Welcome to RHVAC !
Anything related to Refrigeration, Heating, Ventilation & Air Conditioning :)
Anything related to Refrigeration, Heating, Ventilation & Air Conditioning :)
LG Multi V5 ARUM240LTE5 VRF C2 116 Error code
LG Multi V5 ARUM240LTE5 VRF C2 116 Error code
มุมมอง: 229
วีดีโอ
Mitsubishi Electric Water cooled HVRF PQRY-P300YLM-A1
มุมมอง 115หลายเดือนก่อน
Mitsubishi Electric Water cooled HVRF PQRY-P300YLM-A1 Dipswitch settings link: rhvac.com/blogs/view/10/mitsubishi-electric-water-cooled-hvrf-sw4-dipswitch-settings
Mitsubishi Electric City Multi PUMY-P140VKM1 ppm and Dipswitch readings
มุมมอง 2182 หลายเดือนก่อน
Mitsubishi Electric City Multi PUMY-P140VKM1 ppm and Dipswitch readings
Systemair VRF Test Mode and Function settings
มุมมอง 2002 หลายเดือนก่อน
Systemair VRF Test Mode and Function Settings SYSVRF AIR EVO HP R
Charge system Refrigerant using Recovery Unit and multiple Refrigerant Cylinders (purging)
มุมมอง 1603 หลายเดือนก่อน
Charge system Refrigerant using Recovery Unit and multiple Refrigerant Cylinders
How to Leak check or pressure test VRF/ VRV system
มุมมอง 1743 หลายเดือนก่อน
Fujitsu VRF VR-Il Series pressure testing
Fujitsu VRF VR-Il Series AJY108GALH Recovery Mode, Vacuum Mode
มุมมอง 5053 หลายเดือนก่อน
Fujitsu VRF VR-Il Series AJY108GALH Recovery Mode, Vacuum Mode
Daikin Madoka indoor unit status and Thermistor readings
มุมมอง 2304 หลายเดือนก่อน
Daikin Madoka indoor unit thermistor sensors readings
Mitsubishi Electric PAR Controller Request Codes (split units)
มุมมอง 3664 หลายเดือนก่อน
Mitsubishi Electric PAR-40MAA Controller Request Codes
Daikin SkyAir/ Seasonal Smart RZQG100L9V1B Emergency Mode Binary LED
มุมมอง 975 หลายเดือนก่อน
Daikin Seasonal Smart RZQG100L9V1B Emergency Cooling or Heating Mode
Daikin SkyAir / Seasonal Smart RZQG100L9V1B Recovery Mode Binary LED
มุมมอง 2155 หลายเดือนก่อน
Daikin Seasonal Smart RZQG100L9V1B Recovery Mode, Daikin SkyAir Recovery Mode
Comparing indoor and outdoor unit status on a healthy AC with a unit short of Refrigerant
มุมมอง 1.2K5 หลายเดือนก่อน
Comparing indoor and outdoor unit status on a healthy AC with a unit short of Refrigerant
Fujitsu UTG-UFYC-W Cassette Filter Reset
มุมมอง 7737 หลายเดือนก่อน
Fujitsu UTG-UFYC-W Cassette Filter Reset
Daikin VRV 4 or VRV 5 outdoor unit Function settings , identify Master or Slave units !
มุมมอง 4.3K7 หลายเดือนก่อน
Daikin VRV 4 or VRV 5 outdoor unit Function settings , identify Master or Slave units !
Fujitsu VRF VR-Il Series AJY108GALH Error E.A5.1 Low Pressure Abnormal EA51
มุมมอง 5298 หลายเดือนก่อน
Fujitsu VRF VR-Il Series AJY108GALH Error E.A5.1 Low Pressure Abnormal EA51
Clear Filter Change Alarm AL20 Airedale DFU
มุมมอง 1.1K10 หลายเดือนก่อน
Clear Filter Change Alarm AL20 Airedale DFU
Mitsubishi Electric Filter reset PAR-40MAA Controller
มุมมอง 93810 หลายเดือนก่อน
Mitsubishi Electric Filter reset PAR-40MAA Controller
Daikin Test Run, Filter Reset and indoor unit status and indoor thermistor reading BRC1E Controller
มุมมอง 5K11 หลายเดือนก่อน
Daikin Test Run, Filter Reset and indoor unit status and indoor thermistor reading BRC1E Controller
Unlock/ lock operation button Mitsubishi Electric PAR-40 Controller
มุมมอง 7Kปีที่แล้ว
Unlock/ lock operation button Mitsubishi Electric PAR-40 Controller
One question, is the VRV running ? Which port on the system (vrv) are you using to charge it ? Good work and clear explanation
The system was put in the Recovery Mode and then switched off from the main rotary isolator to be kept in the Recovery Mode so that all the Solenoid valves, Expansion Valves are kept open. You must do this if you want to Pressure test, vacuum or charge the system. To charge use the liquid service port and because of the system being in the Recovery mode the refrigerant will be running into all system. The Recovery Mode process is different for each system but this is how I put that Fujitsu VRF system in the Recovery mode: th-cam.com/video/JmrkmffPKX4/w-d-xo.htmlfeature=shared
Superb thank you👌
Welcome 😊
@@rhvac if you have any other tips please share thank you
Sure 👍
Good job 👍
Thanks 👍
What do you do to fix that starving indoor unit? is the eev defective?
