42- Unboxing and assembling a Siemens Cellular Router
In this video, we walk you through the essential components needed to provide internet to a machine or a plant using a cellular network. Watch as we unbox and assemble each part, making it easy for you to set up your own cellular internet connection.
This router can be used instead of the WiFi client module we discussed in a previous video to remotely access PLCs, HMIs, VFDs, and more using the Sinema RC VPN solution. If you're working on an project that needs remote connectivity, this guide has you covered!
มุมมอง: 140

วีดีโอ

41- OT Data Integration with Open-Source Projects: Tutorial & Discussion on OPC UA, MQTT, UNS & more
มุมมอง 28621 วันที่ผ่านมา
Andreas Vogler's open-source project, "Frankenstein Gateway," is an excellent tool for bridging the gap between IT and OT data. It is a personal project completed in his spare part. This gateway aggregates OT data from various sources, such as PLCs with legacy protocols like Modbus, OPC UA servers, and MQTT brokers, into a single platform. It allows the IT team to access the aggregated data thr...
40- How to Connect a Siemens LOGO to Home Assistant as an MQTT Sensor?
มุมมอง 74028 วันที่ผ่านมา
In previous videos, we learned how to use the Siemens LOGO mini PLC to publish data to a local MQTT broker. In this video, we'll show you how to integrate a LOGO with Home Assistant, the most popular open-source smart home platform, as an MQTT sensor. Here's what to expect in this tutorial: A quick introduction to Home Assistant An overview of the utilized hardware Configuration of Home Assista...
39- Integrate Arduino Shields with Siemens IOT2050 or IOT2040 & Node-Red for Controlling a Fan
มุมมอง 7663 หลายเดือนก่อน
Modularity and hardware/software compatibility are among the most important features of an IoT device. In our latest video, we demonstrate just how straightforward it is to integrate an Arduino Uno relay shield with Siemens IOT2050 or IOT2040 devices for real-world interfacing. Additionally, we showcase the use of Node-Red for testing the integration and provide a step-by-step guide on controll...
38- Siemens LOGO PLC Masterclass. Part 1: Wiring, obtaining the software, Overview of the menus
มุมมอง 2.5K3 หลายเดือนก่อน
38- Siemens LOGO PLC Masterclass. Part 1: Wiring, obtaining the software, Overview of the menus
37- Minimize IoT System Downtime: Complete Tutorial on MQTT Clustering with Live Demo on Real HW
มุมมอง 6224 หลายเดือนก่อน
37- Minimize IoT System Downtime: Complete Tutorial on MQTT Clustering with Live Demo on Real HW
36- Unlocking Next-Level IIoT: Getting started with EMQX MQTT Broker on a Siemens IOT2050!
มุมมอง 1.5K4 หลายเดือนก่อน
36- Unlocking Next-Level IIoT: Getting started with EMQX MQTT Broker on a Siemens IOT2050!
35- All you need to know about the new Siemens HMI, Unified Basic Panel (UBP)
มุมมอง 2.1K4 หลายเดือนก่อน
35- All you need to know about the new Siemens HMI, Unified Basic Panel (UBP)
34- The Ultimate Machine Automation: Siemens LOGO! with MQTT, InfluxDB, and Grafana Integration
มุมมอง 2.3K4 หลายเดือนก่อน
34- The Ultimate Machine Automation: Siemens LOGO! with MQTT, InfluxDB, and Grafana Integration
33- How to Control a Siemens S210 Servo Drive with a S7-1500 PLC? A complete Tutorial
มุมมอง 3.2K5 หลายเดือนก่อน
33- How to Control a Siemens S210 Servo Drive with a S7-1500 PLC? A complete Tutorial
32- Mastering Event-Driven Email Notifications with Siemens LOGO V8.4: Complete Tutorial & Live Demo
มุมมอง 2.5K5 หลายเดือนก่อน
32- Mastering Event-Driven Email Notifications with Siemens LOGO V8.4: Complete Tutorial & Live Demo
31- Siemens LOGO V8.4: Unboxing & Live Demo of Bi-Directional MQTT Communication with Raspberry Pi 5
มุมมอง 4.6K5 หลายเดือนก่อน
