Overnight or cheap rate battery charging PC configuration including Live Demo.
Utilising EV or cheap overnight electricity rates to charge your inverter batteries with Live Demo!
If you fancy 50:50 sharing £100 for changing to Octopus as your energy supplier, please feel free to utilise my referral link. And thank you! share.octopus.energy/super-ant-124
Steps:
Login to www.solidcloud.com with the same credentials as your phone app.
Select Overview then Device Tab.
Top right corner, choose Inverter Control button
Work Mode - Self Use Mode
"Allow Grid Charging" - Enable
"Time of Use Switch" - Enable
"Charge and Discharge 1-3" - Add a charge current, plus a timeslot for charging.
Ensure other slots don't overlap it with a different action (e.g. a discharge configured at the same time as a charge)
Sleep tight, sweet dreams and wake up to a charged battery.
Please note that you need one of the following dongles in order to access control.
S3-WIFI-ST, S2-WL-ST, S3-GPRS-ST, S4-W4G-ST, S4-WIFI-ST
DLS-W, DLS-L, DLS-G, DLB-W will not work.
RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES-5G
S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L
มุมมอง: 3 599

วีดีโอ

Unboxing the Solis Series 6 Energy Storage Inverter Pt 2 - Detailed look.
มุมมอง 2.5Kปีที่แล้ว
Considering a Solis S6-EH1 inverter? Let's explore further the Inverter and connectivity. S6-EH1P3K-L-EU S6-EH1P3.6K-L-EU S6-EH1P4.6K-L-EU S6-EH1P5K-L-EU S6-EH1P6K-L-EU
Unboxing the Solis Series 6 Energy Storage Inverter Pt 1
มุมมอง 1Kปีที่แล้ว
Considering a Solis S6-EH1 inverter. Let's take a look at what's in the box. S6-EH1P3K-L-EU S6-EH1P3.6K-L-EU S6-EH1P4.6K-L-EU S6-EH1P5K-L-EU S6-EH1P6K-L-EU
First Look at the Solis Series 6 Energy Storage Inverter
มุมมอง 2.4Kปีที่แล้ว
Considering a Solis S6-EH1 inverter. Let's take a first look at the brand new hybrid PV inverter. Bullet Point improvements over the RHI/E1H S5 Series: Based on the 6kW model: * PV input up to 9.6kW from 8kW. * Battery charge/discharge rate now matches AC rate (so 6kW on 6kW model) * Higher output EPS supplies (matching AC grid capacity) * New 8kW model introduced with 8kW to/from battery rates...
Overnight EV Charging without using your solar/PV battery
มุมมอง 6Kปีที่แล้ว
Want to charge your EV without draining your solar batteries? We explain the approaches - both by enabling PV charging at a super low rate, or by preventing your PV inverter supporting house and car load during the car charging timeslot. RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES-5G S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L
Solis Wifi Dongle / Datalogger Reboot
มุมมอง 14Kปีที่แล้ว
Is your SolisCloud app all greyed out, but you've checked your Wifi and it's all fine. It's possible the datalogger needs a reboot. Here's how to disconnect and re-attach your dongle, without shutting down your inverter. RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES-5G S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L
Checking the Alarm Message Log
มุมมอง 4.7Kปีที่แล้ว
To check the inverter's alarm history, perform the following steps: 1. Press the "Enter" button to access Main Menu. 2. Scroll down to "Advanced Info." 3. Enter pass code "0-0-1-0" (press "Down-Down-Up-Down"), then press "Enter." 4. Within the "Advanced Info" submenu, select the first option, "Alarm Message." This will display the 100 latest alarm messages, along with the date and time they occ...
Solis Alarm - MET_SLT-FAIL
มุมมอง 11Kปีที่แล้ว
Is your Solis Hybrid Inverter showing an alarm MET SLT FAIL? Check this video to reconfigure for the correct modbus meter. The alarm "MET_Comm-FAIL" is given when the inverter does not detect the external Acrel or Eastron meter and it is expecting to. "RS485 Fail" will also show on the screen between the inverter and the meter. If no external Acrel or Eastron meter is installed, then "No Meter"...
Checking new batteries are recognised by the inverter
มุมมอง 10Kปีที่แล้ว
If you've just added new batteries or even your first battery, you need to know the inverter is aware of it. Based on the continuous charge current of your battery from the manufacturers spec, you can ensure the inverter sees the new purchase. For ref: Pylontech US2000C - 25A per pack Pylontech US3000C - 37A per pack Pylontech US5000 - 80A per pack Fox LV5200 - 100A per pack RHI-3K-48ES-5G RHI-...
Export power management
มุมมอง 17Kปีที่แล้ว
Limiting solar export to the grid or your display showing LmtByEPM EPM The backflow settings on the EPM is probably the most important settings - it controls the limit of power the Export Power Manger will allow into the grid. To change this setting do the following: Press ENTER to open the menu Scroll DOWN to Advanced Setting and press ENTER Type in the code 0010 (DOWN, DOWN, UP) and press ENT...
Setting the time and date.
มุมมอง 6Kปีที่แล้ว
If you need to set or amend the time and date on your Solis Hybrid Inverter, which quick video will guide you. With British Summertime coming to an end it's essential to check your time is accurate so as not to me overnight charging at plea rate when you're expecting to be in overnight rate, but only if your clock is accurate. GMT BST RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES...
See Weather Information Solis Hybrid Inverter
มุมมอง 9Kปีที่แล้ว
Is your weather information missing on the SolidCloud App? Then you need to watch this. How to set the location by GPS, and display the weather, temperature, sunrise and sunset RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES-5G S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L
Configuring your battery cut off level
มุมมอง 27Kปีที่แล้ว
Setting up your inverter and battery for optimal depth of discharge and SOC cut off. And force charge to prevent batteries going completely flat. Overdischg SOC ForceCharge SOC For Ref: (DoD = Depth of Discharge) Pylontech US2000B - 80% DoD for 6000 cycles or 90% DoD for 4500 cycles lifespan Pylontech US2000C - 95% DoD Pylontech US3000 - 90% DoD Pylontech US3000C - 95% DoD Pylontech US5000 - 95...
Overnight or cheap rate battery charging at the Inverter
มุมมอง 42Kปีที่แล้ว
Utilising EV or cheap overnight electricity rates to charge your inverter batteries. Also available to configure via PC Web Browser at th-cam.com/video/ps22E30OUEk/w-d-xo.html Text copied from Solis for clarity: How to set up self-use and if needed time of use to set charging times on RHI hybrid inverters 1) Make sure you have the right battery selected on the inverter. Advanced Settings (passw...
Getting to know your Solis Series 5 Hybrid (energy storage) Inverter.
มุมมอง 35Kปีที่แล้ว
Getting to know your Solis Series 5 Hybrid (energy storage) Inverter.

