  • Simple video showing you some basics on how to troubleshoot the compressor on your refrigerator. This will work on most refrigerators, they all will pretty much test the same. This test can be used for top freezers, side by sides, freezers and french door models.
    Thanks for Watching!
    If you have any questions please leave them in the comment section.
    Be sure to subscribe to my channel and give this video a thumbs up if you liked it.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 264

  • @VICTORAPPAW
    @VICTORAPPAW 10 วันที่ผ่านมา

    Thanks a lot. You have made me breathe a sigh of relief. You have also confirmed my my fears of being duped by an unfaithful repairer. Thanks a lot. I will do will to change my contactors

  • @pvezmar4133
    @pvezmar4133 10 ปีที่แล้ว +4

    Dude! You are the man! Haven't found my problem yet but you are a master teacher! Thank you for all your electrical information!

  • @chrismaya3796
    @chrismaya3796 7 ปีที่แล้ว +1

    Thank you. You showed me how to diagnose, fix, and save myself a lot of money. I spent 20 bucks to fix the fridge. thanks again!

  • @robertwoodson4129
    @robertwoodson4129 4 ปีที่แล้ว

    Thanks for the detail explanation. My Kenmore stopped working and I did various checks. Eventually determined that the amperage draw from the compressor was about .5 amp. I felt it was low on Freon R-134a, although I was not certain. I feel better now that you have confirmed my thought. Thank you very much for providing excellent supplementary information.

  • @ronaldrichards4978
    @ronaldrichards4978 5 ปีที่แล้ว +1

    Great video, and a simple way to test the correct operation of the compressor, compressor overload and relay switches. The video also has helped me to know how to correctly utilize my new amp clamp-on meter; it is always good to know what are the correct volt/amp ranges a good compressor system should have. Thanks!

  • @dgdiyer1191
    @dgdiyer1191 3 ปีที่แล้ว +1

    Nice job on this video. I like that you showed amp readings near the end of it. My compressor runs all the time, is hot and can't get the freezer below 6-7° F. Because it runs continuously at 1.5 amps and is 16 years old, I concluded, after checking everything else out, that the compressor is slowly on its way out.

  • @danielbrittz3764
    @danielbrittz3764 2 ปีที่แล้ว +2

    Thank you Bill. Your TH-cam diy video extremely helpful here in South Africa where technical info is limited or non existent. Appreciate you sharing your kind and helpful experience to get things going again 😁🤟

  • @dudjois9928
    @dudjois9928 5 ปีที่แล้ว

    Thank you! your videos helped me diagnose my Samsung fridge. I replaced a faulty relay that connects to the compressor. Compressor looked dead but it was the relay not driving the voltage. You saved me money!

  • @ryk1265
    @ryk1265 10 ปีที่แล้ว +3

    Excellent and crystal clear instruction!

    • @BillNewberry
      @BillNewberry  10 ปีที่แล้ว +1

      Thank You and Thanks for Watching!

  • @mayjahcon4662
    @mayjahcon4662 8 ปีที่แล้ว

    Love love love ur vids man! I'm a student for hvac n I'm learning the basics n fixing window units n refrigerators n ur vids help me out a lot! Thanks bill!

  • @Kstevieg
    @Kstevieg 9 ปีที่แล้ว

    This was excellent, Bill. I followed your logic and am sure I can duplicate the process on my own refrigerator tomorrow. There was no 'dead air' time in your explanation.

  • @8642hugo
    @8642hugo 5 ปีที่แล้ว

    My Daewoo fridge kept making clicking noises for a while, 3 months, until it finally stopped cooling. Compressor fan was working, the compressor sounded like it was working but very weak. The freezer wasn’t working either. Saw this video and replaced the compressor relay like the one on the video. Cost $35 on eBay.
    It’s working great now!...Thanks this video was really helpful.

  • @charlesmwangi164
    @charlesmwangi164 2 ปีที่แล้ว

    Wonderful job on this video. Great, you're a blessing to humanity.

  • @redhottlady6384
    @redhottlady6384 ปีที่แล้ว

    Excellent video. I have an LG French door fridge with a freezer that stop freezing but the both the freezer and fridge was cool. Ice cream was not. I called a appliance repair guy out to diagnosed and he spent less than 5 minutes, never did an ohm test said the compressor was bad because it was hot. Cost to repair $1400. Changed me $85 service call. My friend is going to follow your video and perform the tests to check for to see if the compressor reading indicate a bad compressor or possibly a bad relay.

