Why Excess foaming in the aeration tank | Trouble shooting |

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ต.ค. 2024
  • Hey guys, here is a troubleshoot video for access form in the aeration tank. as per your request I brought to you this troubleshoot video. there are many types of foaming in aeration tank of an effluent treatment plant and there are various reason behind this. let's check it out what are the reasons and what are the corrective actions of these. please like, share, comment and subscribe the channel.
    #nurtureflora #wastemanagement #wastewater
    #etpknowledgejunction
    #science_classes
    #sludge_volume_index
    #chemical_oxygen_demand
    #biochemical_oxygen_demand #Importance_of_BOD_and_COD #Wastewater_treatment #waste_water_treatment #activated_sludge_process
    #sanjeet_rawat
    #microorganisms_and_BOD
    #food_and_mass_ratio
    Watch the full videos and keep supporting the channel.
    Standard procedure for analysis of mlvss and mlss::
    • Procedure of MLSS and ...
    Standard procedure for Analysis of Dissolve Oxygen::
    • Dissolved oxygen analy...
    Standard procedure for chemical oxygen demand::
    • Chemical oxygen demand...
    effluent treatment plant :: • What is Effluent treat...
    you can ask any question to us by social media and we will try to solve your queries so please follow us on social media.
    Stay tuned with the science classes by following on social media:
    Facebook:: / scienceclassesofficial
    Instagram:: / iamsanjeetrawat (personal)
    / etpknowledgejunction
    facebook Group::
    / 154870968535789
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 216

  • @ETPKnowledgeJunction
    @ETPKnowledgeJunction  5 ปีที่แล้ว +3

    अगली वीडियो किस विषय पर होनी चाहिए? अपनी राय दें।

    • @qurantheguidanceforjannah1233
      @qurantheguidanceforjannah1233 5 ปีที่แล้ว +1

      Designing of MBR system

    • @SourabhKumar-sx8sl
      @SourabhKumar-sx8sl 5 ปีที่แล้ว +1

      sir UASBR pr

    • @yogeshsawkare6457
      @yogeshsawkare6457 4 ปีที่แล้ว +1

      Why increasing pH aeration tank without any activity. With aeration tank. How to control neutral pH aeration tank. OK suggest.

    • @vaibhavkanchanwar1991
      @vaibhavkanchanwar1991 4 ปีที่แล้ว +1

      how to remove Ammonium Nitrate (1-3 %) from Effluent

    • @chetanchouhan4156
      @chetanchouhan4156 4 ปีที่แล้ว +1

      ETP me Sewage ka water and effluent dono mix hota ha to kya hotahe?

  • @ghufrankhan5690
    @ghufrankhan5690 5 ปีที่แล้ว +2

    Thanks 🙏 for your time and effort to make it work and I look forward to working with your ideas

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @ghufrankhan5690
    @ghufrankhan5690 5 ปีที่แล้ว +3

    Can you please define FOOD MASS ratio calculations.
    So can we easily aware of what is going on around

  • @sachinsharmaweareone8823
    @sachinsharmaweareone8823 4 ปีที่แล้ว +2

    Sir eske alava aur kiya problam aah skti hai areation me

  • @faizantanha4275
    @faizantanha4275 5 ปีที่แล้ว +2

    Sir aap ki sabhi video mast h
    Or jyada video upload kro....
    Or sir mujhe FM Ratio calculate krne k lye koi formula btaiye

  • @PushpendraSingh-ye3lg
    @PushpendraSingh-ye3lg 3 ปีที่แล้ว +1

    Nice👍

  • @studysgood5027
    @studysgood5027 5 ปีที่แล้ว +3

    Sirr next video on finding SPGR by bottle method

  • @ranjitsingh2559
    @ranjitsingh2559 ปีที่แล้ว +1

    Thank you sir

  • @ravindranathmishra8172
    @ravindranathmishra8172 3 ปีที่แล้ว +1

    Dear sir, in our plant,aeration tank sludge is same as you explained.

