External Timecode on Sony FX9 - using Lockit Timecode by Ambient

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ก.ย. 2024
  • How to connect your Ambient Lockit / NanoLockit boxes to a Sony FX 9 and make the camera accept the external Timecode (LTC) source.
    Turn on all your Lockit devices, choose one of them to be the Master Clock - then press-and-hold the green button to broadcast timecode and framerate through ACN and you are set.
    To make properly work connect one Lockit device to each camera - constantly via a fitting cable, in this case the LTC-OUT (ambient.de/en/... )
    Switch the camera’s timecode interface to "In" - as you want to feed in timecode.
    In the camera’s advanced menu - which will require a long press on the menu button - navigate to TC/Media, then Timecode.
    Select “Free Run” Timecode and as a mode choose “Preset” (yes “Preset” and not “Regen” as you might expect)
    Now the camera accepts the external Timecode source - indicated by the “EXT-LK” sign above the Timecode.
    For safety it’s always a good idea to compare the TC on the camera display with the display on your Lockit.
    Learn more about Lockit Timecode here: ambient.de/tim...
    #timecode #nanolockit #lockit #sync #lockitslate #syncbox #genlock #1stac #dit #cameraoperator #boomoperator #setlife #soundmixer #boomop #cameradepartment #soundrecording #wireless #lockitplus #boompole #betterthanbluetooth #soundrecordist #camera #sound #acn #filmmaking #ambient #behindthescenes #locationsoundmixer