  • @sandyeeta
    @sandyeeta 8 ปีที่แล้ว

    Hey, Bill. Thanks very much for taking time to post this helpful info. I have a deep freeze that has no condenser fan. It uses the outside skin of the freezer to dissipate the heat. Over several weeks, it cooled less and less. A new one would set me back $700 or more. Seems pretty obvious that it is low on refrigerant but I would like to confirm this somehow.
    Continuity between compressor terminals says no short or bad windings. Compressor starts and seems to run smoothly, using about 1.2 amps starting up on a warm freezer compartment after the freezer has been off overnight. Thermostat appears to be working but it seems obvious that it is OK since power is getting to the compressor. I know that many air-conditioning compressors have a delay circuit to keep the compressor from trying to start up too soon after a shut down. I think understand that this is due to high pressures remaining in the refrigerant lines right after shutting down, which would put great load on the compressor, causing excessively high amperage if it were to try to start up again too soon. I'm guessing that the pressures equalize over a few minutes, making it easier for the compressor to restart at that time. My freezer is an Embraco and the tag says 17.7 RLA, which I understand it the maximum amperage on start up. Sure enough, if I let it run for a while, then shut off power, then restore power after a few seconds, I see a little over 17 amps on startup. My question is, does this high 're-start' amperage right after a shutdown an indication that there is freon in the unit? If no refrigerant, would there be high pressure at all? Or, maybe the compressor is just compressing regular air, which I assume is what would be in the lines if a leak let all of the refrigerant out.
    So, my questions are, does high re-start amperage confirm anything about whether the compressor is working or not? And, does it tell me anything about if there is any/enough refrigerant in the system? Is there a way to confirm low refrigerant, and if everything checks out OK, would it make sense to put more refrigerant in it, or would it just leak out again? Finally, I understand that the compressors with capillary tubes are very sensitive to having the right amount of charge in them. Whether trying to re-charge the old compressor, or replacing it with a new one, it seems like measuring the refrigerant load might require some more technical knowledge.

  • @francisco.prosario5681
    @francisco.prosario5681 5 ปีที่แล้ว

    Very detailed and clear instructions. Thanks

  • @samd2783
    @samd2783 5 ปีที่แล้ว +2

    you are awsome thank you for all your hard work and great videos.

  • @johncosta2392
    @johncosta2392 2 ปีที่แล้ว

    Thank Bill. Excellent video, I followed your instructions purchased a 3+1 compressor started. 2.85Amps my refrigerator is headed to the graveyard.

  • @WillPowerRhythm
    @WillPowerRhythm 9 ปีที่แล้ว +1

    good info, not wasting much time explaining.

  • @PaulLisaBradford
    @PaulLisaBradford 10 ปีที่แล้ว

    Thanks for the video! This help me replace the relay on my compressor and test my compressor..

  • @deadjuggalo1991
    @deadjuggalo1991 10 ปีที่แล้ว +6

    Well relay came in yesterday took 5 min to install plugged it in and works good compressor came right on

  • @DrainoRemarkable
    @DrainoRemarkable 10 ปีที่แล้ว

    dude thnx alot for the video im studying to be a tech at a trade school and this right here is helping alot , ive been wondering how to fix this problem for a really long time ive finally found it thanks to you, thanks bud.

  • @BobMock
    @BobMock 10 ปีที่แล้ว

    Thanks for this video. It was very helpful while I try to figure out why my fridge quit

  • @Solutions-ky9sh
    @Solutions-ky9sh 2 ปีที่แล้ว

    Excellent. VEry informative and clear. Thank you !

  • @teekay8134
    @teekay8134 4 ปีที่แล้ว

    Great video... Explained perfectly ...Thanks

  • @yktm_jashi9042
    @yktm_jashi9042 3 ปีที่แล้ว

    clear, concise, professional demeanor and professionally described problem and solution. Excellent video. I subscribed to the channel.

  • @johnwhite1608
    @johnwhite1608 2 ปีที่แล้ว

    great video, well explained. thank you

  • @CinemaSasquatch
    @CinemaSasquatch 10 ปีที่แล้ว

    Very good and easy to understand.

  • @user-hk8px4zq1m
    @user-hk8px4zq1m ปีที่แล้ว

    Super helpful video.