Recovered the remaining refrigerant from the system and found a leak on the outdoor unit by pressure testing the system with Nitrogen. Repaired the leak and recharged the system 👍
How to vaccum and refill airdale crac unit , through indoor or outdoor bcoz solinaid valve and expansion valve or closed when Unit is off
Depending on the model, the Airedale Crac units usually have a DX condenser outside where the Compressor is located or some of them have the main components such as compressor, indoor and inside the Crac unit. You can connect the Manifold Gauge to the High and Low Pressure service ports of the compressor and use a Magnet to lift the Liquid Line solenoid valve open and recover the system refrigerant, vacuum , pressure test or charge the system 👍
How do I change the machine password and restore the old password?
You will need a high level user access password for that. Download the controller manual and you should be able to do that 👍
How about you fukin talk so we know what you are doing
My Th6 does not display the value and the air conditioner is not working after turn off "time to clean filter"
The TH6 is a sensor reading the Room temperature and in case of the Filter Reset, it will display an indicator when the period of cleaning filter is reached otherwise no need to turn it off.
Brother how to check expansion opening percentage in this remote
For checking the EEV opening status that is in Palses, you need a Service Checker as the controller unfortunately doesn’t display it.
❤
👍
Have a nice day Sir,, do you have a video,,how to reset VRV 3 or 4 or 5... I will wait your response 🙏🙏 God bless 🙏
Thanks 😊 In cases of your question, do you mean resetting the VRV after an Alarm!? Or do you mean the Controller password!?
@@rhvac resetting the VRV after an alarm
It depends what Error is, some Critical Error will stop and prevent the system from running until you fix the problem and then they will Auto Reset but some like Filter reset could be done via the Controller, I had posted a filter reset here: th-cam.com/video/H2vU2HS_ae8/w-d-xo.htmlfeature=shared Or here: th-cam.com/users/shorts4xEmlZmpMaE?feature=shared I will try to post more stuff about the VRVs 👍
You explaining is very nice sir? Upload more and more videos on vrv .
Sure I will 😊
Pouvez-vous traduire en français votre exposé. Merci d'avance François
Unfortunately I don’t speak 🇫🇷 but I suggest that you try to use some software that does French subtitles perhaps 🤔 Good luck 🤞
Mine says centrally controlled what do I do
It means you have a Master Controller that overrides the local controller. I assume that perhaps you have a VRF system with multiple indoor units with their controller and one Master Controller that restricts access level for the local controllers.
Hero 👏🏼
Glad was helpful 👍
Can I ask for a document to check the code table? thank
rhvac.com/blogs/view/7/vrv4-or-vrv5-outdoor-unit-monitoring-mode-setting-numbers
Thank
Can u upload the photo for this table
I am going to update the link for the photo 👍
The photo is uploaded 👍
Thanks
👍
i don't understand no 14.thanhks
Setting No 14 will tell you how many Branch Selectors are connected (BS Boxes). VRV outdoor units are piped into the BS Boxes and BS Boxes are branched connected to the indoor units. Check this: images.app.goo.gl/4u4p5vuf28M336Qq7
Great job👍
Thanks 👍
Details of the Request codes: rhvac.com/blogs/view/9/mitsubishi-electric-par-40maa-controler-request-codes
Есть такой же но по вайфай что бы работал?
As far as I know, you pair Madoka to the phone App by Bluetooth
Very nice video thanks. What happens in the unit that working sounds when you show the settings? It sounds like a valve is opening and closing. What is the event that takes place in that system?
The sounds in the background is when other DX Units Compressors loading and unloading. There are 4 DX units connected to each AHUs 👍
Unlock🔓 kesy kary
You can lock or unlock the options via the Madoka Assistant app on your phone 👍