How to Run Underground Power to a Shed the Easy Way

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 พ.ย. 2024

ความคิดเห็น • 503

  • @AprilWilkerson
    @AprilWilkerson  ปีที่แล้ว +16

    Big thank you to FOREO for partnering with me on this video! Treat your significant other (or yourself) with a great gift by FOREO Sweden at the link below and don't forget to use the coupon code APRILW20 for 20% the UFO 2 collection here: foreo.se/o69q

    • @alexisbeeton5416
      @alexisbeeton5416 ปีที่แล้ว +1

      I love to watch your videos - women really can do everything and you are right, we can look great too and I checked out this device, it really has cool features. Thank you!

    • @thedavesofourlives1
      @thedavesofourlives1 8 หลายเดือนก่อน

      get out your hair dryer/heat gun and make that down drop of PVC conform to the wall.

  • @pawsnazzy01
    @pawsnazzy01 ปีที่แล้ว +46

    April, when running power to my shop build, My son had a piece of rag that he tied to some nylon string. He then went in to garage where the conduit was going to the main panel turned on the shop vac and it sucked that rag & string thru in about 2 seconds and he tied and taped the wire and pulled it back to the shop ,the whole thing took just a couple mins.

  • @michaelc.3812
    @michaelc.3812 ปีที่แล้ว +131

    I’m sure others may have said the same, but it’s not allowed to run NM cable (some call it Romex, which is a trade name) in conduit that goes outdoors. If you are using cable that’s rated for direct burial, you should be okay (but good to check with inspector). So the wire from the panel to the junction box should be non-NM and something like THHN wires, but not standard NM). I’m a master electrician and ICC licensed electrical inspector.

    • @bruceyyyyy
      @bruceyyyyy ปีที่แล้ว +5

      I did a similar install to get a lamp post in my yard. I used THHN in PVC conduit through the garage to an outlet on an exterior wall.
      From the GFCI exterior outlet I switched to UF-B cable but there is about 2' of UF-B in the conduit before it gets underground.
      Is this acceptable or should I change it?

    • @tomhackett3395
      @tomhackett3395 ปีที่แล้ว +18

      I am still amazed that there's a type of cable that you just put in the ground directly exposed to the dirt?! Is it bad to run it within conduit for the entire length? I'm paranoid that moles will eat my electrical wires or something.

    • @jimmyyounger618
      @jimmyyounger618 ปีที่แล้ว +12

      @@tomhackett3395 You should be fine. I opted for a buried primary service line instead of overhead wires for roughly a 100 yard run from the road to the house. From the meter to 2' under is in conduit, but the rest is direct burial. In service since '99 and never a problem despite driving tractors over the soppy ground above it and burrowing critters of every kind. Like you, I had my doubts but all's good! Likewise, I have various runs of direct burial lines to several outside locations and have never had an issue.

    • @kevinlynch3372
      @kevinlynch3372 ปีที่แล้ว +3

      Curious what is the reason code won’t allow NM cable?

    • @lohnjones3307
      @lohnjones3307 ปีที่แล้ว +16

      ​@@kevinlynch3372 It's not waterproof -it has paper inside

  • @ron827
    @ron827 ปีที่แล้ว +200

    It is good practice to lay a yellow caution tape in the trench after some backfill has been added. When someone is digging in the area of the underground cable, they will encounter the caution tape before they get too close to the cable.

    • @jamesrawlings8493
      @jamesrawlings8493 ปีที่แล้ว +11

      I believe the tape is required by the NEC.

    • @Windex451
      @Windex451 ปีที่แล้ว +13

      I believe it should be Red

    • @hotpuppy1
      @hotpuppy1 ปีที่แล้ว +3

      That won't do any good if the length of the shovel blade reaches the cable. Tile spade depth is pretty close. Caution tape won't provide any resistance.

    • @ron827
      @ron827 ปีที่แล้ว +10

      @@hotpuppy1 Keep your day job. "-)

    • @txmade4371
      @txmade4371 ปีที่แล้ว

      Naw.

  • @lucianprescott8357
    @lucianprescott8357 ปีที่แล้ว +4

    Every electrical video I’ve ever watched will state “if your not comfortable doing this work, call in an electrician”, which is sound advice. However, anyone can do the manual labor (digging trenches, running the wire, backfilling) prior to calling in the electrician, thus saving a ton of money.
    Had a project similar and ran a line 75’ from a house panel to a garage. Found out the code requirements, did the labor and then call the electrician. He was happy, because I had set up everything for him and all he had to do was set the wires in proper order. Saved 15 hundred on the project by doing some of the work myself.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน +1

      Good advice for those afraid of doing this type of work.

  • @mattstosh6960
    @mattstosh6960 ปีที่แล้ว +7

    I watched this video 3 times. You make this appear simple. I can't even find the same PVC pieces at Lowes or Home Depot. Love that ( 5:02 ) smile while dealing with not-so-easy cable. Thank you for the video....

    • @jimmac1185
      @jimmac1185 ปีที่แล้ว +7

      They are in the electrical isle, not plumbing.

  • @perrycollier2989
    @perrycollier2989 ปีที่แล้ว +17

    April I used to work for a company that made a lubricant to pull electrical wires (romex). The lubricants are just glycerin so one might be able to save some money and just use glycerin. As always great video, very informative.

    • @normferguson2769
      @normferguson2769 7 หลายเดือนก่อน

      I have always used kitchen dish soap to lube the wire.

  • @dreport9433
    @dreport9433 หลายเดือนก่อน +3

    This is the most informative tutorial, i have watched on youtube. No filler. No 8 minute introduction and watching you talk for those 8 minutes. You got to the point. You showed us. You educated us. Wonderful. Thank you.

    • @AprilWilkerson
      @AprilWilkerson  หลายเดือนก่อน +1

      Thanks! Glad you enjoyed it. Thanks for watching.

