![Shishiram Engineering Services](/img/default-banner.jpg)
- 166
- 2 807 382
Shishiram Engineering Services
India
เข้าร่วมเมื่อ 21 เม.ย. 2020
Hi, I'm Amrut Shishir. The Electrical Engineer. Welcome To my channel! In this channel, I'm trying to help students, engineers and like-minded people to learn technical engineering topics through short, simplified tutorials videos. Our goal is to be the number one resource and online learning tool for all aspects of electrical engineering.
Shishiram Engineering Services is a distinguished engineering service company providing engineering & project management services to various industrial segments. Presently we specialize in Electrical Engineering Consultancy Service, Electrical Contracting Service, Electrical Chartered Engineering Service, Switchgear Panels LT/HT Designing, Fabrication, Installation, and Commissioning Service, Electrical Maintenance Industrial & Commercial Service, Electrical Approval & Liaisoning Services. We have an expert team of Engineers and Technicians with Substantial Experience and International Exposure.
Shishiram Engineering Services is a distinguished engineering service company providing engineering & project management services to various industrial segments. Presently we specialize in Electrical Engineering Consultancy Service, Electrical Contracting Service, Electrical Chartered Engineering Service, Switchgear Panels LT/HT Designing, Fabrication, Installation, and Commissioning Service, Electrical Maintenance Industrial & Commercial Service, Electrical Approval & Liaisoning Services. We have an expert team of Engineers and Technicians with Substantial Experience and International Exposure.
Why Don't We Get an Electric Shock While Wearing Footwear? | Will ELCB Trip in That Case?
In this video, I explain why we don't typically get an electric shock while wearing footwear and whether an ELCB (Earth Leakage Circuit Breaker) will trip in such situations. Discover the science behind electrical safety and protective measures.
Topics Covered:
Why we don’t get an electric shock while wearing footwear?
How ELCB works?
When ELCB will trip?
Detailed Explanation:
Footwear acts as an insulator, preventing the flow of electricity through our bodies. When we come into contact with a live wire or an electrical fault, the insulation provided by the footwear often prevents us from feeling an electric shock. However, if we do experience an electric shock, the electron flow is usually insufficient to cause a significant current that would trip the ELCB. An ELCB is designed to detect and interrupt current leakage to the ground, but in cases where the current is minimal and doesn't flow through the ground, it may not trip.
If you need MEP (Mechanical, Electrical, and Plumbing) drawings for your residential or commercial projects, contact us at Shishiram Engineering Services. We provide expert MEP solutions to meet your needs.
📞 Contact us: +918606472279
🌐 Visit our website: www.shishirameng.com
Topics Covered:
Why we don’t get an electric shock while wearing footwear?
How ELCB works?
When ELCB will trip?
Detailed Explanation:
Footwear acts as an insulator, preventing the flow of electricity through our bodies. When we come into contact with a live wire or an electrical fault, the insulation provided by the footwear often prevents us from feeling an electric shock. However, if we do experience an electric shock, the electron flow is usually insufficient to cause a significant current that would trip the ELCB. An ELCB is designed to detect and interrupt current leakage to the ground, but in cases where the current is minimal and doesn't flow through the ground, it may not trip.
If you need MEP (Mechanical, Electrical, and Plumbing) drawings for your residential or commercial projects, contact us at Shishiram Engineering Services. We provide expert MEP solutions to meet your needs.
📞 Contact us: +918606472279
🌐 Visit our website: www.shishirameng.com
มุมมอง: 233
วีดีโอ
MCB & Cable Size Selection for Home Wiring | വീട്ടിലേക്ക് MCB & Cable Size എങ്ങനെ സെലക്ട് ചെയ്യാം?
มุมมอง 2.1K28 วันที่ผ่านมา
Ensure your home’s electrical system is safe and efficient by selecting the right MCB (Miniature Circuit Breaker) and cable size. This video covers: 🔑 Key Topics: Types of MCBs: Overview of various MCB types. Cable Size Calculation: Simple steps for choosing the correct cable size. Installation Tips: Best practices for a secure setup. നിങ്ങളുടെ വീടിനായി ശരിയായ MCB & കേബിൾ സൈസ് എങ്ങനെ തിരഞ്ഞെടുക...
