Axion Labs & Training Institute
Axion Labs & Training Institute
  • 87
  • 260 840
HPLC: Analyzing a New Sample - Step By Step
Get the links for each part of the series here: axionlabs.com/chromatography-training/hplc-basics-video-analyzing-a-new-sample/
Learning the basics of HPLC and some principle of analytical chemistry will help you confidently analyze your own samples from scratch.
In this labinar series we show you - step-by-step - how to think about analyzing an unknown sample with HPLC for the first time. We will walk you through sample prep considerations, method development and optimization, and building a calibration curve.
Plus 2 bonus videos: Building a method in ChemStation and HPLC method optimization.
🔗 Follow Us:
Website: axionlabs.com/
Facebook: axionlabs
LinkedIn: www.linkedin.com/company/axion-labs/
#analyticalchemistry #hplc #Chromatography #LabTechniques #ScientificResearch #Chemistry #labtips
Axion offers hands-on HPLC (High-performance liquid chromatography or high-pressure liquid chromatography) and GC (gas chromatography) training courses. Gain advanced HPLC & GC skills with our 5 day hands-on LC/GC bootcamp. If you can't make it to Chicago choose one of our online courses. After taking the LC/GC bootcamp further advance your skills by taking the advanced topics courses.
มุมมอง: 186

