Offset Columns / Eccentric Footing / Strap Footing

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ธ.ค. 2024

ความคิดเห็น • 37

  • @omaral-azzawi
    @omaral-azzawi 9 หลายเดือนก่อน

    I was in dire need of this video today. Thank youuuu so much Gabriel ❤

  • @shaxboznurmatov4448
    @shaxboznurmatov4448 2 ปีที่แล้ว +1

    Just awesome, please share the names of all soft wears used in video

  • @ehinspections
    @ehinspections ปีที่แล้ว

    Thank you for sharing, great video!

  • @Zorot99
    @Zorot99 ปีที่แล้ว

    Can we prevent the rotation of the pad footing if the we were to place these ground beams at the top surface of the pad? Not from the base

    • @bengthebrazilianengineerinAus
      @bengthebrazilianengineerinAus  ปีที่แล้ว

      you mean like a stepping the beam into the pad?

    • @Zorot99
      @Zorot99 ปีที่แล้ว

      @@bengthebrazilianengineerinAus not into the pad, into the column right above the pad.

    • @bengthebrazilianengineerinAus
      @bengthebrazilianengineerinAus  ปีที่แล้ว

      @@Zorot99 if the loads are still going to the pad and there's nothing preventing it from rotating it won't work. You better off landing the column on the beam, shifting the pad from the boundary and making it a concentric pad footing without bending moment.

  • @sothattheng8624
    @sothattheng8624 2 ปีที่แล้ว +1

    Thanks for yor sharing!

  • @calvoh9715
    @calvoh9715 2 หลายเดือนก่อน

    how about a concrete haunch from the column to the top of the base?

  • @twigsfloat2773
    @twigsfloat2773 ปีที่แล้ว

    Very helpful, thank you!

  • @sarangsahu9432
    @sarangsahu9432 8 หลายเดือนก่อน

    I have to design a structure where plot size is 20' wide only and all the column are at the property line so I am going for strap footing, but to analyse and design the strap footing where both the column is eccentric I tried to search any design example but couldn't find one. So if you suggest me any book or example that would be great. Thanks in advance 🙌🙌

    • @sarangsahu9432
      @sarangsahu9432 8 หลายเดือนก่อน

      You explained the concept very well.. thank you for this also 😊😊

  • @samuelkhongsai7180
    @samuelkhongsai7180 2 ปีที่แล้ว +1

    Why the pillar in one of the footing is at the middle while the footing in the opposite pillar is at the corner

  • @sheikhsadi8605
    @sheikhsadi8605 2 ปีที่แล้ว

    what is the softwear you useing for SFD and BMD ? Grate video

  • @ikemefulewisdom4791
    @ikemefulewisdom4791 4 หลายเดือนก่อน

    WHAT IS NAME OF THIS APP

  • @sergioramirez6897
    @sergioramirez6897 ปีที่แล้ว

    Question...if a building is sandwiched between two buildings and both column A and B bump up against property lines and hence both are eccentric footings. We still need a strap footing, but how does the cals change?

    • @bengthebrazilianengineerinAus
      @bengthebrazilianengineerinAus  ปีที่แล้ว +1

      Calcs are the same. Just draw the free body diagram with cantilever on both sides. Make sure there's no uplift

  • @praveens1801
    @praveens1801 2 ปีที่แล้ว

    How do design of beam ?

  • @donarobbo
    @donarobbo 2 ปีที่แล้ว

    Thank you!

  • @INAMmathematicivilengineering
    @INAMmathematicivilengineering ปีที่แล้ว

    Which app are you using?
    Suggest me an app like this for civil engineering video in Android phone

  • @shaxboznurmatov4448
    @shaxboznurmatov4448 2 ปีที่แล้ว

    thank you a lot

  • @susanpinzonsierra3525
    @susanpinzonsierra3525 2 ปีที่แล้ว

    Obrigado!!

  • @andrewk8966
    @andrewk8966 ปีที่แล้ว

    It wouldn't work like you described (for footings example) - like beam with two fixed basis...idea is good, but it's wrong. Cantilever is more closely. But the most closely will be "beam on ground".