Aplus Water LLC
Aplus Water LLC
  • 43
  • 772 654
How to Access the Drain Line Flow Control (DLFC) on a Fleck 5600 Control Valve
In this video, we show you how to access the drain assembly on your Fleck 5600 style control valve. If you bought your DuraWater system from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We also try to respond to any relevant TH-cam comments in a timely manner. We love our customers!
มุมมอง: 2 096

วีดีโอ

How to Access the Injectors on Fleck 5600 Control Valve
มุมมอง 3.6Kปีที่แล้ว
In this video, we show you how to access the injectors on your Fleck 5600 style control valve. It is important to clean these components out once or twice a year depending on the amount of iron you have in the water. If you bought your DuraWater system from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmai...
How to Remove the Fleck 5600 SXT Circuit Board
มุมมอง 474ปีที่แล้ว
This is how you remove the circuit board from a Fleck 5600 SXT.
How to Install the Fleck 5600 SXT Water Softener
มุมมอง 37K2 ปีที่แล้ว
In this video, we show you how to install your brand new Fleck 5600 SXT water softener. If you bought your DuraWater water softener from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We also try to respond to any relevant TH-cam comments in a timely...
How to Rebuild the Fleck 5600 Control Valve
มุมมอง 12K2 ปีที่แล้ว
In this video, we show you how to rebuild your Fleck 5600 control valve. This rebuild consists of replacing the main piston, seals, and spacers. This process is the same for all 5600 control valves (digital and mechanical softeners, air injection systems, and filter only systems). Depressurization video link: th-cam.com/video/hCWQYWSjt50/w-d-xo.html (Please note this is for an SXT control valve...
Fleck 5600 SXT Air Injection Programming Video
มุมมอง 10K2 ปีที่แล้ว
In this video, we show you how to program your 5600 SXT Air Injection control valve. If you bought your DuraWater air injection Iron Eater from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We love our customers! We also try to respond to any releva...
Fleck 5600 SXT Water Softener Programming Video
มุมมอง 35K2 ปีที่แล้ว
In this video, we show you how to program your 5600 SXT Water Softener control valve. If you bought your DuraWater water softener from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We love our customers! We also try to respond to any relevant TH-cam...
DuraWater, By Aplus Water LLC
มุมมอง 2542 ปีที่แล้ว
Hi! We're Aplus Water. With over 50 combined years of experience in the water treatment industry, our customer service and support is second-to-none. Our DuraWater whole house water softeners are available in many different sizes and styles to fit your exact needs by utilizing a variety of control valves, including our bestseller the Fleck 5600SXT, as well as different media options. Our chemic...
DuraWater On-Demand Metered Water Softener
มุมมอง 7942 ปีที่แล้ว
The Durawater whole house on demand metered Water Softener, by Aplus Water LLC. Here at Aplus Water, we pride ourselves in customer service. We promise to be just as helpful before the sale as we will be after the sale so, please reach out to us with any questions. We love to help our customers! Call us toll-free Monday through Friday 9am-4pm CST at 877-477-5452 or reach out through email at ap...
How to Depressurize a Fleck 5600 SXT Control Valve
มุมมอง 19K3 ปีที่แล้ว
In this video we show you how to safely disconnect your softener from your plumbing. Please remember, while reconnecting your plumbing, do NOT overtighten the screws, as this can cause damage. If you still have any remaining questions, please don’t hesitate to reach out to us! You can call us toll free Monday through Friday from 9am to 4pm CST at 877-477-5452. You can also email us at apluswate...
Fleck 5600SXT Metered Softener Installation Video Specials
มุมมอง 49K5 ปีที่แล้ว
Fleck 5600SXT Metered Softener Installation Video Specials
*New* Special 5600SXT Metered Softener Installation Video
มุมมอง 3.1K5 ปีที่แล้ว
*New* Special 5600SXT Metered Softener Installation Video
Upflow Calcite Filter Installation Video
มุมมอง 1.4K6 ปีที่แล้ว
Upflow Calcite Filter Installation Video
Upflow Calcite Filter Installation Video
มุมมอง 2.6K6 ปีที่แล้ว
Upflow Calcite Filter Installation Video
Upflow Carbon Filter Installation Video
มุมมอง 3.8K6 ปีที่แล้ว
Upflow Carbon Filter Installation Video
Upflow Carbon Filter Installation Video
มุมมอง 3.1K6 ปีที่แล้ว
Upflow Carbon Filter Installation Video
Fleck 5600 SXT Softener Installation Video BB
มุมมอง 41K6 ปีที่แล้ว
Fleck 5600 SXT Softener Installation Video BB
Fleck 5600 SXT Softener Installation Video BB
มุมมอง 15K6 ปีที่แล้ว
Fleck 5600 SXT Softener Installation Video BB
5600 SXT Air Injection Filter Installation Video
มุมมอง 35K6 ปีที่แล้ว
5600 SXT Air Injection Filter Installation Video
Fleck 9100 SXT Installation Video
มุมมอง 3.7K6 ปีที่แล้ว
Fleck 9100 SXT Installation Video
DuraWater Water Softener Installation PL
มุมมอง 1.1K6 ปีที่แล้ว
DuraWater Water Softener Installation PL
DuraWater Installation Water Softener SS
มุมมอง 2K6 ปีที่แล้ว
DuraWater Installation Water Softener SS
DuraWater Softeners - Free Shipping - Whole House Filter
มุมมอง 2067 ปีที่แล้ว
DuraWater Softeners - Free Shipping - Whole House Filter
DuraWater Line Water Softeners
มุมมอง 2647 ปีที่แล้ว
DuraWater Line Water Softeners
Duraline Well Water Softener
มุมมอง 4117 ปีที่แล้ว
Duraline Well Water Softener
Air Injection Iron Eater Video
มุมมอง 2.9K7 ปีที่แล้ว
Air Injection Iron Eater Video
Iron Blaster
มุมมอง 1.6K7 ปีที่แล้ว
Iron Blaster
Air Injection Iron Eater
มุมมอง 21K7 ปีที่แล้ว
Air Injection Iron Eater
DuraWater City Softener
มุมมอง 1317 ปีที่แล้ว
DuraWater City Softener
DuraWater Line Water Softeners
มุมมอง 3127 ปีที่แล้ว
DuraWater Line Water Softeners