  • @glencrandall7051
    @glencrandall7051 ปีที่แล้ว +11

    The hard part is digging the trench for the wire. Thank you for sharing. Have a great day and stay safe. Be careful the electrons can bite.🙂🙂

    • @keithmyers1454
      @keithmyers1454 ปีที่แล้ว +2

      It took my wife two weeks to dig a 20 ft trench so I could put the wires into it, she ran into a lot of rocks, she did cover it up faster though

    • @dougb8207
      @dougb8207 11 หลายเดือนก่อน +3

      That's actually what I was hoping to see taught, when I clicked on the video. I've heard water pressure, maybe a pressure washer, can be a good way to go.

  • @georgevanvalkenburg2560
    @georgevanvalkenburg2560 ปีที่แล้ว +8

    ALWAYS READ THE COMMENTS. THE BRILLIANCE OF A COMMENTER IS NEVER OVERSTATED!

  • @Aepek
    @Aepek ปีที่แล้ว +7

    1:45 can also buy fittings to allow for different bends, if don’t wanna flex the conduit like this (sweep 90s, [also called elbows], street, bell ends, saddle bends, etc); and if don’t want to buy the different fittings (or can’t find), you can heat up and bend the conduit yourself (pvc only, as emt not gonna be heated and bend, gotta use a bender; and ABS doesn’t heat well and wouldn’t even try it, imo)…..just a tip for ppl if feel weird about flexing the conduit how April did.

  • @dennishinkle5010
    @dennishinkle5010 ปีที่แล้ว +3

    I ran direct burial wire and stayed away from PVC. A little extra work but worth it. You are truly great.👍♥️

    • @alamofox1
      @alamofox1 ปีที่แล้ว +7

      Physical protection is required when emerging from grade.

  • @antzlowe7529
    @antzlowe7529 ปีที่แล้ว +3

    Hey April I am a beginner woodworker from New Zealand and I have watched I think all of your videos. I cant thank you enough for all your talant and know how. You explain everything so beginners like me can do anything when it comes to woodworking. I have subcribed to your channel and look forward to seeing alot more videos once again thank you.

  • @josephknapick5307
    @josephknapick5307 ปีที่แล้ว +174

    Your first run of Romex to the GFCI is a code no-no, even inside of PVC conduit. NM cable (ROMEX) is not permitted in damp or wet locations [NEC 334.12B(4)] and the inside of raceways (including PVC conduit) located outdoors is considered a wet location per NEC 300.9. Your first run should be UF cable or individual THWN conductors. If the latter, the individual conductors should be placed in conduit all the way to the source panel.

    • @jackww839
      @jackww839 ปีที่แล้ว +13

      Texas has very lenient/substandard codes.😒

    • @rayrayber_
      @rayrayber_ ปีที่แล้ว +6

      This is texas are codes are different from were ur from I can see

    • @DragCadRacing
      @DragCadRacing ปีที่แล้ว +8

      At about 3:30, the text box says “UF cable”.

    • @josephknapick5307
      @josephknapick5307 ปีที่แล้ว +5

      @@DragCadRacing Prior to that, ROMEX is used from the inside to the GFCI box....

    • @simsreject5925
      @simsreject5925 ปีที่แล้ว +20

      ​@@rayrayber_ The N in NEC stands for national. These are unified codes adopted by many states, including TX, as the baseline for electrical and fire safety.

  • @Gk2003m
    @Gk2003m 11 หลายเดือนก่อน +4

    There is flexible conduit, outdoor rated. I used that to run AC, along with outdoor-rated speaker wire, out to my shed. The great benefits: a) flexibility allows you to maneuver around large underground obstacles; b) zero underground junctions, so no leakage or seepage of water into your conduit. It’s been a godsend for Xmas lighting, as well as for outdoor stereo audio. I can run a powered subwoofer. The garden sounds amazing

    • @MelissaHuffman-k7x
      @MelissaHuffman-k7x 6 หลายเดือนก่อน

      Electric code only allows a maximum of 6’ of use, for flexible conduit.

    • @Gk2003m
      @Gk2003m 6 หลายเดือนก่อน

      @@MelissaHuffman-k7x only if the flexible conduit has no reinforcement. Mine is reinforced conduit, and is therefore up to code.

  • @jljohnson9438
    @jljohnson9438 ปีที่แล้ว +5

    This video was at just the right time as I am getting ready to feed electricity from my old shed to the new garage that is right next to the shed. Watching you do this is the exact same process that I will need. Thank you.

  • @danstewart7316
    @danstewart7316 ปีที่แล้ว +6

    I saw others mention the romex issue so check those comments out. I would mention that any electrical pvc pipe exposed needs to be schedule 80 and not your typical schedule 40. I am impressed with your knowledge of the burial depths, not many know that.

    • @daveroth8060
      @daveroth8060 ปีที่แล้ว

      It does not have to be SCH 80

    • @njineermike
      @njineermike ปีที่แล้ว +2

      ​@@daveroth8060 Yes it does. It can be sch 40 below 18" or inside the structure, but above ground and outside it must be sch 80.

  • @jimmyyounger618
    @jimmyyounger618 ปีที่แล้ว +37

    Good work! But I'll add that 20 years ago I didn't anticipate my similar project would be more permanent than I anticipated at the time. (My purpose then was to get power to a deicer at a livestock water tank.) During this period, the PVC outlet's year-over-year exposure to the sun caused it to degrade and become chalky, brittle and inflexible. A little post movement during an unusually wet year with a super freeze cracked the riser pipe, and the hinged cover on the outlet box fell apart. If I had a do-over, I'd have gone with metal over PVC despite the added work.

    • @hamadilawson4396
      @hamadilawson4396 ปีที่แล้ว

      How much more resistant to corrosion is the pvs vs. meral conduit. It it emt conduit?

    • @TheHighKirk
      @TheHighKirk ปีที่แล้ว +2

      There are different grades for the PVC.

