Aslamoalykum please tell repair this heater in lahore because electrication put replace fuse 120 instead put 220 volt fuse and heater not working and electrication didn't know about repair heater please tell me what to do......thanks
Assalamuelikum sir mere pass Ak japni heater Aya he is ka scr1 Jo k transistor ki trha he or geya he is ka no nhi he jab k scr2 jo he wo s04c6 he. kya ye dono no seem ho ga .or is ki jga kon sa transistor LGA skata hon please rhnomai frmaye
Good work 🌹🌹🌹🌹
V good
Thankssss bhai
Keep it up, good work 👍
Bother code 62 aaa raha ha heater be aap wala ha jis ke vedio bana rahe ha heater table se neache gera ha
Aslamoalykum please tell repair this heater in lahore because electrication put replace fuse 120 instead put 220 volt fuse and heater not working and electrication didn't know about repair heater please tell me what to do......thanks
یہ نئے ہیٹر آپ سے مل سکتے ھیں
کیا ؟؟؟؟؟؟؟؟؟؟؟؟؟؟
Direct lagany say Blower ki motor b khrab ho jati hy ?
Jo moter 5 wire wali ho wo kbhi kbhi kharab ho jati hi.2 wire wali kharab hony ky chance bht km hoty hain..
Salam walekum sar main fuzzy bhi change kar liya z nar bechain kar liya hai totab bhaiya on Nahin hua
Bhai heater chlty chlty off ho gya ha kea problem ho skti ha?
Is ki main supply check karain..ya main board ka fuse check karain...
Main transformer sy 114v a rhy hn or hearer k apny transformer sy b 15v or 24v out ho rhy hn
Assalamuelikum sir mere pass Ak japni heater Aya he is ka scr1 Jo k transistor ki trha he or geya he is ka no nhi he jab k scr2 jo he wo s04c6 he. kya ye dono no seem ho ga .or is ki jga kon sa transistor LGA skata hon please rhnomai frmaye
Is ki jaga pr doosra nmbr ni lgta is ky sath ka kisi doosry board se nikal ky lgana pry ga..
Or ye scr later ki aparking pr lga hota hai...
Ap ka heater masla kya kr raha hai..
Ye Kisi wja se blast ho geya he scr or muje khin SE mil nhi rha
Is ky baghair bhi chal jay ga...no isue..
Lakin voltage zyada milny se main transformer kharab ho jay ga...
Bhi app ki shop Khan par he
Lakin mera to 110 pe chalte chalte dead ho gya hai mumkin hai fuse ka hi masla ho ga.
Check karain.. baz dafa 110 v zyada ho jain to bhi dead ho jata hai....
Brother is model ma code 62 dey raha ha magar 20 min chalta ha pir band hu jata ha pir code aata ha code 62
Over heat ho raha hai...Is ka filter clean krwain..blower ky sath ...safai ky time blower ko ghoomny ni dain ni to blade toot jaty hain...
moter not working how to chek the card
Yr ma NY veristor change kea ha PHR b NAI on ho rha
Display on nahi ho raha
Supply voltage card mein aa rahey hein
Khana kha k check krta hn
Same problem hai
Code 62 kay hy
error 71 what it is?