  • @wooswim7561
    @wooswim7561 9 ปีที่แล้ว +2

    Thx was a lot of help

  • @floridasaltlife
    @floridasaltlife 9 ปีที่แล้ว

    Great video Bill !! I wish I'd of researched more a while back when I replaced an ice maker in my boat due to a stalled compressor, $1800 !!!! Who knows what I might of found...

  • @josevega2851
    @josevega2851 2 ปีที่แล้ว

    You r the best, very detailed concepts, I have warm refrigerator, frozen good and evaporated fan works some times only , thanks in advance, keep going like that, help me a lot , thanks

  • @thomaswerts2418
    @thomaswerts2418 8 ปีที่แล้ว

    Great job Bill

  • @onesearcher100
    @onesearcher100 8 ปีที่แล้ว

    thank you.. very helpful

  • @dffdixie88
    @dffdixie88 6 ปีที่แล้ว

    Hey Bill, I got the same setup as your working on here, the fan is running an you can put your hand on the compressor an feel it vibrating but it's not making a noise like it's kicking in.... an all the copper lines are warm except foir one an it's just a little cool

  • @jay63ish
    @jay63ish 9 ปีที่แล้ว

    Thank u on this it help -- I check the oooms n found low test on run an start an tell me from three to two fasse like brokin motor

  • @3006USMC
    @3006USMC 10 ปีที่แล้ว +3

    @6:43- just check frost pattern on evap, that will tell you a lot. And the comp can be running and still not cooling- broken rod or bad valves or like u said a hole somewhere and there is no freon. Great vid thanks for sharing.

    • @BillNewberry
      @BillNewberry  10 ปีที่แล้ว

      I will end up doing a couple more videos on this refrigerator. I will be sure to explain that in another one. Frost pattern, like you said will tell you alot. Thanks for the great comment and thanks for Watching! Semper Fi

  • @henrylove6250
    @henrylove6250 9 ปีที่แล้ว

    Bill, awsome video, my freezer stopped cooling adequately. There is the issue of the "thermistor" that I saw on another video. But I will test the relayer first, based on this video.

  • @SalgadoMark
    @SalgadoMark 10 ปีที่แล้ว

    Thanks bro. I just fixed my sisters refrigerator by watching your videos. Not this one in particular, but I did watch a lot of them that I found helpful. I bought a 3 in 1 for $12 on Amazon. Saved a lot of money!!! Thanks!!!

    • @BillNewberry
      @BillNewberry  10 ปีที่แล้ว

      If you just bought a 3 n 1, watch the video I just uploaded this morning.
      Thanks for Watching!

    • @SalgadoMark
      @SalgadoMark 10 ปีที่แล้ว

      I did good advice. But since we're in a pinch for money I will be keeping the 3 in 1. I'll let you know if anything goes wrong. In the meantime its working great.

    • @jeresuno
      @jeresuno 10 ปีที่แล้ว

      Some repair guy supposedly fixed our fridge but its still not cooling like it should=(

  • @mamnyelraptorbenitez9483
    @mamnyelraptorbenitez9483 5 ปีที่แล้ว

    thanks bro love your videos

  • @charlesmwangi164
    @charlesmwangi164 2 ปีที่แล้ว

    Thank you teacher Bill for your time. Am your student. Watching from kenya

  • @robviolin1
    @robviolin1 9 ปีที่แล้ว

    Helps a lot, thanks.

    • @BillNewberry
      @BillNewberry  9 ปีที่แล้ว

      robviolin1 Your Welcome!

  • @MrMac5150
    @MrMac5150 10 ปีที่แล้ว +7

    Very nice video, important things like seeing a load on a circuit, well done.
    I would like you do one diagnosing a clogged evaporator officer and one on knowing if the refrigerant is under or over filled both real good topics, please keep up the good work.

  • @63mx1
    @63mx1 หลายเดือนก่อน

    Great vid!

  • @johnny96888
    @johnny96888 2 ปีที่แล้ว

    Bill you the man!

  • @swampfizz
    @swampfizz 10 ปีที่แล้ว

    thanks much.this is what toutube people are all about.you saved me a 100 bucks

  • @oldskoolfunk71
    @oldskoolfunk71 10 ปีที่แล้ว +2

    Great Video Bill, thanks for the detailed content going to diagnose mine right now. repair guy just came out and did nothing. Just said its a bad compressor Im on it thanks to you Vid God bless.

