule for none armoured. All our circuit's are gfci protected from panel. Conduit runs would require a number of access points.

  • @JAM-zb2vh
    @JAM-zb2vh 2 หลายเดือนก่อน

    Thats true it is hard to get the cable to make all them bends take your time and get it right to all DUI installers.

  • @glassblastcollision
    @glassblastcollision 9 หลายเดือนก่อน

    A good air compressor can assist in feeding the a rope by blowing air down the conduit the direction you push the cord. Then you can tie the cord to your wire and pull it through. It's good idea to pull another cord through if youd like to pull other curcuits like cable, internet or speaker wire.

  • @rickyseddon4786
    @rickyseddon4786 ปีที่แล้ว +1

    Wow in Australia our excavation deep is 1000mm or 3 and 1/3 feet 😅 you’re so lucky

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      in Canada we can drop a treated 2x4 on top and save a few inches of fill

  • @jesseperezonedeep
    @jesseperezonedeep 2 หลายเดือนก่อน

    Great job💯💯💯just what I was looking for for thanks

  • @Drew-C-
    @Drew-C- 7 หลายเดือนก่อน +4

    7:35 - Andrew: wipes off any extra pvc cement purely for ascetics
    Also Andrew: gets pvc cement on shed

    • @AndrewThronImprovements
      @AndrewThronImprovements  7 หลายเดือนก่อน +4

      Haha you'll find a lot of crap like that here.

    • @Drew-C-
      @Drew-C- 7 หลายเดือนก่อน +2

      @@AndrewThronImprovements Cheers bro, great video

  • @johnnydeutschemark3620
    @johnnydeutschemark3620 หลายเดือนก่อน

    Over long distances, from home service panel to a shed in the back yard, you will experience 'voltage drop' so plan accordingly, like using higher gauge wire #10 wire. BTW: What size breaker did you electrician put in your panel? This would be useful information.

  • @ramiygr.3629
    @ramiygr.3629 2 หลายเดือนก่อน

    This was very useful thank you

  • @ysidroavila6454
    @ysidroavila6454 7 หลายเดือนก่อน

    Good video, I think it's good if you make a follow up or edit this video to show and explain your mistakes and code infractions

  • @westhavenor9513
    @westhavenor9513 ปีที่แล้ว +5

    If I were to put Romex in buried conduit, I would only use UF-B cable. Conduit often ends up full of water in a few years, or less.

    • @Sparkeycarp
      @Sparkeycarp ปีที่แล้ว +3

      Don't put Romex in buried conduit.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน +1

      condensation from the air is enough to fill it eventually

  • @tomchristensen2914
    @tomchristensen2914 25 วันที่ผ่านมา

    I was told when running romex through conduit that if it was outside it was considered wet locations and had to be seperate thhn

  • @georgewadejr5474
    @georgewadejr5474 ปีที่แล้ว +2

    Good looking shed . 💰🤑🤠 I don't understand why there are so many 90° elbows . You only needed 2 90° elbows . Straighten the ditch out . 3/4 PVC is flexible . Wet locations use UF wire in conduit .

    • @pld8993
      @pld8993 ปีที่แล้ว

      UF doesn't need conduit in this installation, it's rated for direct burial.

    • @georgewadejr5474
      @georgewadejr5474 ปีที่แล้ว

      @@pld8993 no s*** Sherlock but stupid is as stupid does

    • @pld8993
      @pld8993 ปีที่แล้ว

      @@georgewadejr5474 Sherlock didn't say wet locations use UF wire in conduit, you did. First, no, UF goes right in the dirt, installing it in conduit is an amateur move. Second, UF is cable, not wire. So does that make you stupid is or stupid does?

