Fitting Shelly wifi to Dumb ev charger Rolec or others to give timed charging
This Shows the use of the Shelly wifi switch to give timed control to a dumb rolec charger . the same princaple can be used to do the same with just about any EV charger . this will alow you to use your mobile phone or any device with web browser that can conect to your network to set times of charge on the device .. this device can also as brought can be used with a Mqqt server for control / as well as Alexa etc
มุมมอง: 6 972

วีดีโอ

Fit Modified Sonoff to EV charger
มุมมอง 1.2K4 ปีที่แล้ว
This is a short vid to show how to conect the Modified Sonoff wifi switch to a Dumb EV charger the same can be done to other chargers eg rolec that dont give timed charge . this mod will wake up the MG ZS EV to charge . link to the mod vid th-cam.com/video/ywtjnx8cNGU/w-d-xo.html
Sonoff mod to volt free contact
มุมมอง 11K4 ปีที่แล้ว
This is how i modifie a sonoff wifi switch to give a volt free contact output this lets me use this device to control many other devices that have a low voltage control circuit or a circuit that needs isolation from mains voltage this will now let this device to be used to upgrade simple dumb EV chargers to timed chargers or even some smart chargers that for some reason do not want to do timed ...
what happens if you hold off power to on board charger on mg zs ev
มุมมอง 2734 ปีที่แล้ว
we try delay start by holding of the ac power to the car when it requsts it . also demonstration of my prototpe MG Wake up board on a dumb rolec charger
rolec charge control this gives ajustment of charge Amps to the car MG zs EV
มุมมอง 2.4K4 ปีที่แล้ว
this showes how to modifie the output current from a dumb Rolec charger with a variable 1kohm resistor
test of upgraded rolec on mg zs ev doing a timed charge using Sonoff relay
มุมมอง 1.3K4 ปีที่แล้ว
This is showing first actual test of the Modded rolec Dumb charger to delay charge my MG ZS EV we are using a sonoff relay to enable the charger control modual when we want to charge . this gives wifi accsess over the internet . and works note the sonoff relay needs to be set to remember its last state in case of a mains fail so it will come back the same as it was befor the mains fail
rolec mods part 2 MG ZS EV compatble
มุมมอง 1.5K4 ปีที่แล้ว
this is part 2 of 2 parts here i show the fitting of the Sonoff modual to a dumb rolec EV charger to give it a time shedule and on off control via the mobile phone . given time i hope to follow this up with a further vid showing it oprating on the MG ZS EV and other posable mods that could be done
Rolec mods part 1 MG ZS EV compatable
มุมมอง 4194 ปีที่แล้ว
This is part 1 of 2 showing how to make a rolec dumb charger into a timed charger using a sonoff device to give a time shedual for charging on / off control or it can be set up to use alex and other voice oprated systems here i take my first look and carry out some tests on the basic unit if you want to see just the mod only then load part 2 . the charger was kindly donated by a member of the M...
MG ZS EV Problem delayed charge THE Corcuit Diagram sort off
มุมมอง 3514 ปีที่แล้ว
Hi this is showing the circuit diagram to build what I have used to solve the charging problem with my MG . This is what I have tested in the other vids . It has been put on my charger today and I will be using it this week so I will give any feed back that I find but so far so good . I describe how the circuit works . I will try and find out how to put a link to a pdf this week of this diagram...
MG ZS EV part 6 delay charging problem
มุมมอง 2684 ปีที่แล้ว
Here we show the result of unlocking the car while charging . The next vid I will show the circuit diagram of the interface to allow the aurdino uno to do its thing and make this car do a delayed charge .
MG ZS EV. Timed charging problem part 4 delayed charge
มุมมอง 2774 ปีที่แล้ว
This gives a look at the car being woken up by the board. I have added a few other lines of code to the program to allows the possibility of the car terminating the charge . Then at a later time asking for more power pos due to preheat . Even though the mg does not have this I still need to think of other cars that may .
MG ZS EV delay charging part 4
มุมมอง 714 ปีที่แล้ว
Vid of the first timed test after car fall asleep it get a quick boot to wake it up Looking good so far .
MG ZS EV. Timed charge solution part 3
มุมมอง 3014 ปีที่แล้ว
This is the on bench test of an audino uno based solution . It inserts a relay contact in the pilot wire going to the car . And if it detects that the MG is not responding to a charge instruction from the charger it will open the pilot signal and reset the car the same as if you had just plugged it in More vid and information to follow
MG ZS EV timed charge problem Part 2 showing car fail to charge
มุมมอง 5084 ปีที่แล้ว
This shows the MG ZS EV falling asleep and failing to wake up to a timed charge. Also a possible solution ?
MG ZS EV. Timed Charge problem part 1 showing what should happen
มุมมอง 7554 ปีที่แล้ว
This is part one of a two part vid showing why the MG is struggling to work with most EV chargers Note my ref to the point line should have been the pilot line This is all measured to ground
Sun-2000 grid tie remote limiting 1000m upgrade from 30 m as standard
มุมมอง 3.2K4 ปีที่แล้ว
Sun-2000 grid tie remote limiting 1000m upgrade from 30 m as standard
Longwei bench power supply fail
มุมมอง 7524 ปีที่แล้ว
Longwei bench power supply fail
Generater test
มุมมอง 218 ปีที่แล้ว
Generater test