Iron Box Socket Without Earthing: Does RCCB Offer Protection?
มุมมอง 565หลายเดือนก่อน
In this video, we explore a critical safety question: Does an RCCB (Residual Current Circuit Breaker) protect us when using an iron box socket without earthing? ▬ Contents of this video ▬▬▬▬▬▬▬▬▬▬ 0:00 - Intro: Iron Box Socket Without Earthing 0:40 - RCCB Basics 1:40 - Earthing protects 2:20 - Does RCCB Offer Protection? 2:50 - Safety Precautions 3:02 - Conclusion 🔍 What You'll Learn: RCCB Func...
🔌Why Didn't RCCB Trip During a Short Circuit? ഒരു ഷോർട്ട് സർക്യൂട്ടിനിടെ RCCB ട്രിപ്പ് ചെയ്യാത്തത്?
มุมมอง 523หลายเดือนก่อน
If you’ve ever been puzzled by why your Residual Current Circuit Breaker (RCCB) didn’t trip during a short circuit, you’re not alone! 🤔 Short circuits are serious hazards, and an RCCB is crucial for protection. In this video, we’ll dive deep into the reasons behind this issue and how you can ensure your safety. Here's what we'll cover: ▬ Contents of this video ▬▬▬▬▬▬▬▬▬▬ 0:00 - Intro: why RCCB ...
Electrical Masterclasses Journey from Beginner to Industrial Pro | Malayalam Electrical Class
มุมมอง 8K2 หลายเดือนก่อน
Join our course click the link to know more: bit.ly/3R2cYxN Join us as we guide you from the basics of electrical engineering to mastering advanced industrial applications. Our comprehensive masterclasses offer step-by-step tutorials, real-life examples, and expert insights to transform you from a beginner to an industrial pro in the captivating realm of electrical engineering. Don't miss out o...
OBO Surge Protection Device How To Fix SPD Unboxing & Installation Guide Type 1 & 2 SPDs
มุมมอง 2K7 หลายเดือนก่อน
For more information on OBO SPD Contact Number: 91 9846825655 🔒 Safeguard your electronics with our latest video! Join us in unboxing the cutting-edge OBO Surge Protection Device (SPD) and master the art of installation for both Type 1 and Type 2 SPDs. Whether you're a DIY enthusiast or a professional electrician, this step-by-step guide will ensure your devices stay protected from voltage surg...
"🌼 Embrace the vibrant colors of Onam with Shishiram Engineering Services! 🌼
มุมมอง 61311 หลายเดือนก่อน
"🌼 Embrace the vibrant colors of Onam with Shishiram Engineering Services! 🌼 Wishing you all a joyful and prosperous Onam celebration. May this harvest festival bring abundance and happiness to your lives. 🌾🌟 #OnamCelebration #ShishiramEngineering #FestiveGreetings"
Havells MCCB Shunt Coil Connection | Why Micro Switch in Shunt Coil | How to Install | How it works
มุมมอง 1.2Kปีที่แล้ว
Havells MCCB Shunt Coil Connection | Why Micro Switch in Shunt Coil | How to Install | How it works
How to Install Shunt Coil In L&T MCCB | How to Trip MCCB in Auto mode | Why we need MCCB Shunt Coil
มุมมอง 3.2Kปีที่แล้ว
How to Install Shunt Coil In L&T MCCB | How to Trip MCCB in Auto mode | Why we need MCCB Shunt Coil
Home Automation Malayalam Kerala | ഹോം ഓട്ടോമേഷൻ വീട് പണിയുമ്പോൾ എന്തൊക്കെയാണ് ശ്രെദ്ധിക്കേണ്ടത്.
มุมมอง 7Kปีที่แล้ว
Home Automation Malayalam Kerala | ഹോം ഓട്ടോമേഷൻ വീട് പണിയുമ്പോൾ എന്തൊക്കെയാണ് ശ്രെദ്ധിക്കേണ്ടത്.