    • @SeanFitz-vo4fm
      @SeanFitz-vo4fm 10 หลายเดือนก่อน

      An amateur move would be assuming the UF cable with no conduit protection will never get damaged by someone installing a fence post or a tree. It's totally professional to do it the quick, cheaper way and not worry about someone with a steel breaker bar getting shocked, because as a pro, you'll be off on another job and won't have to deal with it. @@pld8993

  • @njc7293
    @njc7293 2 ปีที่แล้ว +10

    PVC pipe must be a minimal of 18 inches. UF cable can be 12 in if GFI protected from the main panel.

    • @pld8993
      @pld8993 ปีที่แล้ว +5

      As long the circuit is residential, 120V and 15 or 20 amps, and GFCI protected, the conduit can be 12".

    • @michaelsrossi3293
      @michaelsrossi3293 ปีที่แล้ว +2

      code states PVC is 18” to top of conduit or cover Per NEC 300.5

    • @pld8993
      @pld8993 ปีที่แล้ว +4

      @@michaelsrossi3293 You're correct, it says that in Column 3, but Column 4 allows for 12" when installed according to the conditions listed.

    • @michaelsrossi3293
      @michaelsrossi3293 ปีที่แล้ว +2

      @@pld8993 right I didn’t read or watch long enough to see it was GFI protected knee jerk reaction to first comment

    • @pld8993
      @pld8993 ปีที่แล้ว +5

      @@michaelsrossi3293 That's one of the few things in this video that don't violate the NEC.

  • @tomdewey9690
    @tomdewey9690 ปีที่แล้ว +4

    That shed looks great. The electrical comments were very helpful. I see why you did it the way you did. My only comments are that i would have put the switches on the inside and used smart switches to set up timers and to be able to control them remotely.
    Do you have to use fire blocking rated caulk or spray foam for that penetration to your basement? I'm not sure when that applies.

    • @allenemiesforeignanddomest3320
      @allenemiesforeignanddomest3320 ปีที่แล้ว

      I believe fire rated caulk or foam is only required to seal penetrations between living spaces to prevent fire spreading from floor-to-floor or room-to-room. That’s what my builder relayed to me when I was running cat 6 in our house.

  • @danielnorton8090
    @danielnorton8090 9 หลายเดือนก่อน

    Can't wait to plug in my two headed 100watt light bulbs into my antique stand up lamp that I always have near my extra lightweight drapes

  • @danboone9674
    @danboone9674 8 หลายเดือนก่อน

    thanks great vid, I learn a lot, electricity is scary to me.

  • @babsk4071
    @babsk4071 8 หลายเดือนก่อน

    WHAT A SHED!☕️👍

  • @MatthewPierce9
    @MatthewPierce9 9 หลายเดือนก่อน +1

    Good video. I believe it is against code to run Romex through conduit. My understanding is that you must use THHN or similar. It's also my understanding that if conduit has >360* on bends there needs to be a junction box, not sure if you have that many or not. I counted 4 x 90* so that may be within the rule.

    • @pld8993
      @pld8993 8 หลายเดือนก่อน

      Romex is allowed, and sometimes required, in conduit.

    • @VishalRaoOnYouTube
      @VishalRaoOnYouTube 3 หลายเดือนก่อน

      THWN might be safer for water resistance

  • @MyGarageWoodshop
    @MyGarageWoodshop 3 หลายเดือนก่อน

    did you use Schedule 40 or Schedule 80 pvc for the buried conduit?

  • @shawngutierrez2097
    @shawngutierrez2097 ปีที่แล้ว +1

    Great job man. Succinct explanation 👍

  • @bentodd7549
    @bentodd7549 2 หลายเดือนก่อน

    According to code you must install a pull box every 360 degrees in bends you make in conduit

  • @rickm7209
    @rickm7209 ปีที่แล้ว +2

    I don’t think NEC allows for underground Romex. PVC conduit under NEC rules is 18” deep. You may need primer then glue for fittings - not sure.

