@@racworld1365Can undercharging also cause suction pipe to freeze? How can undercharging be differentiated from overcharging when there is no way to measure pressure?
thanks very helpful , i knew my fridge had gas this guy just wanted to charge me extra for filling gas when the fridge didn't need it,now its over freezing ......
What a fantastic video i must say. But my question is are we going to let out some gas when the compressor is Off or On. Cos i think if it's ON the compressor will draw in air since he gauge is on the SUCTION side. Please clarify.
Acha naeem Bhai aik split a,c inverter Kenwood ,,,, wo hm ne cheek Kya Usme gas's nahe,,, JB hm ne uska indoor khola to Jo drain side hoty h,,, Waha per oil Aya ho tha,,,acha khassa,,,, hmne cooling coil ko pressure dya 500 psi,,,, ne coil ko Pani me bhe dip kya,,, leakeag kahe se bhe nhe Mili,,botel me sarf Dal k bhe chek Kya ,,,,Kya reason ho
Brother mere double door fridge mein problem a rahi hai, uss kah compressor heat ho keh trip kar raha hai, aur suction line par thodi thodi ice jammu rahi hai abhi garmi baut jaida hai, maine April mein new compressor dalwaya tha aur gas charge kitti see, uss time par garmi kam thi... Kya reason ho sakta hai compressor trip karne kah.... Abb maine small kitchen fan lagga rakha hai compressor keh pass cooling keh liya abb sahi hai?? Without fan kyon nhi chal rahi??? Plz help
Bhai मैंने fridge me gas dalwai hai जिसके baad commperser pipe per ice aa gayi hai जो थोड़ी देर बाद melt bhi ho jaati hai raat के time ice बहुत थी पर दिन में दो teen बार hi ice jami thi फिर भी commperser bahut garm hai
@@racworld1365 It’s R134A. I was told for R134A, the suction line pressure should be 22 psi and I need to add more r134a. In your video, the pressure is 0-2psi. I am confused. Thank you.
@@racworld1365 It’s frost free. It’s GE side by side GSH25JSRFSS 25 cu ft fridge. It has automatic defrost. I can hear fan inside freezer runs when the compressor runs.
Very nice informative clip
Thanks for your feedback
Your my best lecturer ever am becoming a great fridge tech because of your video
Thanks for your feedback
Thanks for English. You deserve a like.
Very helpful. I charged my refrigerator today to 3-4lbs and it froze. I will drop to 2lbs. Thx for the video.
I can clearly understand, perfect! Gracias friend
Thank you for making this very informative video.
Excellent 👍 information
Keep it up
Nice job .....I learn something
boht khub naeem sahab
well done guy I love your channel. im happy that you explained this in English.
Thanks👍,keep watching RAC world
@@racworld1365Can undercharging also cause suction pipe to freeze?
How can undercharging be differentiated from overcharging when there is no way to measure pressure?
@@adeyemibabatunde1814 no there will never ice comes on suction line when undercharging.
This is right 👍🏻 answer ❤
Really enjoyed
Very good explanation! Thanks❤
Welcome
Love U from kashmir
Thanks for great knowledge, but how can hold r134a gas pressure. Which have 8-10 or 12-15 psi in running mode. Kindly tell me
Excellent job
Thanks 👍 for your feedback
Keep watching RAC World 🌎
Very helpful
thanks very helpful , i knew my fridge had gas this guy just wanted to charge me extra for filling gas when the fridge didn't need it,now its over freezing ......
Good video, learn what's wrong with my fridge. Thanks.
Hmmm thats good
Keep watching RAC world
Very good information what size of compressor suction is two psi
All sizes of 134a refrigeratos
Thanks my friend God bless keep it up
Perfect
What a fantastic video i must say. But my question is are we going to let out some gas when the compressor is Off or On. Cos i think if it's ON the compressor will draw in air since he gauge is on the SUCTION side. Please clarify.
You can released gas even in on condition. Because it will not suck air inside when its running pressure is upper than zero psi.
But you can't released R600a refrigerant, while its compressor is on. Because it will suck air inside.
May Allah reward you abundantly. ❤🎉
@@Intygra
JAZAKALLAH
PlZz U can create next videos of the refrigerator
Naeem bhai apki video bhot help full hoti hai, apki shop kis area mai hai, apka mbl num mil sakta hai
How about R404a pressure psi sir?
👍👍👍👍👏👏👏👏
hallo bhaiya ple ME 134A GESS PARESSE 15PSI I CAN POSIBLE THIS ONLY 2PSI
0 psi is the correct. My technician said .it should be zero
sir but R134a ka running pressure 12-15 Psi hota hai.