ความคิดเห็น

  • @johnduddy4136
    @johnduddy4136 8 วันที่ผ่านมา

    Thanks Peter, very informative as usual.

  • @zippybanana2691
    @zippybanana2691 14 วันที่ผ่านมา

    Awesome, thanks

  • @mohammadmougharbel3015
    @mohammadmougharbel3015 หลายเดือนก่อน

    Good day dear, I need to know please if i can link my 12 panels 700watt each with a total panels voc of 585 and my solis max is 600 volt. Is it safe especially that i heard in winter when the temperature is 5c the voc of the panels will exceed the 600 v of the inverter. Can i link them in my solis in 1 MPPT for better efficiency or it might be not good ? Many thanks

    • @SolisNotSolis
      @SolisNotSolis หลายเดือนก่อน

      @mohammadmougharbel3015 Hello. The VoC is normally specified at 20 degrees but can be considerably higher at closer to zero degrees. My own panels are 34v nominal but that rises to 38 in cold conditions. 585 is far too close to the limit in afraid. And inverters do fail easily when the strings go over voltage

    • @mohammadmougharbel3015
      @mohammadmougharbel3015 หลายเดือนก่อน

      @@SolisNotSolis many thanks

  • @EmmanuelOMOZARANI
    @EmmanuelOMOZARANI หลายเดือนก่อน

    My name Mr Emmanuel I Have problem wait Inevrter solis , the problem Inverter pending

  • @edgarrapisora2712
    @edgarrapisora2712 หลายเดือนก่อน

    Hi Sir, could you send the link store, to buy acrel meter 1 phase. Thanks

  • @alancwright
    @alancwright หลายเดือนก่อน

    It’s worth mentioning check your smart meter. Mine was set to 00:30 -07:30 in winter, and in summer this was 01:30-08:30, they don’t change to BST. I raised this with my supplier e-on and they said they wouldn’t change the meter unless it was 2 hours out. I got the Bright app and checked my meter. I charged my battery from midnight and i was charged normal day rate until 01:30 from April. I am in the process of disputing it, but thought to let anyone doing charge from the grid to check your meter,it may ne incorrectly configured.