วีดีโอ

How does mass spec work?
มุมมอง 4568 หลายเดือนก่อน
Watch the full webinar on Axion Lite - Free HPLC and GC training. courses.axionlabs.com/course/axion-lite?previouspage=allcourses&isenrolled=no#/sales?ticketId=3283437000000185030 Subscribe for more insights into chromatography techniques and applications. 🔗 Follow Us: Website: axionlabs.com/ Facebook: axionlabs LinkedIn: www.linkedin.com/company/axion-labs/ #analyticalchemistry #h...
What's unique about Axion courses?
มุมมอง 6059 หลายเดือนก่อน
See what an Axion course is like. Subscribe for more insights into chromatography techniques and applications. 🔗 Follow Us: Website: axionlabs.com/ Facebook: axionlabs LinkedIn: www.linkedin.com/company/axion-labs/ #analyticalchemistry #hplc #Chromatography #LabTechniques #ScientificResearch #Chemistry #labtips Axion offers hands-on HPLC (High-performance liquid chromatography or h...
Everything you need to know about HPLC flow rates
มุมมอง 1.1K9 หลายเดือนก่อน
HPLC flow rates very depending on the column diameter. In this video we talk about columns ranging from 2.1 to 50 millimeter ID. Read the full post here: axionlabs.com/chromatography-training/hplc-flow-rates-everything-you-need-to-know/ Subscribe for more insights into chromatography techniques and applications. 🔗 Follow Us: Website: axionlabs.com/ Facebook: axionlabs LinkedIn: www...
When to use a gradient in HPLC?
มุมมอง 1.8K9 หลายเดือนก่อน
How do you know when you should use an gradient elution instead of isocratic elution? In this exploration of gradients in chromatography, we unpack the pivotal question: when is a gradient necessary? The heart of the matter lies in the hydrophobic similarities of the molecules being analyzed. If they share similar hydrophobicities, a gradient might not be needed, as indicated by a scouting run ...
Dwell Volume vs Dead Volume
มุมมอง 93710 หลายเดือนก่อน
Let me make a couple of clarifications here. Instead of using the term “dead volume,” we prefer the term “extra column volume.” Extra column volume indicates the volume outside of the column, which we aim to minimize. Minimizing extra column volume is crucial for all our LCs, as it affects our efficiency and the skinniness of our peaks. Read the blog article here axionlabs.com/chromatography-tr...
Monomeric vs Polymeric C18 Columns
มุมมอง 35910 หลายเดือนก่อน
In this video, we dive into the world of chromatography to understand the difference between monomeric and polymeric C18 columns. We break down the technical jargon to explain how these columns work and their significance in chromatographic separations. From the basics to practical applications, join us as we unravel the mysteries behind these essential tools in the lab. Read the blog here axio...
Can I run an HPLC gradient from 0 to 100%?
มุมมอง 54810 หลายเดือนก่อน
For related videos watch: Can you run 100% water with a C18 column? th-cam.com/video/xwMYDUYPJR0/w-d-xo.html HPLC Problems: Very polar molecules. th-cam.com/video/HZV5B_p6OeM/w-d-xo.html Read the blog post here axionlabs.com/chromatography-training/can-i-run-an-hplc-gradient-from-0-to-100/ Subscribe for more insights into chromatography techniques and applications. 🔗 Follow Us: Website: axionla...
What is void volume, void time, t0 and solvent front?
มุมมอง 1.1K10 หลายเดือนก่อน
🔗 Follow Us: Website: axionlabs.com/ Facebook: axionlabs LinkedIn: www.linkedin.com/company/axion-labs/ #analyticalchemistry #hplc #Chromatography #LabTechniques #ScientificResearch #Chemistry #labtips Axion offers hands-on HPLC (High-performance liquid chromatography or high-pressure liquid chromatography) and GC (gas chromatography) training courses. Gain advanced HPLC & GC skill...
HPLC Tips: How to calculate void volume
มุมมอง 2.1K11 หลายเดือนก่อน
In this video we delve into the critical aspect of calculating void volume in High Performance Liquid Chromatography (HPLC). Understanding the void volume, or the space within the column not occupied by the stationary phase, is essential for precise chromatographic analysis. We start by introducing T0 measurement-how to determine the time at which solutes pass through the column without interac...
Can you run 100% water with a C18 column?
มุมมอง 90411 หลายเดือนก่อน
🔬 Mastering Your C18 Column: Essential Tips for Chromatographers 🔬 👉 What's Inside: The Water Dilemma: Can you run your C18 column with 100% water? We unravel this common question and explain why it's not recommended. Discover the impact of water on the hydrophobic nature of C18 and how it leads to phase collapse, reducing chromatography efficiency. Recovery Tactics: Accidentally used too much ...
HPLC problems with very polar molecules.
มุมมอง 579ปีที่แล้ว
🔬 Welcome to the world of HPLC columns, specifically focusing on the 'Polar Embedded Phase' technology! 🔍 In this video, we unravel the intricacies of these highly efficient columns. Read the blog here: axionlabs.com/chromatography-training/hplc-problems-with-very-polar-molecules/ 📌 Don't forget to like, subscribe, and hit the bell icon for notifications on our upcoming videos! Share your thoug...
Do I need to use an HPLC Guard Column?
มุมมอง 910ปีที่แล้ว
In this video we focus on the use of guard columns. We answer these questions: What's the deal with the guard column? Do I need one? Is it required? What's it for? 🔬 What You'll Learn: The fundamental purpose of a guard column in chromatography. How to decide if a guard column is necessary for your specific application. Tips for maintaining your analytical column and extending its lifespan. Rea...
Best solvent to dissolve HPLC samples
มุมมอง 1.1Kปีที่แล้ว
🔬 Welcome to our latest educational video on chromatography! In this comprehensive guide, we delve into the critical aspect of selecting the perfect sample solvent for effective chromatography. Whether you're a seasoned chemist or a student just starting out, this video offers valuable insights for everyone. 🌟 What's Inside: Impact of Sample Solvent on Chromatography: We start by exploring how ...
How to test a LC column?
มุมมอง 640ปีที่แล้ว
How to test a LC column?
How to clean a C18 column?
มุมมอง 5Kปีที่แล้ว
How to clean a C18 column?
What's the difference between HPLC & UPLC?
มุมมอง 3.4Kปีที่แล้ว
What's the difference between HPLC & UPLC?
HPLC Tubing & Fittings
มุมมอง 2Kปีที่แล้ว
HPLC Tubing & Fittings
HPLC Sample Prep Basics
มุมมอง 4.3Kปีที่แล้ว
HPLC Sample Prep Basics
Ghost Peaks in HPLC - 5 common sources
มุมมอง 2.8Kปีที่แล้ว
Ghost Peaks in HPLC - 5 common sources
How long does it take for a column to equilibrate?
มุมมอง 1.5Kปีที่แล้ว
How long does it take for a column to equilibrate?
Problems caused by dwell volume
มุมมอง 1.1Kปีที่แล้ว
Problems caused by dwell volume
What is dwell volume?
มุมมอง 2.6Kปีที่แล้ว
What is dwell volume?
Dr. Polite's Teaching Style
มุมมอง 207ปีที่แล้ว
Dr. Polite's Teaching Style
HPLC - Negative Peaks and Baseline Drift
มุมมอง 6Kปีที่แล้ว
HPLC - Negative Peaks and Baseline Drift
Meet Dr Polite
มุมมอง 264ปีที่แล้ว
Meet Dr Polite
It doesn't matter which brand GC or HPLC you use.
มุมมอง 5902 ปีที่แล้ว
It doesn't matter which brand GC or HPLC you use.
Hone Your Chromatography Skills at Our Chromatography Happy Place
มุมมอง 2862 ปีที่แล้ว
Hone Your Chromatography Skills at Our Chromatography Happy Place
Tour of Axion Labs
มุมมอง 3502 ปีที่แล้ว
Tour of Axion Labs
HPLC Troubleshooting: What is causing baseline noise?
มุมมอง 15K2 ปีที่แล้ว
HPLC Troubleshooting: What is causing baseline noise?