31- Siemens LOGO V8.4: Unboxing & Live Demo of Bi-Directional MQTT Communication with Raspberry Pi 5
30- IoT Masterclass, Part 5: Storing Raspberry Pi Pico W data in InfluxDB & visualizing on Grafana
มุมมอง 8535 หลายเดือนก่อน
30- IoT Masterclass, Part 5: Storing Raspberry Pi Pico W data in InfluxDB & visualizing on Grafana
29- Using Siemens WinCC Unified Runtime manager API: Introducing UPS for Enhanced Project Management
มุมมอง 6386 หลายเดือนก่อน
29- Using Siemens WinCC Unified Runtime manager API: Introducing UPS for Enhanced Project Management
28- Access Remote Plants or Machines with Siemens SINEMA RC! A complete Beginner's Guide & Live Demo
มุมมอง 1.4K6 หลายเดือนก่อน
28- Access Remote Plants or Machines with Siemens SINEMA RC! A complete Beginner's Guide & Live Demo
27- Siemens LOGO! V8.4 Now Supports Azure, Alibaba and AWS Clouds and Any MQTT Broker!!
มุมมอง 7K7 หลายเดือนก่อน
27- Siemens LOGO! V8.4 Now Supports Azure, Alibaba and AWS Clouds and Any MQTT Broker!!
26- IoT Masterclass, Part4: MQTT Communication in Siemens Unified HMI Panel using Node-Red Edge App
มุมมอง 1.4K7 หลายเดือนก่อน
26- IoT Masterclass, Part4: MQTT Communication in Siemens Unified HMI Panel using Node-Red Edge App
25- IoT Masterclass, Part3: Programming a Siemens PLC to Publish/Subscribe to MQTT Topics
มุมมอง 4.2K8 หลายเดือนก่อน
25- IoT Masterclass, Part3: Programming a Siemens PLC to Publish/Subscribe to MQTT Topics
24- IoT Masterclass, Part 2: Python Programming and Sensor Data Storage and Visualization
มุมมอง 1.2K8 หลายเดือนก่อน
24- IoT Masterclass, Part 2: Python Programming and Sensor Data Storage and Visualization
23- IoT Masterclass, Part 1: Unbox a Raspberry Pi 5 and Software Installations
มุมมอง 1.7K8 หลายเดือนก่อน
23- IoT Masterclass, Part 1: Unbox a Raspberry Pi 5 and Software Installations
22- Connecting an RFID Reader to a Siemens Unified Comfort Panel HMI
มุมมอง 2.2K8 หลายเดือนก่อน
22- Connecting an RFID Reader to a Siemens Unified Comfort Panel HMI
21- Siemens PLC Redundancy & High Availability: From Basics to TIA Portal Setup and Real HW Test!
มุมมอง 5K9 หลายเดือนก่อน
21- Siemens PLC Redundancy & High Availability: From Basics to TIA Portal Setup and Real HW Test!
20- Migrate Siemens ET 200S to ET 200SP with TIA Selection Tool | Quick Migration Guide!
มุมมอง 94410 หลายเดือนก่อน
20- Migrate Siemens ET 200S to ET 200SP with TIA Selection Tool | Quick Migration Guide!
19- Analyze a Complex TIA Portal PLC project in the new SIMATIC Project Insight for FREE!
มุมมอง 1Kปีที่แล้ว
19- Analyze a Complex TIA Portal PLC project in the new SIMATIC Project Insight for FREE!
18- Siemens IoT2050 IoT Gateway Tutorial: Running a Python Dashboard for Industrial IoT
มุมมอง 7Kปีที่แล้ว
18- Siemens IoT2050 IoT Gateway Tutorial: Running a Python Dashboard for Industrial IoT
17- Hand Gestures Interaction with a PLC, HMI and Automation system using Machine Learning
มุมมอง 1.2Kปีที่แล้ว
17- Hand Gestures Interaction with a PLC, HMI and Automation system using Machine Learning
16- Voice Interaction with a PLC and HMI Using Python
มุมมอง 1.6Kปีที่แล้ว
16- Voice Interaction with a PLC and HMI Using Python
15- Getting started with Siemens Safety PLCs. Learn through a real-life example & physical hardware
มุมมอง 1.5Kปีที่แล้ว
15- Getting started with Siemens Safety PLCs. Learn through a real-life example & physical hardware
14- All you need to know about S7-1500 Integrated HMI, View of Things (VoT)
มุมมอง 541ปีที่แล้ว
14- All you need to know about S7-1500 Integrated HMI, View of Things (VoT)
13- Mastering Siemens HMI Panels: A Selection Guide and Comprehensive Tutorial on HW and SW
มุมมอง 1.1Kปีที่แล้ว
13- Mastering Siemens HMI Panels: A Selection Guide and Comprehensive Tutorial on HW and SW

