ISO 26262 - Hardware Level of Functional Safety

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ม.ค. 2025

ความคิดเห็น • 11

  • @romu9999
    @romu9999 2 ปีที่แล้ว +1

    Ones again, many thanks Dr Petry, I'm always return to your very well done didactic videos when I'm feel confused :-)

  • @ULSolutionsSIS
    @ULSolutionsSIS  3 ปีที่แล้ว +3

    By the way: We are working on a new pocket guide - Automotive SPICE goes Mechatronics. Therein you can find the HW-relevant processes required by the intacs™ HW SPICE process assessment model. We contributed to this PAM as co-lead. There are also links between HW development from the SPICE perspective and ISO 26262, with publication scheduled for September. Stay tuned.

  • @priteshbhimani7825
    @priteshbhimani7825 3 ปีที่แล้ว +1

    Video content is well structured and nice.It touches all the crucial concept of ISO 26262.

    • @ULSolutionsSIS
      @ULSolutionsSIS  3 ปีที่แล้ว +1

      Thank you very much for your feedback - we really appreciate it! :)

  • @sukanyakoppala4970
    @sukanyakoppala4970 3 ปีที่แล้ว +1

    Thanks for your videos.waiting for more videos, especially work break down structure considering tasks w.r.t ASPICE and functional safety standards.

    • @ULSolutionsSIS
      @ULSolutionsSIS  3 ปีที่แล้ว +3

      @sukanya koppala - we've heard your call, and we'll response ;): The next release will be SWE.4, SW Unit Verification. And then, a very long tutorial on FS related development on SW level is in after production. Hope we can deliver this video e/o September.

  • @bharathsk2007
    @bharathsk2007 2 ปีที่แล้ว +2

    Hello Dr. Perry. this is best short video covered iso26262 HW. Do you please let me know some more example of HSR? Any reference will be helpful. Thanks in advance

    • @ULSolutionsSIS
      @ULSolutionsSIS  2 ปีที่แล้ว

      @bharath great question. Here are examples of HSRs from some of our training material:
      • The seat sensor shall signal “unoccupied” when no object is on the seat or if object weight < 5 kg.
      • A stuck at closed of S2 shall be detected and a reset of both µCs shall be initiated in case of stuck at closed.
      • The activation signals of the ATD µC and the Safety µC for the switches shall be compared for equality and a reset shall be initiated if they are contradictory.
      • The comparator shall detect contradictory signal values not faster than 200 msec.
      • The comparator shall detect contradictory signal values latest after 600 msec.
      These requirements are allocated to certain parts of the hardware.
      We hope this helps you further!

    • @bharathsk2007
      @bharathsk2007 2 ปีที่แล้ว

      @@ULSolutionsSIS . Perfect! Thanks for the reply.

  • @saishanmu
    @saishanmu 3 ปีที่แล้ว +1

    Hello ..Thanks for the videos ..I have been following since part 1 .. The part 6 explanation is missing . Can you let me know where can I find ..Thanks in advance!!! ☺️☺️

    • @ULSolutionsSIS
      @ULSolutionsSIS  3 ปีที่แล้ว +2

      Part 6, the FS development on SW level, is currently in post-production. The release is scheduled for September or October. Since this video will be more extensive than other videos in our series, we cannot promise the release date.