ความคิดเห็น

  • @faheem_127
    @faheem_127 วันที่ผ่านมา

    wonderful

  • @g0801215
    @g0801215 13 วันที่ผ่านมา

    I saw the technician in our institute use a syringe to draw out the liquid by unscrewing the screw on the pump.

  • @UAa320
    @UAa320 2 หลายเดือนก่อน

    I am having an issue running Benzoic acid on a Phenomenex Luna C18 column, the peak for the benzoic acid starts eluting fine but then has a really bad tail towards the end affecting my USP tailing, what I don't understand is that my salicylic acid peak is coming out fine as I have both of those components in the same standard solution what can be causing this tailing? I reverse-flushed the column thinking the column was dirty but it didn't help.

  • @smmcknnn
    @smmcknnn 2 หลายเดือนก่อน

    Very helpful, is there a way to program a sequence to do all of this automatically and generate a complete report?

  • @arisalin1874
    @arisalin1874 3 หลายเดือนก่อน

    I was feeling hopeless until I found this . I sincerely appreciate you for making this to save our motication!! Thank you very much!!

  • @ElsieCatherine-r3j
    @ElsieCatherine-r3j 3 หลายเดือนก่อน

    Gerlach Course

  • @ByronAngela-u7x
    @ByronAngela-u7x 3 หลายเดือนก่อน

    Herbert Turnpike

  • @nikkipinki860
    @nikkipinki860 3 หลายเดือนก่อน

    Thank for your video. I have problem with my HPLC agilent. Sometimes it can't turn on the light automatically. I turn on the light from the control panel manually. How can repair it to be automatically. My next question is that after 5-6 samples hplc doesn't give right concentration. For example i inject the same vial two times. First time it gives a lot of chroma grams . Second time give the right concentration. What is the problem. I think its problem of the dedector

  • @MichaelJenkins-d4d
    @MichaelJenkins-d4d 3 หลายเดือนก่อน

    Ava Turnpike

  • @ryd3775
    @ryd3775 3 หลายเดือนก่อน

    I am thinking about to investi in a businness in which I would need to use this kind of system, my quesiton is if you provide protocols and training to use. I have biochemistry background but have no clue how to operate it and I would to like to identify minerals, vitamines and etc. Simple stuff I think.

  • @platonist21
    @platonist21 3 หลายเดือนก่อน

    I like this guy

  • @JenningsHedy-m1g
    @JenningsHedy-m1g 4 หลายเดือนก่อน

    Koelpin Ports

  • @BurneJonesCora-h9g
    @BurneJonesCora-h9g 4 หลายเดือนก่อน

    Carson Glen

  • @RalphRoberta-t7r
    @RalphRoberta-t7r 4 หลายเดือนก่อน

    Kyler Valleys

  • @imadkheldoun6379
    @imadkheldoun6379 4 หลายเดือนก่อน

    Amazing explanation thank you sir

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      You are welcome

  • @elit_andrew
    @elit_andrew 5 หลายเดือนก่อน

    How do I remove the bubbles in Agilent Infinity II 1260 series

  • @kalrbaum.
    @kalrbaum. 5 หลายเดือนก่อน

    Exactly what i was looking for, thanks!

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      Glad I could help!

  • @BlahBlah-gb6st
    @BlahBlah-gb6st 6 หลายเดือนก่อน

    What could be wrong if my inlet total flow falls when the oven temp is ramping up? I have changed the septum.

  • @srirampmna135
    @srirampmna135 6 หลายเดือนก่อน

    Sir how to calculate the delay time from detector to fraction collection tube .Could u pls share ur ideas ?

  • @LaLa-qf1qz
    @LaLa-qf1qz 6 หลายเดือนก่อน

    You are a great speaker. Very confident and helpful, thank you

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      Wow, thank you!

  • @gooddaniel8603
    @gooddaniel8603 6 หลายเดือนก่อน

    How do I apply to this class ?

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      Go to axionlabs.com/lc-gc-bootcamp/. This is the hands-on class. We also offer on-demand courses.

  • @Ccccccccccsssssssssss
    @Ccccccccccsssssssssss 7 หลายเดือนก่อน

    Thanks for the great video!

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      My pleasure!

  • @lucasclementinomourao5677
    @lucasclementinomourao5677 7 หลายเดือนก่อน

    I'm currently working on a method where a pair of hydrophilic peaks elutes in less than 5 minutes, while another pair elutes about 15 minutes later in isocratic mode. When I use gradient methods (~50 to 70% ACN), the baseline drift increases significantly. What is the best way to run a gradient in these methods? Should I implement a steep gradient change in less than a minute or use a smoother gradient (over a longer period) ?