    • @Fernando-wd5tc
      @Fernando-wd5tc 3 ปีที่แล้ว

      was it a bad compressor?

    • @shamsulrizal3872
      @shamsulrizal3872 2 ปีที่แล้ว

      @@Fernando-wd5tc ñb b by BBB b BByffjjkb by bbnvknccnbnnnbbnmbmnncnnvvmn. Mvmvnn

  • @josesantos-hn8ho
    @josesantos-hn8ho 8 ปีที่แล้ว

    thanx Bill greate video

  • @rlfrohs
    @rlfrohs 8 ปีที่แล้ว

    Thank you!

  • @victorvillafane252
    @victorvillafane252 4 ปีที่แล้ว

    Nice video sir you are a man thank you

  • @sailorchaos1274
    @sailorchaos1274 10 ปีที่แล้ว

    thanks Bill!

  • @MTTRON
    @MTTRON 10 ปีที่แล้ว +2

    Hey Bill,
    First off thank you for your killer videos. They are very informative!
    My question is: What range can the compressor reading be to still be good?
    IE if the two bottom posts are around 7 or 8 would that be to low?

  • @sonyjoelbagaoisan7
    @sonyjoelbagaoisan7 6 ปีที่แล้ว

    Thanks for giving me this channel which everyone can watch and I learn too many things to you such as troubleshooting compressor, not cooling refrigerator, bi metal, thermostat timer and cold control too. I wish for your good heart and sharing your skills to me. Do you have a book author by you?

  • @airpolice40
    @airpolice40 9 ปีที่แล้ว +1

    Hi Bill, Great video!!! I have a kitchenaid ksrs25ftms00 Refrigerator that is not cooling on either side. I checked the compressor and it test's fine. The Compressor Fan does not turn on nor does it have power to it. What could the problem be? Any help is appreciated. Thanks!!!

  • @scottstansbury4924
    @scottstansbury4924 4 ปีที่แล้ว

    Thanks for your very informative video,no one has ever explained that you should have different levels of resistance between the 3 pins. What does it mean when I have the same level of resistance between the 3? I have used 3 different multi-meters to test with and they all read the same.

  • @diamondjim9695
    @diamondjim9695 8 ปีที่แล้ว

    Thanks Bill this was a great help. I removed the relay and it rattled so I ordered a new one. However when I checked the 3 pins on the compressor I got a reading from pin to pin as if I was shorting out the 2 test terminals 0.00! Testing each pin between a chassis ground I get nothing! Confused on what this means?

  • @charleshumphreyjr7003
    @charleshumphreyjr7003 6 ปีที่แล้ว

    mr. Newberry love the video but wanted to know what you did with the extra blue wire when your brother brothers refrigerator two Blues one black when you hook up a kit thanks

  • @laoamerica
    @laoamerica 8 ปีที่แล้ว

    Very good thanks

  • @shellymoore656
    @shellymoore656 9 ปีที่แล้ว +1

    This video is awesome and really appreciated! We have this exact same problem on the exact same fridge. Thanks a million. Things like this are so helpful. We have a repair guy coming Tuesday and it's nice to know the issues and test them before they come. We have replied the capacitor and the relay timer before. We are going to do it one more time today to see if the part is bad because it worked last time. TBH, this fridge has been nothing but problems. You were awesome. Gonna share with followers on Twitter.

  • @kennethwright4497
    @kennethwright4497 7 หลายเดือนก่อน

    Thumbs up thank you

  • @ronsecondamendment2359
    @ronsecondamendment2359 10 ปีที่แล้ว

    Good video.

  • @andycao4547
    @andycao4547 6 ปีที่แล้ว

    hello Bill
    I considering about my compresser went noisy , can you tell me how much pressure when compressor working?

  • @roberts1159
    @roberts1159 3 ปีที่แล้ว

    Nice job of explaining the start relay and capacitor replacement. However just wondering why you didn’t do a quick check of the compressor windings first ? That was mentioned at first, then you went right into replacing parts. I had a similar situation of no cooling and common to start was open. Compressor was less than 2 months old !