ความคิดเห็น

  • @ivandimeo4840
    @ivandimeo4840 14 วันที่ผ่านมา

    I programmed the water softener, I chose gallons as the unit of measurement, at the end of the programming is the value on the water consumption display gallons or liters? Thanks for the explanations.

    • @AplusWaterLLC
      @AplusWaterLLC 13 วันที่ผ่านมา

      With the Display Format set to Gal, the number of the consumption is in gallons! Hope that helps!

    • @ivandimeo4840
      @ivandimeo4840 12 วันที่ผ่านมา

      ​@@AplusWaterLLC thank you so much!

  • @allenpartyof6
    @allenpartyof6 16 วันที่ผ่านมา

    My Iron test reads 0.03 mg/l so do i add 15 to the H parameter (.03x5) or is 0.03 not even considered a 1. TIA

  • @eddiecedillos8417
    @eddiecedillos8417 หลายเดือนก่อน

    Thank you very much. Amazing video

  • @dnycrane
    @dnycrane หลายเดือนก่อน

    What setting can i adjust that has the most effect on softness, I want the water softer than the "normal" settings for a 48K capacity system.

  • @taylorflowers4598
    @taylorflowers4598 หลายเดือนก่อน

    I have a 5600sxt. Flow rate was 0.0 per diagnostic check, so I just cleaned out the control valve assembly and made sure there were no built-up iron deposits remaining. I put it back together and, still, flow rate is 0.0. When I turn a faucet on, the flow indicator (water droplet icon) does not show up, and the "gallons remaining" number does not change. I can successfully run a regeneration cycle and everything works (brine draw, fill, etc., with a good float assembly). What is my next step? I think the control valve assembly is in good shape.

  • @stierbyku4922
    @stierbyku4922 หลายเดือนก่อน

    Good day, I have a problem with my Fleck 5600sxt, it does not count water consumption and therefore cleaning does not start. What could it be? Have you encountered such a problem? I would be grateful for any information. Best regards, Marek

  • @Nena800
    @Nena800 หลายเดือนก่อน

    DIYer here...Thank you for these videos!!!

  • @holdentasillo588
    @holdentasillo588 2 หลายเดือนก่อน

    Will this Fleck 5600 SXT Air Injection Iron Eater Filter work for removing colloidal iron?

  • @gauravagru1
    @gauravagru1 2 หลายเดือนก่อน

    Do you recommend adding lubricants to seals and spacers ?