  • @jitendrasutariya1604
    @jitendrasutariya1604 4 ปีที่แล้ว +1

    Good

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @JitenderKumar-rc7he
    @JitenderKumar-rc7he ปีที่แล้ว +1

    Hlo sr
    Agr water 💦 hi Access Foaming vala ho tb hm usko kese treat krege .
    Please answer.

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  ปีที่แล้ว

      Primary stag pr hi foam collect kro. Ho sakta h ki apke equalization tank me foam bn rha ho...wo low pH ki wajah se bhi bnta h.. karan pta kro aur use khatam karne ki koshis kro..
      Thanks dear stay connected ❤️

  • @mshanter4763
    @mshanter4763 3 ปีที่แล้ว +1

    Thanks Sir

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @trollbuddy---
    @trollbuddy--- 3 ปีที่แล้ว +2

    Sir while atfd operating time if we feed concentration water to atfd the salt is like resuidue plz reply me urgent

  • @surajitbhowmik3310
    @surajitbhowmik3310 4 ปีที่แล้ว +2

    Sir why mlss growth is excess? And it is not sitting properly? And secandary clarifier upper portion is full of sludge?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      th-cam.com/video/0MPfrQV1df0/w-d-xo.html

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      th-cam.com/video/uDmOwjY1sMo/w-d-xo.html
      Watch this videos this will definitely help you and stay connected thanks there

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      Watch these both videos

  • @rudrapratapsingh5556
    @rudrapratapsingh5556 3 ปีที่แล้ว +1

    Areation mai white fomimg or secondary clerifire mai bulk mai sluge aana

  • @sanjeevkumar-fj2gy
    @sanjeevkumar-fj2gy ปีที่แล้ว

    Bubbles in door PDP..what are probable reasons and how to solve it.

  • @rajgaud5647
    @rajgaud5647 3 ปีที่แล้ว +1

    Thanks

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      Please give feedback on Google. I'll really appreciate your affort.
      www.google.com/search?client=ms-android-hmd-rev2&v=12.41.19.23.arm64&biw=360&bih=680&hl=en-IN&cs=1&cds=3&sxsrf=AOaemvIzueUL9C-v3wLYyzb_re6-DsfbAQ:1636132655500&q=ETP+Knowledge+Junction&ludocid=10613794015523516759&gsas=1&client=ms-android-hmd-rev2&v=12.41.19.23.arm64&ibp=gwp;0,7&lsig=AB86z5X_8cmg42jEZu-x7Z7AFGoY&kgs=ef8a0066d99bbc7b&shndl=-1&source=sh/x/kp/local/4&entrypoint=sh/x/kp/local

  • @Gulves_khan
    @Gulves_khan ปีที่แล้ว +1

    Sir hamre S.T.P ke Aeration tank me bahut jada jhag ban rahe hai es ka koi upaye bataye hamra plant 3 saal purana hai

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  ปีที่แล้ว

      Hi gulves,
      Jaise ki video me btaya gya h ki foam kis peakaar ka ban rha h... apko bhi usi k anusaar samsya ko samjhna h aur upay karna hai.
      Thanks dear stay connected ❤️

  • @harishsingh855
    @harishsingh855 5 ปีที่แล้ว +3

    Poor settling ki problm ho rahi hai ..Good & fast settling ke liye kya karna chahiye ..I'm very worried for its problm

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Means aapke secondary clarifier me sludge settle nahi ho rha h..Or supernant ke saath bahar aa rha h?

    • @harishsingh855
      @harishsingh855 5 ปีที่แล้ว +1

      @@ETPKnowledgeJunction iska solution to btao kya kar skte h ise sahi karne ke liye

    • @ashishkumar0651
      @ashishkumar0651 5 ปีที่แล้ว +1

      Bhai pH curection and DAP dose karo .