MEP & Electrical Drawing Layout For Residential Building | MEP Design & Electrical Drawings For Home
มุมมอง 4.7Kปีที่แล้ว
MEP & Electrical Drawing Layout For Residential Building | MEP Design & Electrical Drawings For Home
How to Do Electrical & Plumbing Drawings & Designs | Why We Need Electrical Drawings & MEP Designs
มุมมอง 4.6Kปีที่แล้ว
How to Do Electrical & Plumbing Drawings & Designs | Why We Need Electrical Drawings & MEP Designs
Electrical Consultancy Service | Shishiram Engineering Services | Amrut Shishir Mohanan | MEP Design
มุมมอง 3.9Kปีที่แล้ว
Electrical Consultancy Service | Shishiram Engineering Services | Amrut Shishir Mohanan | MEP Design
Neutral Cut-Off & High Voltage Issue | Protection from High Voltage Issue | 3 Methods Save Your Home
มุมมอง 1.8Kปีที่แล้ว
Neutral Cut-Off & High Voltage Issue | Protection from High Voltage Issue | 3 Methods Save Your Home
How to Do Piping & Wiring for a TV | Laying Conduit Pipe for TV Without Showing Wires | Home Wiring
มุมมอง 857ปีที่แล้ว
How to Do Piping & Wiring for a TV | Laying Conduit Pipe for TV Without Showing Wires | Home Wiring
DP Switches | Double Pole Modular Switches | Why & What all loads need DP Switches | Isolation
มุมมอง 1.2Kปีที่แล้ว
DP Switches | Double Pole Modular Switches | Why & What all loads need DP Switches | Isolation
ഇലക്ട്രീഷ്യൻ നല്ലതാണെങ്കിൽ ഇലക്ട്രിക്കൽ ഡ്രോയിങ്ങിന്റെ ആവശ്യമുണ്ടോ? Electrical Drawings for Home
มุมมอง 12Kปีที่แล้ว
ഇലക്ട്രീഷ്യൻ നല്ലതാണെങ്കിൽ ഇലക്ട്രിക്കൽ ഡ്രോയിങ്ങിന്റെ ആവശ്യമുണ്ടോ? Electrical Drawings for Home
Earthing, Grounding & Neutral | Structural Earthing | Equipment Earthing | Equipotential Bonding
มุมมอง 1.8Kปีที่แล้ว
Earthing, Grounding & Neutral | Structural Earthing | Equipment Earthing | Equipotential Bonding
What Is Fuse Wire? Can We Use Soldering Wire in Fuse? സോൾഡറിംഗ് വയർ, ഫ്യൂസ് വയർ എന്നിവ ഒന്നാണോ?
มุมมอง 1.3Kปีที่แล้ว
What Is Fuse Wire? Can We Use Soldering Wire in Fuse? സോൾഡറിംഗ് വയർ, ഫ്യൂസ് വയർ എന്നിവ ഒന്നാണോ?
Can We Use 0.75mm Wire For LED Lights | House Wiring With 0.75mm Safe | 0.75mm Wire ഉപയോഗിക്കാമോ?
มุมมอง 1.6Kปีที่แล้ว
Can We Use 0.75mm Wire For LED Lights | House Wiring With 0.75mm Safe | 0.75mm Wire ഉപയോഗിക്കാമോ?