  • @1956arc
    @1956arc ปีที่แล้ว +4

    Nice job!
    It is important to understand voltage and amperage needs to be considered when determining depth of wire. A residential 20 amp circuit using 12/2 copper underground rated cable can be installed at a 12” depth as long as it is protected with GFCI device.
    Electrical codes can be more stringent depending on where you live so please consult an electrician or electrical inspector in your area.
    Also it is important to note that schedule 80 pvc should be used in this application.

  • @davidhoover2446
    @davidhoover2446 ปีที่แล้ว +3

    Nice easy description. Don’t forget to water/air/bug seal the holes once finished.

  • @mach51
    @mach51 ปีที่แล้ว +8

    Nice, you can use heat gun to form the plastic conduit to fit flush against the wall

  • @abbayhvhreigns7iloveyeshua650
    @abbayhvhreigns7iloveyeshua650 ปีที่แล้ว +4

    Another quick project Wonderfully explained. This is time well spent on a Sunday. Thank you April, See you again Soon. Have a Blessed Week.

  • @Immolate62
    @Immolate62 ปีที่แล้ว

    Just did a similar project running 50 amp service from from "main" panel to my shop (who builds an 1,100 sq ft shop with only two 15 amp circuits?). I had to chase it across the entire attic in the house so I used 6 AWG Romex to the edge of the house with no conduit, then put a junction box to connect to 3/4 inch flexible conduit. The conduit came down the wall outside, buried two feet under ground for a 13 foot run across to the shop then up to an LB and into the shop, all one continuous 38' bit of conduit and using 6AWG THHN. The shop is 32x32 concrete block. The conduit continues inside for the very short run to the sub panel (about 18").
    I could have gotten away with an 18" burial, or I could have used UF to simplify things a bit, but I'm glad I went the way I did.
    I had a good friend who is a licensed electrician help me with the attic work since I'm too old and inflexible for that rather cramped space. It was really just securing the Romex and splicing the Romex to the THHN in the junction box. He knocked it out in under an hour. Thankfully it was a reasonable cool Florida day in March with heavy cloud cover, so the attic wasn't dangerously hot, which is the default setting for Florida. I did the trenching myself, and learned all about the surprisingly lax codes for PVC thickness and burial depth for irrigation in Florida. Don't ask me how I know. Let's just say that if you made a pipe out of Playdoh, it would be sturdier.

  • @jimpovolish540
    @jimpovolish540 ปีที่แล้ว +6

    conduit the full run is a good idea as well and not much more expense and also don't forget to silicone seal those LB boxes at the building to prevent water penetration!

    • @jimurrata6785
      @jimurrata6785 ปีที่แล้ว +1

      You're not supposed to run Romex in conduit. (it can guard Romex in accessable areas)
      Sealant definitely, but more likely ductseal than silicone, and possibly intumescent sealant if habitable space. Depending on AHJ

    • @luvdady
      @luvdady 8 หลายเดือนก่อน +1

      ​@@jimurrata6785old tale ..
      But it's definitely not fun to do compared to stranded

    • @jimurrata6785
      @jimurrata6785 8 หลายเดือนก่อน +1

      @@luvdady Well, I just pulled 100' of 10/3 in 3/4!!! So I hope it's good.
      Thanks for your reply! 😉

  • @ThraX_86
    @ThraX_86 ปีที่แล้ว +15

    Hey April,
    Great video. The nice thing about PVC is if you run into this later on with a project again, you could use a heat gun and apply a slight offset off the metal building over the concrete lip into the ground (1:43). By just applying a few minutes of heat along the pipe, you can shape it without any fittings. I used to do this when I was an apprentice electrician years ago, and it would work great on jobs.

  • @jonathanm9436
    @jonathanm9436 ปีที่แล้ว +32

    Interesting code requirements. By comparison, in Australia we are required to bury the wire in conduit the whole way at 600mm (2ft), with warning tape just above the conduit. It can be shallower (not sure how much) if there is mechanical protection like concrete.

    • @Outback_Truckie
      @Outback_Truckie ปีที่แล้ว +7

      Don't forget we also have to use a licenced electrician for all electrical work. 👍

    • @jonathanm9436
      @jonathanm9436 ปีที่แล้ว +2

      @@Outback_Truckie True dat. 240 scares me!

    • @w.knudsen5570
      @w.knudsen5570 ปีที่แล้ว +3

      Here in the states, uf rated wire may be used for direct burial.

    • @mellowrebel4618
      @mellowrebel4618 ปีที่แล้ว +1

      @@Outback_Truckie WE DO HERE.HER I SHE NEEDED TO ALSO PULL A PERMIT!!!

    • @alamofox1
      @alamofox1 ปีที่แล้ว +4

      US NEC also requires a minimum cover of 24 inches. There is an exception that allows 12 inches but she didn’t discuss this.

  • @dalematherly5394
    @dalematherly5394 ปีที่แล้ว +3

    Others may have said it, but direct bury cable has to be 2’ deep regardless of what material your risers are.
    Shallower permitted if entire run in conduit.
    This is to protect wire from damage from digging.

    • @nyetloki
      @nyetloki 11 หลายเดือนก่อน

      False. GFCI protected UFB cable on a 120v 20a circuit can be direct buried at 12 inches.

    • @TheHavocdog
      @TheHavocdog 6 หลายเดือนก่อน

      ​@nyetloki Only in schedule 80 conduit.

  • @clinttalmadge796
    @clinttalmadge796 10 หลายเดือนก่อน +9

    Not including an advisory about the length of the wire run and amperage draw dictating the gauge of the wire needed can set a dangerous situation. As a clerk in the electrical department of a large DIY store, I had many customers who wanted to run 14 or 12 gauge wire in excess of 100' to run shop equipment in an stand alone workshop. I calculated on one case that the fellow would need 4 gauge for what he was proposing. He accused me of trying to make more money off him. I told him that I was paid by the hour and I made the same if he bought the right wire, the wrong wire or no wire at all. Please consider adding such advice.

