Average Guy Videos
Average Guy Videos
  • 5
  • 21 902
Electrical outlet spacers
I tried out this product I found on Amazon. There are many brands or manufacturers of this type of spacer. I’m not advocating any of them. I’m only advocating the performance of this style of product.
Outlet Spacers for Electrical Box Extender Kit, Outlet Extender Easily Fix Switch Receptacle Spacers (30PCS) a.co/d/eGlWWat
มุมมอง: 161

วีดีโอ

Scag Tiger Cat transmission belt fix
มุมมอง 5K2 ปีที่แล้ว
Scag Tiger Cat 61 inch deck about 2014 (bought from previous home owner). The Hydraulic belt or Transmission belt jumped off the pulleys. It did not break, so I merely had to put it back on,…..after it cooled down. I am not a professional mechanic, this is just a informative video.
F150 lock actuator text and the real problem
มุมมอง 82 ปีที่แล้ว
The left rear door lock stopped working (neither FOB nor switch would work) but I could still manually lock/unlock it. I changed the actuator out to find it still didn’t work. First, I wanted to test the actuator from the car battery and this is how I did it. I added to the video with the actual problem at the end. My advice, check door wiring first before ordering parts. After finding the brok...
2016 Can Am Outlander 650 XT tie rod replacememt
มุมมอง 8173 ปีที่แล้ว
These are some tips and lessons learned from some other closely related videos I searched for. Hope it helps someone.
Replacing Gecko Spa Pak
มุมมอง 16K4 ปีที่แล้ว
This video is about Replacing Gecko Spa Pak

ความคิดเห็น

  • @joesteck6631
    @joesteck6631 3 หลายเดือนก่อน

    Thanks. I have the same machine 2013 model. Belt broke today and now I know how it goes back on. The problem will be finding the right belt tomorrow, Sunday.

    • @averageguyvideos2970
      @averageguyvideos2970 3 หลายเดือนก่อน

      If you have a local dealer, they will have the part number. Or if you have the manual still, it will have it. Amazon carries parts for Scags if you have the part number. Good luck.

    • @joesteck6631
      @joesteck6631 3 หลายเดือนก่อน

      Today is Sunday all dealers are closed so I’ll have to get one at Autozone and hope it’s correct. We have a real good Scag dealer here but not open until Monday am. I need to mow today.

  • @garyraines9839
    @garyraines9839 3 หลายเดือนก่อน

    I’m trying to figure out why mine won’t work a bunch of codes show up on the top board

    • @averageguyvideos2970
      @averageguyvideos2970 3 หลายเดือนก่อน

      The codes can be tricky. Most are universal to the brand but some features come with different codes. If you have the original manual, obviously you can use that to narrow it down. If you don’t have it, exhaustive internet search is all you have left without contacting a dealer or repair person. If your tub is having symptoms of an issue, I would research which part relates to that issue and see if a code matches to that part. It’s a process of elimination. Hope that helps somewhat.

  • @Spoolin_you
    @Spoolin_you 4 หลายเดือนก่อน

    Why does your video make me sign in and verify my age for explicit content? Might want to b***h to TH-cam about that one

  • @jacobnesloney2282
    @jacobnesloney2282 10 หลายเดือนก่อน

    Thank you very informative

  • @damamega
    @damamega 11 หลายเดือนก่อน

    How cant change my LL - program i have set the Wong

  • @sonnysnow7979
    @sonnysnow7979 ปีที่แล้ว

    Might sound like a dumb question, but what size belt did you use?

    • @averageguyvideos2970
      @averageguyvideos2970 ปีที่แล้ว

      I didn’t have to buy a belt (yet). It merely jumped off the pulley while I was mowing.

  • @thurmanandsonyardworks5932
    @thurmanandsonyardworks5932 ปีที่แล้ว

    Helps me man my broke today and had to tow through a landscape area at a hotel 😂 thanks for the vid helped tons

  • @billwilliams9897
    @billwilliams9897 ปีที่แล้ว

    Mine just broke this morning. Thanks for the vid

  • @Pete379Xra
    @Pete379Xra ปีที่แล้ว

    Thank you Average Guy, I have been all over TH-cam looking for trans belt replacement information and you were the only one on here. Thought I was going to have to take it to the dealer..That’s a scary thought. Thank you

    • @averageguyvideos2970
      @averageguyvideos2970 ปีที่แล้ว

      Im glad it was helpful. I only make videos when Im unable to find content as well. I encourage everyone to do the same.

  • @bman3020
    @bman3020 ปีที่แล้ว

    Good explanation. Easy way to move the idler pully with breakover bar in the square hole. Look at it like a socket hole. That is what it is for. Good video though.

  • @ssgveight
    @ssgveight 2 ปีที่แล้ว

    Just out of curiosity. My top side control panel gives me an HL error which based on my research means a high temperature issue at the heater element. Is that a similar issue as what you experienced? You mentioned an HR error. Not sure is that is the same thing.

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      Sorry it took me so long. I just saw this after an 84 hour week at work. My code was for the heating elements stopped working. Spa was not heating at all. If yours has been over heating, and I’m betting it would shut itself off to not damage the pak. Either that or one of your pump motors may be heating up under load and the pak is shutting it off. I’m not a pro at spas, but I did have to replace a pump motor because it would over heat and I can’t remember if it gave me an error code for it. I just kept noticing a pump would stop after so long and I had to wait till the next day before it was working again.

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      I really hope the video and this extra information helps.