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Mujhe samajh mein nahi aaya Tumhara question

    • @harishsingh855
      @harishsingh855 5 ปีที่แล้ว +1

      @@ETPKnowledgeJunction ha yahi problm ho rhi h supernant bahar aa rha h

  • @sumitrudola5922
    @sumitrudola5922 5 ปีที่แล้ว +2

    Dear sir
    can it happens due to selector zone is chocked permanently in STP sbr?

  • @vivekilozhlkhaddar5244
    @vivekilozhlkhaddar5244 5 ปีที่แล้ว +2

    Sir , aeration tank main jo air blowers lagatey hai , uski capacity kis baat par depend karegi

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +8

      Aapke aeration tank ke size pe or usme treated hone wale effluent ke quantity or quality pr. Means roz kitna KL treatment hona h or bod/cod load kitna hoga.. channel se jude rhen or video achhi lg rhi hn toh oro ko bhi forward kijiye🙏
      "Desh or channel ke vikas me apna amulya yogdan dijiye"

    • @GujaratiLokDayaro
      @GujaratiLokDayaro 4 ปีที่แล้ว +1

      Aeration design and how much load of BOD and COD

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      !!!

  • @ashishkumar0651
    @ashishkumar0651 5 ปีที่แล้ว +1

    Sir good morning
    Sir kya aap mujhe ye Bata sakte hai MLSS , RAS WAS me kya sambandh hai MATLAB ki inko kis tarah manage karte hai .ls per bhi koi video bhi banaye please.

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +3

      Mlss ka mtlb h total suspended solids.. bacteria bhi or baki ka suspended matter bhi jo aapke aeration tank me h.
      MLVSS ka mtlb h... Aapke bacteria jo COD ka digestion kr rhe hn..
      WAS ka mtlb h waste sludge jo aap sludge bed me drain maroge..Jb sludge jyada ho jata h aeration tank me.
      RAS means jo sludge aapka return aata h settler me se aeration tank me..
      Dekho sludge drain marna h ya return krna h.. ye aapko pta hona chahiye.. aapke aeration tank ko dekhkar

    • @ashishkumar0651
      @ashishkumar0651 5 ปีที่แล้ว +1

      Thanks sir

  • @SauravKumar-hm9un
    @SauravKumar-hm9un 5 ปีที่แล้ว +2

    Bod analysis and dilution preparation pr bhi video upload kre..

  • @punittyagi7979
    @punittyagi7979 3 ปีที่แล้ว +1

    Please share the information of feed well drum for stp and ETP

  • @vipulkumar9962
    @vipulkumar9962 5 ปีที่แล้ว +2

    RAS and WAS Calculation formula kya hai sir please reply?

  • @dipakkhatri3581
    @dipakkhatri3581 2 ปีที่แล้ว +1

    Feed and RAS ratio?

  • @revabhaipatel7330
    @revabhaipatel7330 2 ปีที่แล้ว +1

    Sir your advise so good, sir I am running comon effluent treatment plant so our effluent is not same regular main problem is our mlss not increasing we are using cow dung for that is it write?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      Join telegram group etp knowledge junction and ask ur queries there.

    • @ahmedalishah9815
      @ahmedalishah9815 ปีที่แล้ว +1

      use Bioculture regularly to increase bacterial growth

  • @dipakkhatri3581
    @dipakkhatri3581 2 ปีที่แล้ว +2

    Return activated sludge standard flow rate ?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      It could be around 25 % of the outlet flow but can be adjusted as per the fm ratio.
      For more clearity watch ACTIVATED SLUDGE PROCESS VIDEO.

    • @dipakkhatri3581
      @dipakkhatri3581 2 ปีที่แล้ว

      Thank you so much....😊

  • @anilahire2300
    @anilahire2300 5 ปีที่แล้ว +1

    B.O.D KYA HAI SIR

  • @Rajesh_Mangela
    @Rajesh_Mangela 4 ปีที่แล้ว +1

    Sarji aeration me problem aarahi hai paani poora dundhala hai kya hum useme polyelectrolyte add ker sakate hai

  • @sanjaykadam9098
    @sanjaykadam9098 4 ปีที่แล้ว +1

    Sir fom kose type ke.thik hay Aur organic and inorganic kay hay

  • @sagarj8099
    @sagarj8099 3 ปีที่แล้ว +2

    Can Excess aeration cause foam???

