TEST FOR WORKABILITY OF CONCRETE - SLUMP CONE
ฝัง
- เผยแพร่เมื่อ 4 ก.ย. 2014
- The ease with which one can use concrete is called workability. It is one of the physical parameters of concrete which affects the finesse, strength and durability. Here’s how you can check the workability of your concrete.
- วิทยาศาสตร์และเทคโนโลยี
For everyones benefit, acceptable safe slump for reinforced foundation walls/footings/pavement 25-80mm, beams/columns 25-80mm, slab 50-100mm, piling 100-150mm. Beyond these values are not safe.
Thanks man
As per IS 1199 slump cone is filled in four layer,so don't confuse with comments. This video is wonderful and precise
th-cam.com/video/q0G17VnmZG8/w-d-xo.html
Wrong
Not ASTM C 143 but Indian Standard (IS-1199) ?
Hey fantastic work guys. Thank you for explaining it well - very helpful!
"First you need to steal a traffic cone"
lol
You can order on Amazon
Amazing, clean explanation .
Very simple nice explanation, Thanks a lot.
Well explain and simplified. Thanks ultra pls keep educating the world with all ur heart. I enjoyed your video.
I like your teaching method and the way you share the knowledge. 👍👍 Keep up the productive work.
Hello,
We are happy you found this useful. For more information on home building you can visit our TH-cam channel th-cam.com/users/UltraTechCementLimited
Regards,
Team UltraTech
it is a good work guys pls do the exact procedure for consistency, initial and final setting time of cement
What a useful and clear explanation thank you 🌹
Thanks for explaining the information in such a way that everyone can understand. Good lesson.
We are happy you found this useful. For more information on home building you can visit our website www.ultratechcement.com .
Regards,
Team UltraTech.
rotate of the cone to create collapsible and shear slump should be lifting gratually
Slump test express the consistency of concrete mix, workability is measured by " Compacting factor" or " Remoulding test by Jolting" or " V.B test".
I actually picked out a real practical in slump test. But I never got the accepted height or ranges of heights that are good
AWESOME, now I can go take my GC exam!!! :)
We need more videos related to this and also construction sites
Thank you DCRM!
Thanks for this explanation now I can defend my project well
Hello,
We are happy you found this useful. For more information on home building you can visit our TH-cam channel th-cam.com/video/71PJC4j1FHU/w-d-xo.html .
Regards,
Team UltraTech.
well explanation sir thank you......
Thank you sir..
Clear explanation...
MAJOR CIVIL ENGINEERING TESTS
Very nice explanation this videos
Very helpful...thanq
Thank you ultra tech. This helps me for my lab exam preparation
Hello,
We are happy you found this useful. For more information on the home building, you can visit our TH-cam channel - th-cam.com/users/UltraTechCementLimited
Regards,
Team UltraTech
Very nice advice
Useful information.. appreciated
Hello,
We are happy you found this useful. For more information on home building you can visit our TH-cam channel th-cam.com/users/UltraTechCementLimited Regards,
Team UltraTech.
Great work
I watched a 5 hour pour of a hotel foundation in Spain and not one slump test was undertaken.
Goodluck on that building! 😅
Thank you sir
Nice practical i appreciate you sir
Very helpful of concrete workability test
Thank you
very good lecture.
Why was no information given on how much slump is ideal?
Good test
simply superb........
Nice information
ATSM C143: "Immediately remove the mold by raising the mold in a steady, vertical direction. *** There should
be no lateral or torsional motion of the mold while lifting. ***"
Yep, i don't know what code does this channel is following.
th-cam.com/video/eymDP1_oHbo/w-d-xo.html
good test
very good voice and pronunciation
Why is it undesirable for a shear or collapsable slump test? Its great to know what is preferred but equally important to understand why
I get that but what are the dangers when contractors the slump test fails and contractors use it anyways. I say this because many contractors provide shotty work. In what ways does it effect the integrity of the concrete? Are their any telling signs?
Aside from affecting ease of work (pouring using pumpcrete tend to be difficult if slump is too low), it may result to severe honeycombing on structural members, reducing integrity of the structure.
*Point To be Noted:-* Slump length measured from UP Side 🙂
Interesting video
Hello,
We are happy you found this useful. For more information on home building you can visit our TH-cam channel th-cam.com/users/UltraTechCementLimited
Regards,
Team UltraTech
I had done in lab of BCE Bhagalpur
no rotation allowed when lifting the cone see ASTM C143
Carefully in a vertical direction. By a steady upward lift with no lateral or torsional motion.
Some more information...is desired!!
Best quality
thank you so much sir very help full
walal seetahey good job hadan halkan wax ka baraneysid ila soo xiriir hada u baahatid in si fcn usii fahantid.Hadii ad ACI test sameyneysid ninkan qaabkisa ha raacin waayo waa khalad waadna ku dhaceysa taas ogow.
Nice
slump cone also out of calibration and slump should not be rotate while lifting
10
and for the blows not go proper (final layer)
what is the range of slump height for a concrete to have a good workability?
50 TO 75 MM
Very help full
fantastic work
THANKS,ULTRATECH ......