ความคิดเห็น

  • @AdvancedTech2sharp
    @AdvancedTech2sharp 3 หลายเดือนก่อน

    After Modification, to which terminals will the Motor be connected ( Relay Terminals Or the Initial Output Terminals)?

  • @AdvancedTech2sharp
    @AdvancedTech2sharp 3 หลายเดือนก่อน

    Which of the Sonoff requires no Modifications?

  • @mickcup7783
    @mickcup7783 6 หลายเดือนก่อน

    Hi, I have an EO mini charger, I have two wires from the plug side to the car, I have used the Shelly 1, but I can turn it on but it won't shut off, it makes the clicking noise but it does not shut off, van you please advise.

  • @tomnielsen3233
    @tomnielsen3233 9 หลายเดือนก่อน

    can i do the sam thing with the shelly 1pm insted ?? the inled on the device are not simular !

  • @kevinregan5125
    @kevinregan5125 9 หลายเดือนก่อน

    Hi, I have a QUBEV Mk1, also made by Rolec and I'm getting my sparks to instal a Shelly relay. Is the layout much different? There's space enough but maybe the connections differ, so a little help is appreciated :) Especially as the night rate of 9p is a lot better that 32p but getting out at 00:30 to plug in manually is not appealing in winter! :)

  • @barryhaeger4284
    @barryhaeger4284 ปีที่แล้ว

    I've used the Relay Version and it can be powered on 12v DC or 5v via the USB. I've installed it to interup the CP live to the tethered cable and picked off 12V DC off the 12 V pins on PodPoint Solo

  • @RichSimpson
    @RichSimpson ปีที่แล้ว

    Very interesting. Did you complete the install. What if the resistor is at 100% open, still safe at 32a? Any way to remote control this with something wifi based? Would be great to control my rolec 32a dumb charger for the charge rate remotely, so I could use my excess solar to dictate the value using Node Red or Home Assistant instead of a manual knob to turn. Though the manual option is still worth pursuing if no better solutions.

  • @chrisminns1604
    @chrisminns1604 ปีที่แล้ว

    Hi I have a rolec smart charger and the EV app will not let me set a time for off peak electric, can I use a Shelly 1 on the smart charger, it's an untethered charger thanks

  • @jamesw6698
    @jamesw6698 ปีที่แล้ว

    Great video. Wondering why you chose the CP connection rather than cutting the live feed to the control module itself? Controlling the CP wire means the LED indicators will continually flash when the charger is not in use. Although minimal, the flashing LED is consuming power. Controlling the live to the module would power off the control module, and just keep the charger in a state of readiness for when the module is powered up. Maybe this method would cause damage or issues though?

  • @deanwade5611
    @deanwade5611 2 ปีที่แล้ว

    Hi, do you have details of the resistor values required for each of the 6, 12, 18, 24, 30 & 32A charging currents [on your Duty cycle - charge amps table], please?

  • @z3nogaming329
    @z3nogaming329 2 ปีที่แล้ว

    Hello,can i contact you?