How to balance 3 phase load in a house? | ഒരു വീട്ടിൽ ലോഡ് എങ്ങനെ ബാലൻസ് ചെയ്തുകൊണ്ട് വയർ ചെയ്യാം
มุมมอง 3.1Kปีที่แล้ว
How to balance 3 phase load in a house? | ഒരു വീട്ടിൽ ലോഡ് എങ്ങനെ ബാലൻസ് ചെയ്തുകൊണ്ട് വയർ ചെയ്യാം
Class 2 & Class 5 വയറുകൾ ഒരുമിച്ച് ഉപയോഗിക്കാമോ? | Can We Use Aluminum & Copper Cable Together
มุมมอง 1.1Kปีที่แล้ว
Class 2 & Class 5 വയറുകൾ ഒരുമിച്ച് ഉപയോഗിക്കാമോ? | Can We Use Aluminum & Copper Cable Together
Whether Earthing Copper Conductor to Be Concealed or Not? PVC Conduit Needed for Earthing Wire
มุมมอง 946ปีที่แล้ว
Whether Earthing Copper Conductor to Be Concealed or Not? PVC Conduit Needed for Earthing Wire
Plug Socket എന്തുകൊണ്ടാണ് കരിയുന്നത്? Why Plug Socket Get Burned | Problems & Solution | Malayalam
มุมมอง 1.7Kปีที่แล้ว
Plug Socket എന്തുകൊണ്ടാണ് കരിയുന്നത്? Why Plug Socket Get Burned | Problems & Solution | Malayalam
Changing Single Phase Line to 3 Phase to Get Continuous Power Supply | Phase Selector Good or Bad
มุมมอง 680ปีที่แล้ว
Changing Single Phase Line to 3 Phase to Get Continuous Power Supply | Phase Selector Good or Bad
How to Select Generator Size For Shop | ചെറിയ കടയ്ക്ക് ഏത് ജനററ്റർ വേണം | Generator for Small Shops
มุมมอง 975ปีที่แล้ว
How to Select Generator Size For Shop | ചെറിയ കടയ്ക്ക് ഏത് ജനററ്റർ വേണം | Generator for Small Shops
How to Connect Earth to SPD | Earthing Guide for Surge Protection Device | No Separate Earth For SPD
มุมมอง 13Kปีที่แล้ว
How to Connect Earth to SPD | Earthing Guide for Surge Protection Device | No Separate Earth For SPD
Electrical Drawings for House | Electrical Consultancy | MEP Design for House | Home Wiring Diagram
มุมมอง 39Kปีที่แล้ว
Electrical Drawings for House | Electrical Consultancy | MEP Design for House | Home Wiring Diagram
പുതിയ വീടിന്റെ ലോഡ് 10 KW മുകളിലാണോ, KSEB കണക്ഷൻ എങ്ങനെ കിട്ടും? KSEB New Connection Above 10KW load
มุมมอง 1.5Kปีที่แล้ว
പുതിയ വീടിന്റെ ലോഡ് 10 KW മുകളിലാണോ, KSEB കണക്ഷൻ എങ്ങനെ കിട്ടും? KSEB New Connection Above 10KW load
പുതിയ വീടിന്റെ ലോഡ് 10 KW മുകളിലാണോ? KSEB കണക്ഷൻ എങ്ങനെ കിട്ടും? KSEB New Connection Above 10KW load
มุมมอง 376ปีที่แล้ว
പുതിയ വീടിന്റെ ലോഡ് 10 KW മുകളിലാണോ? KSEB കണക്ഷൻ എങ്ങനെ കിട്ടും? KSEB New Connection Above 10KW load
Nice
👍
Sir water wheel energy യി ൽ 3kw ജനറേറ്റർ ചെയ്യണമെന്നുണ്ട്. ഇത് എവിടെ കിട്ടും സഹായിക്കാമോ
780 mw
Very very thank you sir good information
ചെരിപ്പ് ഇട്ടിരിക്കുമ്പോ nutral phase ഒരുമിച്ച് അടിക്കുവാണെങ്കിലോ? 🤔🤔
ചെരിപ്പിട്ടുകൊണ്ടു നമ്മൾ പണി ചെയ്യുമ്പോൾ ഏതെങ്കിലും കാരണവശാൽ ഫേസിലും ന്യൂട്രലിലും ഒരേസമയം പിടിക്കുകയാണെങ്കിൽ നമ്മൾക്ക് ഷോക്ക് അടിക്കും. മാത്രമല്ല ആ സമയം നമ്മൾ ഇന്സുലേറ്ററിനു മുകളിൽ നില്കുന്നത് കൊണ്ട് ഒരു കാരണവശാലും ഏർത് leakage വരാത്തത് കൊണ്ട് ആർസിസിബി ട്രിപ്പ് ആകില്ല അത് നമ്മൾക്ക് അപകടം ഉണ്ടാക്കുകയും ചെയ്യും. നമ്മൾ ചെരിപ്പിടാതെ നിൽക്കുമ്പോഴാണ് അങ്ങനെ ഷോക്ക് എല്കുന്നതെങ്കിൽ നമ്മൾ തറയിൽ ചവിട്ടി നില്കുന്നത് കൊണ്ട് കുറെ എലെക്ട്രിസിറ്റി എർത്തിലേക്കു പാസ് ആകുകയും ആർസിസിബി ട്രിപ്പ് ആകുകയും ചെയ്യും. എനിക്ക് തോന്നുന്നത് പ്രോപ്പർ ആയിട്ട് ആർസിസിബി വർക്ക് ചെയ്യുന്ന സ്ഥലങ്ങളിൽ ചെരിപ്പിട്ടു ജോലിചെയ്യുന്നതിനേക്കാൾ സുരക്ഷിതം ചെരിപ്പിടാതെ ജോലി ചെയ്യുന്നതല്ലേ. അതിനെക്കുറിച്ച് ഒരു വീഡിയോ ചെയ്യൂ.