  • @Aepek
    @Aepek ปีที่แล้ว +9

    Always have fun watching and seeing what you do next April. Your vids are always fun, filled with different info; and can tell you enjoy doing each project 👍🏻
    Also do like the voiceover and are always TALKING TO US, every step of the way, thx.
    Cheers✌🏻

    • @AprilWilkerson
      @AprilWilkerson  ปีที่แล้ว +4

      Thanks! Glad you like them. Thanks for watching.

  • @lnsdetailingmechanical5440
    @lnsdetailingmechanical5440 ปีที่แล้ว +5

    In Australia we need to be 600mm minimum deep with warning tape 100mm above the conduit. Also pull your cable through first then make you joins. It makes for a much easier and quicker job without the struggle. Anyway different regulations for different states and countries. Good to see your having a go and not scared to get your hands dirty 😊well done and look forward to seeing your next job 👍👍

    • @alamofox1
      @alamofox1 ปีที่แล้ว +1

      She is in violation of NEC 300.5. 24 inch minimum cover for direct buried cable.

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน

      @@alamofox1 no, 24 inch min for direct buried cable if not GFCI protected... she alludes to this in the video... 300.5 column 4. 12 inch if GFCI protected and 20 amp max circuit.

  • @louroberts5567
    @louroberts5567 ปีที่แล้ว +1

    Good morning, April! Thanks for another great video. This project is actually penciled in on my "GET IT DONE" list for the warmer weather. Have a great week! God bless.

  • @mikeslater6246
    @mikeslater6246 หลายเดือนก่อน

    I see a lot of good information from other commenters about using underground as opposed to romex. I've heard this from other sources. The only thing that I would add to the comments about this video is instead of running the full length of the cable that's going to start at your GFCI through that piece of conduit going into the ground and then to the shed, I would pull a string into that conduit and then pull the three or four feet necessary from the underground exit point of the conduit back up to the GFCI outlet box.

  • @HighCountryRambler
    @HighCountryRambler ปีที่แล้ว

    Great work April. I was running a direct burial line out to my barn, I flunked my inspection because I crossed a driveway at 16" depth, not 18". Geeezz.

    • @RobertBeck-pp2ru
      @RobertBeck-pp2ru ปีที่แล้ว

      Codes are meant to be followed. Eighteen inches is the minimum. Play it safe. Go 24" or even 30".

    • @HighCountryRambler
      @HighCountryRambler ปีที่แล้ว +1

      @@turdferguson12 I live on a ranch in very rural Colorado out in the middle of God's country. Prior to building the house I built a barn, I was bringing new service in from county roads to barn (4 miles). The only way ANY public utility will bring in new service is with a electrical permit, which are governed by states who share the same codes.
      I chose to trench 2 inches deeper, rather than spending winter and nights freezing in the dark. Plus my welders and barn heaters don't make good pasture ornaments.

    • @SmallSpoonBrigade
      @SmallSpoonBrigade ปีที่แล้ว

      @@RobertBeck-pp2ru Yes, the code is intended to be more or less the minimum that is acceptable. You can go above it to the extent that the gear and budget exists, but code does get updated over time for situations where it proved to be insufficient.
      It may not seem like some of this is a problem, but things like the spacing on outlets does typically address a problem, just not always an obvious one.

  • @nyetloki
    @nyetloki 6 หลายเดือนก่อน +1

    Just to clarify, the GFCI should be BEFORE the underground cable run, not just anywhere on the circuit. So at the panel (gfc breaker) or an intermediate GFCI outlet as you did.

  • @timruff9515
    @timruff9515 ปีที่แล้ว +24

    Just remember you could have just back fed the underground cable so you only had to pull 5 feet or so rather than feeding all the cable through the box...

    • @bishopp14
      @bishopp14 ปีที่แล้ว +4

      Yeah, I was thinking the same thing. Great video though!

  • @BearCreekWoodworking
    @BearCreekWoodworking ปีที่แล้ว +3

    It seems to me that so many content creators avoid showing electrical installations on the videos. However, April you are brave enough to make electrical videos time and time again. Congrats to your “Can Do Spirit “!!! 😃👏

    • @AprilWilkerson
      @AprilWilkerson  ปีที่แล้ว +1

      Thanks! Yes, people love to rake me over the coals for these videos but always show what I did and how I did it. Thanks for always watching.

    • @DanTheisen
      @DanTheisen ปีที่แล้ว +5

      True. Content creators who are not electricians really should not, in my opinion, demo electrical work. I do a little work around my house, have consulted electricians about what I do, but I won’t put electrical work on video. I love April’s channel and work, but don’t consider showing clear code violations as “brave”.

    • @richardroffers2530
      @richardroffers2530 ปีที่แล้ว +1

      @@DanTheisen Well stated. I agree 100%...IMO, read the code. Follow it. If something is not clear, ask an electrician. Do the work, but don't advertise it.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      What were her violations, Dan? @@DanTheisen

    • @DanTheisen
      @DanTheisen 11 หลายเดือนก่อน

      @@rosewoodsteel6656 read the top rated comment. The one right under April’s. And please know my words are directed at Bear Creek’s comment. I continue to watch all of April’s videos and love what she does, generally.

  • @WillysPerformanceCycleCtr
    @WillysPerformanceCycleCtr ปีที่แล้ว +10

    This is a great idea and instruction set. I have a detached building that I need to run power to and will use your method! Thanks so much for your intuitive videos! Have a great day April!

  • @sherwoodstolt1027
    @sherwoodstolt1027 3 หลายเดือนก่อน

    In my county you also need to pay a small fee, get a permit and have it inspected prior to filling the trench. Later on if you sell the house, get a new mortgage or get homeowners insurance they will make you to sign a form stating no electrical work was done without a permit and inspection.

  • @w.knudsen5570
    @w.knudsen5570 ปีที่แล้ว +2

    Code for how deep to run your conductor is 24 inches without protection. If the run is under a sidewalk, driveway, etc you may have it 12 inches under such protection. Recheck the NEC. I did when I ran power to my shed a year a year ago. It had not changed since I was in a NEC class back in the 90's.