  • @obijuan-
    @obijuan- 2 ปีที่แล้ว

    Very good video on mod for Sonoff Basic. I just completed the same for my Basic RFR2. Now, I have it attached to my GDO and can also use a 433 MHz remote to open/close the door. Of course it also have voice and manual operation.

  • @tomnielsen3233
    @tomnielsen3233 2 ปีที่แล้ว

    super video ! butt i have bought an shelly 1pm and on that device the terminals are numbered/named different ! how do i connect that one ??

  • @kimhammerum132
    @kimhammerum132 2 ปีที่แล้ว

    Good safety - much apprecierede you making the video available for us. Thanks buddy...!

  • @akohn09
    @akohn09 2 ปีที่แล้ว

    Its interesting, do ypu know if there is a simular solution to the EO Mini (not pro)?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      I would expect this to work with all chargers. As they all work the same way with the protocol.

  • @matthewbyrne8196
    @matthewbyrne8196 3 ปีที่แล้ว

    Wired this up to my rolec untethered unit. I've interrupted the proximity pilot pin. It works perfectly at telling my rolec to initiate charge because the car is connected to it, by while during an ongoing charge if I make the Shelly an open circuit, it doesn't disengage the charge session. Very weird

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Sorry for late response. When you say proximity pilot pin Are you sure you are on the correct pin as on a untertherd unit I would also expect to see a second control wire that is connected to the lead skt. This connects to a sense resistor in the lead Handel and this resistor tells the controler the maximum power that the lead can Handel. I have not tried intrupting this but I have fitted a variable resistor to it on an old rolec. It made it current adjustable. Output but other controlers respond diferantly Have you conected to this line and not the pilot co pin

    • @matthewbyrne8196
      @matthewbyrne8196 2 ปีที่แล้ว

      @@hotrex7779 yup. That second wire is there alright. Odd behaviour from the car/charger

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      @@matthewbyrne8196 have you tried fitting the device in the other wire as what you are describing should not happen . I think you are not connected into the pilot control wire

    • @matthewbyrne8196
      @matthewbyrne8196 2 ปีที่แล้ว

      @@hotrex7779 I could do, but I am using the pilot control wire. The control pilot pin location for the untethered unit won't be different. It's a type 2 standard.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Then it’s is well strange as the car would be monitoring the pwm signal continually And adjust the charge rate dependent on the pwm. If it sees the pwm signal removed and the pilot signal voltage removed the car should stop charging at once as it is also a safety if the lead is pulled out this contact opens first . Again the charger unit should also remove mains voltage from the car in the event that this signal is lost . Very strange. Events.

  • @id3byunclet359
    @id3byunclet359 3 ปีที่แล้ว

    Many thanks I have an old dumb Charge master cp. This will solve so many problems. I can't identify a 12v supply within the Charge master to power the Shelly so will have to use the 240v. Eg Shelley unit power L / N 240v. Chargmaster control thin black wire switched through the Shelley i / O on the low voltage side. Is this correct as I need those beer tokens

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Yes I have used this motors also this is the way I have shown the modified sonoff device fitted

  • @NikAtFL390
    @NikAtFL390 3 ปีที่แล้ว

    Hi Skipp, Hope this finds you well, My 6 month old Sonoff basic R2 konked off ... I tried changing the relay, but it will not budge, it will not come back on (sadly the original relay broke off while desoldering it out) (Also there is no glass fuse, its seems to be a 5 band 10 Ohms 5% resistor in its place inside a heat shrink tube).. Anyhow Funny though 5 other Sonoff basic R2's switches have been working for over three years perfectly well ... And this new unit circuit broke and I cannot figure what component has popped. ... I'd be totally thankful if you could guide me on how to fix this.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Sorry. Late reply. I have to date not had to repair any of my devices . So can’t realy say what fails. Normal checks would be to test for voltages at the chips and the relay driver device

  • @peterg7347
    @peterg7347 3 ปีที่แล้ว

    The Shelley switch is only rated to 3.5kw so how is it safe for a 7kw Rolec?

    • @matthewbyrne8196
      @matthewbyrne8196 3 ปีที่แล้ว

      It's not controlling 7kW, it's only controlling a signal pin

  • @davidallender2872
    @davidallender2872 3 ปีที่แล้ว

    Excellent video this. Did this mod in a Qubev dumb charger and works a treat!! Sod paying through the nose for a smart charger. All you need is a good electrician and buy the kit yourself. Government grant fitting is a gigantic rip off!!