    • @SolisNotSolis
      @SolisNotSolis หลายเดือนก่อน

      @alancwright it's a fair point and although my supplier don't change the time either (it remains gmt) they do change their charging plan to match BST so you don't need to change charge times

  • @TrevorGordon-j6z
    @TrevorGordon-j6z หลายเดือนก่อน

    Nice clear and simple instructions. Thank you.

  • @pdday123
    @pdday123 หลายเดือนก่อน

    How do i know what kind of meter i have. Are the meters you are referring to the small din rail meters on a electrical sub board? As mine are not branded eastrom or acrel.

  • @Maksym-v9l
    @Maksym-v9l 2 หลายเดือนก่อน

    Hello. is it possible to reset the acrel ACR 10r counter to factory settings?

  • @DanielsThierry
    @DanielsThierry 2 หลายเดือนก่อน

    uhm, question. I want to use the solar power to charge the batteries and discharge to the house in the evening and night. i've put in the setting from the manual, yet it doesn't work like what i ask from it. any advice ?

  • @mariusluciannae800
    @mariusluciannae800 2 หลายเดือนก่อน

    Hi Peter, Mine was installed 2 weeks ago, 6kw inverter, most of the days I am not seeing any export, all that is produced is showing as house usage but I have nothing to use 3-4kwh, is there a setting in the inverter that must be wrong? Sometimes it shows all that is produced as export. I have a 10kw battery as well. Can't post a screenshot.... Hopefully you can help. Thanks

    • @SolisNotSolis
      @SolisNotSolis 2 หลายเดือนก่อน

      That sounds very much like the monitoring current transformer (CT) and modbus meter (Eastron or Acrel) are incorrectly placed or not working. If you are seeing "excessive" household load that isn't there, it is usually because the installer has put the CT onto the inverter itself, or the household consumer unit itself so it isn't seeing the sum of the house load plus the PV at the same time. If you use Facebook, you could catch up with us over on the Solis group there were you can post some pictures of the install more easily? facebook.com/groups/288045168816481

  • @phunkyphantom619
    @phunkyphantom619 2 หลายเดือนก่อน

    Weve recently moved into a house with a Solis 5 installed and we dont have access to the web or app, installer isnt interested as were passed their 12 month warranty and call out. Is there a way to set this up ourselves or do we have to pay for the installer to come our? Our inverter has an ethernet cable running down does that mean its cloud enabled?

    • @SolisNotSolis
      @SolisNotSolis 2 หลายเดือนก่อน

      Hi. You can either buy a new datalogger and setup an online account yourselves. or take the data logger and inverter serial number (left hand side of the inverter case, and rear face of the dongle/data logger) and raise a ticket with Solis support to explain the circumstances. They should be able to unlink the devices from the existing account allowing you to add them to a new account.

  • @clivemillard4288
    @clivemillard4288 2 หลายเดือนก่อน

    Very Helpful is it possible to print off the script for the vidio instructions ??

  • @donnabyrne443
    @donnabyrne443 2 หลายเดือนก่อน

    Hi, Is it possible to do this from the Solis cloud app? Thanks.

    • @SolisNotSolis
      @SolisNotSolis 2 หลายเดือนก่อน

      Hello. I'm afraid it isn't. This part is in theory at least installer only, so isn't given in the customer app view.

    • @donnabyrne443
      @donnabyrne443 2 หลายเดือนก่อน

      @@SolisNotSolis thanks for replying. Never mind, I thought that might be the case. I have a different inverter to the one you have so not sure how I would change it on there. Would a call to solis support work or do I need to go back to my installer?

    • @SolisNotSolis
      @SolisNotSolis 2 หลายเดือนก่อน

      @@donnabyrne443 Hi. Which model of "different inverter" do you have?

    • @donnabyrne443
      @donnabyrne443 2 หลายเดือนก่อน

      @@SolisNotSolis the model number is S5-EA1P3K-L

  • @donnabyrne443
    @donnabyrne443 2 หลายเดือนก่อน

    are you able to help? I don't have the 'Inverter control' button but when i check my account settings it says i am the owner not a guest. thanks

  • @jayanthadharmasiri
    @jayanthadharmasiri 2 หลายเดือนก่อน

    How to add weather info to Solis inverter S6-GR1P5K-S, please?