  • @peterradtke532
    @peterradtke532 8 ปีที่แล้ว +1

    Hi Bill,Thank you for this very helpful video! I have 2 questions:1) where can I buy a relay. The one I have on my Arctic Air fridge looks exactly like the one you show in your video.2) if the compressor is shot, is it worth repairing it?Thanx much Peter

  • @murraymadness4674
    @murraymadness4674 3 ปีที่แล้ว

    Great video(s). I have been tearing down fridges for the insulation, and now am trying to fix a couple. Have two where the compressors run, but no cooling.
    The bigger one, it was pulling vaccuum at the suction, so it appeared to have blocked cap tube, which after opening them all up seemed to be the case.
    Any tips on how to determine if there is blockage in the lines, or leaks and not enough freon if compressor running ok? thanks

  • @pvezmar4133
    @pvezmar4133 10 ปีที่แล้ว

    Alright Bill, I have 120v going to relay. Relay clicks and I'm near positive it turns the compressor on as it is vibrating and making a small hum. I have not tested resistance on thermostat in fridge or freezer yet but besides those do I test resistance of compressor next to see if it's that?

  • @namedward7454
    @namedward7454 8 ปีที่แล้ว

    Bill, Great videos!! Used the 3N1 RCO410 on my GE refrigerator/freezer TFX25ZPBE , and she started and is working. I am however drawing 2.45 amps consistently. Any recommended actions to look for other issues that could cause this?

  • @MsTmccall
    @MsTmccall 9 ปีที่แล้ว

    Hi Bill, thanks for the informative video. I have a Kenmore side by side that isn't cooling or freezing. I'm getting a reading of .56 from the relay wires. The fan is running. Do I need to replace the start relay or is the compressor itself going bad?

  • @warrenwhyte9108
    @warrenwhyte9108 8 ปีที่แล้ว +1

    Thanks Bill your video was very good. I have a Hi-sense fridge that trips my RCD after it has been running for about 10hrs. Why does this happen? Can you help me?
    Thanks Warren

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices6926 2 หลายเดือนก่อน +1

    Just serviced one yesterday. But the compressor was not doing anything, and there was zero activity. Changed relay and away she ran. Easy service call.

  • @samd2783
    @samd2783 5 ปีที่แล้ว

    you make perfect sence and your videos are super awsome. I checked the voltage on the compresser relay and it gave 122 volts on both sides of the lower piece. Its a 2 piece relay and the positive on that relay is on the top side. the circuit board did some clicking before the 122.2 volt displayed on both bottom sides of relay.
    I checked the ohms on the compresser it was bottom two 12.1, left side 9.0, right side 3.3, i know the videos were saying 10 by 6 by 4. Is my compressor off and bad.
    Thanks again for all your videos. the compressor runs with the fan, it seems as if the vibration on it is not very strong it is a little hot and the copper pipes out of it the one to the condenser was little warm then it did not feel as warm the other one fealt little cooler. the whole issue started with the freezer being over icing. do you think it is low on freon, i have never had yo add to it before, and it is 11 years old and both fridge and freezer are out.
    the compresser seems like it quiets down as it runs even more.
    i put a clamp amp meter to the wire harness going to the compressor and it gave me 0.13amp. i had it set on 2-20 amps ac.

  • @Bolicheh
    @Bolicheh 9 ปีที่แล้ว

    Thanks Bill for all the info re my fridge that wouldn't cool. After trouble shooting with your videos I found the compressor relay to be faulty due to a pin that had rusted, or burned out. replaced it with a 25 dollar one and off and running.
    I especially liked the Rooster in the video. Good sense of humor, tanks again

  • @cmmorgan834
    @cmmorgan834 6 ปีที่แล้ว +1

    Great Video, Question, I have a GE side by side refrig with Freezer on bottom, The refrigerator works fine but the bottom Freezer doesn't freeze, Compressor doesn't come on, Fan is running, Also just cleared the drain line that was leaking water..would you have any suggestions.. Thanks.

  • @qosmioamit
    @qosmioamit 8 ปีที่แล้ว

    Bill
    I have a mini fridge. Magic Chef MCBR360HBF. It stopped working and during my troubleshooting, I isolated the wiring to the compressor and did the resistance check across the 3 pins of the compressor in the same order as you showed in the video. I got 7 ohm on the first check across the bottom two pins, and then 1 on the left and top pins, and 1 on the right and top pins. Is there a short?

