FOSSiBOT F2400 2048Wh UNBOXING

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ส.ค. 2024
  • Einfach nur ein Auspack Video

ความคิดเห็น • 5

  • @flyblue6632
    @flyblue6632 ปีที่แล้ว

    sadly in pass-through mode ground wire isn't passed through to the sockets. ecoflow had the same problem and all powerstations were recalled .... 😢

    • @D3vic3Controll3r
      @D3vic3Controll3r  ปีที่แล้ว

      Yes i checked it after reading your Comment and YES its true. But i think if you use it as Battery Mobile you will have anyway no ground. But i have also the Anker 757 and 767 both of them pass the ground to the sockets.
      So its sad for the Fossibot, but still i like it, because its much more comfortable as my last Vtoman which i had.

    • @flyblue6632
      @flyblue6632 ปีที่แล้ว

      @@D3vic3Controll3r for Fossibot it's just about the high risk of injuries... when used in USV and a washing machine or other machine with metal body is broken... the full current flows through your body to the real ground... and no safety breaker will stop here using the Fossibot... That's only happening in USV mode... But it means you easily can die here. No warnings in instructions. Nothing. That's why ecoflow recalled their powerstations

    • @D3vic3Controll3r
      @D3vic3Controll3r  ปีที่แล้ว

      Yes ! I see what you mean, it's very sad because a lot of people will use it like you sayed... I asked the seller (fossibot Store) if he knows what will be the solution for this Dangerous Problem.
      I collect some details and put it once in a Review.

    • @flyblue6632
      @flyblue6632 ปีที่แล้ว +1

      @@D3vic3Controll3r Thanks for the feedback, I will follow you 👍