  • @srirampmna135
    @srirampmna135 7 หลายเดือนก่อน

    Sir, how does the molecule come.down when we place positive charge repeller .

  • @srirampmna135
    @srirampmna135 7 หลายเดือนก่อน

    Sir, could u pls explain about mass tuning in one video.

  • @bsadeghi1098
    @bsadeghi1098 7 หลายเดือนก่อน

    Thats very great,thanks for these useful points,could you please explain the thermostat and autosampler parts too?how can i understand the effeciency of these two parts

  • @mohamedislambenghaname133
    @mohamedislambenghaname133 8 หลายเดือนก่อน

    Is there any good method for erythropoietin in albumin serum ?

  • @denniswhv7546
    @denniswhv7546 8 หลายเดือนก่อน

    wow thanks!

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      Welcome!

  • @Will_be_back_by_2024
    @Will_be_back_by_2024 8 หลายเดือนก่อน

    I like you! You're very practical

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      I appreciate that!

  • @tayyabaraja433
    @tayyabaraja433 8 หลายเดือนก่อน

    Sir can u please tell me... Which type of standards used for the Hplc of The sample of TSB broth inoculated with bacterial strains for growth with crude oil?

  • @Sarahishamvasileva
    @Sarahishamvasileva 8 หลายเดือนก่อน

    How i can learn abt calibration, is it available for gcms

  • @wahmfarad2719
    @wahmfarad2719 8 หลายเดือนก่อน

    Dear sir you explained well..

    • @axionlabs
      @axionlabs 4 หลายเดือนก่อน

      Thank you

  • @137bob3d
    @137bob3d 9 หลายเดือนก่อน

    this Axion guy gets my vote for having fab' knowledge at the tip of his tongue

  • @dewittk9404
    @dewittk9404 9 หลายเดือนก่อน

    I’ve read that acetonitrile can have amine impurities and form deposits in pump components over time. Is there a procedure for flushing the system to remove/prevent this?

  • @ZhengZhao-j4f
    @ZhengZhao-j4f 10 หลายเดือนก่อน

    Great content! Thank u so much for sharing this!!

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      My pleasure!

  • @Phasianidaes
    @Phasianidaes 10 หลายเดือนก่อน

    Great explanation! This is critical when transferring methods into a lab with different brand and models

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      Yes, exactly

  • @heboottoobigforhegotdamnfeet
    @heboottoobigforhegotdamnfeet 10 หลายเดือนก่อน

    How to deal with negative peaks on refractive index?

  • @MOHDSALEEM-gh7tf
    @MOHDSALEEM-gh7tf 10 หลายเดือนก่อน

    Thank you sir for clearing my doubts 😊

  • @leewilliam3417
    @leewilliam3417 10 หลายเดือนก่อน

    Thanks so much 😊

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      You're welcome 😊

  • @marcoromo9252
    @marcoromo9252 10 หลายเดือนก่อน

    how does it work if using an internal standard and using their ratios?

  • @shreem3859
    @shreem3859 10 หลายเดือนก่อน

    Very pocket friendly PI... fellows from this lab will be very lucky

  • @sajidhussain-b6j
    @sajidhussain-b6j 10 หลายเดือนก่อน

    HI Lee indeed inspiring,

    • @axionlabs
      @axionlabs 8 หลายเดือนก่อน

      Glad you think so!

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    Iam facing issue in gcms as it shows vial out of range.hiw can I fix it

  • @ErikaJohnsson-y8f
    @ErikaJohnsson-y8f 11 หลายเดือนก่อน

    What HPLC machine is good enough to check Thc potency?

    • @MrSpicabooo
      @MrSpicabooo 5 หลายเดือนก่อน

      The best right now are waters arcs hplc amd waters acuity uplc

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    Can u pls explain how to setup peak purity and threshold in spectra option in agilent

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    I wish I could work under u and learn .Ur videos r really informative and interesting

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    Couod u please explain how to set the peak purity and threshold in agilent

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    I wish I could work under u and learn

  • @yerielhiciano7635
    @yerielhiciano7635 11 หลายเดือนก่อน

    What about highly acidic or basic samples? Will that affect the C18 ligands of a column. I work with human serum and plasma that are treated with acid, precipitated and the supernate is injected so not the same as the mobile phase.

  • @srirampmna135
    @srirampmna135 11 หลายเดือนก่อน

    Could u pls explain how to setup peak purity setup in spectra option in agilent