ความคิดเห็น

  • @leosdospel863
    @leosdospel863 2 วันที่ผ่านมา

    Hello Thanks for video. Is it possible to have redundant ET200SP with non redundant CPU? Thanks

    • @blociot
      @blociot วันที่ผ่านมา

      I hope it was useful. To my knowledge, you can connect redundant I/O to non-redundant CPUs in PCS7, but there are limitations and considerations. For instance, using redundant Modbus TCP/IP on PCS7 to communicate with non-redundant PLCs is possible but sub-optimal. Additionally, for true redundancy, you would need specific hardware configurations such as HF Interface Modules and S2 PROFINET features to ensure proper communication and avoid single points of failure. Without these, redundancy may not be fully achieved.

  • @francisgremillet3894
    @francisgremillet3894 5 วันที่ผ่านมา

    Hi, Nice video! But you don’t necesserally need a T (Technology) CPU at all to control a servo-drive. The T CPU are requested for very complex applications or when number of servo-drives exceeds CPU calculation capacities (absolute sync axis, caming, winders, …)

    • @blociot
      @blociot 5 วันที่ผ่านมา

      @@francisgremillet3894 thank you for the feedback. You don't have to use a T CPU for simple servo control. But with the technology CPUs (T-CPU) you can efficiently automate complex multi-axis systems and kinematics. With the "cross-PLC synchronous operation" function available in all T-CPUs, gear and cam synchronization can also be realized across CPUs, so that there are nearly no limits to the axis quantity.

  • @serjonik9973
    @serjonik9973 8 วันที่ผ่านมา

    Is it possible to receive data on Siemens Logo 8.4 from another device via MQTT? Before this I used Modbus

    • @blociot
      @blociot 8 วันที่ผ่านมา

      @@serjonik9973 LOGO can subscribe to any MQTT topic but the topic payload should be in a predefined JSON format and it's a bit tricky. I'll do some tests and will record a quick video for it.

  • @arenetasatrec4939
    @arenetasatrec4939 8 วันที่ผ่านมา

    Nice. Did you managed to send signals from homeassistant or any type of platforms in to LOGO to act as inputs to do some actions with LOGO program such a trigger outputs or programme logics? If yes, in which video?

    • @blociot
      @blociot 8 วันที่ผ่านมา

      @@arenetasatrec4939 thanks for watching. I don't have a video for it but you're not the only person who asked for this feature so I will do a quick test and will record a short video for it in coming days.

  • @Tevez2367
    @Tevez2367 13 วันที่ผ่านมา

    What happens if you have two cpus and three RIO units in project but only one RIO can be connected for commissioning does it have to be setup as in your video? Or can you complete the ring without the other two RIOs ?

    • @blociot
      @blociot 12 วันที่ผ่านมา

      Great question! If RIOs are just a node in the ring not redundant RIOs, they don't have to be connected and can be connected later. But Redundant RIO is a diffefent story. Here is a useful link: support.industry.siemens.com/cs/document/109767576/connection-of-redundant-i-o-devices-to-s7-1500?dti=0&lc=en-WW

  • @mohammedrezk8072
    @mohammedrezk8072 18 วันที่ผ่านมา

    please continue for another video to show the config of that device.

    • @blociot
      @blociot 17 วันที่ผ่านมา

      @@mohammedrezk8072 thanks for your feedback. Setting the module up is fairly easy. The module has a web page and a basic wizard to set up the SIM provider APN, type of antenna, etc. The only tricky part could be defining firewall rules if you don't want to grant complete access. I will record a tutorial once I get access to a device 🙏

  • @UniqueunlimitedBD
    @UniqueunlimitedBD 21 วันที่ผ่านมา

    The TH-cam channel video's SEO rating is poor of Due to this your subscribers and views are not increasing, and the titles, descriptions, and keywords SEO should be done correctly only then you will get good results. the same problem in Video every.

    • @blociot
      @blociot 6 วันที่ผ่านมา

      Thank you for the heads up. I just share videos to share knowledge. I'm not a professional content creator and don't know much about SEO on YT. But I should start working on it 👍

    • @UniqueunlimitedBD
      @UniqueunlimitedBD 6 วันที่ผ่านมา

      @@blociot Can I help you?