    • @kevinbowers4394
      @kevinbowers4394 ปีที่แล้ว +5

      Column 4 of table 300.5 in the NEC is what she referenced for her depth. She's running a single 20A 120V circuit with a GFCI and that allows her to use that 12" depth.

    • @nyetloki
      @nyetloki 11 หลายเดือนก่อน +1

      GFCI is the protection, for a 120v 20a circuit with a UFb rated cable.

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน

      @@kevinbowers4394 yep, people gotta read all the code, it's not always clear at first glance...

  • @nusermane1076
    @nusermane1076 ปีที่แล้ว +3

    Nice video again 👍
    Consider adding also Ethernet cable whenever you run cables between or in buildings, it comes in sooooo handy if you need to expand your Wi-Fi on your property … yes, Wi-Fi mesh works, but there are many draw-backs, so good ol‘ wire is a good thing to put in.
    If you can use cat7, from my experience it’s not much more expensive than cat6(a), but shields against all kinds of interferences ;)
    Cheers 🥂

    • @royreynolds108
      @royreynolds108 ปีที่แล้ว +3

      Ethernet cable nor coax should be included together with power wires in the same conduit. Use separate conduits in the same trench.

    • @nusermane1076
      @nusermane1076 ปีที่แล้ว +3

      @@royreynolds108 Yes, that’s true.
      And, even if direct burial wires are a thing, conduit between buildings is definitely worth it, to avoid digging later again, if some changes are needed 😉

    • @canlib
      @canlib ปีที่แล้ว

      Nah

    • @jack6539
      @jack6539 10 หลายเดือนก่อน

      If running copper utp cable, your nw performance will suck badly. Running utp in parallel with power without shielding is guaranteed to hobble your performance. Worst case I saw was when some Muppet actually wound the utp around the power cable. If using fibre, no problem ( but b3st to have it in its own conduit as its more fragile. Standards state that utp must only cross power cables at a 90degree angle.

  • @RyanBrem0504
    @RyanBrem0504 ปีที่แล้ว +12

    Another thing: if you do put in a gfci or outlet outside, be sure it is a weather proof

  • @deview123
    @deview123 ปีที่แล้ว +4

    I take it that Romex wire you used was solid wire? When I did underground wire pulls, I always ran conduit from one end to the other, then pulled stranded wire. It’s a little extra work, but it’s easier for one person. Thank you April for another great video

    • @daveroth8060
      @daveroth8060 ปีที่แล้ว

      They don’t make stranded Romex cable fool.

    • @deview123
      @deview123 ปีที่แล้ว +1

      @@daveroth8060 yes I know. I was referring to thnn individual stranded wire

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      No $hit Sherlock. @@daveroth8060

  • @tsquare9168
    @tsquare9168 ปีที่แล้ว +20

    You didn't put a service loop on the cable in the LB box. Where you used your foot to bend the conduit to the wall, heating the pipe with a torch would allow for you to bend the pipe to fit the contour of the wall. Also, the conduit where you fitted the male connnector, you can ream the inner edge to a smooth and tapered edge that's no longer sharp.

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน

      service loops are not required by code.

  • @dcfan1107
    @dcfan1107 ปีที่แล้ว

    PM screwdriver...cool. I bought a couple of sets from Walmart back in the mid 90's. Made in USA. Never seen anyone else use them. Still have them.

  • @robertjames-life4768
    @robertjames-life4768 ปีที่แล้ว +3

    A fish tape also helps get wire through conduit. 👍

  • @wayneburba9457
    @wayneburba9457 ปีที่แล้ว +3

    For your offsets near building, instead of your foot, a happier blow dryer or heat gun on low slowly over conduit will mold conduit .

  • @HomeDIYSStuff
    @HomeDIYSStuff 17 ชั่วโมงที่ผ่านมา

    Let the hole saw work. Manhandling it will cause it to split in half over time. The housing can't take that rough handling unless it's all metal. Heat the tubing to shape it. Any heat gun will work. lol Otherwise over time it'll pull the screws out. Take your time and think it thru. You go girl!

  • @TexasCanuck
    @TexasCanuck ปีที่แล้ว +3

    the hard part is digging the trench - that is the part I thought you found an "easy" way to do :)

  • @rubenmorales5830
    @rubenmorales5830 9 หลายเดือนก่อน

    Your awesome April I wish I had half the talent you have! Thank you for all you do!

  • @electricianron_New_Jersey
    @electricianron_New_Jersey ปีที่แล้ว +1

    It's decent but here in the northeast the UF (which stands for "underground feeder") will undoubtedly fail. I fix and repair stuff like this all the time and always install the PVC for the full run.

  • @tsjuno
    @tsjuno ปีที่แล้ว +13

    I feel like it’s easier to just run the pvc underground all the way and pull in stranded wire after. I hate fighting solid wire.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      I totally agree, TsJuno. In this case, she didn't run the UF in conduit the entire run, just in the vertical drops to protect the cable from grade to the wall penetrations.

  • @DoctorNoMD
    @DoctorNoMD ปีที่แล้ว +1

    Thanks for this video, April. I'm thinking about a project in our yard, and this gave me some great things to think about in my planning.

    • @AprilWilkerson
      @AprilWilkerson  ปีที่แล้ว

      Awesome! Glad it was helpful. Thanks for watching.

  • @olddawgdreaming5715
    @olddawgdreaming5715 ปีที่แล้ว +2

    Thanks for sharing April, worked out good and SAFE too. Fred.

  • @sparkythebuilder
    @sparkythebuilder ปีที่แล้ว +15

    Nice job. The only thing I saw that was not correct is you ran standard NM-b cable from the inside to the box that will have the GFCI. NM cable is not rated for wet locations and any conduit installed outside is considered a wet location due to condensation. To get around this you can run the cable directly into the back of the box that will have the GFCI.

