DieseJL Garage
DieseJL Garage
  • 9
  • 215 603
FREE broken Clark air compressor | can we fix it and flip it??
My neighbor tried to throw this to the curb so I took it. Can we give her a second life??
FOLLOW US ON INSTAGRAM - diesejl
FOLLOW LISA ON INSTAGRAM - lisajezowski
As always, thanks for watching! Be sure to like, subscribe and share! Leave any questions in the comments!
มุมมอง: 311

วีดีโอ

Power is OUT - can the OBS 7.3 Powerstroke generator save the day?
มุมมอง 737ปีที่แล้ว
Today on the channel the power is out and we give the inverter generator a good test. Things are looking pretty bad until DC Power Inc. saves the day with a 270XP Alternator for the 1994 F350 7.3 Powerstroke! Check out DC POWER INC - @dcpowerinc - Instagram dcpowerinc/ www.dcpowerinc.com FOLLOW DIESEJL ON INSTAGRAM - diesejl Have something you think we would be intere...
Turning my OBS 7.3 Powerstroke into an Off Grid Backup Generator
มุมมอง 2.1Kปีที่แล้ว
Today on the channel we make my 1994 Ford F350 Powerstroke fit to backup any home in the event of an emergency. I have wanted power, serious power, in this thing for a long time so that we could work on equipment in trying situations and locations more easily. So we added a 3000 Watt 240v Inverter and a massive 2.5kWh battery. Paired with a 250 amp high output alternator, what can we not power....
Mouse died in the Kubota L Series Cab | HVAC Cleaning and Manitenance
มุมมอง 5302 ปีที่แล้ว
Today on the channel we take a look at how to access the HVAC and Radio on a Kubota L5740 Tractor. In our case, a mouse got up there and died and made quite the mess. FOLLOW US ON INSTAGRAM - diesejl As always, thanks for watching! Be sure to like, subscribe and share! Leave any questions in the comments!
Why I Failed my Garage Addition Rough In Electrical
มุมมอง 158K3 ปีที่แล้ว
Quick rundown of why I failed the rough in electrical inspection I am not a professional, just a DIYer with perspective.
Cuttin' Trees with the EGO 18" Chainsaw | Chainsaw Review and Pulling Trees with the EcoDiesel
มุมมอง 22K3 ปีที่แล้ว
Today on the channel we give some thoughts on the EGO cordless chainsaw while felling some trees. Oh, and we pull some trees with the EcoDiesel, too.
Ford OBS Powerstroke Diesel Buzz Test Contribution Test Scan Tool - Forscan
มุมมอง 23K4 ปีที่แล้ว
Today we show you how to use Forscan, a free diagnostic program, to do an injector buzz test, cylinder contribution test and read diagnostic codes and info on an OBS Powerstroke 7.3 Diesel. Cable can be purchased here - amzn.to/398hyp1 this not the only compatible cable, just one I bought and has worked good for me Program can be downloaded here - forscan.org/download.html This program can also...
OBS Ford Powerstroke F-350 F-250 ZF5 Output Seal Replacement
มุมมอง 4.7K4 ปีที่แล้ว
Today we replace the output seal on a 95 F350 with the ZF5 manual transmission. Thanks for watching, subscribe for more OBs Powerstroke content!

ความคิดเห็น

  • @kevinluce5374
    @kevinluce5374 หลายเดือนก่อน

    Panel feeders are not correct. Neutral and hot reversed.... black gounds....

  • @BrailynJimmerson
    @BrailynJimmerson หลายเดือนก่อน

    Where did you find that lock nut?

  • @BrailynJimmerson
    @BrailynJimmerson หลายเดือนก่อน

    Where did you find that lock nut?

  • @michaelc.3812
    @michaelc.3812 2 หลายเดือนก่อน

    I’m an inspector as well as a master electrician. I spotted a few things… waiting to see if it was pointed out. BTW, max height on a main breaker (or any breaker) is 6’7”. Also, the receptacle outlet next to the sub-panel will be too close, so move it at least 6” from the edge of the panel so there is no interference. Good job trying it yourself, but consider an electrical contractor next time.

  • @fazegranttv424
    @fazegranttv424 2 หลายเดือนก่อน

    Back cut way too high

  • @silasc489
    @silasc489 3 หลายเดือนก่อน

    But guy got it right

  • @silasc489
    @silasc489 3 หลายเดือนก่อน

    This is Ga boy Covin ...Yes u can run this on 94.5 dual port up to 2003 psd

  • @JustinFletcher-lv5wt
    @JustinFletcher-lv5wt 3 หลายเดือนก่อน

    Smell ever go away? Same tractor, same problem.