  • @balaspbponnusamy8592
    @balaspbponnusamy8592 2 หลายเดือนก่อน

    Excellent video 👍👍👍

  • @vanessarizio8414
    @vanessarizio8414 3 หลายเดือนก่อน

    Our instructions say to connect the incoming water to the DOWNFLOW inlet.

  • @CD318
    @CD318 3 หลายเดือนก่อน

    Good job

  • @pefferie
    @pefferie 3 หลายเดือนก่อน

    Wgere can I buy these 1" supply hoses?

  • @latourbrian
    @latourbrian 3 หลายเดือนก่อน

    Thanks for posting these videos, it taught me a lot. But... I followed all the steps in both videos and no luck. When i had the drain flow button out, I did get draw. I changed the brine valve for like $15, still no luck. All the parts in the backwash injector assembly were very clean even when i first opened it up. So I ended up buying the main piston assembly with seals and spacers for $70. I honestly didn't think it would work. It did. I have brine draw again. So if you try all the tips and still get water flowing out to the salt tank during BD, as a last resort I'd suggest a new main valve. BTW, my main piston a green top and the one i bought from amz was white... it worked fine. Maybe i'm missing something there, but it just seems ok.

  • @destroyingtheworksofthedev9349
    @destroyingtheworksofthedev9349 4 หลายเดือนก่อน

    Hi my brine tank seems to be low as in the level. For instance the level is sitting like 2 feet below the release valve, is this normal?

  • @rodneysanborn3183
    @rodneysanborn3183 5 หลายเดือนก่อน

    On the turbine, / paddle setting, I have neither, I just bought the 5600, I have no other attachments, what would my setting be? And are any other settings I should know?

  • @blockfather1375
    @blockfather1375 5 หลายเดือนก่อน

    I followed these settings but my air injection head unit still spits water out of the air port before RR and then at the end before brine fill. brine fill is set to OFF and I now have all the settings the same as described in the video. any thoughts on why it insists on spewing out water for a few seconds at the start and maybe 15-30 seconds at the end of the cycle? thanks

  • @RomanKocherovsky
    @RomanKocherovsky 5 หลายเดือนก่อน

    is the guy doing the demo Marc Ribillet 😁. Also, very helpful video.

  • @stephensaenz463
    @stephensaenz463 6 หลายเดือนก่อน

    How do you turn it on

  • @trevorrussell7679
    @trevorrussell7679 6 หลายเดือนก่อน

    Maybe a silly question, but is it possible to back-flush/drain back into the well itself? My system is not near my septic and I know it’d be putting debris back down, but didn’t know if it would be rough to filter back through or not.. also how many gallons does the backflush typically use?

  • @wsurfer2147
    @wsurfer2147 6 หลายเดือนก่อน

    Thanks for the video, What to do if the controll valve electronic no longer function (broken) ?

    • @AplusWaterLLC
      @AplusWaterLLC 6 หลายเดือนก่อน

      If the system is unable to be regenerated, you'll need to depressurize the entire home. To do this, you'll want to shut the main water off and run a faucet until there is no water left. Hope that helps! -Aplus Water

    • @wsurfer2147
      @wsurfer2147 6 หลายเดือนก่อน

      @@AplusWaterLLC Thank you for the info. I have another question. My 5600 sxt screen is dead, I change the 24vac power supply but that didn't help. Is the controll board bad?

    • @AplusWaterLLC
      @AplusWaterLLC 6 หลายเดือนก่อน

      @@wsurfer2147 If replacing the transformer did not help, there is a good chance that the circuit board is to blame for no power to the valve. (assuming the outlet that the system is plugged into is working properly)- Aplus Water

    • @wsurfer2147
      @wsurfer2147 6 หลายเดือนก่อน

      @@AplusWaterLLC Thank you. I replaced the transformer but it also died. Because i think there is a short somewhere in the controll head. The original tramsformer died. I did check the outlet by plugging a light and it was fine.

  • @Partsunknown426
    @Partsunknown426 6 หลายเดือนก่อน

    Is this a 9 x 48 tank? is that why a 40 min air draw? plus does the air draw push most of the water out of the tank in that time?

  • @pkdude5334
    @pkdude5334 6 หลายเดือนก่อน

    should the softener or AIO be regenerated first? does it matter?