    • @k4x4map46
      @k4x4map46 ปีที่แล้ว

      yeah I was going to ask that very same question even looking up the romex color codes...great observation!

    • @NiHaoMike64
      @NiHaoMike64 ปีที่แล้ว

      Or put the GFCI indoors, that will protect the GFCI itself from temperature extremes so it would last longer and provide a good place to plug in a Homeplug adapter for extending network to the remote location.

    • @gregbell2117
      @gregbell2117 ปีที่แล้ว +1

      I thought GFCIs only protected what was plugged into them, not the circuit they were on?

    • @sparkythebuilder
      @sparkythebuilder ปีที่แล้ว +5

      @@gregbell2117 You can wire them to protect everything downstream of the GFCI by using the LOAD terminals on the device.

    • @rupe53
      @rupe53 ปีที่แล้ว

      @@NiHaoMike64 ... these days they make GFCI outlets with WR printed on them to mean WET RATED so they will last outside.

  • @tjanecki
    @tjanecki ปีที่แล้ว +1

    What a great vid, thank you! Also like the helpful and respectful comments. Thanks everyone!

  • @jonanderson5137
    @jonanderson5137 2 หลายเดือนก่อน

    With all the digging and time invested, people should consider bringing a sub-panel to sheds and garages.

  • @mafosa8519
    @mafosa8519 ปีที่แล้ว

    Sometimes heating the cable at the turning point helps it bend easier.
    In cold climates the outer coating can micro crack.
    Nice job though!
    Larry

  • @bobniles1928
    @bobniles1928 ปีที่แล้ว +58

    The Romex you used from the panel to the outside receptacle is a violation. Conduit outside is a wet location. You should have used UF.

    • @michaeld9682
      @michaeld9682 ปีที่แล้ว

      Link please

    • @bobniles1928
      @bobniles1928 ปีที่แล้ว +2

      310.1 O(C)

    • @jakesmith2341
      @jakesmith2341 ปีที่แล้ว +2

      Thank you. I won't make the same mistake. Hopefully it won't make a difference either way.

    • @scwfan08
      @scwfan08 ปีที่แล้ว +1

      Like it says on the screen at 3:28.
      So she didn't even follow the rules she statet herself 😂

    • @GageDrums
      @GageDrums ปีที่แล้ว +5

      @@scwfan08 lmao yup.. UF.. Underground feed.. Not nm-b.. Crazy people with no research make how-to videos. She also did 220v outlets in her garage and ran multiple outlets off the same breaker.. For 220v..she shouldn't be making electrical tutorials lol

  • @DrGreenGiant
    @DrGreenGiant ปีที่แล้ว +9

    Very interesting to see different electric standards across the world! This wouldn't be legal here in the UK.
    Might be worth specifying in your video which standards you come under when doing work on electrical work so people don't get (unintentionally) misled into doing something dangerous because they trusted you.

    • @JonEHolland
      @JonEHolland ปีที่แล้ว +6

      This isn’t legal in the US either.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      Other than her not being a licensed electrician, could you name the code violations, Jon? I'd like to know what she did wrong, not trying to be a pita. @@JonEHolland

  • @albatross5466
    @albatross5466 ปีที่แล้ว +6

    The conduit coming out of the ground should have an expansion joint. You don't need to use UF cable, you can use any cable that has an insulation rated for wet applications. THNW is a lot easier to pull. UF can be used for direct burial. The 12' burial is for 125V max 20 A max.

    • @Zach_Miller
      @Zach_Miller ปีที่แล้ว +2

      This was direct burial

    • @albatross5466
      @albatross5466 ปีที่แล้ว +1

      @@Zach_Miller I thought I saw a conduit from grade to the cabinet. No?

    • @jacobrobbins6181
      @jacobrobbins6181 ปีที่แล้ว +1

      ​@@albatross5466The conduit was only used to get the cable to the bottom of the trench on either end. She didn't run pipe the length of the trench.

    • @nyetloki
      @nyetloki 11 หลายเดือนก่อน

      ​@@albatross5466 you have to protect the UFB from depth to above. Anything above depth up to 8 feet needs conduit.

    • @albatross5466
      @albatross5466 11 หลายเดือนก่อน

      @@nyetloki I incorrectly assumed that she had run conduit for the full length of the trench. Others have pointed out my misunderstanding. Thanks and Merry Christmas.

  • @rebrus1930
    @rebrus1930 ปีที่แล้ว +1

    Wow! You just solved an issue for me, I was just looking at it wrong, Thanks!

  • @James-mv9qx
    @James-mv9qx ปีที่แล้ว +2

    In Australia we are not allowed to do any electrical work without a licensed electrician, even changing a switch or wall socket! If you do it on your own, home insurance will not pay out if your house burns down. It's costing me about US $4000 to run single phase power about 200 feet to my shed.

    • @jefffrayer8238
      @jefffrayer8238 ปีที่แล้ว +2

      Yup, need more goverment running every little thing in our lives.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      I'd make sure my insurance company didn't know that I changed out the switch. :)

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      Yep. It took me 6 months and a variance for my county to grant me a permit to build my shed. They took $300 for the permit/variance and didn't even require an inspection. -Just big brother grabbing a piece of the action..@@jefffrayer8238

  • @effthegop
    @effthegop ปีที่แล้ว +2

    I am a retired bored EC so, here ya go :)
    1) There is no special cement for conduit. PVC is PVC. If you found a label that said for conduit, it is a marketing gimmick.
    2) You could have used the receptacle box to turn the corner into the building. You could have done the same thing at the shed to have a receptacle on the outside.
    3) There is no code to protect the wiring as it enters the PVC. That MA is much sharper than the conduit
    4) Romex (NM cable) is against code in your outside conduit. (Only a technical foul IMO)
    5) You should have pushed the short end of the UF in thru the conduit :)
    6) Although legal, unprotected cable is very vulnerable to damage. Besides rocks, gophers and moles can chew into it. It'd worth a few more dollars to run PVC all the way.
    Bottom line, the installation is good but some of your facts were wrong. :)
    Also, you don't want me to critique your terminations in the panel :)

  • @lorenmeyer5290
    @lorenmeyer5290 ปีที่แล้ว +1

    Always love watching and listening to your install April!