  • @iPeel
    @iPeel 3 ปีที่แล้ว

    On my timeswitch I connect the normally closed contact to a 1k resistor connected to the 12v output. Instead of the CP line being open circuit this makes the car believe it's connected to an EVSE in standby mode.

    • @trevdfield7520
      @trevdfield7520 3 ปีที่แล้ว

      Am I right in thinking you put the 1k between the i and o on the shelly switch side lowering the sensor voltage? Do you know if this wiĺl work on a chargemaster cp?

    • @iPeel
      @iPeel 3 ปีที่แล้ว

      @@trevdfield7520 the relay switch should have common, normally closed and normally open contacts. Common goes to the CP line out to the plug, normally open goes to the CP on the EVSE, then the 1k resistor goes between a 12v supply ( possibly on the EVSE controller ) and the normally closed pin of the relay switch.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Hi. What car is it that you are using this on ? I can see that the car will think it’s connected to a charger . Does the car not respond to this signal and try to initiate a charge ? . The method I used was aimed at the MG ev. That needed this. To wake it up from sleep mode. But an interesting adaption

    • @iPeel
      @iPeel 2 ปีที่แล้ว

      @@hotrex7779 my car's a Renault Zoe but it should work with any car, it imitates the specification a unit in standby would use so the car should not attempt to start a charge but wait for the EVSE to become available. Even if it did it wouldn't be successful as the CP line to the EVSE is interrupted with the dummy 12v supply.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      @@iPeel it would be intresting to see how the Mg would respond to it. As the latest software that I tested a while ago would allow a delayed start. Ie. Give 12 volt car would pull down to 9 volt. Charger would delay giving pwm output until charge start time then car would start charge. But once this had been done once and charge was stoped by charger removing pwm signal. Then car would not start a charge again until the 12 volt had been removed. Or taken to -12volt for an extended time to reset. This is the way the omie charger remakes the Mg. ..

  • @ybpvin
    @ybpvin 3 ปีที่แล้ว

    Дякую, потрібна інформація. Лайк!

  • @brucet000
    @brucet000 3 ปีที่แล้ว

    @hotrex7 Am I right in assuming this will, when wired like this, will 'wake up' my MG ZS EV, like your video on the modified Sonos?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Sorry late reply. Yes it is just the same

  • @hyunwoo
    @hyunwoo 3 ปีที่แล้ว

    does 16A mean it wont work for a 32A EVE?

    • @brucet000
      @brucet000 3 ปีที่แล้ว

      Ken, I think because you aren't using the shelly as the main relay it will work on a 32A Rolec, I've use a 32A one and I'm going to fit one as soon as I get a shelly

  • @brtknr
    @brtknr 3 ปีที่แล้ว

    Thanks for the video. I was looking for any clues as to why my mode 3 controller is playing up. Do you what it does?

  • @lucclaes6270
    @lucclaes6270 3 ปีที่แล้ว

    Why modifie the Sonoff? Just add a extra relais (110 or 230V) at the output for the same result.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      True. Some ppl have done this too . But for me I use this way to keep things simple and under one cover. I only drive external relays and contactors. If I need to control a larger current load . But I would advise ppl to do what they feel comfortable with and understand.

  • @emanuelortiz3667
    @emanuelortiz3667 3 ปีที่แล้ว

    Can I used this modification to run a 12v dc motor?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      This. Gives a volt free contact that you can use to control any other device by controlling an external voltage source. Just be aware of the Amps limitation of the relay I would myself only run these relays at 50% load. For a longer life.

  • @GTRDRIVER1
    @GTRDRIVER1 3 ปีที่แล้ว

    Hi - i have some questions: Im right that you using a 5V PWM Signal - to controll the Power output of the Inverter - wich PWM Frequency do you use ? - do you have connected it to the external or internal Connector of the Inverter ?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Sorry. I did not get any notification of your . Just seen it today. The signal that comes from the external limit controler is a pwm signal. At 1 hz. At 5 volts dc the pwm does not seem to be directly related to output power in a 0 to 100%. Relation ship but more of a up / down in power level as the pwm. Goes above and below 2 duration limits as far as I could see .