  • @wassaufkhalid8593
    @wassaufkhalid8593 2 หลายเดือนก่อน

    We have a hybrid 6kw solis inveter and a volt protector device attached before it. The voltage protector show 2 to 2.5 amp import from grid while the inverter app shows that grid is not being used and power is only coming from solar. What is the problem?

  • @buddysalvador7416
    @buddysalvador7416 3 หลายเดือนก่อน

    Hi please how to get in to reserve soc i cant find it in the storage set do i need to download solis cloud?

  • @googlelansdown
    @googlelansdown 4 หลายเดือนก่อน

    I set my solis inverter to charge at cheep rate and to discharge during the day and it worked for two days. This morning I adjusted the timing and now the inverter won’t discharge, I wonder if it will attempt to charge tonight?

  • @martincuthbert7670
    @martincuthbert7670 4 หลายเดือนก่อน

    Can you control it with HA as easy as the S5

    • @SolisNotSolis
      @SolisNotSolis 4 หลายเดือนก่อน

      Hi. It appears they've had a good shuffle around of the registers and the dongle is far more like that supplied with SunSynk and some other brands, but once you've got to grips with the changes, yes it works fine.

  • @SeanHiggins1
    @SeanHiggins1 4 หลายเดือนก่อน

    Very clever, i never considered stopping the battery entirely during the cheap rate window even for low loads. Definitely going this ASAP

  • @GiorgioChallenger
    @GiorgioChallenger 4 หลายเดือนก่อน

    Good morning, I have 2 photovoltaic systems, the first with 6kW panels and the other with 3kW panels. Wanting to charge the batteries of the second system using the electricity mains from 11am to 3.00pm since I wouldn't spend anything, what should I do? Thank you

  • @WojtekUK
    @WojtekUK 4 หลายเดือนก่อน

    SOL-S6-EH1P8K-L-PRO wen is available in the UK?

  • @WojtekUK
    @WojtekUK 4 หลายเดือนก่อน

    SOL-S6-EH1P8K-L-PRO when is available in the UK ?

  • @joaoscreed
    @joaoscreed 4 หลายเดือนก่อน

    Thank you very much. Your video helped me to solve my problem.

    • @SolisNotSolis
      @SolisNotSolis 4 หลายเดือนก่อน

      You are very welcome.

  • @gmobeybill
    @gmobeybill 4 หลายเดือนก่อน

    Hi Pk on Solis, can help me to understand why will electric usage skyrocketed soon as I put on my storage battery and keeps charging at anytime even when I have set up charge time to be 2 am till 4 am.

    • @SolisNotSolis
      @SolisNotSolis 4 หลายเดือนก่อน

      Most commonly it is because the monitoring CT is either on the wrong cable (i.e. not under the supply meter and has been installed under the inverter or only on the household consumer unit when it also needs to see the (separate) PV board). Or it's facing the wrong way around on the cable it's attached to.

  • @GiorgioChallenger
    @GiorgioChallenger 4 หลายเดือนก่อน

    Good morning, congratulations for the explanation, I'm writing to you from Sicily. I have a 6 kW system connected to the manager for on-site exchange. I created another system with dedicated 3.2 kW panels attached only to the new inverter of the same type as in your video. The question is one, if there is little sun what the inverter takes from its panels if it is not enough for example to operate a 2000w oven it takes the requirement from the batteries therefore not using for example an input power of the panels from 1000w to charge if the batteries run out. Therefore, reading through the AT, a consumption of 2000 W takes 1000 from the panels and 1000 from the batteries. In reality I produce more energy with the other system and I can easily tolerate a higher discharge of 3kw. Question: From the table indicated at minute 4.45 where there are the words Charge time and discharge time, I would like for example from 7am until the 3.2kW panels produce charging the batteries. If full, place the surplus inside the house so as to have available the total current produced by the panels of the two 6 + 3.2 kW systems. Using the discharge parameters I would like to set the use of the batteries if required by the production insufficiency, for example from 08.00 pm to 07.00 am. Does this term discharge serve precisely to program the times in which I can draw from the batteries? Thank you so much. George

  • @zedhal5258
    @zedhal5258 5 หลายเดือนก่อน

    Hello, I am considering an off grid solis inverter in my system. I came across your video, which is very good with right balance between device capabilities and description. Would you happen to know if I was to use a secondhand solis inverter for an off grid system whether I can still create an account and use the solis app?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      The online account is based on the wifi/lan/gprs data logger so as long as you buy a new datalogger, you can use a second hand inverter.

