Steel Design L2L| LSM | Bolted Connections| Double Shear Butt Joint| Packing plate| Numerical| Hindi

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ต.ค. 2024

ความคิดเห็น • 35

  • @ErGovindJha
    @ErGovindJha 3 ปีที่แล้ว +5

    Nice mam please continue bahut view aayega may BHI TH-cam channel chalta Hu mujhe Aapka ye video Acha laga

  • @palak6513
    @palak6513 3 ปีที่แล้ว +3

    My fav teacher ❤️ always rock ✌️✌️

  • @RahulGupta-fm6dn
    @RahulGupta-fm6dn ปีที่แล้ว +1

    Very helpful videos thanku mam

  • @ankitpuran655
    @ankitpuran655 ปีที่แล้ว +1

    Thank u v. much Ma'am!

  • @abhishekgupta3298
    @abhishekgupta3298 2 ปีที่แล้ว +1

    Doing good job. 👍 keep it

  • @himanshusingh-hj4sy
    @himanshusingh-hj4sy ปีที่แล้ว +2

    It was helpful,but as you took 4nos. Of bolt then 4nos. Of bolt should be provided on each side hence total no.of bolts is 8

  • @yadavakash3217
    @yadavakash3217 7 หลายเดือนก่อน

    Thanku so much,😊😊 got alot help😊😊😊

  • @dikeshverma1714
    @dikeshverma1714 ปีที่แล้ว +1

    Maill gyi mam vedio👍

  • @tvplaystore3186
    @tvplaystore3186 2 ปีที่แล้ว +1

    Mam 6 bolt kyu nhi aaye Apki last video bolted connection me Dimond bolt question me apke bolts 6 aaye the tab apne btaya tha ki hum bolts har plate per provide karte hai toh apne 12 bolt use kiye the

    • @tvplaystore3186
      @tvplaystore3186 2 ปีที่แล้ว

      Mam ka bat or puchni thi ki jab hum diamond bolting me An nikalte hai toh wo staggered critical section jaise lete waise kyu nhi lete

    • @civilengg.withakriti2556
      @civilengg.withakriti2556  2 ปีที่แล้ว +1

      You're right... It should be on both the plates

  • @amansharma0017
    @amansharma0017 2 ปีที่แล้ว

    Design a double cover butt joint to connect two plates , each 12 mm thick and 300mm wide . the service load to be transfered is 200kn
    what to do in this question can you please explain asap

  • @augustyabhudev6595
    @augustyabhudev6595 2 ปีที่แล้ว +1

    mam is question mai tension of the main plate calculate kyu nahe ki hai?

    • @civilengg.withakriti2556
      @civilengg.withakriti2556  2 ปีที่แล้ว

      You can check the tension as well. Here, the concept of only the design of bolts is being discussed

  • @preenapraveen3798
    @preenapraveen3798 2 ปีที่แล้ว

    Mam if the thickness of cover plate is not given in the question then should we have to assume it ?

    • @civilengg.withakriti2556
      @civilengg.withakriti2556  2 ปีที่แล้ว +1

      Yes you will have assume the missing data and mention the assumptions in your answer sheet.

    • @imposter709
      @imposter709 2 ปีที่แล้ว +1

      @@civilengg.withakriti2556 Maam what should we assume the thickness of cover plate if it is not given, I'm asking in terms of numbers

  • @mehakashraf2134
    @mehakashraf2134 3 ปีที่แล้ว +1

    Mam can u please upload eccentric connections

  • @SavitaJk-o4s
    @SavitaJk-o4s 3 หลายเดือนก่อน

    Tqqqqqsmmm didi❤

  • @mathsconceptspashto8959
    @mathsconceptspashto8959 3 ปีที่แล้ว +3

    🤗❤

  • @rahulpandeypandey6666
    @rahulpandeypandey6666 2 ปีที่แล้ว

    Bolt dono side me 3-3 provide hoga drawing me.

    • @civilengg.withakriti2556
      @civilengg.withakriti2556  2 ปีที่แล้ว +1

      If the number of bolts have not been mentioned in the question we can provide any suitable number of bolts (here 3) in the drawing.
      However, in practice the joint is designed and bolts are provided according to that.

    • @exploringarts4152
      @exploringarts4152 2 ปีที่แล้ว +1

      Exactly there will be total 6 bolts provided

    • @sumitwrd
      @sumitwrd ปีที่แล้ว +1

      @@civilengg.withakriti2556 Mam ,how many bolts to be provided in this question? please explain.