  • @aussiejace8572
    @aussiejace8572 6 ปีที่แล้ว

    liked your videos etc.. i have a samsung rs21 fridge freezer combo have changed the relay at the motor control board and still the relays click on and off on the compressor any thoughts...

  • @johnpicarojr.4618
    @johnpicarojr.4618 7 ปีที่แล้ว +1

    Got a question; my fridge... being old... it a GE.. gonna say its 15+ years old.. but noticed its been running long last few days... and i shut it down for an hour... and replugged it in.. hit the reset button, put water in the ice trays... and it turned into cubes.. and fridge is nice and cold.. but its running for 20 minutes + and stays off for about 10-13 minutes... any signs? compressor is warm to the touch, but not hot.. any suggestions

  • @lambach2990
    @lambach2990 9 ปีที่แล้ว

    Hi Bill,
    Nice video, this compressor of yours i see the copper pipes there, the one that is near the relay that you switched out is that the recharge/valve from factory that is bent and sealed? On the right side of your compressor are those the high and low copper pipe? My particular compressor one copper pipe the high side one is cut/capped and bent. On the right side of mine has the low copper pipe that run up to freezer, and the factory recharge pipe bent. What happen if I cut the one on the left and join it (not sure if the repairman did that or not but they also took the relay switch as well.) back do I loose the vacuumed and Freon from the compressor? this fridge was gifted from a neighbor. Since then I bought a new relay switch, plugged it in and now hear the compressor but nothing is cooling still. Could it be that pipe is not feeding Freon up to freezer and fridge?

  • @bobfulgham6571
    @bobfulgham6571 9 ปีที่แล้ว

    Bill, please disregard my recent post. Latter part of post was correct. first part was incorrect. Still checking. tutorial is big help to me. Thanks : Bob

  • @richardricard6682
    @richardricard6682 6 ปีที่แล้ว +1

    Have a Frigidaire Freezer that stopped working again. The last time I tapped the fan and it started working and lasted for about 2 months. This morning i noticed the freezer was not working and again the fan was cutting in and out. Could the problem be to simply replace the fan?

  • @TSPhotoAtlanta
    @TSPhotoAtlanta 9 ปีที่แล้ว

    Thanks for the video. I'm off to test my compact freezer NOW. My one complaint probably would be that you don't show the relay very well, or talk much about it or how to replace it -- which if often obvious once you know what you're lookin' for...then I looked to the right, here on the page, and you have a separate video that shows all that "How to install a universal relay " Hey, thanks again!

    • @TSPhotoAtlanta
      @TSPhotoAtlanta 9 ปีที่แล้ว

      Back with results in a minute, but let me ask: relays blow for a reason. What is that reason? I pack my freezer with $$$ of meat, so if it's going to blow again and ruin another box full of meat, I'd rather know and fix that problem or buy new!
      Hey, any suggestions on a compact freezer (brand, model?) I would be looking in the 2.5 to 3.x cubic foot range. My Summit FS20 lasted 14 years and the only problem it ever had was icing -- it's a manual defrost model, so that is expected once or twice a year. I just need to go slightly larger (it was a 1.6cu' model.) Are Danby's any good -- like DUFM304A1WDB or Whynter -- CUF-210SS? The Danby is commonly sold and pretty low price. The Whynter is also around and neither as $$$ as Summit (probably all made in China.) But the Summit I know (or at least did, haha) and no one stocks them, and they cost the most: 2.8cu' ~= $429 delivered....

  • @georgekanaan3949
    @georgekanaan3949 2 ปีที่แล้ว

    Hi Bill, how are you, your video is very helpfull, I have an issue with my freedge that I read 1.6 ampere when he's sleeping, thank you.

  • @FountainCoinscom
    @FountainCoinscom 5 ปีที่แล้ว

    Thank you

  • @victorvillafane252
    @victorvillafane252 5 ปีที่แล้ว

    Nice video

  • @hondagoal
    @hondagoal 9 ปีที่แล้ว

    Thx for a great video. If you replaced the relay & cap and unit still clicks & stops after few seconds, would you say that compressor is bad. Possibly locked? (Already passed ohms test).

  • @DanielWagenheim
    @DanielWagenheim 10 ปีที่แล้ว

    Hey Bill, Thanks for another great video. Side Note: the original relay is initially on and then clicks off. 2 Questions: 1.When the wires to the original relay are running at 0.8amps does this mean the relay is bad? 2. If the freon may have escaped and isn't building any pressure, does this mean the compressor is bad or needs to be refiilled? Thanks!

