- 100
- 733 926
Dnoorian
Canada
เข้าร่วมเมื่อ 18 มี.ค. 2012
Danny Noorian is a red seal refrigeration mechanic and also the owner of Below 4 Refrigeration Ltd. Ever since he was 8 years old he always had a passion for commercial refrigeration and entrepreneurship. His passion for refrigeration most likely came from past generations because his dad and grandpa were also in the refrigeration industry. Danny received his red seal certificate in 2016 and started Below 4 Refrigeration Ltd the same year. Below 4 Refrigeration Ltd. is now becoming one of the fastest growing refrigeration companies in British Columbia.
OFFLINE MARKETING FOR HVACR
Making offline marketing popular again. In this video I focus on offline marketing strategies for any HVACR company. I personally use all of these strategies in my company and I'm certain it will work for you too.
มุมมอง: 261
วีดีโอ
10 things NOT to do when on a service call
มุมมอง 2464 ปีที่แล้ว
If you like your job, don't do any of the things I mention in this video ;)
TOP 10 HVACR TECHS YOU SHOULD FOLLOW
มุมมอง 4284 ปีที่แล้ว
Here is the 10 top list of hvacr techs you should follow. . . . . . . . . . . . . . . . . 1) 945hvacoutlaw: 945hvacoutlaw?hl=en 2) Hvacreferguy: hvac_refer_guy?hl=en 3) Hvacknowitall: hvacknowitall?hl=en 4) Rookierefrigeration: hvacknowitall?hl=en 5) Fridgeguru2: fridgeguru2?hl=en 6) Hvacrefertech: hvac_ref...
HOW TO INSTALL A REVERSING VALVE FOR A HEAT PUMP
มุมมอง 15K4 ปีที่แล้ว
After watching this video you will know how to install a reversing valve for a heat pump.
SINGLE PHASE COMPRESSOR WIRING
มุมมอง 22K4 ปีที่แล้ว
Long story short, customer bought 3 outdoor condensing units that use 3phase power and after buying them he realized that he only has single phase power. Called me in to replace the 3 3 phase compressors with 1 phase compressors. In this video, I do all the electrical wiring from start to finish so you guys can take a look at what it looks like. One thing to remember is that 3 phase compressors...
PRODUCT REVIEW #1: EasySeal UV DYE
มุมมอง 38K4 ปีที่แล้ว
Been working on this leaky refrigeration system for about 9 months now and I've had a tough time finding the leak. How this system was set up was that there was one condensing unit for 2 evaporators (one walk in cooler and one under counter cooler) If you guys know me, you guys know that I try to stay away from UV dye's as much as I can; However, I decided to give the EasySeal UV dye a shot bec...
How to build a shroud for your for condensing unit
มุมมอง 1.3K4 ปีที่แล้ว
A fan shroud is a thin cover that envelopes the condenser coil. The purpose of the shroud is to provide more air flow through the condenser causing the condenser coil to stay cool. How it works is that by covering the condenser coil with a shroud there is now a more confined area in which the condenser fan can pull from. Of course, this only works if shroud is correctly placed and is fitted tig...
BROKEN BIN SWITCH ON MANITOWOC ICE MACHINE
มุมมอง 19K4 ปีที่แล้ว
Ice machines can be very difficult to troubleshoot. They involve many electrical parts and can be very tricky to fix. There are all sorts of brands that use all sorts of parts and electronics. All thought most manufacturers have tech support, they rarely pick up your call in a timely manner and when they finally get back to you, you are rarely still at the job site. The more you work on commerc...
WALK IN COOLER DOOR LOCK FIXED
มุมมอง 6K4 ปีที่แล้ว
Some walk in boxes carry some very valuable products that the owner might want to lock the door. Obviously the whole point of the locking your walk in door is to reduce stolen goods. Having the improper set up for your lock can lead to the door not being locked properly and still being able to be opened with the lock still on it... trust me, I've seen this one too many times. Although the door ...
Refrigeration Dye: Worth the Fix?
มุมมอง 2214 ปีที่แล้ว
A lot of refrigeration and hvac technicians love it and some hate it. I personally think that refrigeration dye is for lazy techs who don't want to spend the time to try and find the leak using basic techniques. Refrigeration dye is typically used to find hard-to-find leaks in which no other technique can be as efficient and as quick. After the using the dye, if the tech finds the leak they wil...
HOW TO PROGRAM YOUR MIDI4V TEMPERATURE CONTROL
มุมมอง 894 ปีที่แล้ว
So this temperature control is not as common as a dixell or a danfoss but there are some midi4v temperature controls out there. In this particular case, this one was on a Italian gelato case in which I forgot the brand name of. However I struggled to find any literature on this temperature control online so I figured It would be a good idea to make a short video on how to set the temperature on...
INSIDE A SHORTED ROTARY COMPRESSOR
มุมมอง 3965 ปีที่แล้ว
Here we a doing an autopsy on a rotary compressor I took out of a 3 ton trane heat pump.