    • @AplusWaterLLC
      @AplusWaterLLC 6 หลายเดือนก่อน

      Hi, It does not matter at all which one regenerates first, they just cannot regenerate at the same time! -Aplus Water

  • @stapler40
    @stapler40 6 หลายเดือนก่อน

    What is the lifespan of the 5600sxt? I ask because I currently have one installed in my home, which is about 15 years old. So, how does one determine the condition of the unit. I've never had any errors with the unit in 15 years, but is it time to swap out for a new 5600sxt. If I do decide to swap out, should I buy the entire device, or do you think I would only need a tank? Thank you for any help you can provide.

    • @AplusWaterLLC
      @AplusWaterLLC 6 หลายเดือนก่อน

      Hi! It really depends on water quality and water usage for how long a system may last. The only way to know it is time for a new one is when the old one goes out on you. If your current system is running fine, there's no reason to upgrade just yet. Whether you buy a complete new system or just new resin is up to you! There are benefits to both, such as new warranties on a new system or saving on cost by doing just resin. Feel free to give us a call and pick our brains regarding your situation. We are happy to help!- Aplus Water

  • @logikalx
    @logikalx 7 หลายเดือนก่อน

    Thanks for the video, I saw my tank was full and just hit regen in panic. So that did nothing but while it was trying to do its thing i was able to pull the float system and syphon almost all of the water from the brine tank, so even if its not fixed at least it wont overflow before I can get a technician out!

  • @duckhunter8387
    @duckhunter8387 7 หลายเดือนก่อน

    Well done!

  • @freddyrojas6956
    @freddyrojas6956 7 หลายเดือนก่อน

    Any chance to get a model 9500 programming help

  • @felixandanavelazquez9245
    @felixandanavelazquez9245 7 หลายเดือนก่อน

    I have the same unit that the clock is set to 24 hours instead of 12. How I can change to 12 hours.( I can not see the pm icon)

    • @AplusWaterLLC
      @AplusWaterLLC 7 หลายเดือนก่อน

      It sounds like the display format on your system is set to Liters instead of gallons. You will just set the clock to 12:01 and hold both arrow buttons down until DF LTR pops up. Change this setting to DF GAL and the clock will read in gallons and the 12 hour clock. Give us a call if you're still having issues!- Aplus Water

  • @johna.ludwig2311
    @johna.ludwig2311 7 หลายเดือนก่อน

    First of all, thank you for making it clear about the 12:01.......I tried with the correct time of day with no success. The rest is programmed ok but how do you program the NUMBER OF GALLONS BEFORE REGENERATON? Mine just has four dashes. - - - - What does that mean and how do I program it?

    • @AplusWaterLLC
      @AplusWaterLLC 7 หลายเดือนก่อน

      The number of gallons should automatically be configured based on the capacity of the system, the hardness of the system, and the reserve setting. If you have the hardness cranked way up and the capacity set way low, you will experience the dashes. I would double check that your settings are set accurately. If you are still struggling, give us a call! - Aplus Water

  • @zachhopkins9719
    @zachhopkins9719 8 หลายเดือนก่อน

    Thank you very much!!! Took a while to find your video. Everyone else was telling me to flow out lines that are probably blocked. Did two regular regeneration without using a shop vac to suck out the water to be below the float. I have three tanks total, two control heads but I believe the one that looks most similar to yours is a double unit and step 2 is brine/rinse. Jumped to that and see movement down in the brine well which I wasn’t getting before. Might not be fixed but thanks for providing an alternative troubleshooting method that sounds like I should have tried first if it’s that common

  • @HooverFamily-nn8di
    @HooverFamily-nn8di 8 หลายเดือนก่อน

    Can you replace the manual valve control with a digital one?

    • @AplusWaterLLC
      @AplusWaterLLC 8 หลายเดือนก่อน

      Hi! Yes! Most of the time, replacing a mechanical valve with a digital valve is an easy, direct swap. - Aplus Water

  • @ajeshrama2419
    @ajeshrama2419 8 หลายเดือนก่อน

    During the last four years, we have had no problems with the same model, but now we are experiencing continuous drain, and softener tank is completely empty, would it be possible for you to suggest any solutions?