    • @SeanFitz-vo4fm
      @SeanFitz-vo4fm 10 หลายเดือนก่อน

      Primer may not be required if the glue manufacturer does not state that it is required. The 'electrical' pvc glue sold in Home Depot is different than the 'plumbing' glue. The plumbing glue usually requires primer.

  • @michaelramsey7592
    @michaelramsey7592 3 หลายเดือนก่อน

    Great video. Since the shed is not on concrete, why didn't you dig under the frame and come up on the inside?

  • @kevinstenger4334
    @kevinstenger4334 ปีที่แล้ว +17

    You did nice work and it works for you but much of it is illegal. It’s one thing to do stuff for yourself but doing a how to video to teach other people to do it wrong is something else. When you run conduit you should minimize the bends and by code you are not allowed more than 360 degrees of bends between openings such as boxes and conduit bodies. And since you used UF cable that is difficult to pull anyway that wire will never come out, if it fails the whole run will have to be torn out and replaced. I know you did it a section at a time but technically that’s illegal too since the code requires the raceway system to be complete before installing wire. You also can’t glue your conduit to the wall, a conduit strap is required. The other big mistake you made was installing your switch and lighting outlet boxes so that they are recessed. The box has to be flush with the surface of the wall or slightly protruding so that the cover or fixture mount to the face of the box. By having them recessed you have introduced combustible material to the inside of the space where your wire terminations are made, the most likely place for an arcing fault to occur and start a fire. Arc faults are several thousand degrees, more than enough to ignite your wood composite siding. Sorry, I’m not trying to be a nit picker just being critical but this was a how to video. The electrical code is a very complicated thing and takes years to learn and constant updating and re-education. Enjoy your shed, it looks great.

    • @tonyhartshorn3474
      @tonyhartshorn3474 8 หลายเดือนก่อน +2

      How did you figure out this guys address to know where he lives. Different areas have different codes. For example the area I live in has no codes or inspections. You seem to be an electrical contractor or an inspector. There for you should know he could use plastic box extensions if he chooses to cover the inside walls. If you don’t like his video kick rocks

    • @DavePerry-h5r
      @DavePerry-h5r หลายเดือนก่อน

      No codes, sounds plausible. I suppose nobody has fire insurance either?

  • @Stormorbiter
    @Stormorbiter ปีที่แล้ว

    When burying PVC conduit, be sure to use schedule 80
    If you are using 240V or non-GFCI protected, PVC conduit should be 18” deep

    • @pld8993
      @pld8993 ปีที่แล้ว +2

      There's no need to use Sch80 for burial, Sch40 is fine. Burial depth depends on location, anywhere from 0"-24".

  • @robertcarullo4926
    @robertcarullo4926 ปีที่แล้ว +2

    I don't know where your located, but you can't put a yellow romex under ground, it gets moisture and will rot. You need to use another type of wire coating, that runs into the conduit. unless your area says ok, florida you can't

  • @denniskazich7559
    @denniskazich7559 ปีที่แล้ว +1

    I would have ran extra amperage to shed and used stranded wire. Would hope wires could be pulled through conduit if necessary. Switches for exterior lights on shed should be installed inside house. Wouldn't have to run outside when the lights needed to be turned off. Good job on keeping burial depth in mind though.

  • @RD-sl8yl
    @RD-sl8yl ปีที่แล้ว

    I love the video and it looks perfect to me. I will def use this video as a reference! Thanks!!

  • @slimmm723
    @slimmm723 7 หลายเดือนก่อน +1

    Well Done , sir.

  • @nickbrutanna9973
    @nickbrutanna9973 9 หลายเดือนก่อน

    Is there a reason you have that hole drilled in the vertical 4x4 that you mounted your GFC outlet onto?

  • @trevorkerr8381
    @trevorkerr8381 11 หลายเดือนก่อน

    good looking shed

  • @brianblack8493
    @brianblack8493 6 หลายเดือนก่อน

    Nice how to video. I especially liked the min depth graphic. One question, for some reason I am under the impression I should only used lose wires and not romex though. Just want to get your opinion on that if you don't mind. ty!