FOR ALL YOU TEMPERATURE MONITORING COMPANIES: GLYCOL SENSOR PLACEMENT
มุมมอง 3055 ปีที่แล้ว
More and more restaurants are using temperature monitoring companies to ensure that the temperatures inside their cooling system are normal. There are many temperature marketing companies out their so it is important that you pick a good one.... one that knows exactly what they are doing, have some background in refrigeration and have the experience to get the job done. The MOST IMPORTANT thing...
CALIBRATING SENSOR ON CAREL TEMPERATURE CONTROLLER
มุมมอง 19K5 ปีที่แล้ว
So you just bought a new no name cooler and plugged it in at your restaurant. You let it run for about an hour or 2 and realize that the temperature inside is running above 4 degrees Celsius. I can easily say that the NUMBER 1 reason why this happens is because the sensor is not calibrated. Meaning that the sensor is not reading the same temperature inside the box. With a few steps this can eas...
WELCOME TO MY YOUTUBE CHANNEL
มุมมอง 5205 ปีที่แล้ว
What up guys. Its your boy Danny Noorian (dnoorian) and I just want to take the time and welcome you guys to my channel. Feel free to surf my channel as for there is lots of useful knowledge that can be learned and shared. If you have any questions regarding any of my videos feel free to drop me a line and I will try to get back to you the same day.
HOW TO FIX GAPS ON YOUR SLIDING DOOR COOLER
มุมมอง 9K5 ปีที่แล้ว
HOW TO FIX GAPS ON YOUR SLIDING DOOR COOLER
Why compressor cushions should always be used.
มุมมอง 965 ปีที่แล้ว
Why compressor cushions should always be used.
LOW REFRIGERANT CHECK USING LOW PRESSURE SWITCH
มุมมอง 6175 ปีที่แล้ว
LOW REFRIGERANT CHECK USING LOW PRESSURE SWITCH
Eric Kauko (owner of Arms Reach Bistro and Ingrain) testimonial for Below 4 Refrigeration
มุมมอง 2785 ปีที่แล้ว
Eric Kauko (owner of Arms Reach Bistro and Ingrain) testimonial for Below 4 Refrigeration
Boy With A Knife (co-owner Brandon) testimonial for Below 4 Refrigeration
มุมมอง 895 ปีที่แล้ว
Boy With A Knife (co-owner Brandon) testimonial for Below 4 Refrigeration
Nat's pizza testimonial for Below 4 Refrigeration
มุมมอง 2165 ปีที่แล้ว
Nat's pizza testimonial for Below 4 Refrigeration
David Dupree testimonial for Below 4 Refrigeration
มุมมอง 935 ปีที่แล้ว
David Dupree testimonial for Below 4 Refrigeration
Hassan (owner of Bliss Cafe) gives a testimonial for Below 4 Refrigeration.
มุมมอง 1195 ปีที่แล้ว
Hassan (owner of Bliss Cafe) gives a testimonial for Below 4 Refrigeration.
Owner of Common Ground Farm (Dave) gives a testimonial for Below 4 Refrigeration.
มุมมอง 555 ปีที่แล้ว
Owner of Common Ground Farm (Dave) gives a testimonial for Below 4 Refrigeration.
Mike gives a testimonial for Below 4 Refrigeration.
มุมมอง 1505 ปีที่แล้ว
Mike gives a testimonial for Below 4 Refrigeration.
TROUBLESHOOTING DEFROST TIMER (WITH TOOLS)
มุมมอง 1.6K5 ปีที่แล้ว
TROUBLESHOOTING DEFROST TIMER (WITH TOOLS)
TROUBLESHOOTING DEFROST TIMERS WITHOUT TOOLS
มุมมอง 1.7K5 ปีที่แล้ว
TROUBLESHOOTING DEFROST TIMERS WITHOUT TOOLS
QUICKEST WAY TO FIND OUT WHICH UNIT BELONGS TO WHAT
มุมมอง 1265 ปีที่แล้ว
QUICKEST WAY TO FIND OUT WHICH UNIT BELONGS TO WHAT
J'ai plusieurs marque de régulateur celui avec le moins de sav et carel dixell en supervision et loin graphiquement et fiabilité par rapport a carel danfoss etc. Votre pays secteur ne travail peut avec carel comme dans mon secteur dixell et au millieu entre ako carel danfoss eliwell dixell etc Dixell la plupart des composants et fabrication réalisée en chine carel pour du oem chine car chez mes fournisseurs parfoit écrit dautre pays pour moi toutes les marques sont au même niveau qualité développement logiciel carel et danfoss de mon points de vue on une avance Johnsoncontrol moi j'aime pas car la logique de paramétrage et déroutant pour moi pourtant ils sont fiable chaque technicien a des préférences 1 câblage 2 paramétrage 3 visuel 4 fournisseurs (produit de qualité mais personne na de disponible tu installe autre chose). Ayant dans mon parc beaucoup de marque les services téléphoniques carel en france et ultra ractif dixell faut prendre rendez-vous par mail😂 voila un point de vue d'un autre frigoriste d'un autre pays.