    • @AprilWilkerson
      @AprilWilkerson  ปีที่แล้ว

      Thanks! I'm glad you enjoy my channel. Thanks for watching.

  • @username-mc7jw
    @username-mc7jw 8 หลายเดือนก่อน

    Exactly how I ran power to my back-yard cabin. Perfect!

  • @Mikidy303
    @Mikidy303 ปีที่แล้ว +10

    I'm torn. I'm too lazy to do this myself, and I'm too cheap to pay someone to do it for me. I guess I'll keep running an extension cord to my neighbor's house until I get motivated.

    • @jefffrayer8238
      @jefffrayer8238 ปีที่แล้ว

      April really does nice work but I'll do it my way. It's just a shed, not a machine shop. Nothing that a 14ga, especially a 12 ga. extension cord can't handle. Outside house plug is Ground Fault protected so just plug it in, bury it under grass and call it good. If someone hits it with shovel nobody gets hurt because of ground fault. Extension cord would probably last 15 years but if insulation does break down ground fault shuts it off. If ya sell the place just cut cord off below ground and let next owner worry about it. Out buildings add little value, wired or not.

    • @jimmac1185
      @jimmac1185 ปีที่แล้ว

      @@jefffrayer8238 If the shovel only hit the hot wire, the GFCI would do nothing and that would still be a dangerous situation.

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน

      @@jimmac1185 no, if the hot wire is faulted the GFCI will trigger.

    • @jimmac1185
      @jimmac1185 7 หลายเดือนก่อน

      @@LG-ve9us gfci stands for ground fault circuit interruption. If there is no ground fault, there is no interruption. An AFCI would trip in this instance, but not a GFCI.
      Unless you are saying the “ground” would be contact with the dirt? Maybe, if it was really wet it might trip.
      Also, my comment was from a year ago, I don’t remember what is going on in this video and I’m not going to watch it again.

  • @richardphillips2405
    @richardphillips2405 3 วันที่ผ่านมา

    Great video. I was wondering if the open pvc in the ground would allow insects to get into the house or building.

  • @dienekes4364
    @dienekes4364 ปีที่แล้ว +2

    It would have been nice to show how you wired that into the breaker box. Once in the shed, that wire could go anywhere; into a sub-panel, into a single outlet, into a lighting setup, but wiring it into the breaker box at the source is pretty much the only option (unless, maybe, you are connecting to an existing plug?).

  • @71160000
    @71160000 ปีที่แล้ว +2

    When using an LB you always want to bring the wire into the LB through the long straight side and out the 90 degree side. Doing it backwards as you did with the first LB makes it far more difficult.

  • @felixfromnebraska8648
    @felixfromnebraska8648 ปีที่แล้ว +2

    Thank you, April. I enjoy your videos very much. They are continuously researched and demonstrated perfectly.
    Thanks for all you do in the community. Felix

  • @Aepek
    @Aepek ปีที่แล้ว +3

    4:45 haven’t finished watching the vid (so it’s possible what about to add as a tip was used)
    Another TIP for outside or anywhere using conduit or fittings or penetrating structures w/ holes and want to seal up holes for bug protection and weather……DUCT SEAL. Great stuff that has been around and used for very long time, and comes in bricks or small tubs (similar to spackle containers, but I’d pay for the brick kind as usually cost usually less when compared to amount getting, and can use in many different places and save it for future use). Also, yes, “can” fire stop and caulk the penetrations and in some areas I’d go that route, but say inside an LB, Duct Seal is what want to use, NOT any type of product that comes in caulk tube, imo, as can be difficult & messy. Also, yes, for ppl who gonna ask or want to know, can use the correct rated spray foam type material for inside electrics, fittings to seal up holes/air gaps, and then can caulk with exterior sealant etc….around the LB for more protection).
    Ok, back to the vid😁✌🏻

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      We call the stuff, "thumb gum".

  • @garageworker
    @garageworker ปีที่แล้ว +9

    You are very brave to show an electrical project on TH-cam.

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน +1

      lol, yeah all the armchair inspectors come out of the woodwork...

  • @williamwinder3466
    @williamwinder3466 ปีที่แล้ว +3

    1:25 You need to ream the inside of the pipe. The inner edge can damage the wire.

  • @donfrank4429
    @donfrank4429 ปีที่แล้ว +1

    just ran 10/2 UF to my BBQ shed in conduit into a sub panel, with 2 8 ft grounding rods

  • @raterus
    @raterus ปีที่แล้ว

    I had to do something very similar when I installed wiring to my well house during the construction of my home. I'm not an electrician, and this wasn't exactly "easy", it's just the way it has to be done! You don't want to do in-ground electrical work the wrong way though!

  • @donaldclark1019
    @donaldclark1019 ปีที่แล้ว +1

    Wiring is easy... Digging the trench is the hard part!

    • @LG-ve9us
      @LG-ve9us 7 หลายเดือนก่อน

      you should hire a professional licensed trench digger, trench digging can be dangerous. :)

  • @bobbycorrigan7969
    @bobbycorrigan7969 23 วันที่ผ่านมา

    I used direct burial to my shed. But you did good job.

  • @JohnMark1313
    @JohnMark1313 8 หลายเดือนก่อน

    It is good to check local codes. You mention the depth using pvc and a gfci but looks like you only used that to get into the trench and actually ran the UF cable by itself in the trench. Here, that would be more like 24" deep. They do sell fittings for rigid conduit that are compression so no bending or threading needed.

