Thank You Sir for in detsils explanetion. Sir, plz batay ki during repairing is isolation transforma se hum lok, technically shock se ksyse bach saktahay hay?? Video may Ap batay ki isolation transfor normally 1:1 hota hay matlab ,jitna Input hoga Output bhi utnahi hoga. IP=OP. Tab input 220V huya to Out put bhi 220V hi hoga, that mean out put ka potential difference is same as input . Tab 220v may jhatka to lag sakta hay. Hay na Sir G ?? Actually my purpose, DSO use karna , for smps circuiit repairing. I hope may apna issue thik se explain kiya hu. Thnx .
Sir i am having problem with isolation transformer. I have checked voltage b/w phase to neutral it is showing me 220 v and when i checked phase to earth it is showing me 110 V. When i removed isolation transformer everything is showing correct 220 v p to n and p to earth. Can you help me to resolve this issue
After doing 2 good earthing also my earthing value is 6.. tried all the best way for my industry.. wat to do now plz help out.. my machine need below 1V .. is it possible to bring down earthing value by isolation transformer??
I would like to know if a voltage stabilizer does the same function of isolation transformer for protection of all electrical and electronics equipment's in the home in villages where there's a lot of voltage fluctuations. Regards Joseph
Yes, a kind of isolation because it also employ transformer. Also, the modern stabilizers have a delay ckt, that will protect the system against transient currents.
Thankyou sir .. sir aisa lgta h video kabhi band hi na ho
Haha..... Thank u
Bahot simple method hai apki samjhane ki , thank you
First time i happened to see this channel. Very good explanation. Please keep on loading such informative things.
Itna simple tarikey se aapne smjhaya hai thank you so much sir ❤
Avi sirf 10K sir jald hi 1 lakh
Than 1 million😍... I just love him😍
Very nice,new topic
Awesome explanation 👏 👌
Excellent demonstration, keep it up, God bless you and thank you. I would like to know where this can be used in the home. Regards Joseph
Very nice explanation
Isolation Transformer wit 3 Wire AC Supply (Distribution)
This ll make Grid more Stable. Hence Less Failure
Very well explained. Thank you very much.
Thank for your knowledge 😊
great
Nice superb thanks sir ji
Complete explaination, thanks bro
BOHUT KHUB SIR
MICROTEK 3 KVA ONLINE PS MEIN KIYA ISOLLATION HAI. JARUR BATANA SIR
Thank You Sir for in detsils explanetion.
Sir, plz batay ki during repairing is isolation transforma se hum lok, technically shock se ksyse bach saktahay hay?? Video may Ap batay ki isolation transfor normally 1:1 hota hay matlab ,jitna Input hoga Output bhi utnahi hoga. IP=OP. Tab input 220V huya to Out put bhi 220V hi hoga, that mean out put ka potential difference is same as input . Tab 220v may jhatka to lag sakta hay. Hay na Sir G ??
Actually my purpose, DSO use karna , for smps circuiit repairing. I hope may apna issue thik se explain kiya hu.
Thnx .
एनर्जी सेविंग के परपज से कौन सा ट्रांसफार्मर लेना चाहिए
Great analysis
Great sir 👌
Output main L1 ko earth kar sakte Hain
Plz make a full course on rrb je and ssc je aspirants..
Lighting ke alwa kya use hai iska ??
Very good
Thank you so much sir 🙏
Good
Well explain
Refinery ma two generating station ko Unit ratio transformer se connect kiya ha uske baare ma Bata sakte ha kya?
Aik normal transformer ko Isolator Transformer bana sakty hen
Please share 3 phase induction motor and numerical problem
sir Smps me bhi use hota h kya
Sir, Our input is 110v and -110v. Can isolation transformer make it 230 volt and neutral ?
Thank you sir
Nutral to earth 3 to 1v very ho raha hai,1.5v constant ke liye kya karna hai 🙏
Kon kon device me isolation transformer use hote hai?
THANK YOU
Sir i am having problem with isolation transformer. I have checked voltage b/w phase to neutral it is showing me 220 v and when i checked phase to earth it is showing me 110 V. When i removed isolation transformer everything is showing correct 220 v p to n and p to earth. Can you help me to resolve this issue
Any idea please share with me
After doing 2 good earthing also my earthing value is 6.. tried all the best way for my industry.. wat to do now plz help out.. my machine need below 1V .. is it possible to bring down earthing value by isolation transformer??
I would like to know if a voltage stabilizer does the same function of isolation transformer for protection of all electrical and electronics equipment's in the home in villages where there's a lot of voltage fluctuations. Regards Joseph
Yes, a kind of isolation because it also employ transformer. Also, the modern stabilizers have a delay ckt, that will protect the system against transient currents.
No it doesn't
How the reduced Eddy current loss and hysteresis loss in transformer
I have already upload the lectures in transformers series.... Kindly check it
सर हमारा असउलएशन ट्रान्सफॉर्मर नुटल काम नाही कर रहा है
I have a normal transformer and I need Isolator Transformer
sir ek cnc machine ka Isolation transformer hai uski input 415 V hai but sir Output 500V aa rha hai ...
aisa kyu ho rha hai sir?
Isolation transformer can be steup up or step down.....
A simple transformer will also isolate the primary from secondary
Connect reverse.
Electrical shock kaise prevent karta hai
Ek hi bat bar bar repeat kyo kr rhe ho
Hi
super sir