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Sorry feeding into external

  • @captainmark1
    @captainmark1 3 ปีที่แล้ว

    Hi Do you sell these devices? I've got a tattered Rolec..

  • @captainmark1
    @captainmark1 3 ปีที่แล้ว

    Hi, I found this type on ebay is it the same? Shelly 1 -3.kw 230/16A ???

  • @andrealub77
    @andrealub77 3 ปีที่แล้ว

    Great work. You could use a Shelly EM to have this feature and also the power monitoring and history. Moreover you could use power monitoring with another one placed on the house to trigger a disconnection in case of too much power pulled. I have done this in my house to disconnect AC and send an alarm before total disconnection.

  • @ELIYATKIN
    @ELIYATKIN 3 ปีที่แล้ว

    th-cam.com/video/lKVcYH3kW-o/w-d-xo.html

  • @GoGreenAutos
    @GoGreenAutos 3 ปีที่แล้ว

    Thanks for making this video. I didn't realise such a device existing. Perfect for what I need to add timed charging to an old Rolec charger.

    • @hotrex7779
      @hotrex7779 3 ปีที่แล้ว

      No problem that the whole point to show how easy to get it to work without scrapping a good charger saves the environment. But more important saves beer tokens

  • @stuart4176
    @stuart4176 3 ปีที่แล้ว

    Great video, any change of doing one sometime using a 7 kwh old chargemaster home unit, using one of these, Must be quite a few still working but not able to take a smart charge.

    • @hotrex7779
      @hotrex7779 3 ปีที่แล้ว

      It is the same way just identified the pilot line if not sure send me some good picture of circuit board and wires I will try point you in the right direction

  • @timcx
    @timcx 3 ปีที่แล้ว

    Thanks very useful video, quick question what are the crimp-on connectors you use called, they look very neat.

  • @cloudsuck
    @cloudsuck 3 ปีที่แล้ว

    Suggestion for a slightly simpler way to do this mod. All of these steps are done on the non-component side of the SonOff Basic R2. 1) De-solder relay output wire to Neutral terminal (as you did). 2) Cut entirely through the pc board/trace at the point that is common between the fuse lead, and the relay output lead. 3) Route the de-soldered relay output wire from "step 1)" into the pc board's corner notch, and solder it to the relay output solder pad from "step 2)". Confirm that there is no continuity between mains/input terminals and output terminals. No need to drill holes, or relocate the fuse. Just one through cut of the pc board.

    • @erdemgin
      @erdemgin 3 ปีที่แล้ว

      video?

    • @emanuelortiz3667
      @emanuelortiz3667 3 ปีที่แล้ว

      Video?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Thanks for this feed back I will have a look next time I modify one. And try this see if I Like it Thanks

    • @cloudsuck
      @cloudsuck 2 ปีที่แล้ว

      @@emanuelortiz3667 th-cam.com/video/zpuJ-BpDvpU/w-d-xo.html Or th-cam.com/users/shortsY-3EADnFtZ8

    • @kaib9203
      @kaib9203 2 ปีที่แล้ว

      The best comment of all. One more modification: no need to desolder relay output wire. Just clip at the base. See modified pc board: drive.google.com/file/d/1f8e6tSo0xO5eKkBqah9tm0bMX9CBDVor/view?usp=sharing

  • @martinvrabec4701
    @martinvrabec4701 3 ปีที่แล้ว

    is it possible to operate also 230V on the output?

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      If you mean to control an external 230 v signal from some other device. Yes you can Note if you are switching. Dc. Then the current limit needs to be reduced. To prob only 2 amps it less

  • @1didthis
    @1didthis 3 ปีที่แล้ว

    Brilliant and thank you. Just ordered mine.

  • @chrissoar8000
    @chrissoar8000 3 ปีที่แล้ว

    Got mine ordered this morning. Thanks for the great info.

  • @RobertP7884
    @RobertP7884 3 ปีที่แล้ว

    Another great way to smart your dumb charger and such small device is a winner

  • @kingming3738
    @kingming3738 3 ปีที่แล้ว

    Wonderful!!

  • @richardbijlard5092
    @richardbijlard5092 3 ปีที่แล้ว

    Excellent demonstration...helpfull! thanks!