  • @prahladsinghchouhan2821
    @prahladsinghchouhan2821 4 ปีที่แล้ว +2

    Sir sodium hypochlorite me chlorine testing methods samjavo mere ko chlorine testing karni he plz

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      join telegram group ETP Knowledge group.

    • @map0093
      @map0093 7 หลายเดือนก่อน

      ​@@ETPKnowledgeJunctionsir where is the joining link..

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  7 หลายเดือนก่อน

      Search on telegram

  • @watersolutions901
    @watersolutions901 5 ปีที่แล้ว +1

    hello sir aaj hum ne etp strat kiya to aeration tank me whit fuming ho raha tha fir bad me band ho gaya to koi problem to nahi ho gi bectoria ban ne me, ur hum ne ph 10 rakha hey

  • @vishallone6804
    @vishallone6804 ปีที่แล้ว

    Areation मै BOD कि मात्र कीतनी होनी चाहीये

  • @satishdashsatishchand3712
    @satishdashsatishchand3712 3 ปีที่แล้ว

    MBBR mai sir from bala jhag kish liquid sai khatam hota hai

  • @lutfullah93
    @lutfullah93 4 ปีที่แล้ว +1

    Sir mere areation tank me white foaming ho rahi hai bhut zeyada lagbhag 1.5 fit height ho rahi foaming ki plz help

  • @SourabhKumar-sx8sl
    @SourabhKumar-sx8sl 5 ปีที่แล้ว +3

    Sir how to check FM ratio

  • @dileeprawat1627
    @dileeprawat1627 2 ปีที่แล้ว +1

    Bad stetting se kaise bachav kare Aeration tank k

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      Channel me jakar dekhna poor settling pr videos bnai gai hnn

  • @singwithss2824
    @singwithss2824 4 ปีที่แล้ว +1

    Ph aeration tank ka badh gaya ho aur smell bhi aa raha ho tab kya karna hai please reply sir ji din me kam foming ho raha aur rat me foming jyada ho raha hai

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      लगता है आपके एशियन टैंक मैं फीडिंग ज्यादा हो रहा है और फॉर्मिंग गाड़ी हो रही है अपने इनकमिंग इनफ्लूएंट का वीएफए आर अल्कलिनिटी टेस्ट कीजिए anaerobic tank ka Vga and alkalinity test kro.

  • @sachinsharmaweareone8823
    @sachinsharmaweareone8823 4 ปีที่แล้ว +1

    Sir agr final water ka colote white sa hone lage toh eska kiya reson hai

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      Aapka TSS bdha h... means feeding jyada ho rahi h ya MLSS km ho gya h

  • @sanjaykumarrewadia8556
    @sanjaykumarrewadia8556 4 ปีที่แล้ว +1

    sir sstank me pani keep upar sludge aa raha h pls problem meet out kare

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      th-cam.com/video/uDmOwjY1sMo/w-d-xo.html Sludge floating

  • @mrmaniar1555
    @mrmaniar1555 5 ปีที่แล้ว +1

    Pura etp with parameters k sath samjhao

  • @deepakyadav-xe1jh
    @deepakyadav-xe1jh 5 ปีที่แล้ว +1

    Sir aeration tank ka pH low 4.5 ho raha please aap mujhe batao ki kay problem ha jo ARETION acidic ho ra ha

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Aapke aeration tank mein acidification reaction chalu ho chuki hai...aapke dwara and treated effluent ki feeding ki gai hai vah bhi adhik Matra mein... Is samasya ka nivaaran Karen.. rph badhane ke liye soda lime ka istemal Karen