  • @UniqueunlimitedBD
    @UniqueunlimitedBD 21 วันที่ผ่านมา

    Every single video on your channel is amazing. But your video views are lower. Because your optimization is very poor. Your optimization needs to improve as soon as possible.

    • @blociot
      @blociot 20 วันที่ผ่านมา

      @@UniqueunlimitedBD thank you for your feedback.

  • @Apphugs
    @Apphugs 24 วันที่ผ่านมา

    Excellent - thank you

    • @blociot
      @blociot 24 วันที่ผ่านมา

      @@Apphugs thank you for watching

  • @rezamahmoudi163
    @rezamahmoudi163 26 วันที่ผ่านมา

    please share source code ?

    • @blociot
      @blociot 24 วันที่ผ่านมา

      Hi @@rezamahmoudi163 . This was part of a project. I'll prepare a short version and will publish as soon as I find some time.

  • @21Aera
    @21Aera 26 วันที่ผ่านมา

    Great content ! Thank you. It would be great to see also how to read a state from HA into the LOGO. For instance if a light is connected to the LOGO and we want to turn it on/off from HA.

    • @blociot
      @blociot 26 วันที่ผ่านมา

      Thank your for your feedback. Great question. To control a light switch from HA, you need to define a SWITCH instead of SENSOR on the yaml file. you can find the details here: www.home-assistant.io/integrations/switch.mqtt/ The only catch is the json payload format that needs to be defined under the SWITCH. Here is an example that you can use: { "state": { "reported": { "VM4": { "desc": "V-word-4-1", "value": [ 13 ] } } } } This payload write the value of 13 to VM4 which is defined in LOGO MQTT transfer area.

    • @21Aera
      @21Aera 24 วันที่ผ่านมา

      @@blociot Thank you! I'll try that when I have a chance to play with my lab 😁

  • @Ind4.0
    @Ind4.0 29 วันที่ผ่านมา

    Seems my sprinkler system needs an upgrade 😅 Cool feature!

    • @blociot
      @blociot 29 วันที่ผ่านมา

      @@Ind4.0 great application 👌

  • @Ind4.0
    @Ind4.0 หลายเดือนก่อน

    Cool! Looks like a robot controller!

    • @blociot
      @blociot หลายเดือนก่อน

      Exactly 👌

  • @shubhaml3646
    @shubhaml3646 หลายเดือนก่อน

    Unfotunately Just what your project is and visualize it is not usefull, but how you did it what source code you used is much important to share

  • @mohammedrezk8072
    @mohammedrezk8072 หลายเดือนก่อน

    could you please make a video for the differences between Siemens panels(comfort/unified/..etc) cause i'm confused some are simulated with wincc/runtime / some with webservers ....will be grateful

    • @blociot
      @blociot หลายเดือนก่อน

      Great idea. I will make a quick video to explain different families in one quick video.

  • @WillPark98
    @WillPark98 หลายเดือนก่อน

    Hi, I have a very similar setup. I can connect to the S615 through Sinema RC Client but it only gives me access to the IP address of the S615, not the rest of the local network with the PLC. Do you have to set up static routes on the S615 to map traffic between internal and external?

    • @blociot
      @blociot หลายเดือนก่อน

      Hi Will. Exactly. You need to allow traffic between internal ports and the external port. Also, you need to define the participants groups and Subnet (your PLC IP address range) on your server under Devices and Network setting.

    • @WillPark98
      @WillPark98 หลายเดือนก่อน

      @blociot hi, thanks for the reply. I managed to get it working. On SINEMA RC server, I selected NAT mode 1:1 for the device and entered the IP subnet and now its working. Thanks, great video

    • @blociot
      @blociot หลายเดือนก่อน

      Awesome. Thanks for watching. All the best

  • @NSAwatchesME
    @NSAwatchesME หลายเดือนก่อน

    i cant find price how much they cost

    • @blociot
      @blociot หลายเดือนก่อน

      You may try Siemens industry mall for your country on the link below: mall.industry.siemens.com/goos/WelcomePage.aspx?regionUrl=/&language=en Or contact a local sales rep un your city to get the price with any possible deals.