  • @Rianewjob01
    @Rianewjob01 5 หลายเดือนก่อน

    Thanks very much. I have no idea what any of this means but, thanks to your video, the problem is solved.

  • @nic47531
    @nic47531 5 หลายเดือนก่อน

    Are these available in the uk?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      Not yet I'm afraid. They were due out last year, but have been delayed for some reason.

  • @HamzaKhans
    @HamzaKhans 5 หลายเดือนก่อน

    Hi. Thanks for the details. I got mine installed a month ago. I am concerned about connecting Narada lithium ion BMS to the inverter. Could you please guide in this regard

  • @poc353
    @poc353 5 หลายเดือนก่อน

    That’s very helpful, thanks. I’ve set a 3 hr charge window at 1 Amp when I charge my EV. If I decide to charge my solar batteries at this time also, what’s the max amperage/current I should be updating the charge amperage/current to?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      Hi. Depends on what model of inverter and what batteries and how many you have.

    • @poc353
      @poc353 5 หลายเดือนก่อน

      ​@@SolisNotSolis Solis S5-EH1P5K-L (rated power of 5kW) and two 5.3kWh batteries (two WeCo 5k3 modules).

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      @@poc353 Ok, so the inverter is 100amp peak, more like 85-90A sustained charge rate dependent how well cooled it is. I'm not familair with the batteries but a quick google seems to imply max charger current of 100a. So your limit will be the inverter not the batteries. Bear in mind 20 A x 1 hour is roughly 1kWh of charge and that should guide you

    • @poc353
      @poc353 5 หลายเดือนก่อน

      @@SolisNotSolis thanks very much - much appreciated. Yes, those batteries are 1C rated. That makes sense then, I’ll probably start with 50a or so. Thanks again.

  • @robinbennett5994
    @robinbennett5994 5 หลายเดือนก่อน

    Thanks, that's really helpful. I'd not thought of setting the discharge rate to zero. Do you need to change these settings at the start and end of British Summer Time?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      Hi. That depends on your energy supplier. The inverter will correct itself and if you use Octopus for example, they follow BST. One or two don't and stick with GMT all year round

  • @RFC1021
    @RFC1021 5 หลายเดือนก่อน

    In the summer how do you switch off the force overnight charge ?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      The easiest method is to disable Time of Use via the little menu that is just enable/disable Time of Use. All the time settings and charge rates remain in place, they're just ignored.

  • @amaaan-cx9nm
    @amaaan-cx9nm 5 หลายเดือนก่อน

    Thank you for clarifying the procedure to follow. Do you have any ideas as far as the wiring diagram goes? During installation the dongle was twisted which caused some of the cable to become loose, leaving me with no clue wich wire goes to which of the four connectors

  • @chrissalisbury7826
    @chrissalisbury7826 5 หลายเดือนก่อน

    Can you set it up to charge at night of EV tariffs and charger day via solar panels?

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      Hi. It will charge batts from solar by default in Self Use mode during the day. If you check my other videos there's a couple on overnight charging from the grid which you can set to your cheap energy timeslot.

    • @chrissalisbury7826
      @chrissalisbury7826 5 หลายเดือนก่อน

      @@SolisNotSolis thanks

  • @davescrim1
    @davescrim1 5 หลายเดือนก่อน

    Are you able to re-do this video with the latest web page version as an update? Otherwise another great video and glad I don't have to go outside to do this!

  • @davescrim1
    @davescrim1 5 หลายเดือนก่อน

    Strange why my PylonTech Force L-2 batteries only have a listed discharge of 100Amp for 3 -7 packs, when their other batteries increase with each unit added??

    • @SolisNotSolis
      @SolisNotSolis 5 หลายเดือนก่อน

      L2s are a bit odd. The total capacity is given by the control module and it's capability, rather than the sum of the packs as would be the case with none stackable Pylontechs.

  • @davescrim1
    @davescrim1 6 หลายเดือนก่อน

    My Charge rate is just 14.8A and discarge 100A. Do you know why the charge rate is so low?

    • @SolisNotSolis
      @SolisNotSolis 6 หลายเดือนก่อน

      If that is on the time of use screen, then it's the values someone has set. Or are you referring to the Control Parameters page?