    • @chetanchouhan4156
      @chetanchouhan4156 4 ปีที่แล้ว

      Hamre aeration tank me bhi hota tha,but vaha aeration tank me caustic soda flakes ki dosing karva di ,

  • @VinodKumar-wy9ks
    @VinodKumar-wy9ks 3 ปีที่แล้ว +1

    Namaste sir ji
    Sir hamara STP ka aertion Black ho gaya he or clearyfire bhi poora kala ho gaya he sir kiya kare helf me please

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  3 ปีที่แล้ว +1

      D.O. kitna h..tank ka??

    • @VinodKumar-wy9ks
      @VinodKumar-wy9ks 3 ปีที่แล้ว

      @@ETPKnowledgeJunction 5 ppm he DO kese Kam hogi

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  3 ปีที่แล้ว

      Dost tank ki capacity kitni h or feed cod kitni h or kitna KL feeding hoti h.

  • @amolwani9343
    @amolwani9343 3 ปีที่แล้ว +1

    Why use 2kg of uria and 2kg dap in etp plant

  • @vivekilozhlkhaddar5244
    @vivekilozhlkhaddar5244 5 ปีที่แล้ว +1

    Sir ji ; YADI tank size 1400 METER qu aur effluent 1000 METER qu ; effluent water cod in aeration 1000 hai to hum kaise nirdharit karege ki kitni air ki jaroorat hai ; sir koi formula ho to pls bataiyega thanks sir

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +1

      Sorry... Mujhe apke tank size aur effluent ki quantity samajh mein nahi aayi Agar aapke aeration tank may already air blower installed hai to aap DO check kare agar aapka DO Kam ya jayada hai to aapko aeration badhane yeah ghatane Ki Zaroorat h. tank size ya effluent quantity ke hisab se hai air blower ki avashyakta hoti hai Ye calculation engineer Hi Bata sakta hai.

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +1

      Aur agar aap Yeh kehna chahte hain ki aap kya tank ka size 14 KL hai aur aapka daily feeding 1kl hai aur COD 1000 milligrams per litre hai to aap ko bahut kam aeration ki avashyakta padegi. aapko 2 HP ke blower se Kaam Ki avashyakta padegi.

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +1

      Please question ko dhang se likhe Aur phir main aapko aapka answer batata hoon

    • @shoiabansari4695
      @shoiabansari4695 5 ปีที่แล้ว

      @@ETPKnowledgeJunction sir i want to know how to calculate required aur in tank ... if any farmula to calculate the air required plz tell me

  • @rubalsharma4105
    @rubalsharma4105 4 ปีที่แล้ว +1

    Secondary tank me culture up ho raha he kya karn he

  • @prakashpatil-iy9gq
    @prakashpatil-iy9gq 2 ปีที่แล้ว +1

    Sir my airation tank ph 5.0 how to increase it

  • @dipakkhatri3581
    @dipakkhatri3581 2 ปีที่แล้ว +1

    Chloride effect of Aeration tank?

  • @bhaveshpatel3042
    @bhaveshpatel3042 5 ปีที่แล้ว +1

    Sacandrey tank me 3 din se uper bhut sludg aa rha he so pls kaya karne se sludge niche Bethe ga