  • @guilhermesouza4373
    @guilhermesouza4373 หลายเดือนก่อน

    Finder OPTA is better

    • @blociot
      @blociot หลายเดือนก่อน

      Never used it. But curious what do you like about it? Seems over priced and the ladder IDE is too basic.

  • @thorstenfricke3257
    @thorstenfricke3257 หลายเดือนก่อน

    wonderful

  • @thorstenfricke3257
    @thorstenfricke3257 หลายเดือนก่อน

    i cant find the sw 8.4 anywhere in the german internet. please could send me a link?

    • @blociot
      @blociot หลายเดือนก่อน

      Hi Thorsten, You can try this link on SIOS: This is an upgrade. So you will need to have an oldef version su h ad v8.3 installed before running this upgrade support.industry.siemens.com/cs/document/109826553/download-and-installation-instructions-for-logo!-soft-comfort-upgrade-v8-4?dti=0&lc=en-US

    • @thorstenfricke3257
      @thorstenfricke3257 หลายเดือนก่อน

      @@blociotthank you! i downloaded a demo from those link you provided. but i dont know how to make a non demo version from it. i have to find out

    • @blociot
      @blociot หลายเดือนก่อน

      @@thorstenfricke3257 if you had a previous version of LOGOsoft comfort on your machine, you don't need to do anything else. The file on the link upgrades your existing software. Otherwise, you have to do a one time purchase from your local Siemens rep. It's not an expensive software

    • @thorstenfricke3257
      @thorstenfricke3257 หลายเดือนก่อน

      @@blociot thank you

    • @thorstenfricke3257
      @thorstenfricke3257 26 วันที่ผ่านมา

      @@blociot it was much easier! reichelt sold the 8.4 sw! amazing! i was surprised when it came

  • @thorstenfricke3257
    @thorstenfricke3257 หลายเดือนก่อน

    1000 thanks

  • @PM-pp3so
    @PM-pp3so หลายเดือนก่อน

    I use a VPN router to see LWE website but with Mqtt protocol can someone make an smartphone app with datas from an MQTT broker ? many thanks

    • @blociot
      @blociot หลายเดือนก่อน

      Sure you can. Facebook messenger app is a good example that mostly uses MQTT for communications.

    • @PM-pp3so
      @PM-pp3so หลายเดือนก่อน

      @@blociot Entonces si el logo envia las variables en un cloud como AWS. Un desarollador de app para movil podria crear una app ?

  • @PM-pp3so
    @PM-pp3so หลายเดือนก่อน

    I don't understand if logo can be used only with MQTT broker or comunicate in a local red. ? Can interact with homeassistance ? thanks

    • @blociot
      @blociot หลายเดือนก่อน

      Hello, LOGO can be a MQTT client. It cannot be an MQTT broker. So if you have an MQTT broker, LOGO can publish or subscribe to data on the broker. It can also be connected to Homeassistant as an MQTT sensor, etc. with JSON payload

    • @PM-pp3so
      @PM-pp3so หลายเดือนก่อน

      @@blociot Estamos hablando de una comunicación a nivel local... sin internet ? gracias.

  • @user-si6vo6vq9m
    @user-si6vo6vq9m 2 หลายเดือนก่อน

    thanks for the excellent content. Is it possible to have Python demo project?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Thank you for your feedback. Please send me a message on Linkedin. I can surely send it to you if I find it.

  • @GinoFavero94
    @GinoFavero94 2 หลายเดือนก่อน

    Hi , thanks for your very useful video. I couldn't find the Unified basic panel PDF that you are showing, I only found the comfort version. Where can I find it?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Hi Gino. I asked the local Siemens sales rep to send me. Just find a local sales rep and ask for it. You can try opening a support ticket on online support website to see if they have it.

  • @dtib1539
    @dtib1539 2 หลายเดือนก่อน

    I wish logo in new version could also manage float values😒

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Good point. There are some workarounds for some floating point applications. Have you seen the I/F and F/I functions? support.industry.siemens.com/cs/mdm/100782807?c=120748741643&dl=no&lc=fr-WW Out of curiosity, hat are you trying to do?

  • @eduardobrisolla1185
    @eduardobrisolla1185 2 หลายเดือนก่อน

    Hi friend, do u know why I can´t find my MTP400 in the TIA v17 hardware list? that folder not even exists 😢

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Hi Eduardo. If you have a MTP400 BASIC, it is only available in TIA V19. Unified basic panels are very new and introduced with TIA Portal V19.