    • @pld8993
      @pld8993 6 หลายเดือนก่อน

      You can't use NM (romex) underground, but you can direct bury UF cable or direct burial rated individual conductors. If using conduit, individual THHN conductors is your best option. Installing UF in conduit underground, while allowed, is amateurish and foolish.

  • @mikesheehan2172
    @mikesheehan2172 4 หลายเดือนก่อน

    How did your electrical inspection go?

  • @PatrickGuerrisi
    @PatrickGuerrisi ปีที่แล้ว

    How did you waterproof the conduit bends? THats what I dont know. Worried water will creep in on the 90 degree bend angle joins ( whatever they are called)

    • @pld8993
      @pld8993 ปีที่แล้ว +1

      You don't. All underground conduits end up with water in them, no waterproofing required.

  • @johnseitz6578
    @johnseitz6578 3 หลายเดือนก่อน

    Romex isn't to be used in wet areas even in conduit. UF-B is the right wire as soon as you go out of your basement. The best thing would be use single wire THHN all the way from the panel.

  • @jacksonnra1856
    @jacksonnra1856 ปีที่แล้ว +7

    I stopped using direct burial years ago. Not worth the extra dig or occasional tree planting that nicks it an causes issues..Conduit all day.

  • @sh2697
    @sh2697 ปีที่แล้ว +1

    I have a question: 1. If I use conduit (pvc) do I use wire or can the romex go inside. 2. for the exposed part, can I use the electrical pvc conduit or do I use the metal? 3. The reason is I am asking is because I have to go from outside wall to burying. I do not want to have to buy different wire I guess

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      Easiest would be to strip the romex and fish the raw wires through after assembly.

  • @bellarosegroup
    @bellarosegroup ปีที่แล้ว +3

    Not how i would have done it, but nothing wrong with it. good work. pulling romex through conduit is rough. I would have switched to thwn but i understand but i understand your process.

    • @pld8993
      @pld8993 ปีที่แล้ว +6

      Except for multiple NEC violations.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      if nothing else unsheath it as you fish it in.

  • @allenemiesforeignanddomest3320
    @allenemiesforeignanddomest3320 ปีที่แล้ว +4

    Could you just go with a GFCI breaker instead of an outlet before going below grade?

  • @YTSparty
    @YTSparty 9 วันที่ผ่านมา

    Everything I'm reading online says you can't use Romex outside especially in conduit. Or in an area that's considered damp or wet.

  • @MShort0
    @MShort0 2 ปีที่แล้ว +5

    Nice work. Would have liked to see the overhead led light at night!

    • @AndrewThronImprovements
      @AndrewThronImprovements  2 ปีที่แล้ว +1

      Can’t believe I forgot to include that! I just posted a reel on IG that shows the overhead LED at night over @Atimprovements. Thanks for watching, Matthew!

  • @bmbbrevs
    @bmbbrevs ปีที่แล้ว +5

    Your shed turned out great! These videos gave me some good tips while I’ve been building mine. I’m just about to do my electrical also and am trying to figure out if I can use romex inside. I was thinking of using the metal clad aluminum (MC cable) instead of romex since it will be permanently exposed. I really do not want to run conduit everywhere.

  • @713bvns
    @713bvns ปีที่แล้ว

    So once you run UF underground to a shed you can connect it to a switch or a outlet & then you can then switch to 12/2 romex? have a project coming up just wondering ..

    • @pld8993
      @pld8993 ปีที่แล้ว

      Yes

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      be prepared to leg it to the device to reset the GFCI once water condenses into that conduit from the air and causes false tripping. Better to bury the extra depth and not have to GFCI it.

  • @ghc7910
    @ghc7910 ปีที่แล้ว

    I’m doing this tomorrow but I’m burying under concrete to my garage from house do those depths still apply for concrete ?