  • @davetuscano5939
    @davetuscano5939 7 หลายเดือนก่อน

    April,yer a Sweetie! You can bury a wire easily without digging a trench in yer backyard. Step a shovel into the ground and rock it back and forth to make a "V" groove. Lay the outdoor wire in it. And moosh it closed.

  • @DanO530.8
    @DanO530.8 20 วันที่ผ่านมา

    Ive always put the wire in each piece first especially corners or elbows then i would glue the conduit just depends on the job really and anyone’s preference.

  • @benh554
    @benh554 ปีที่แล้ว

    in a pinch for small diy wire pulling projects, liquid hand soaps works just as well

  • @ForgetU
    @ForgetU ปีที่แล้ว +4

    Put gfci inside garage and pass your wire as you did. gfci won't need waterproof box.

  • @Farmer-bh3cg
    @Farmer-bh3cg 9 หลายเดือนก่อน +1

    Just a thought: Chase the wires through the individual conduit pieces and parts before gluing the conduit. Its easier than chasing around the fixed bends, elbows and boxes.

  • @caseycooper5615
    @caseycooper5615 ปีที่แล้ว

    I've never fully understood the attraction of UF cable. If you have already dug the trench, why not use PVC the whole way? In my estimation, this allows wire to be upsized when needed without digging a new trench. Plus, UF cable is so challenging to cut and work with, not to mention its lack of mechanical protection.
    But that's my little nitpick. I appreciate how well you presented everything.

    • @SmallSpoonBrigade
      @SmallSpoonBrigade ปีที่แล้ว

      I think the only benefit is that if you have to rerun the wire, fishing it around two 90 degree angles can be a pain. But, by the same token, if you've got the wiring through properly sealed conduits the entire way, the likelihood of needing to do so is also greatly reduced.
      Also,it's worth using a bit of sand around the wire/conduit in the ground. It makes repair and replacement easier and if you decide you need a larger, conduit it's easier to remove the one you've got. Plus, it's a bit of a warning to anybody that is digging that there's this sudden unexplained sand coming up, perhaps there's a wire or a pipe down there.

  • @CliftonMoore123456789
    @CliftonMoore123456789 ปีที่แล้ว

    I would’ve purchased an extension cord long enough to go from the house to the outside shed💯😂🤣. Great video…

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      Funny you said that, Clifton. That's exactly what my next door neighbor did. :)

  • @hotpuppy1
    @hotpuppy1 ปีที่แล้ว

    If you are going to go that shallow, best to place a layer of sand over the wire then concrete patio blocks over the sand so that if anyone hits it with a shovel, they will know something is down there. Yes the GFCI will shut off the power, but who wants to go through the trouble of fixing a cut cable?

  • @kennethtomlinson9617
    @kennethtomlinson9617 ปีที่แล้ว

    Love your work, ma'am, an good to see a fellow Texan !

  • @healthywithamanda
    @healthywithamanda ปีที่แล้ว

    Found your video on Google news feed....following now because I'm wiring up my new small house and I'm tired of watching all the guys videos do it 🥴

  • @durangodave
    @durangodave ปีที่แล้ว

    you can also use a heatgun to heat the conduit and shape it how you need it. this saves stress on the straps

  • @craigyarmulasr1845
    @craigyarmulasr1845 ปีที่แล้ว

    Great video. I didn't realize how many different code's there could be. Very informative.

  • @ChristopherOBrienPSU
    @ChristopherOBrienPSU ปีที่แล้ว

    You're pretty awesome 😎. Made that look simple. I'm going to have to do this myself this summer, thanks for the tips!

  • @robertkerby2581
    @robertkerby2581 ปีที่แล้ว

    Great explanations, and another great video!
    Well done, April!

    • @AprilWilkerson
      @AprilWilkerson  ปีที่แล้ว

      Glad you liked it! Thanks for watching.

  • @adambilal42
    @adambilal42 ปีที่แล้ว +1

    all the best april
    New ideas thank you

  • @BigGuy8059
    @BigGuy8059 ปีที่แล้ว +4

    In my state, conduit can't have Romex in it. It has to be THHN individual wires. Also, PVC or direct burial Romex has to be down 20 inches, unless you have concrete above it. And you left out the part about the building inspector having to measure and approve your trench depth before you fill it in. But of course, every place can have different rules and procedures. It pays to find out your area rules.

    • @lstownley
      @lstownley ปีที่แล้ว +1

      12" depth ok for direct burial cable where ...residential...

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 หลายเดือนก่อน

      The conduit is only protecting the vertical drop at the buildings. There should be no problem with this in your area if you are using type UF Romex, like April is using. What code # indicates this?

  • @stevewilde4430
    @stevewilde4430 3 หลายเดือนก่อน

    Hi April, great video. I am wiring a new shed. When I attach my LB fitting to the outside of my home, and also the shed, and add a small length of pvc conduit to the LB fitting to get through my shed and also the rim joist of my home, can I switch over to a metal junction box on the inside of my shed and also the inside of my rim joist? From there, I would run to my breaker box for in the home. I would also run inside wire within my shed to any new outlets, switches, lights, etc. from the junction box in my shed. Thanks

  • @ryanhamilton9709
    @ryanhamilton9709 5 หลายเดือนก่อน

    I do think you are a hard worker and u r very knowledgeable on electric wiring sorry for the stupid comments I made

    • @AprilWilkerson
      @AprilWilkerson  5 หลายเดือนก่อน

      I appreciate your apology.

  • @jrpritchard1622
    @jrpritchard1622 ปีที่แล้ว

    great video thanks for sharing the tips with the pvc conduit have a great week

  • @hhazelton4391
    @hhazelton4391 10 หลายเดือนก่อน

    Keep at it April! 👍

  • @hunterscott7592
    @hunterscott7592 ปีที่แล้ว

    I do similar things on my properties…however I like to run continuous conduit in case I need to add another wire or upgrade the installed wire sometime down the line

  • @FredMcIntyre
    @FredMcIntyre ปีที่แล้ว

    Nicely done April! 😃👍🏻👊🏻