  • @Dicofol1
    @Dicofol1 9 ปีที่แล้ว

    Have seen a decrease in quality of fridges and their compressor in general from older machine (20 or 30 years ago) ? They don't seem to last as long is this true ?
    Great video thanks.

  • @grilledchickenwrap
    @grilledchickenwrap 3 ปีที่แล้ว

    I followed your instruction on checking the compressor here are my 3 readings in the begining they jumped alot but eventually settled... 4.5 , 3.4 7.7 and I also checked the amperage draw... in the begining when compressor kicked on it was drawing 1.0 - 1.2 amps but eventually it dropped ton.88 amp. is my compressor still good or bad ? btw I have a LG MC57LAUM compressor..

  • @biancaleva
    @biancaleva 4 ปีที่แล้ว

    Hi and thank you for nice video, if you read this, maybe you can give me an advice on my fridge GE and is making high pitch nose and then goes away, but is still cooling.
    Would that be compressor? Thank you again!

  • @rx2008
    @rx2008 6 ปีที่แล้ว

    Hi Bill. Thanks for taking the time to make these videos. Have watched a bunch and still haven't quite figured out my problem... My Frigidaire side by side stopped cooling (both freezer and fridge). The evaporator fan and condenser fan both work, the compressor is running, all coils are clean, no dust / frost. The relay / capacitor is getting 120 volts. It's very difficult to get at the 3 terminals on the compressor to check for resistance so can't get a good read there, but nothing like the readings you indicate should be. According to this video, it's probably the compressor or the coolant - wondering if you have any other helpful hints. Thanks.

    • @Yuppp294
      @Yuppp294 6 ปีที่แล้ว

      I'm am currently having the same problem exact with my Frigidaire side by side. Did you find a solution? (My fridge temp is 60' and freezer 40')

  • @nigelblack528
    @nigelblack528 4 ปีที่แล้ว

    Nice video my fridg freezer is working but the top is not cooling properly its on but the temp has dropped very low also the freezer has been having a problem with bad frost build up if that helps. I'm trying to trouble shoot its an Amana BB20

  • @danielvillacres2083
    @danielvillacres2083 3 ปีที่แล้ว

    Great video! Do you happen to have on for connector?

  • @rphan2009
    @rphan2009 5 ปีที่แล้ว

    Hi bill, can you show me which website to buy fridge parts. Thank

  • @juansandoval1088
    @juansandoval1088 4 ปีที่แล้ว

    Cool bro

  • @Alexelectricalengineering
    @Alexelectricalengineering 8 ปีที่แล้ว

    Nice video :) Thumbs up :D
    Alex

  • @JohnRodriguez-zr5sl
    @JohnRodriguez-zr5sl 3 ปีที่แล้ว

    Hi Bill I have changed the relay and the capacitor for the compressor and the evapororator fan is running. When i plug the unit in i hear a click the compressor kicks in and then shuts off. I just watched your great video on how to check the compressor which I will do tonight. if the compressor checks good what next. Thanks John

  • @leonelmartinez1464
    @leonelmartinez1464 5 ปีที่แล้ว

    hi sr i have a question I got a LG refrigerator and I wanted to ask you if this kind of refrigerator have a relay or not all of The refrigerators have one?

  • @MinamiSen
    @MinamiSen 3 ปีที่แล้ว

    can you buy any off the shelf generic compressor to place the original one?

  • @cptrun61
    @cptrun61 9 ปีที่แล้ว

    I got a Haier vine cooler with two compartment ,practically new little over 1 year old, of course I did not got the extended warranty. Couple of days ago the inside lights came on and stayed on .I did unplugged the unit for a full day than plugged back on, problem was fixed. Yesterday start to make a very loud sound coming from the back of the unit.The digital panel with the temperature display also stop working . Do you have any idea what could be the problem? Appreciated

  • @allenbutler8520
    @allenbutler8520 10 ปีที่แล้ว

    Hey I watched a couple of your videos. My compressor will click on for like 3 seconds and shut off. It does this every few minutes or so. I put a brand new relay and still the same problem. I checked the pins on the compressor and it looks like it's alright. any ideas??

  • @danielcooper9854
    @danielcooper9854 8 ปีที่แล้ว

    cheers bill