  • @backyardgarage5505
    @backyardgarage5505 6 หลายเดือนก่อน

    Are you saying ford skin or foreskin

  • @enriquelinares8172
    @enriquelinares8172 7 หลายเดือนก่อน

    Don’t let OSHA watch this 😅

  • @patterdalezipsuzilil
    @patterdalezipsuzilil 8 หลายเดือนก่อน

    Battery prices kill it off for me i went makita

  • @rdecker6092
    @rdecker6092 9 หลายเดือนก่อน

    How long would it take to fully charge a dead battery?

  • @TomCee53
    @TomCee53 9 หลายเดือนก่อน

    It’s always a good idea to check with your inspector before starting. Since codes and regulations vary from place to place, it’s best to ask ahead. They are generally helpful and are glad to discuss plans with you before starting. I’m not licensed but I do handyman work and have dealt with a number of inspectors. They are primarily interested in homeowner safety, mostly coming from construction or fire protection backgrounds.

  • @Mfinkbeiner22
    @Mfinkbeiner22 9 หลายเดือนก่อน

    Great e saw since i have the ego my husky 555 is sleeping. Here my impressions from the black forest in Germany th-cam.com/video/XRnlEcnqIq8/w-d-xo.htmlsi=XgYvX_ecjTuu4-0c

  • @johndavies2949
    @johndavies2949 10 หลายเดือนก่อน

    And know you know why electricians are licensed.

  • @johndavies2949
    @johndavies2949 10 หลายเดือนก่อน

    So you're not a qualified person as per NEC article 100(definitions)

  • @michman2
    @michman2 11 หลายเดือนก่อน

    I use a 16" model and I need a break before the battery does.

  • @rbish907
    @rbish907 11 หลายเดือนก่อน

    Holy osha, who in there right mind thinks its a good idea to hual that big of shit with a jeep?

  • @axellohse8426
    @axellohse8426 11 หลายเดือนก่อน

    Der recht hohe Akkupreis wird ja auch durch ausbleibende Spritkosten kompensiert, erst recht wenn der Strom aus einer vorhandenen Solarquelle kommt.

  • @qum3456
    @qum3456 ปีที่แล้ว

    OMG. What a stupid back cut location. Like 8” to high. What were you thinking??

  • @royboy3597
    @royboy3597 ปีที่แล้ว

    In my humble opinion. Tamper proof outlets is breaking balls. The are a bummer to use too

  • @Mercy-lb5rq
    @Mercy-lb5rq ปีที่แล้ว

    Thank you

  • @keithpeacock9282
    @keithpeacock9282 ปีที่แล้ว

    The black wire with the white strip should go to the Neutral Bar and the black wire should go to L1. Also if a white wire goes to a breaker it HAS to have a color tape on it! and black wires going to a Neutral HAS to have a white tape on it. Also the main panel feed wires does not look big enough to handle that amp load of all the breakers

  • @niveknospmoht8743
    @niveknospmoht8743 ปีที่แล้ว

    Just replaced my main panel to a 400a service. That was quite a fiasco, but I was informed that a surge protector is now required on new installs. So..about 150.00 later, I now have a surge protector covering my whole house. When I wire in the other 200 available, I'll have to get another for the shop panel

  • @ionbusman2086
    @ionbusman2086 ปีที่แล้ว

    Remind me not to pull any permits. These are stupid

  • @GoatZilla
    @GoatZilla ปีที่แล้ว

    I don't understand the light for the confined storage area. I have some small closets that don't have lights, so is there some additional minimum size requirement?

  • @WilliamMurphy-d8s
    @WilliamMurphy-d8s ปีที่แล้ว

    So many codes so few dollars. Sad thing is many codes are redundant or overkill.

  • @C1Ksdafafdsa980ufsd
    @C1Ksdafafdsa980ufsd ปีที่แล้ว

    I'm trying to start a new shop project... soon. One of my biggest fears is that I'm 45 yeas out of date, and codes as well as construction practices change. PEX is all "new" for me. We had GFCIs, but not Arc Faults. Then, of course, there are local codes. St. Louis had something that they only allowed one wire per hole in a stud or joist. Can anybody say SWISS CHEESE? I've had many problems with GFCI outlets, and would never use one unless absolutely necessary (near a sink). Those child proof plugs would be a pain in a workshop, although perhaps they would help with dust and corrosion.

  • @smeado3533
    @smeado3533 ปีที่แล้ว

    Dude, you also switched the neutral with one of the hots going into the main panel breaker. How did the inspector miss that???

  • @fredjones1238
    @fredjones1238 ปีที่แล้ว

    anybody can screw up but not anybody can fix a screw up GOODJOB

  • @turboflush
    @turboflush ปีที่แล้ว

    Exactly. Codes are there to help and be safe. It sucks when the city wants to be a pain over silly things though. Diyer should have inapection to ensure their own and families safety. Contractors get inspected so that the homeowner can have piece of mind.