Thanks
Superb
Great information here. Thank you so much sir
Why frustrum of cone shape is preferred for slump test please explain
to maintain the potential energy of the concrete along the height
Exaplained very simply. thankyou
You're welcome. Hope you found the above information useful. 😊
@@UltraTechCementLimitedyes, it is very useful for me.
We are happy you found this useful. For more information on the home building, you can visit our TH-cam channel - th-cam.com/video/71PJC4j1FHU/w-d-xo.html.
Regards,
Team UltraTech
The slump mold is filled in three layers (ACI grade 1). Not in four layers like you said. Sorry wrong.
Dear.....they're perfect.check your basics once again.
Good stuff engineer. Well explained
Hi Michael,
We are happy you found this useful. For more information on the home building, you can visit our TH-cam channel bit.ly/3kimz2w.
Regards,
Team UltraTech.
I am getting zero slump . what should I do? please help
Thank you.
How do you analyze the results after measuring the slump
pick up true slump results as ideal choice.
thank u sir ....
Watching this video just minutes before exam
Sir, what are the slump values for different work like road , slab , columns etc.???
5 inch
In Australia for normal concrete we mix 20mpa 20mm aggregate 80 mm slump when it is being tested . A wetting agent can be added after the test to make the concrete easier to work .
Thank you bra now I have practical view of slump test
Great
Thank u sir
How to take the water content???
Slump cone is rotating while lifting the slump cone. it is lifted in vertically and check the measurement.
Please vee-bee cosistometer test ke baare me bataye
nice
Tnx brooo
what is green concrete bro explain
Nice explanation
Hello Tanjim, we are glad you think this, for more information about us, please do visit www.ultratechcement.com . Regards, Team UltraTech.
cool
ok.. what causes shear and collapsible slump and is it best for lantern or beams..because concrete needs for such work should be collapsible so that it may fill up all air bubbles in concrete
Hi Abid,
Thank you for your query. Our experts will answer your question shortly.
Meanwhile, you can watch homebuilding-related videos here - th-cam.com/users/UltraTechCementLimited
Regards,
Team UltraTech
Hello,
We would like to inform you that shear or collapse slumps in concrete are due to the majorly wrong proportioning of aggregates, higher water-cement ratio, and maybe the wrong dosage of admixture. Hope this solves your query.
Regards,
Team UltraTech
What is the procedure for Slump test with Egg shell powder as 10% replacement of cement??
Dear Sakshat, please message us your location in detail, our team will get back to you.
@@UltraTechCementLimitedWhatsapp Number please
The ease with which Ultra-tech explains the concept and things is called workability of ultra-Tech...
Subscribe,like,comment kar diye
RIST walei 🙌🏻
Is it 1/4 of the ht or the volume? Thanks for the reply
Height
How to do it according to astm c143 standard
CiviLab is a multilingual civil engineering laboratory software (English & French), which allows you to carry out the tests with your preferred language and to print the results with another language, designed by civil engineers to meet your expectations, our software allows you to manage the tests carried out within your laboratory with remarkable flexibility and reliability. Easiness of usage, allowing members of your laboratory to master CiviLab in record time.
CiviLab manage the following tests:
Geometric properties (density, Water content, Void ratio ...etc.);
Grain size distribution test;
Atterberg limits test;
Sand equivalent test;
Micro deval test;
Los angeles test;
Proctor test;
Direct shear test at the Casagrande box
Oedometric test;
Drill hole log;
Heavy dynamic penetrometer test;
Menard pressuremeter test
Concrete Formulation (Dreux- Gorisse).
Concrete Formulation (Bolomey);
Concrete Formulation (Faury);
Compression test on concrete;
Ultrasonic Testing;
Bitumen Extraction test;
Bulk density of bituminous specimen;
in situ compaction controle.
More details www.dzlogiciels.com
hi. just wondering. If the cone if filled, should the cone be lifted right away it is filled or should i wait for 1 or 2 minutes? thanks
once you filled the cone you should lift it right away
thank you!
gud
Which code dictates that the slump cone is filled in 4 layers?
IS 516, IS 1199
Sir please tell that how optimum moisture content is achieved on the site
I want this
I started hallow bricks unit so i want this mixture
Hello Pampapathi, could you please elaborate your query?
Regards,
Team UltraTech.
What is the IS code used
Now 3 layers... New code.. some one told please reply any one three layers or four layers
Process bhi to bataeye kayse kiya jata hai
What test method is this? you are not following ASTM C143 or AASHTO T119
BL Lippe. .
Blippi
砂利が多いし、5cmでこの水加減…
後、スランプコーンひねったら正確な数値にはならないかと。突き方にもムラがあったし、3層目なんか突き棒が先しか刺さってない。
あれじゃ崩れますよ…
I don't know China
tamp free fall?
Three layers only as the size of the cone is too small
Md firoz ansari test of concrete
Pls explain all physical and chemical test of purpose and pls explain Tamil
Dear Ashok, could you please elaborate on your query?
I need video or book in tamil language to understand the chemical and physical test for concrete (fresh concrete and harden concrete) and all raw materials of concrete
Dear Ashok, as of now we don't
have any literature in Tamil. Please message us your contact details, our technical team will solve your query.