Dear cooling complete honay k bad zero b hojata ha.
Ya between zero to 3psi
@@racworld1365 ok sir mai ne bhe yakhe qustion kia tha mujhy bhe jawab mil gia ...tnx sir
What is the pressure for Samsung double door 310 ltr fridge.
If not releases pressure any problems for fridge, technicians told me not a issues for ice for suction line
Sure it will harm your compressor pump. Because it is over gas charged
Is it ok to leave it sweating?
Yes
Acha naeem Bhai aik split a,c inverter Kenwood ,,,, wo hm ne cheek Kya Usme gas's nahe,,, JB hm ne uska indoor khola to Jo drain side hoty h,,, Waha per oil Aya ho tha,,,acha khassa,,,, hmne cooling coil ko pressure dya 500 psi,,,, ne coil ko Pani me bhe dip kya,,, leakeag kahe se bhe nhe Mili,,botel me sarf Dal k bhe chek Kya ,,,,Kya reason ho
Cooling coil is leaked
I had an experience of the suction line freeze and defrost by itself which causes the freezer not to freez inside. What should i do
Nice video.
Thanks
Will this stop de freezer from freezing
No
Sir agar r600 mail jab tandak pora hojai to ketne psi par ajata hai .plz sir
Zero or below than zero
(zero say b neechay)
Starting running pressure 8 and cooling complete pressure will down 3
To release extra gas from the refrigerator shall we switch off the fridge ?
Sir r134 ka runing prssure to 12 to 15psi runing pressure hai ..yakha par 2psi q set kr dia plz samjhaye mujhy
Dear cooling poori honay k bad pressure down hokar 2 say 5 psi par ajata ha,
Jitni achi quality ki gas Hogi , itnay Kam psi par charge hogi
@@racworld1365 tnx sir apke vidio buhut ache hai
Can I remove gas without that meter by placing finger on directly compresser
Yes you can, but maybe without meter you released extra gas 😜
Brother mere double door fridge mein problem a rahi hai, uss kah compressor heat ho keh trip kar raha hai, aur suction line par thodi thodi ice jammu rahi hai abhi garmi baut jaida hai, maine April mein new compressor dalwaya tha aur gas charge kitti see, uss time par garmi kam thi... Kya reason ho sakta hai compressor trip karne kah....
Abb maine small kitchen fan lagga rakha hai compressor keh pass cooling keh liya abb sahi hai??
Without fan kyon nhi chal rahi???
Plz help
What are side effects of this excess gas?
You removed gas when the fridge was running ? I mean, the compressor was working ?
Yes
Due to this reason, how much electricity is consumed in this matter?
What if its not overcharged, what can the reason?
Sir apka institute hai?
Bhai मैंने fridge me gas dalwai hai जिसके baad commperser pipe per ice aa gayi hai जो थोड़ी देर बाद melt bhi ho jaati hai raat के time ice बहुत थी पर दिन में दो teen बार hi ice jami thi फिर भी commperser bahut garm hai
Fridge बंद होने पर fan bhi बंद हो जाता है kya? क्योंकि बीच मे fridge में light तो on but fridge बंद था
134a gess PRESHER
1 to 10psi
Hi gn what the name of that thing pls
my upper doesnt freeze only cools even after fixing
What is the disadvantage of having ice on this suction line?
Maybe cause of late ice making
Maybe Cause of Damage compressor pump.
Maybe cause of leakage of compressor body due to rust.
If suction line is freezing your in danger of pulling liquid refrigerant into the compressor, causing damage to it
My fridge is like this right now 😢😢what is the name off that thing need one 😢 tomorrow pls
My fridge suction line is at 2psi running pressure but the line is still frosted. What could be the cause? Thank you.
If there is R600, than it should be on zero psi or below than zero
@@racworld1365 It’s R134A. I was told for R134A, the suction line pressure should be 22 psi and I need to add more r134a. In your video, the pressure is 0-2psi. I am confused. Thank you.
@@jamesw4445your refrigerator is direct cool? Or frost free?
@@racworld1365 It’s frost free. It’s GE side by side GSH25JSRFSS 25 cu ft fridge. It has automatic defrost. I can hear fan inside freezer runs when the compressor runs.
U have never make mention on how to do it if the company have to be running or of
Sorry but you are actually allowing the fridge to suck in moisture by opening the suction side
Hii
My refrigerator suction line is mouture comming. what is a reason?
Its normal
Ice any se koi masla B hota hai ?
Yes
Low cooling
Bad for compressor pump
Cause of rust on compressor suction
Urdu bol le mera bhae
Subscribe Naeem Technical Tv
R134a ref running pressure should be 10 to 12 psi 😂