  • @joebobjenkins7837
    @joebobjenkins7837 ปีที่แล้ว

    I had the contractor on my addition put in a designated 20 amp breaker with an outlet outside so that I could run power later on. Its now later on and Im not sure what gauge was used to route to the first outlet. Given the work they did on the rest I suspect its the bare minimum, likely 12ga, maybe even 14 ga. Total length from box to shed is gonna be about 100ft of run. Im worried I might need to rewire the initial run to 6ga wire. Thoughts?

    • @josearenas1805
      @josearenas1805 ปีที่แล้ว

      If it is only a 20 amp breaker. 12s are fine. If the run is over 100 ft I’d use 10s.

    • @thedavesofourlives1
      @thedavesofourlives1 8 หลายเดือนก่อน

      #6 would be if you needed 60A @ 240v . 100ft you'd probably be fine with 20A breaker but safer to use 15a breaker if you simple junction more #12 off (assuming that existing #12) . You can down the breaker size but not the wire size.

  • @jimh4167
    @jimh4167 ปีที่แล้ว +1

    IMO.
    I always over size my conduit runs
    and never let the conductors get tangled in the pull
    Then if other circuits or ? Are needed
    It's easy to use the ground wire to pull in more conductors

  • @markrherman
    @markrherman ปีที่แล้ว

    Nice job, but you'll need to walk to the house if you trip a breaker. Do you need to cover the exposed horizonal runs of Romex so that they can't be damaged from accidental contact or used to hang things or used as a ladder to reach higher items?

  • @dfj555
    @dfj555 ปีที่แล้ว +1

    Also, use 12 gauge for outlets and 14 gauge for light fixtures.

    • @KevinCoop1
      @KevinCoop1 ปีที่แล้ว

      That’s not NEC. Could be local though.

    • @armyfazer1410
      @armyfazer1410 ปีที่แล้ว +3

      12 gauge on 20 amp, 14 is good on 15

  • @puiricleaningrestoration6000
    @puiricleaningrestoration6000 5 หลายเดือนก่อน +2

    Romex can not be used in conduit in wet locations by code. You should have used different wire,

  • @patricksmith3135
    @patricksmith3135 2 ปีที่แล้ว +10

    Andrew you get better and better with each video. I loved the floor treatment, which I am considering for my screened porch. Thanks so much ; can't wait for more. Pat

    • @AndrewThronImprovements
      @AndrewThronImprovements  2 ปีที่แล้ว

      Appreciate it, Patrick! Thanks again for continually supporting the Channel!

  • @jeremiahnewsom7775
    @jeremiahnewsom7775 10 หลายเดือนก่อน

    excellent video!!!!!!!!!!!!!!!

  • @imrecordingtoo1374
    @imrecordingtoo1374 ปีที่แล้ว +6

    How many bends did you have between junction boxes?

  • @dennishillman6205
    @dennishillman6205 5 หลายเดือนก่อน +1

    Don't wrap two grounds around the recep ground screw. Pigtail to the recep.

  • @mytubebobbie06h
    @mytubebobbie06h ปีที่แล้ว

    Great job! It gave me some inspiration.

  • @dave_ecclectic
    @dave_ecclectic ปีที่แล้ว

    As this is how to add electricity to a shed and not run a wire, I will add that you can also add a battery system, possibly with solar to recharge it. (Called Portable power.)
    What it costs is offset by it's simplicity and may be better for some people. It might be cheaper also.
    You do have to recharge it. Either by carrying for smaller systems or wheeling it to a power source or adding a solar source to recharge it where it sits.
    He states 120V x20 amps= 2400 watts There are systems much larger than this.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      guaranteed it won't be cheaper. Likely not to code further yet.

    • @dave_ecclectic
      @dave_ecclectic 7 หลายเดือนก่อน

      ​@@thedavesofourlives1
      It may not be cheaper, but you don't know this in every situation. Long distances or rocky soil? Paying someone to dig the trench? Is it indeed guaranteed? But then I only said it _might_ be.
      Why would it not meet code?