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      First floating sludge is most often caused by:  Denitrification - small nitrogen gas bubbles float the sludge in the clarifier creating
      floating sludge chunks with small bubbles entrapped
       Fats, Oils & Grease - simply put, FOG floats on water. When entrapped in floc,
      excessive grease or oil can cause floating biomass. This appears as a scum blanket that
      can cover the entire clarifier.  Viscous bulking or billowing sludge - viscous bulking can sometimes create floating
      sludge (more often it is just billowing over the weir versus floating). This is often caused
      by nutrient deficiencies (normally low phosphate) in industrial waters.
      Solutions to floating sludge:  Denitrification problems can be often controlled by increasing the recycle pump to
      reduce sludge blanket depth/sludge retention time in the clarifier. The problem is often
      related to an increase in influent ammonia/nitrogen that is converted by beneficial
      nitrifiers into NO2 or NO3 via the autotrophic nitrification process. Without an anaerobic/anoxic step that removes NO2 or NO3 in the treatment system, this process
      occurs in the clarifier. Long run solutions include evaluating influent TKN/ammonia,
      anoxic denitrification zone residence time, availability of “food” or easily available BOD
      in the anoxic zone for denitficiation, and an overall system survey on sludge age,
      residence times, and influent makeup.  Fats, Oils & Grease - FOG created floating sludge involves a messy control process.
      First the scum/floating sludge needs to be removed or allowed to carry over the weir to
      polishing/tertiary treatment. Upstream, operators need to evaluate where the FOG
      increase originated. This can be a one-time slug or increased loadings of grease over
      time. It is best to prevent oils and grease from entering the biological treatment system. In
      cases where we have high levels of FOG in a system we encourage operators to increase
      wasting rates (remove entrapped FOG this way) and add cultures associated with FOG
      degradation/biosurfactant production. By using wasting and seeding steps together, the
      potential for significant biomass reduction is prevented while removing entrapped FOG
      that causes high effluent solids.  Viscous Bulking - solution here is to evaluate changes in influent makeup and changes
      in the environmental conditions in the biological treatment unit. While researching the
      exact cause of the bulking, operators need to begin wasting the bulking, viscous sludge. If
      nutrient residuals are low (

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      th-cam.com/video/kKGh_UkmIeI/w-d-xo.html

  • @rahulku9207
    @rahulku9207 5 ปีที่แล้ว +1

    Sr normal mai bataye.
    Agar 2400m3 ka aeristion tank mai foming ho rhi hai to kya and koun se se kary kre ki.
    Foming last ho.
    Please

    • @rahulku9207
      @rahulku9207 5 ปีที่แล้ว

      Color halka yellow and red ho gya hai .

  • @madansinghchambyal5568
    @madansinghchambyal5568 5 ปีที่แล้ว +2

    Sir do ko kam or yada kaise kre

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว +1

      Sabse phle aapko pta krna h ki kya reasons ho skte hnn km ya jyada hone k.. km ke reason hn ki.. ya toh bod load jyada h or aeration bhi km hnn . Or jyada h toh ho sakta h ki aeration jyada h or bod load km h or aapka sludge level bhi km h....
      Channel se jude rahiye.. iske upar bhi ek video aayegi or video achhi lagri hnn toh oro ko bhi forward kijiye🙏

  • @harivansh1337
    @harivansh1337 2 ปีที่แล้ว +1

    D pharma dalne se bhi nhi kam hota h foming dusra upay bataiye

  • @jagdishdevasi6280
    @jagdishdevasi6280 5 ปีที่แล้ว

    Sir fm ratio kese nikalte he

  • @zubairamjad7994
    @zubairamjad7994 2 ปีที่แล้ว +2

    Are MLSS and TSS the same thing?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      No.. TSS means any physical impurity, may be dead bacteria that are suspended.
      And
      MLSS mean both bead and live bacteria in suspended

    • @zubairamjad7994
      @zubairamjad7994 2 ปีที่แล้ว

      @@ETPKnowledgeJunction thanks Can you suggest to me a good coagulant for the textile wastewater?

  • @chetanchouhan4156
    @chetanchouhan4156 4 ปีที่แล้ว +1

    Aeration tank me Sewage ka water direct Dete he ki nahi?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      Depends on cod of effluent

    • @chetanchouhan4156
      @chetanchouhan4156 4 ปีที่แล้ว +1

      Sewage ke water se to bacteria banta he Na sir...

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      Sewage hi unka khana hai

    • @chetanchouhan4156
      @chetanchouhan4156 4 ปีที่แล้ว +1

      Sewage ko aeration tank se pehle treatment ki jaroorat nahi he ya he???