How did you even remove the evap/condenser from the pop cooler?
A you forgot to. Put another of water hose
Great presentation. Like others have mentioned, in the classic legislation environment, where you are just pulling water from the tap to cool the condenser, yes - these are generally not eco friendly. However IMO, if you have a lake, a geothermal system, a small chiller, or the equivalent, you are much better off with the water cooled system.
Thanks for sharing
The only explanation on youtube that is real and helpful.
Really!!! Spraying that crap in a fruit freezer???, Is this guy a IDIOT, or just from some Country that doesn't know better? What a IDIOT!
Thank you for your information
is it possible to reuse the hot water coming out for other purposes like toilet flush/washing machine?
Tell the truth you let the freon out into the air 😂
what about 6 ?
can I have one of those chemically soaked oranges please? good lord
very cool concept of water cooled ACs
hope you weren't the installer?
Didn't get c1, only thing that showed up was rd, HELP
Yeah the video failed to mention each manufacturer sets the controler differently. Press and hold longer and enter access code 22. Then find C1 . Hope this is helpful. You can also find the chart symbols online easily .
@@orfatron thank you
Nice work
I would remove the entire EVAP coils and take outside to clean.. then completely let it sun dry.. Same with the fans... remove , take outside to clean.
Mistakes friend,first defrost the evaporator,the valve allready is working low superheated and liquid is flooding in compresor.You "fixed it the opposite way",you destroyed it...haha
Ty
Stop using trash
How did you miss that pinched off liquid line at the bottom flare nut on the Txv valve?
I have a true drink cooler it was freezing the drinks no matter the setting it was on I replaced with a new thermostat off eBay and it will not cool below 50 degrees 831932 part number idk if you have any idea thank you
Depends on the model of the true cooler you have. Each true equipment has a different type of thermostat. Call true mfg and they will give you the correct part number, then you can buy off www.partstown.com
Will there be a video showing how freon is pumped into the receiver when the filter on the refrigerator is changed? Greeting
Where is your BEARD NET? That's a GMP VIOLATION.
You are using more refrigerant to cool the water in an exterior motion, and a pump which uses electricity to pump the water that the condenser is submerged in to merely achieve greater results all legal
All you must do is put the coil submerged in water, circulate the water with the pump to a reservoir of cold or water, using the same principle of AC to cool the condensing unit in no time the transfer of heat will be much greater
I have a 115 volt walk in cooler. The compressor has a start and run capacitor. Would a 3n1 work on this application?
DO NOT follow this guys steps, he did it the incorrect way. 🤦🏻♂️
Great information, thanks 👌
Where do you get your stickers made and what software do you use to stay organized?
you idiot the cam was on fire 😂😂😂😂
Could not see any work being done
Hello partner on duty! A got some kind of troubleshooting this type of problems... This time was a low ppressure in liquid line just afte filter drier (160psi) and quite good pressure in low side after evap n Comp rotalock (18-20psi) for a 404a walking in freezer meat storage. Txv and beyond still froozen. Sight glass is clear most the time then just flush ... I know is full, Maybe refull of refrigerante the entire system. Good both sides vents, cond-evap were washed. Help me, dont wanna loose this client😢
There's no label about Oz or Kg to charge the Unit :/
But this is absolute rubbish for repairing household refrigerators. I have been professionally repairing household appliances for more than 20 years. I have tried various seals from time to time. None of them give a significant result.
Why you have to adjust the txv if it was working properly before?looking at your suction pressure and considering that the evap coil have some ice i assume you have overcharged the system.Also you dont measure superheat without cleaning the ice of the evap coil first
I have one similar. I plug it in and does not come on. The only noise is from the Omron GL7, the only clicks as i plug the unit. PLEASE HELP..
Hookup the water to closed loop geothermal.
is call omega clip 2 plastic spacer, square washer then the bracket and finish with the star washer and the final screw
Thank you for your video, got one of these and trying to figure out how to fix the gaps.
Terrible video...not worth watching!!
How do you clear a cl alarm ?
Just barefaced it huh bruh
it would have been a great video if you show the controller rather than your face , we could not see what you were doing
You should always check power hot to natural instead of ground. It possible you lost your ground
Good job, pls can have your WhatsApp number
Is the door heater connected with the compressor… is it ON all the time or only works during defrost?
Man, seems like you need some professional help.
what happens when the door lock opens . is ther e a spring in the door latch ?
How do you get that unit off the refrigerator?
I love it when someone is doing a repair, for the first time, and makes an, "expert" video. Some people love them some them.
....and if that doesn't help....?!? Bridge was near ½" on Default-setting. Moving it to the right, decreased it to about ¼"....but still too thick......
These videos are sweet please continue
Thanks. You can find more of these videos on my Instagram @dnoorian