  • @diesejlgarage8057
    @diesejlgarage8057 ปีที่แล้ว

    Want 10% off your own DCPOWERINC alternator? Use Coupon Code diesejl !!!

  • @JessiJohnson1
    @JessiJohnson1 ปีที่แล้ว

    You don’t seem to know how to cut down trees properly

  • @joseph5348
    @joseph5348 ปีที่แล้ว

    Yes,yes you can fix it, (spoiler alert).!!!

  • @williambutler3103
    @williambutler3103 ปีที่แล้ว

    Where's the safety glasses?

  • @Mike-01234
    @Mike-01234 ปีที่แล้ว

    I don't like the new auto adjustment on the EGO makes the chain too tight IMO.

  • @greghawn3774
    @greghawn3774 ปีที่แล้ว

    the suspense was killing me, hope they are better at diesel garage than cutting down trees, way to high on his back cut. Somebody is going to get hurt someday

  • @colescarkingdom
    @colescarkingdom ปีที่แล้ว

    A lot cheaper than a new F150 Lightning with onboard power, lol.

  • @randygreene5977
    @randygreene5977 ปีที่แล้ว

    I like the way you installed everything in the tool box. My only concern is the amount of heat the inverter will generate. Not a much space to radiate heat.

    • @diesejlgarage8057
      @diesejlgarage8057 ปีที่แล้ว

      Yeah I’m gonna add heat management next!!

  • @duanekalmbach1864
    @duanekalmbach1864 ปีที่แล้ว

    Do you have a link to the inverter ?

    • @diesejlgarage8057
      @diesejlgarage8057 ปีที่แล้ว

      It’s in the Amazon store which is linked below!!

    • @duanekalmbach1864
      @duanekalmbach1864 ปีที่แล้ว

      @@diesejlgarage8057 i found the link in your installation video.... i still dont see it listed in this video

  • @kevinroberts781
    @kevinroberts781 ปีที่แล้ว

    The question is why did you even get a permit??? Are you free or not? Lesson learned I hope.

  • @TechOut
    @TechOut ปีที่แล้ว

    Should high idle it instead of letting it sit and idle all the time.

  • @lisalewis9237
    @lisalewis9237 ปีที่แล้ว

    Hi, Nice setup. Have you given any thought to adding a high idle kit to your truck? Alternators really perform better at higher engine speeds. It's also not really good to let your truck idle for hours on end. They really need to run at a higher rpm, to keep the engine cool and get good sealing on the piston rings. RainManRay's Repairs just did a video on adding a high idle kit to a Silverado 2500, with the 6.6 Duramax diesel engine. th-cam.com/video/7f9Wn5w735U/w-d-xo.html

    • @diesejlgarage8057
      @diesejlgarage8057 ปีที่แล้ว

      I will when I get a chip. Need to do injectors and turbo before that though!!

  • @gailliardander
    @gailliardander ปีที่แล้ว

    So cool man seriously I like the way u think

  • @AHFixIt
    @AHFixIt ปีที่แล้ว

    Such an awesome setup!

  • @cpthillbilly
    @cpthillbilly ปีที่แล้ว

    I would recommend you re-wire those feeds. YOu have the neutral wire where a phase should be and a phase is where the neutral should be. Yes, it is a code violation too. Whether your inspector know that or not. White wires MUST be neutral wires only, not phase conductors.

  • @bimmerboard
    @bimmerboard ปีที่แล้ว

    Also, I love the way you fabricated the sheet metal to make a totally professional installation. Nice work. But you definitely need to place an isolated DC-DC converter or charge controller between the truck battery and the inverter battery. The LiFePO4 batteries can pull an enormous amount of current which can destroy your alternator, and it can also deplete your truck battery. In addition, the 13.6 volts that the alternator produces isn’t enough to charge the LiFePO4 battery, with needs around 14.6 volts to charge. This is another problem solved by a DC-DC converter or charge controller, which can take varying input voltage and provide the exact needed voltage for charging. Get a Victron or Renogy isolated DC-DC converter and you’ll be set.

  • @bimmerboard
    @bimmerboard ปีที่แล้ว

    Nice work, but soldering the connectors is dangerous. If the cables heat up, or vibrates loose, the solder can melt and cause a fire. They should be crimped, ideally with a hydraulic crimping tool.

  • @dougpine4746
    @dougpine4746 ปีที่แล้ว

    Think you will find that under high loads the inverter will sometimes shut down from over heating. They require a lot of breathing room and good ventilation to allow them to cool off the internal electronics. Def need a charge controller and auto isolation so you dont drain your truck batteries or damage them when running for extended periods.

  • @EddieEuwen
    @EddieEuwen ปีที่แล้ว

    You need a dcd2dc charge controller for LiFepo4 Batt.