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว +1

      Rukiye aap is video ko dekhiae. FIR agar koi problem hogi to mujhe batana. Main aapki har prakar ki samasya ko solve karne ki puri koshish karunga
      th-cam.com/video/rZv2bwwmwMc/w-d-xo.html

  • @manishdixit9584
    @manishdixit9584 5 ปีที่แล้ว

    Enumerate how to do MLSS development

  • @ravindrachauhanrajput7814
    @ravindrachauhanrajput7814 2 ปีที่แล้ว

    Suldge halka ho gya h settling suldge ni ho rha settle ho rha h ...kya krna cahiye

  • @ramesht9122
    @ramesht9122 5 ปีที่แล้ว +1

    Sir mera etp 50 kl ka hai aur air blower 5H.P ka hai
    But sludge dablaf nahi hota hai aur hota bhi hai to secondary clairyfei
    Dawar out ho jata hai aeriation tank Mai sludge rukta nahi hai sir kripya is ke bare Mai bataye

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Settling kitni aari h?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      DO Kitna h?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Feeding COD aur Aeration tank ka COD Kitna h?

    • @ramesht9122
      @ramesht9122 5 ปีที่แล้ว

      @@ETPKnowledgeJunction sir cod reactor outlet aur final outlet ke Liya jata hai na

    • @ramesht9122
      @ramesht9122 5 ปีที่แล้ว +2

      Sir par day 24 k.l outlet hota hai
      Aur cod 6 month par third party ke dawara check karaya jata hai
      Pichle Baar karaye the to reactor outlet cod 175 mg/L tha
      Aur final outlet ka 125 M.g/L tha

  • @etpstpworking8129
    @etpstpworking8129 3 ปีที่แล้ว +1

    Sarya USB Kya Hota Hai Kaun Sa ETP mein hai ya

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  3 ปีที่แล้ว

      Upflow anaerobic sludge blanket (UASB) technology, normally referred to as UASB reactor, is a form of anaerobic digester that is used for wastewater treatment.

    • @etpstpworking8129
      @etpstpworking8129 3 ปีที่แล้ว

      USB ke upar Sar ek video banaaiye

    • @etpstpworking8129
      @etpstpworking8129 3 ปีที่แล้ว

      Se USB ka process Jarur batana Hai Sar Mujhe iska kya kaise karna hai dialister ks

    • @etpstpworking8129
      @etpstpworking8129 3 ปีที่แล้ว +1

      @@ETPKnowledgeJunction Sar USB ke bare mein Jarur batana Mujhe iska kya process hai

  • @DharmendraSingh-zm8jh
    @DharmendraSingh-zm8jh 4 ปีที่แล้ว +2

    Bod videos pls provide sir

  • @sunilkumar-lu4fo
    @sunilkumar-lu4fo 3 ปีที่แล้ว

    Sir
    We have use biological ETP plant in textile company. After primary treatment (alum, CR, Lime and poly dosing) we have get pel yellow color water. Pls suggest.

  • @vipulkumar9962
    @vipulkumar9962 5 ปีที่แล้ว +1

    ETP plant Process design calculation kya hai

  • @adarshrathour5766
    @adarshrathour5766 5 ปีที่แล้ว

    Jar testing ki video bnayi sir

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  5 ปีที่แล้ว

      Video toh possible nahi ho payegi... sorry for that.
      JAR TEST
      The dose of the coagulant to be used can be determined via the jar test.The jar test involves exposing same volume samples of the water to be treated to different doses of the coagulant and then simultaneously mixing the samples at a constant rapid mixing time.The microfloc formed after coagulation further undergoes flocculation and is allowed to settle. Then the turbidity of the samples is measured and the dose with the lowest turbidity can be said to be optimum.