    • @davescrim1
      @davescrim1 6 หลายเดือนก่อน

      @@SolisNotSolis It's on page three of the Information Screen (BMS information). It's gone up to 59A now, but the batteries are full (if that makes a difference). I have four PylonTech Force L-2 batteries..

    • @SolisNotSolis
      @SolisNotSolis 6 หลายเดือนก่อน

      @@davescrim1 Ok, that rate is coming from the batteries. If they're full, it will reduce. You can amend it for the max value up to 100A and save it, which will then be over-displayd by the presently possible value being sent by your battery BMS.

    • @davescrim1
      @davescrim1 6 หลายเดือนก่อน

      @@SolisNotSolis Do you know which screen I would need to change this on as the Info. screen does not appear to be editable? Cheers.

    • @SolisNotSolis
      @SolisNotSolis 6 หลายเดือนก่อน

      @@davescrim1 Stoage Energy Set > Control Parameters.

  • @stevecooke1636
    @stevecooke1636 6 หลายเดือนก่อน

    Is there any way to access the settings shown in these videos other than by going directly to the inverter control panel - e.g. a web page - and avoid climbing into a loft? The basic web page I can see on my system only allows very basic setting changes such as WiFi connections and server addresses - is there also a URL that would give access to the more advanced functions? Thanks

    • @SolisNotSolis
      @SolisNotSolis 6 หลายเดือนก่อน

      Hi. Yes. Both. Assuming you've requested remote management permissions, under the Device, three dots top right of the screen on both the web interface and the phone/tablet app.

  • @wkxy2002
    @wkxy2002 6 หลายเดือนก่อน

    Mi scusi ho 2 batterie us3000c ma non è stato settato nessuna batteria come master può influire?. Grazie ho un inverter della solis da 5kw per le info del bms ho il cavo sulla porta a/can

  • @maryhaddock9145
    @maryhaddock9145 6 หลายเดือนก่อน

    Great, thanks. Just what I wanted to know.

  • @thehumanoid
    @thehumanoid 6 หลายเดือนก่อน

    Thanks

  • @paulbuzzard5366
    @paulbuzzard5366 7 หลายเดือนก่อน

    Hi Peter I'm just in the process of adding a new battery to my system I only have one at the moment.so I'm going to take down the older one and balance it with the new one and then I'm going to use the new one as the slave.could you tell me which way I do the coms cable to each battery.and also do I need to turn off the inverter or just the batteries hope to hear from you soon.paul

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi Paul. You haven't said what batteries you've got.. and what you are adding so rather hard to help!

    • @paulbuzzard5366
      @paulbuzzard5366 7 หลายเดือนก่อน

      @@SolisNotSolis sorry Pylontec us2000.

  • @MaxZoettl
    @MaxZoettl 7 หลายเดือนก่อน

    Thank you for this really useful video. What a nice piece of kit! However, it seems very slow to enter the UK market: does anyone know when it will be released in Britain?

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi. It's based on the wholesalers clearing the S5 series before they'll buy stock of the S6 otherwise they'll be stuck with them.

    • @AdrianMcDaid
      @AdrianMcDaid หลายเดือนก่อน

      Or released in the UK as I live there

  • @paulbuzzard5366
    @paulbuzzard5366 7 หลายเดือนก่อน

    Hi Peter I have a 3.6 klw inverter solis and I've changed the time on to grid charge but I have only 1 battery and the input charge is 10 amp and the discharge is 25 amp.I have a us2000 Pylontec battery can I increase the input charge to 20 amp safely as after grid charge for 3 hours 20 mins it is still at 20%when we get up at the moment we have our electric underfloor heating on a low setting just wondered if you can help.Paul

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      The charge (and discharge rate) of a US2000 is 25 amps. So you can happily/comfortably/safely up both to 25A.

    • @paulbuzzard5366
      @paulbuzzard5366 7 หลายเดือนก่อน

      @@SolisNotSolis Thanks for the update, do I change the amp input on the control parameter setting Paul

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi. Yes both control parameters and charging current on time of use page. @@paulbuzzard5366

    • @paulbuzzard5366
      @paulbuzzard5366 7 หลายเดือนก่อน

      @@SolisNotSolis can you tell me where to find this time of use page on advanced settings paul

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      th-cam.com/video/h1A80cSOrhA/w-d-xo.html @@paulbuzzard5366