    • @AplusWaterLLC
      @AplusWaterLLC 8 หลายเดือนก่อน

      Hi! Continuous leak to the drain is usually a red flag that the main piston seals of the valve are either worn down or compromised by debris. Once you replace/clean those seals, you should be back to normal operation. Hope that helps! - Aplus Water

    • @ajeshrama2419
      @ajeshrama2419 8 หลายเดือนก่อน

      @@AplusWaterLLC thank you brother

  • @k50159
    @k50159 8 หลายเดือนก่อน

    Much appreciated

  • @jimrudenberg6099
    @jimrudenberg6099 8 หลายเดือนก่อน

    Thanks, This worked well! Very thankful.

  • @joeala762
    @joeala762 9 หลายเดือนก่อน

    What if don't know how hard your water is?

  • @matjusz8985
    @matjusz8985 9 หลายเดือนก่อน

    Can I adjust the hardness later on?

    • @AplusWaterLLC
      @AplusWaterLLC 9 หลายเดือนก่อน

      Hi! You can always go back and adjust the hardness in the programming!

  • @3rdBNDeltaCo
    @3rdBNDeltaCo 9 หลายเดือนก่อน

    What size are the O-rings?

  • @robertmartin4780
    @robertmartin4780 9 หลายเดือนก่อน

    Please, this is a good video telling me nearly all I need to know. But what precisely should I see inside the tank before, during and after changing the media. If the time has come to change and I shine my light will I see a residual level of calcite or am I seeing internal tank structure? What am I actually seeing when the tank appears to have some calcite in it up to about a foot from the bottom? How much water should I remove before adding more calcite? Just above the shadow of existing calcite? Fill with new calcite to within six inches from top of tank? Thanks much. I'm about to service my filter in my crawl space and want to be assured of the proper procedure.

  • @FiveMinutesWithATechnician
    @FiveMinutesWithATechnician 9 หลายเดือนก่อน

    Why do you not recommend using the smaller mesh screen in the brine line kit? 9:31

    • @AplusWaterLLC
      @AplusWaterLLC 9 หลายเดือนก่อน

      Great question! We notice they tend to get clogged pretty easily causing a loss of pressure through the system. It just ends up being a hassle to clean it out every so often rather than just leaving it out. Hope that helps!!- Aplus Water

  • @aquariuswithfire
    @aquariuswithfire 10 หลายเดือนก่อน

    Do these units require periodic maintenance and is so how often? TY Great Vid BTW!

    • @AplusWaterLLC
      @AplusWaterLLC 10 หลายเดือนก่อน

      Hi! We recommend periodically cleaning the injectors and the drain line flow control washers. If you have iron in the water, we recommend this about once a year or so. We have videos on how to access these as well on our channel! Glad to hear you're enjoying the videos! Thanks! -Aplus Water

  • @christophe3281
    @christophe3281 10 หลายเดือนก่อน

    Is the turbine valve necessary if it’s an AIO that recharges every 3 days anyway?

    • @AplusWaterLLC
      @AplusWaterLLC 10 หลายเดือนก่อน

      Hi! An air injection system will not use a meter. It runs strictly on the day override setting. Hope that helps! -Aplus Water

    • @christophe3281
      @christophe3281 10 หลายเดือนก่อน

      @@AplusWaterLLC thanks for the reply!

  • @snipex111
    @snipex111 10 หลายเดือนก่อน

    Should i depressurize and bypass when going on vacation?? Say 7 days ?

    • @AplusWaterLLC
      @AplusWaterLLC 10 หลายเดือนก่อน

      Hi, If you're only going to be gone for a while, just unplug the system from the outlet. This will prevent it from regenerating while you're gone. No need to depressurize or bypass the system! Whenever you get back, you'll just plug the valve back in and reset the time of day. The programming will remain indefinitely for you. Hope that helps! - Aplus Water

    • @snipex111
      @snipex111 10 หลายเดือนก่อน

      Yes thank you

  • @paulh6591
    @paulh6591 10 หลายเดือนก่อน

    Does Fleck sell a wrench to remove the head assembly? I have an oler model, and even after releasing pressure, it's on too tight to unscrew by hand.