    • @eduardobrisolla1185
      @eduardobrisolla1185 2 หลายเดือนก่อน

      @@blociot very helpful. Now I can't stablish a communication between PLC s7 1200 and my HMI MTP400. There's some detail that I'm missing?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      @@eduardobrisolla1185 there are a few factors that can cause this issue. First, make sure you have an HMI connection defined between your PLC and HMI. Then make sire the time zone is the same for both devices. Finally, make sure the CPU security allows access to all devices and the certificate is valid.

  • @user-if8sw6vp6m
    @user-if8sw6vp6m 2 หลายเดือนก่อน

    Why there is a phonk?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Selected it accidentally, but liked it after :D

  • @jr_electrical-Engg
    @jr_electrical-Engg 2 หลายเดือนก่อน

    Can we add switch in in interface port 2 of 1515R

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Sure. The CPU in this deno is connected to a Scalance switch on its right side.

    • @jr_electrical-Engg
      @jr_electrical-Engg 2 หลายเดือนก่อน

      But interface 2 haven't MRP can we connect directly

    • @blociot
      @blociot 2 หลายเดือนก่อน

      @@jr_electrical-Engg I am not sure if I fully understand your concern. You may send us a message on Linkedin to chat more with details. Overall, each CPU has two independent ports (X1 and X2). In this demo, X2 of each CPU is unused. So you may ise it for any purpose. But X2 is not a part of MRP ring so you won't get benefit of MRP ring. Overall, it's not a good idea to do it this way. If you need to add a switch, add it to the ring. Hope this helps

  • @stevenrb5168
    @stevenrb5168 2 หลายเดือนก่อน

    Hi my friend congratulations for this excelent video, I have a problem, i have the Logo 8.4, I see my ipv4 on windows and my PLC is in the same subred, but after make all the steps that you show to connect with mosquitto, doesn't connect, only I see connecting and after that show me a message "server connection error" maybe do you know what i have to do?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Thank you for your comment. Do you see the connection error? On LOGO side or on the MQTT client? You need to make sure your Mosquitto settings match what you enter in LOGO configs. If you have a username and password on the Mosquitto broker, you need to let LOGO know to connect!

  • @user-ow3eh7bv5o
    @user-ow3eh7bv5o 2 หลายเดือนก่อน

    "Hello, do you happen to have a video where AWS is used for LWE? I'm having trouble creating my cloud." :(

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Hi, Unfortunately, I don't have a video but if you could privide some details on the issue, I might be able to help. Most issues are related to IAM roles and AWS side.

  • @domenicapalacios7396
    @domenicapalacios7396 2 หลายเดือนก่อน

    Good afternoon, please help me with the SMTP settings, the name of the server and what would be the port.

    • @blociot
      @blociot 2 หลายเดือนก่อน

      Hi, The SMTP setting depends on the email address you are using. Just search for the SMTP setting on your email provider website.

  • @elkechebourabir5241
    @elkechebourabir5241 3 หลายเดือนก่อน

    Please sir , i followed the same steps as you but when i enable the block. An 16#8061 error appears i tried so hard but i can't fix please help me

    • @blociot
      @blociot 2 หลายเดือนก่อน

      8061 is most likely because your PLC cannot find the MQTT broker. Are you using a local MQTT broker or a cloud version? You need to make sure DNS is set up correctly if not using the IP address for the broker. Also, make sure you can ping both PLC and broker on the same network.

  • @TheAslanmemo
    @TheAslanmemo 3 หลายเดือนก่อน

    im wating part 2 please

    • @blociot
      @blociot 3 หลายเดือนก่อน

      A bit busy with work trips. Recording part 2 is in progress. Stay tuned 🙏

  • @fh1772
    @fh1772 3 หลายเดือนก่อน

    Is it possible to call urls / webhooks from the LOGO?

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Unfortunately, not yet. But there might be an unofficial way. For now, MQTT and email seems to be the best way to work with events. For sure middleware can be used too.

  • @MrDawen1997
    @MrDawen1997 3 หลายเดือนก่อน

    wow did you paid for both the cpu's yourself? quite expansive!

    • @blociot
      @blociot 3 หลายเดือนก่อน

      The demo was borrowed from local Siemens office :)

    • @MrDawen1997
      @MrDawen1997 3 หลายเดือนก่อน

      @blociot thanks for the reply. Didn't that was possible. Do you rent that or need to be a siemens certified partner?