thanks
thanks
But I have got electric shock (feeble) when wearing footwear and of course elcb didn't trip. So i think we will still feel it.
Hi sir
Kseb bill ആയില്ല, പുതിയ കണക്ഷൻ ആണ് കൺസ്ട്രക്ഷൻ tarif ആണ് 6kw, eppol 13kw ആകണം, മൊബൈൽ tower load revise ചെയ്യണം
how to protect earth rod/copper wire terminals from corrosion/oxidation?
Nice presentation very useful❤❤❤
Hello sir, Without lightning protection/lightning arrestor installalled in house, why have to go for type 1+2. Type 2 is sufficient no. I am saying about non solar home installations.
ഓണറുടെ പേരിലെ തെറ്റ് തിരുത്താൻ എന്ത് ചെയ്യണം അബ്ദുറഹ്മാൻ എന്ന പേര് KSEB ബില്ലിൽ അബുട്ടി എന്നാണ് തിരുത്താൻ എന്ത് ചെയ്യണം
Please upload hindi version
If i use more units than generated using solar plant, do they use the telescopic billing or directly the max rate?
Mcb
Where is your office?
Very good presentation.
Veettilekku varunna Main neutral cut aayaal randu phasil ulla randu vyathyastha loadukal thammil series connected aakukayum kooduthal resistance ulla loadinu across kooduthal voltage drop undaakukayum cheyyum.
Acd. എന്ത്
Aplicant നിലവിലെ ഓണർ ആണോ അതോ വേടിക്കുന്ന ആൾ ആണോ?
Licenced electrician nay kondu wiring cheyanam
Full contact koduthal veetuku karam kabalickapadum athu 100present orappa
What is the remedy during the under voltage condition when submersible pump is in operation.Line voltage between 150-190.Will you pl.suggest.Thaks alot🙏
രാത്രി ഫ്രിഡ്ജ് ഓഫാക്കിയിട്ടാൽ ഉള്ളിലുള്ള ഭക്ഷണ സാധനങ്ങൾ കേടായി എന്നും പുതിയ ഭക്ഷണം ഉണ്ടാക്കിക്ടിക്കാം എന്ന ഗുണം ലഭിക്കും. ഭക്ഷണത്തിനു വേണ്ടി ചിലവ് കൂടിക്കിട്ടുകയും ചെയ്യും
3 phase കണക്ഷൻ ഉള്ള വീട്ടിൽ 3 phase DB യിൽ RCCB യുടെ ന്യൂട്ടർ പോൾ output ലേക്ക് പ്രവർത്തനം ഇല്ലാതാകുമ്പോൾ out ന്യൂട്ടർ കിട്ടാത്തത് കൊണ്ട് 440V കയറി അവിടുത്തെ ഇലക്ട്രോണിക് ഉപകരണങ്ങൾ അടിച്ചു പോകുന്നു...
മാന്യമായ കൊള്ള
Multi meter use cheythu neutral to Earth value nokumbol 000 reading aanu kanikkunnathu... Phase to Earth 240 v, phase to neutral 240 v kanikkunnu..... Location flat ile oru apartment aanu.... Veedukalil nokkumbol peoper value kittunnudu.... Enthanu ethinu Karanam.....