    • @AplusWaterLLC
      @AplusWaterLLC 10 หลายเดือนก่อน

      Unfortunately there are no wrenches to remove the valve. It sounds like yours may have been overtightened when it was installed. Most of the time, the valve unscrews fairly easily by hand. I would say keep trying your best, but be very careful not to damage the threads of the tank! If the threads are damaged you'll need a whole new tank. If you end up installing a new valve (or reinstalling your old one), be sure to only put the valve on until it is snug and secure. Also, be sure to not use any sort of pipe dope or teflon tape on this connection. A little lubricant and some elbow grease should get the valve on just tight enough to have a secure connection without making it impossible to remove the valve in the future.- Aplus Water

    • @paulh6591
      @paulh6591 10 หลายเดือนก่อน

      @@AplusWaterLLC Thanks- maybe I'll use a strap wrench. That Fleck 5600 SXT digital head you have here... would it be a direct swap for my old motor-drived 14-day Fleck brine unit unit, so I can keep the old tank, which still looks good? The old Fleck had developed a hairline weep leak, I'm tired of hearing the little clock driver motor, and the unit hasn't been serviced for years so I need new beads anyway. While I'm at it I'd like to update the head unit. My other option would be to not use a softener- I've had this one on bypass for the last few months, now I'm toying with discarding/gifting it or fixing it up.

    • @pefferie
      @pefferie 3 หลายเดือนก่อน

      I stick a scrap of copper pipe into an inlet port for leverage

  • @christophe3281
    @christophe3281 10 หลายเดือนก่อน

    Are the valve heads interchangeable for a softener to an aio? For example, could you use the 5600sxt softener valve for an aio if you reconfigure the program and add a check valve where the brine draw would connect?

    • @AplusWaterLLC
      @AplusWaterLLC 10 หลายเดือนก่อน

      Hi, The valves are built very similarly, but to convert the softener valve to an air injection valve, you would need to reconfigure the programming, add a check valve where the brine line connection is, replace the flow controls to suit the difference between the softener resin and the filter media, and add a check valve to the inlet side of the valve (to make sure your air pocket does not escape). A lot of times, it ends up being fairly close (if not better) in price to buy a brand new system than try to convert everything over. Hope that helps!- Aplus Water

  • @christophe3281
    @christophe3281 10 หลายเดือนก่อน

    Is this the same type of valve that’s used for an air injector for iron filters as well as softeners?

  • @scottcarter9975
    @scottcarter9975 10 หลายเดือนก่อน

    I am so confused! On the hardness setting. Our hardness is 2.5 grains per gallon. I understand that three is the maximum you want. Our iron is 0.15 ppm. I understand that 0.3 is the maximum healthy. These numbers are so different from your description. Am I misunderstanding something? Thanks.

  • @JamesDThomas1981
    @JamesDThomas1981 10 หลายเดือนก่อน

    Excellent video. I had to disconnect my water softener so I can get my garage floors painted. So when I went to go put the water softener back in I need a directions on how to set up. The best I've seen thus far.

  • @MarkPeterson-u2x
    @MarkPeterson-u2x ปีที่แล้ว

    Had the 64,000 unit, it has run 2 cycles since it was installed about 3-4 weeks ago, last cycle a couple days ago. Level fills to about 1100, now down to 90 in 2 days, also says "rc" with blinking water faucet, what's going on? Of course always on weekend when you can't call anyone.

    • @AplusWaterLLC
      @AplusWaterLLC 11 หลายเดือนก่อน

      Hi, "rc" stands for reserve capacity. This means you are currently using the reserve of soft water that the system has built in through the programming. This is just to ensure you do not run out of soft water halfway through the day. When you see "rc" a regeneration gets queued up to occur later that night, hence why you see the blinking water faucet. 1100 gallons down to 90 in 2 days is really quick. This could be correct if there are a lot of people using the water. If you haven't already, though, I would double check that the programmed settings are correct and your hardness number is accurate. If everything looks accurate and you don't have a ton of water usage, check for leaks throughout the home (possibly a leaky toilet or something like that). We are in the office Monday - Friday 9am-4pm CST. Give us a call if you are still having issues! - Aplus Water

  • @wilholland100
    @wilholland100 ปีที่แล้ว

    Question, My plunger on my Aquasure system is very stiff and doesn't want to move up and down. It is a fairly new system. I'm afraid it is so stiff that it may break the plastic wheel. How easily should they move up and down?

    • @SomeGuysGarage
      @SomeGuysGarage 2 หลายเดือนก่อน

      Have this same concern...

  • @DavidPickwell-f9p
    @DavidPickwell-f9p ปีที่แล้ว

    You skipped an important setup step there bud. You set the people thing, but left out the gallons of capacity setting from the Clarke Chart. Should have set dial ring to 14 gal, lined up with the white dot there (based on the 4 people and 20 hardness) --- you left the gallons of capacity at 9 gal, not right. You don't know what you are doing.