    • @blociot
      @blociot 3 หลายเดือนก่อน

      @@MrDawen1997 anyone who want to buy a unit, they can ask for a demo for testing as long as the local office has a demo available. You should call them and ask.

  • @habibbparva7642
    @habibbparva7642 3 หลายเดือนก่อน

    Can i ask you a question about my Winncc unified pc rt?

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Sure

    • @achrafoulidi6548
      @achrafoulidi6548 2 หลายเดือนก่อน

      @@blociot hello , i have a tia-portal v18 but i didint found hmi simatic unified confort panel . how can i do to get it plz?

    • @blociot
      @blociot 2 หลายเดือนก่อน

      @@achrafoulidi6548 you have to install it. It's on the same DVD as Step 7. If you haven't install it, just run the installation again and select modify and install WinCC Unified.

  • @mohammedrezk8072
    @mohammedrezk8072 3 หลายเดือนก่อน

    many thanks for this useful content

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Glad it was useful. Stay tuned for the next video in the coming days.

  • @michakurek5618
    @michakurek5618 3 หลายเดือนก่อน

    Hi, I have a problem with mosquitto docker build it says that: => ERROR [mosquitto 3/7] RUN apk update && apk add --no-cache rsync tzdata 12.3s ------ > [mosquitto 3/7] RUN apk update && apk add --no-cache rsync tzdata: 0.547 fetch dl-cdn.alpinelinux.org/alpine/v3.18/main/aarch64/APKINDEX.tar.gz 5.544 WARNING: updating and opening dl-cdn.alpinelinux.org/alpine/v3.18/main: temporary error (try again later) 5.544 fetch dl-cdn.alpinelinux.org/alpine/v3.18/community/aarch64/APKINDEX.tar.gz 10.55 WARNING: updating and opening dl-cdn.alpinelinux.org/alpine/v3.18/community: temporary error (try again later) 10.55 4 unavailable, 0 stale; 21 distinct packages available ------ failed to solve: process "/bin/sh -c apk update && apk add --no-cache rsync tzdata" did not complete successfully: exit code: 4 What can i do?

  • @habibbparva7642
    @habibbparva7642 3 หลายเดือนก่อน

    good work

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Thank you for watching

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    how many analog inputs can they model take

    • @blociot
      @blociot 3 หลายเดือนก่อน

      I'll ahow on datasheet when we discuss the analog processing.

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    and how to read 0V to 5V sensors analog input usually made for Arduino

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Sure. We will have a drdicated video for analog signal manipulation.

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    Great Video please also consider a PWM in LOGO! current no English video on this topic

  • @gussinger6939
    @gussinger6939 3 หลายเดือนก่อน

    can I also use this method in order to send SCL Code to the CPU and run it? Let´s say I write SCL Code in an external editor and then want to test it on a real device. Is that possible?

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Short answer is not directly. But TIA Portal has a feature called Openness which let you do many tasks by scripting. It might be helpful to look at. You can send your data (an SCL code in your case) to the PLC, but therr should be another interface to receive the data and save it as a FB, FC, etc.

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    Can you please draw the wire connections in AutoCAD Electrical so that we can gain experience working with it?

    • @blociot
      @blociot 3 หลายเดือนก่อน

      I don't have access to ACad at the moment, but that's a good idea. We will post a video about CAD, P&ID, etc

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    and please add virtual hmi's on website, phone and pc and database online with logo! live data

    • @blociot
      @blociot 3 หลายเดือนก่อน

      We will have a tutorial for HMI soon.

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    i'll be using a project using logo!

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Great to hear that. Next tutorial is coming soon.

    • @plant_paradox5663
      @plant_paradox5663 3 หลายเดือนก่อน

      @@blociot really appreciate your efforts

  • @plant_paradox5663
    @plant_paradox5663 3 หลายเดือนก่อน

    will you be using logo!8.4

  • @MrArasbah
    @MrArasbah 3 หลายเดือนก่อน

    Awesome! Thank you so much for the video .. we are waiting for the other videos ... ❤❤❤❤ well done.

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Thank you for the feedback 🙏

  • @dominicdupont3917
    @dominicdupont3917 3 หลายเดือนก่อน

    This video rocks! Great job!

    • @blociot
      @blociot 3 หลายเดือนก่อน

      Thank you for watching 🙏