  • @gerrybaylis3916
    @gerrybaylis3916 7 หลายเดือนก่อน

    Hi Peter, I wonder whether you can enlighten me please. I can't get my head around the legends and direction of travel of the arrows on the display, especially for the battery when charging. My Storage mode select/Time Charging option has Optimal Income available as Stop and Run. Depending on which I select, the direction of travel on the main display around the battery shows the battery either charging/ discharging immediately change I'm having to change my Time charge times to suit something I don't understand. Where do I see whether I'm paying for the charge or getting it free for the panels? The scenario I'm trying to get to is that my panels start to generate at about 9:30am, I have two big ticket devices, pool pump comes on at 11am, pool heater comes on at 1pm. both go off about 4:30pm Together they consume about 2.4kw. At this time of year I'm generating about 3.7kw. I don't have a cheap rate as such but I've got 2 free hours from 18:00 to 20:00. I only have one time charge period on my time charging screen when I could really do with more. My manual references Optimal Income Stop, but it doesn't say what happens when it's selected. As I have no intention of receiving income from the panels, ideally I want to charge the batteries between 18:00 to 20:00 but I seem to be creating a conflict when I do this. I would be really grateful if you could suggest some settings that I could start off with Thanks in anticipation Very best regards Gerry

  • @wkxy2002
    @wkxy2002 7 หลายเดือนก่อน

    Great video and I discovered a feature I didn't know about. I would like to know if it is possible to set this solis to work even in the absence of electricity. Thank you

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hello. There is a "EPS" output which has a variable capacity dependent on the inverter model. This is permanently live, powered from battery. The batteries can also be charged from PV while the grid is down too.

  • @gerrybaylis3916
    @gerrybaylis3916 7 หลายเดือนก่อน

    Hi Peter Sorry to bother you with trivia. Based on some of your past suggestions I've embarked on upgrading all of my fuse panels and circuit breakers. The inverter was connected to a 25A differential. It has now been renewed (I know what you are going to say "it's only doing it's job" ) but the rcd keeps tripping in the evening when there is no apparent load, only battery replenish time. Should this be an rcd or a normal circuit breaker. When I look at the alarm messages it's littered with 'no grid' messages. Before the new rcd it didn't trip and managed to recover but now the tripped inverter depletes the battery. This morning whilst I'm recharging the battery, with the grid off, the panels recharge the battery nicely and soon as I reconnect the grid the direction of flow changes from recharging the battery to discharging by 1.2kw. with panels generating 2.8kw and a load of 1kw, even with no load the battery is being discharge at a rate of 1.2kw. There is no discharge time set, but it seems hell bent on discharging the battery Is there an overall flowchart to help me understand what is happening? Any ideas please

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi. It is an RCD or an RCBO? And what type is it (I don't mean the trip curve, which will probably be a B if an off the shelf device). I mean is it an A type or AC or B or F type RCBO?

    • @gerrybaylis3916
      @gerrybaylis3916 7 หลายเดือนก่อน

      @@SolisNotSolis It says type AC on the front but I can replace it with whatever you think it should be Many thanks

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      It should be an "A" type (or "B" type - subject to manufacturers specification) Although I question do you really need one? Is the cabling exposed throughout it's run? If so then you wouldn't require one in the first instance. @@gerrybaylis3916

    • @gerrybaylis3916
      @gerrybaylis3916 7 หลายเดือนก่อน

      @@SolisNotSolis That's what I was hoping you would say. I find this sight the information you give out inspiring. One last question for today I have an RHI-5K-48ES the max output is 3000W on the label. It was sold to me as a 5kw inverter can I generate more than 3Kw to the house Many thanks Best regards Gerry

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi. Not sure what the 3000w refers to and can't think what it would apply to on a 5kW unit to be honest. But 5kW is 5kW to AC. And/or 5kW to/from batteries peak (sustained long term eg overnight charging it's more like 4-4.5kW to/from batteries) @@gerrybaylis3916

  • @ChrisHearn-z4m
    @ChrisHearn-z4m 7 หลายเดือนก่อน

    Hi Peter, With this setting set to 3600W as you show in the video will the inverter still be able to supply more than 3.6KW to the house when required?

    • @SolisNotSolis
      @SolisNotSolis 7 หลายเดือนก่อน

      Hi It is indeed. If its say a 5kW inverter but export limited to 3.6kW it will still supply the house at up to 5kW

    • @ChrisHearn-z4m
      @ChrisHearn-z4m 7 หลายเดือนก่อน

      @@SolisNotSolis That's what I was hoping - thanks