MCB
Can you make same video in English
ഞാൻ ഓൺലൈൻ വഴി ആപ്ലിക്കേഷൻ നൽകി പണമടച്ചു പക്ഷേ എൻറെ പണം നഷ്ടപ്പെട്ടു, Failed At Pg എന്ന കാണിക്കുന്നു പണം അക്കൗണ്ടിൽ നിന്നും നഷ്ടപ്പെടുകയും ചെയ്തു എന്താണ് ചെയ്യാൻ പറ്റുന്നത് സഹായിക്കുമോ
👍
👍
Electrical design class Series ൻ്റെ എല്ലാ ഭാഗങ്ങളും തുടർച്ചയായി കിട്ടുന്നില്ല അത് വീണ്ടും കിട്ടിയാൽ വളരെ നന്നായിരിക്കും
പോസ്റ്റിലുള്ള ലൈനുകൾ രണ്ട് ഫെയ്സ് തമ്മിൽ ടച്ച് ആകുമ്പോൾ 440 വോൾട്ട് കയറി വരുന്നതാണ് അതിനു കാരണം
Thank you sir
Circuit length consider ചെയ്യണം.MCB റേറ്റിംഗ് കണക്കാക്കുന്നത് കേബിൾ സൈസ് മാത്രം നോക്കി അല്ല. ആ കേബിളിന്റെ ലെങ്ത് ഒരു പ്രധാന ഘടകം ആണ്. അതായതു ഇതിനെ ഷോർട് circuit ലൂപ് impedance എന്ന് പറയും.ഒരു നിശ്ചിത റേറ്റിംഗിൽ ഉള്ള എംസിബിക്ക് ഒരു നിശ്ചിത size ഉള്ള കേബിളിനെ പ്രൊട്ടക്ഷൻ ചെയ്യാൻ പറ്റുന്ന ഒരു മാക്സിമം ലെങ്ത് ഉണ്ട്. Loop ഇമ്പിഡൻസും mcb റേറ്റിങ്ങും മാച്ച് ആവണം. ഇല്ലെങ്കിൽ ഒരു ഷോർട് circuit സംഭവിച്ചാൽ mcb ഷോർട് circuit ട്രിപ്പ് ആവാതെ കേബിൾ ഇന്സുലേഷൻ ഡാമേജ് ആവും. ചിലപ്പോൾ അതൊരു തീ പിടുത്തതിലേക്കു നയിക്കും. വലിയ ഇൻസ്റ്റല്ലേഷനിൽ മാത്രം അല്ല ഒരു ചെറിയ വീടിന്റെ വയറിങ്ങിൽ പോലും ഈ കാര്യങ്ങൾ ശ്രദ്ധിക്കണം ✌️
Hi
Singel ഫൈസ് pump 3ഫേസ് OLR വഴി കൊടുക്കുപ്പോൾ 3 ലൈനും കണക്റ്റ് ചെയ്യണമോ ഒരു വിഡിയോ ചെയ്യമോ
Electrical Auto cad Seprate cheyyaamo?
മുൾട്ടിമീറ്റർ വെച്ചു Earth - Neutral ലൈനിൽ continuity ചെക്ക് ചെയ്താൽ continuity കാണിക്കുമോ ?
Light load ന് B6 mcb ഉപയോഗിക്കുന്നതിന് പകരം C6 mcb ഉപയോഗിക്കാമോ ?
ബ് സീരീസ് ആണ് നല്ലത് 👍🏻👍🏻 induction load നു മാത്രം C സീരിയസ് ഉപയോഗിക്കുക,, അതാണ് സേഫ്റ്റി ക്കു കൂടുതൽ നല്ലത് 👍🏻
👍
What is the MCB life? When should it be replaced (in years)?
1 ton ac ഇപ്പോഴത്തെ consumption വളരെ കുറവാണ് C10 MCB മതിയാകും
വളരെയേറെ ഉപകാരപ്രദമായ വീഡിയോ thanks
വളരെ ഉപകാരപ്രദമായ വീഡിയോ 👌👌
6 sq mm cable enough for a 3 phase meter box to DB?
Load അനുസരിച്ചല്ലേ സുഹൃത്തേ