  • @rohitsarvan9821
    @rohitsarvan9821 3 ปีที่แล้ว +1

    Sir limit of fm ratio

  • @shamashyashamadhan3951
    @shamashyashamadhan3951 3 ปีที่แล้ว +1

    Secondary tank Bron battar problam

  • @harivansh1337
    @harivansh1337 2 ปีที่แล้ว +1

    Costik ka was watarr h 1dam black h foming bhut hota h

  • @rachanam8512
    @rachanam8512 ปีที่แล้ว +1

    Thank you foaming problem by me can I have ur no for further discussion

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  ปีที่แล้ว

      Thanks...stay connected
      sanjeetrawat684@gmail.com is our email address.

    • @aimysk
      @aimysk ปีที่แล้ว

      Medam deformer use

  • @ParveenKumar-qb9kb
    @ParveenKumar-qb9kb 4 ปีที่แล้ว +1

    Sir mea etp oprator hu mere leyea ko etp couras hai plzz Reply

  • @abdulkhalid7502
    @abdulkhalid7502 8 หลายเดือนก่อน

    FO G HIGH CAUSE INFULENT ETP

  • @gpnfolkmusic5367
    @gpnfolkmusic5367 5 ปีที่แล้ว

    Aeration tank ka colour black ho gaya he

  • @prahladsinghchouhan2821
    @prahladsinghchouhan2821 4 ปีที่แล้ว +1

    SSV between SVI

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      SSV means SETTLED SLUDGE VOLUME: The volume of settled sludge after 30 minute sedimentation V30.
      SVI means SLUDGE VOLUME INDEX= SSV/MLSS

  • @RameshYadav-rh
    @RameshYadav-rh 3 หลายเดือนก่อน

    Hello sir

  • @singwithss2824
    @singwithss2824 4 ปีที่แล้ว

    Aeration tank ph-8.8 ho gaya hai

  • @ramesht9122
    @ramesht9122 5 ปีที่แล้ว

    Sir aap ka no. Mil Sakta hai kya

  • @rahulparmar9187
    @rahulparmar9187 3 ปีที่แล้ว

    Barabar dikh nahi raha he

  • @noor03250
    @noor03250 2 ปีที่แล้ว

    Please provide pdf

  • @mangeshbahirat9609
    @mangeshbahirat9609 2 ปีที่แล้ว +1

    Sir aapaka number milega

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat

  • @RameshYadav-rh
    @RameshYadav-rh 3 หลายเดือนก่อน

    Sir please reply

  • @qurantheguidanceforjannah1233
    @qurantheguidanceforjannah1233 5 ปีที่แล้ว

    Dear thoda aur Technically samjhao, aisa lag aap khud samjhne ki ashish kar rahe ho...

  • @earningpoint2674
    @earningpoint2674 5 ปีที่แล้ว +2

    thank you sir

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @SourabhKumar-sx8sl
    @SourabhKumar-sx8sl 4 ปีที่แล้ว +1

    Sir mere second..... Send suludge uth rha h Kya kru plant ko manage kaise kru

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 ปีที่แล้ว

      Explain whole thing

    • @kapilverma2546
      @kapilverma2546 4 ปีที่แล้ว +1

      Em solution bda do
      Or Areation limit me kro or pani ka inlet discharge limit me kro

    • @SourabhKumar-sx8sl
      @SourabhKumar-sx8sl 4 ปีที่แล้ว

      @@ETPKnowledgeJunction mere ETP Mai secondary se sludge aa RHA h milk factory h sir or sludge ka problem bhi h solution please

    • @SourabhKumar-sx8sl
      @SourabhKumar-sx8sl 4 ปีที่แล้ว

      @@kapilverma2546 sir FM ratio kaise check kre please reply

  • @noor03250
    @noor03250 2 ปีที่แล้ว +1

    Thank you sir

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 ปีที่แล้ว

      Thanks dear.
      If ETP Knowledge Junction has have ever helped you. Please leave a review to grow the business.
      Puruwala, Paonta Sahib, Himachal Pradesh 173025 g.co/kgs/TGatLm