  • @db7818
    @db7818 3 ปีที่แล้ว

    Hi Bill, I’m very thankful for your great contribution on to how to resolve the issue that Rolec home charger and MG ZS EV have with scheduled charging. In particular I’m very interested in “MG Wake Up Board” that you made and demonstrated in your video. Is it possible to buy one from you so I can set it up within my Rolec home charger? I’d rather use your solution then Sonof smart Wi-Fi switch as my Wi-Fi signal is not good where the charger is.

    • @hotrex7779
      @hotrex7779 3 ปีที่แล้ว

      Hi. Drop me a mail to billburgess42@hotmail.com. What rolec do you have ? And if it is used for the MG the latest software will now let you charge with a single delayed charge up to 10 hrs. If you want to use agile tarrif then you need the wake up board

  • @JmChannel25
    @JmChannel25 3 ปีที่แล้ว

    I like your method. Moving the fuse makes this mod much safer. 👍

  • @MsDebc
    @MsDebc 4 ปีที่แล้ว

    Good stuff, thanks (despite the vertical video 😉) . I think I'll do this and use Home Assistant with AlexxIT/sonoff so can integrate with Octopus Agile ToU tariff. Could also use the sonoff but cut the traces to make volt free and then use instead of the 5v powered board but without need for 5v supply? Edit: just seen the subsequent video 👍🏻

    • @hotrex7779
      @hotrex7779 3 ปีที่แล้ว

      Yes I got the vid wrong. That’s the fun of using an iPhone

  • @MsDebc
    @MsDebc 4 ปีที่แล้ว

    Useful, thanks. Would be improved by the video not being vertical

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Yes. Sorry about that using a iPhone and did not realise it did it in that format.

  • @stuartmacer7192
    @stuartmacer7192 4 ปีที่แล้ว

    great vids, its there a way of buying this modified sonoff wifi switch ?

    • @hotrex7779
      @hotrex7779 3 ปีที่แล้ว

      Sorry only just see this. You can use a Shelly wife device. This comes standard with volt free contact . Or I can send you a device that I will mod. If you still need it

  • @smartassan
    @smartassan 4 ปีที่แล้ว

    That was a really clear explanation. Thank you.

  • @slinuk
    @slinuk 4 ปีที่แล้ว

    Hi Mate, I have a 32A rolec charger what sort of fixed resister I should be using? 220 ohms? What eating? Advice will be greatly appreciated.

    • @hotrex7779
      @hotrex7779 2 ปีที่แล้ว

      Hi on my rolec with a tethered lead the connection has no input to the input and defaults to 32 amp

  • @AgraMFZ
    @AgraMFZ 4 ปีที่แล้ว

    Hi, I am searching for this information since 2 years... are you able to provide more Details regarding the PWM signal? I like to meassure the power consumption of my house via an industrial Smart Meter and send all necessary information via a RS485 wireless connection from my house to a 100m distance. I like to use the EEM Power Meter and Radioline modules from Phoenix Contact. They are easy to use. On the Location where the Inverter is installed I like to use a PLC to convert the signal to the inverter and to provide a WLAN network with a cloud monitoring. For that I like to use the Phoenix Contact AXC 1050 Controller with IO cards. These things are alle steardy.

    • @hotrex7779
      @hotrex7779 4 ปีที่แล้ว

      Hi. The pwm signal is a 5 volt pwm. At 1 hz the unit does not seem to respond in a liner fashion to this signal but seems to ramp up as it go’s over about 70%. And ramps down as the pwm drops to about 40%. Hope this helps Bill

    • @AgraMFZ
      @AgraMFZ 4 ปีที่แล้ว

      @@hotrex7779 Thank you Bill! I will check that out... ;)

    • @hotrex7779
      @hotrex7779 4 ปีที่แล้ว

      Benjamin Klimmek If you need the circuit diagram I would have to draw it up from my notes. My one is a bit more than need for one unit as I drive 4 inverters from same signal but all are options isolated from each other.

    • @AgraMFZ
      @AgraMFZ 4 ปีที่แล้ว

      @@hotrex7779 Thanks for your friendly support. But I like to integrate all in a PLC with Wireless solution and a Smart Meter using Modbus TCP. 😉