  • @GNew6393
    @GNew6393 4 หลายเดือนก่อน

    I have been told that you should not piece together the conduit with the wire in it. Code is to be able to pull the wire through the conduit once it is in place with no more than 360 degrees of bend between pull points.

    • @pld8993
      @pld8993 4 หลายเดือนก่อน

      Correct

  • @bruceboyles1895
    @bruceboyles1895 11 หลายเดือนก่อน

    One thing, then you pulled the wire through the conduit before gluing it up, how would replace the wire if you ever have to? Is this code in your area?

    • @pld8993
      @pld8993 10 หลายเดือนก่อน

      It's a code violation to do it the way he did. Conduit must be complete before cables or conductors are installed.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน +1

      if you can't pull it the first time, you built it wrong (more than 360 degrees of bends)

  • @_mylastname
    @_mylastname ปีที่แล้ว

    So I'm using 8awg THWN for 220/240v 100' away... Flexible PVC conduit... That needs to be 18" depth correct?

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      Depends on your local codes. Best practice would be to go 24", gravel 6" then warning tape and fill.

  • @outlet6989
    @outlet6989 ปีที่แล้ว

    Thanks for your informational video. You should add KLEIN TOOLS Clear Wire Lubricant to your list. It will make wire pulling much more effortless.

    • @thedavesofourlives1
      @thedavesofourlives1 7 หลายเดือนก่อน

      hahaha this guy doesn't pull he pushes wire

    • @buggsy5
      @buggsy5 15 วันที่ผ่านมา

      @@thedavesofourlives1 Which is why he couldn't glue the sections until the wire had been pulled. Yes, "snot" makes the wire pulling much easier.

  • @martybillich5430
    @martybillich5430 ปีที่แล้ว

    Good coverage, well done.

  • @thomasroemen1953
    @thomasroemen1953 ปีที่แล้ว +1

    The wire would pull through the pipe more easily if you unrolled it first. Doing so removes the twist.

  • @AlexeiTetenov
    @AlexeiTetenov ปีที่แล้ว

    Thanks for sharing!

  • @Ron-xn4wf
    @Ron-xn4wf 6 หลายเดือนก่อน

    Did you get a electrical permit from the building inspection department ?

  • @pinecorey
    @pinecorey ปีที่แล้ว +1

    Looks easy enough.😳

  • @KurtNoakes
    @KurtNoakes ปีที่แล้ว +13

    Should use THHN wire in conduit. Not romex.

    • @bizzfo
      @bizzfo ปีที่แล้ว +2

      UF-B isn’t Romex

    • @KurtNoakes
      @KurtNoakes ปีที่แล้ว +1

      @@bizzfo I think UF-B is much more expensive. When I was an electrician we direct buried UF-B but used THHN in conduit. It's been a lot of years so I may be wrong.

    • @bizzfo
      @bizzfo ปีที่แล้ว +1

      @@KurtNoakes putting UF-B in conduit isn’t a matter of violating code. If anything it’s overkill and a pain in the rear. you’re not going to fail inspection as a result.

    • @KurtNoakes
      @KurtNoakes ปีที่แล้ว +1

      @@bizzfo Yea, I remember that stuff being hard to strip. People watch these videos to see the best way to do something. and we don't want to spread bad info. I thought the video was showing romex being pulled through the conduit. Sorry if I offended anybody

    • @dhazz1536
      @dhazz1536 ปีที่แล้ว +6

      @@KurtNoakes you are correct! Romex should not be ran in that length of conduit. Romex is not rated to be in conduit. Romex is usually ran in a conduit when it comes from a protected area to a non-protected area. I.E. coming down a garage wall from the attic. This video should be taken down simply for the NEC code violations. Electricity is dangerous and ridiculous videos like this make it worse!