    • @ssgveight
      @ssgveight 2 ปีที่แล้ว

      @@michaelwilliamson7531 No worries on the response delay. I’m sure you’re not sitting at your computer 24/7 checking for TH-cam questions. Lol. I appreciate the reply and the additional information. It’s already been helpful in figuring out the Spa Pack removal which should help me with troubleshooting. Thanks again and have a great day.

  • @ssgveight
    @ssgveight 2 ปีที่แล้ว

    This is awesome. I have been searching high and low for information on this spa pak. I also have a Dynasty Spa and the ID number on my Spa Pak is very close in number sequence to the one you pulled out of your spa. I have a feeling that you are about to save me a ton of money. Thank you for making this video.

  • @alanstendal2962
    @alanstendal2962 2 ปีที่แล้ว

    Thank you for documenting your repair. I learned a lot.

  • @constructor7774
    @constructor7774 2 ปีที่แล้ว

    How did you program it?

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      Sorry for the late reply. Been busy with Thanksgiving. It does not require programming itself. It does require you set the input Voltage (see about 10:21 minutes into video) for either 110 or 220 Volts. Other than that, programming the Spa is done on the top side control panel (temperature, run time, etc) and that will require the quick guide that comes with the top side control panel. If you don’t have it, then it will require some internet searching to find it. Once your enter the programming mode (which getting there is different depending on manufacturer) the settings show up as codes or abbreviations, so without the programming guide you would need to be an expert and have them memorized. I hope some of this helps.

  • @jimmccoy4913
    @jimmccoy4913 2 ปีที่แล้ว

    ‘Great video! By chance did you check the fuses inside of the connection box on the unit to see if any were blown?

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      Yes. I did some troubleshooting at the inside breaker, outside breaker as well. It all pointed to the spa pak and its still working great.

    • @jimmccoy4913
      @jimmccoy4913 2 ปีที่แล้ว

      Thank you for the reply. I'm not sure if I was clear about that. I was referring to the four small fuses inside the spa pack.

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      I checked the 3 fuses resting beside the 220V power connection inside the pak. If there were other fuses inside it, I was unaware.

    • @jimmccoy4913
      @jimmccoy4913 2 ปีที่แล้ว

      @@michaelwilliamson7531 Thank you. Yes, those were the fuses I was referring to. I'm installing a new power pack in my tub tomorrow. Thanks again!

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      Good luck Jim. I hope all goes well and something in my video gave you some clarity.

  • @DavidP-ru8bx
    @DavidP-ru8bx 3 ปีที่แล้ว

    Thanks for the video, replaced same on Dynasty spa. Found new colored plug trim pieces inside the power supply compartment of the replacement unit. I was surprised how much water flowed even with shut off valves closed. Good video.

  • @lstniceguy
    @lstniceguy 4 ปีที่แล้ว

    Hey where did you get the spa pac. I need the same one. Thank you for showing the old pac id its the same as mine. Thanks for the video.

    • @michaelwilliamson7531
      @michaelwilliamson7531 4 ปีที่แล้ว

      I believe it was Partswarehouse.com but if you take the new Parts ID, I would look for the best deal available with the best ratings. Hope that helps.

  • @ITDIR
    @ITDIR 4 ปีที่แล้ว

    Great video! A few questions: 1) Did your new Pack come with the same options? I ask because I'm having a heck of a time finding the same options of 1-2-K-K-D-60K-V2-DY1, 2) from what supplier did you get the replacement pack from?

    • @averageguyvideos2970
      @averageguyvideos2970 4 ปีที่แล้ว

      Hey Norm. Sorry it has taken so long to reply. Now that Im home more, due to the pandemic, my wife has a long list of things to do. The new unit did have the same options as well as the ability to upgrade with wireless control, which I did not order and plug in. Its been a while, but I'm almost positive it was DirectHotTubParts.com. There are slight differences in those pumps based on how many pumps you have and if any (or all) have multiple speeds. For instance, mine had 2 pumps and a blower. Pump 1 (2 speeds--low and high) and Pump 2 (1 speed only--high). Depending on your particular set up, read the description for the Gecko codes (mine was 0602-221063-299, I believe) and that best matched my setup based on the updated models. I also, cross referenced several sites to make sure that model would replace my older and no longer supported model because some sites will show that in the description and some will not. I hope this helps. Let me know if you there is anything else I can help with.

  • @stanleyhall2793
    @stanleyhall2793 4 ปีที่แล้ว

    Could you explain how you figured out that last part?

    • @averageguyvideos2970
      @averageguyvideos2970 4 ปีที่แล้ว

      I want to make sure I’m clear on what your asking, do you mean programming the top side panel?

    • @stanleyhall2793
      @stanleyhall2793 4 ปีที่แล้ว

      @@averageguyvideos2970 Thanks to your video I figured it out. I was asking about programming the top side.

    • @stanleyhall2793
      @stanleyhall2793 4 ปีที่แล้ว

      I really appreciate this video.

    • @tristinnapoleon7087
      @tristinnapoleon7087 3 ปีที่แล้ว

      How did you figure out 7 was what you needed when programming? I’m asking bc I’m have trouble getting pump 1 to turn on. I’m trying to figure out how to program in.xm2. Any info at the point would be much appreciated!! Thanks!

    • @michaelwilliamson7531
      @michaelwilliamson7531 2 ปีที่แล้ว

      @@tristinnapoleon7087 I apologize. I’m not sure how I missed the notification of your post. I can only hope you found the answer to your question after all this time. If The P1 connection is not loose on the Spa Pak and the top side control panel shows it’s trying to engage the pump, my only thought is the pump itself.