Foundation Design Example with Offset Column and Eccentric Moments

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ก.ค. 2024
  • I go through a foundation design example with an offset column that induces eccentric moments.
    #foundationdesign #structuralengineering #geotechnicalengineering
    Show your support or if you want mentoring:
    / everydaydazz
    I create a lot of my videos, engineer sketches and notes on my iPad and if you own an iPad and are looking for a matt screen protector, I have been using Paperlike screen protectors for 3 years now and they are really good. Feel free to check it out - paperlike.com/everydaydazz
    -----------------------
    Purchases made from store links may give me some money.
    (It doesn’t cost you extra, so please buy everything)
    Structural Engineering Books I recommend:
    Structural Engineer’s Pocket Book - amzn.to/3no7taL
    Reinforced Concrete Design to EC2 - amzn.to/2Xlx75C
    Steel Designers Manual - amzn.to/2JS4bik
    Design of Structural Elements - amzn.to/2LvCMmI
    Gear I Use:
    M1 Mac mini - amzn.to/3tqijkM
    Apple wireless keyboard - amzn.to/3aqPGLI
    iPad Pro - amzn.to/3mMGMMT
    Magic Keyboard for iPad - amzn.to/355GoDd
    Airpods Pro - amzn.to/38MIFEn
    Tonor Mic - amzn.to/3mGRxA1
    Rode VideoMicro - amzn.to/3sMDYTm
    Go Pro Hero 7 - amzn.to/2Ji6bAj
    San Disk SD Card - amzn.to/37SwztP
    San Disk SSD 1TB - amzn.to/37FRWOr

ความคิดเห็น • 54

  • @mhdin787
    @mhdin787 2 ปีที่แล้ว

    hello there! just wanted to say thanks for doing this video. I'm a new engineer who just started working and has the exact problem in a project just like in this video. Thank you for teaching this, really helps me a lot !! cheers !!

  • @NA-oh2ck
    @NA-oh2ck 2 ปีที่แล้ว

    New to your channel and finding the content useful, thanks for taking the time to make it. Would be interested to see your method of assessmemt of an existing residential foundation relative to the effect of conversion works. For example, load bearing masonry wall removed and replaced with beam and posts and following through the effect to check suitability of existing found.

  • @OkeamuteIdolorUnscripted
    @OkeamuteIdolorUnscripted ปีที่แล้ว

    Great Explanation and walk through example!

  • @djsaarus6151
    @djsaarus6151 3 ปีที่แล้ว

    Excellent video Dazz! More please

  • @corytierney9318
    @corytierney9318 3 ปีที่แล้ว +2

    I think this style is perfect for better understanding the method. Would also be good to see how you formally produce in a calc pack also though. Keep up the good work 👍🏼thanks

    • @efy5aru
      @efy5aru 3 ปีที่แล้ว +1

      I was gonna say exactly the same thing... Great video Dazz

  • @structuralwork1879
    @structuralwork1879 3 ปีที่แล้ว

    Thanks for this video. It was really helpful

  • @86gautamp
    @86gautamp 2 ปีที่แล้ว

    Great Video. I am assuming that this foundation is at some depth(say 1.5m) from NGL. In some case when the load is not as high as this example and pad footing is to be rested on the ground and no Geotechnical data is available, how would you approach in the design?

  • @matsvanzelm7220
    @matsvanzelm7220 2 ปีที่แล้ว +5

    Hi there! I really like your channel! One thing you should always check: is your total soil pressure equal to your vertical load? (244 + 200) / 2 = 222 x 3 x 3 = 1998. Something is wrong, your minimal soil pressure. It should be 111 - 22 - 111 = -22. Mean soil pressure = 111. 111 x 3 x 3 = 999 ~ 1000. Normally a foundation can’t handle tension. So you should make a different calculation. Your eccentricity is 600 / 1000 = 0.6 m. The distance from the work line of your load to the edge of your slab = 1,5 - 0,6 = 0,9 m. The length of your triangle pressure figure is 3 x 0,9 = 2,7 m. Your max soil pressure is 2 x 1000 / (3 x 2,7) = 247 kN/m2.

    • @danielwen1002
      @danielwen1002 2 ปีที่แล้ว

      Agreed here. Thanks.

    • @Bobby14221234
      @Bobby14221234 ปีที่แล้ว

      there is nothing wrong with university text, but you are talking about an actual design, if you want, this is the most accuarate one, Pressure, P1 + (P1 - P2) (Lenght of direction in question, L + Width of column)/L = 266KN/m2

  • @LvPatriot1
    @LvPatriot1 3 ปีที่แล้ว

    Great, I really like your videos.

  • @williamtai89080
    @williamtai89080 2 หลายเดือนก่อน

    Should the additional moment due to shear and thickness of the foundation be added to the bearing stress check as well?

  • @paulclarke216
    @paulclarke216 3 ปีที่แล้ว

    Loving these videos man! Do you have any advice for someone like myself who has been out of the engineering game for a year and is about to jump straight back into a design engineering position? These videos are a great referesher I must say! Thanks

    • @EverydayDazz
      @EverydayDazz  3 ปีที่แล้ว

      Thanks! I’d say just get some practice in. You’ll pick it back up quite quickly I imagine.

  • @rabibrahman5990
    @rabibrahman5990 3 ปีที่แล้ว

    Love it man! I love how you put everything together for every kind of structural designs, as done by industry. Learning from practicing engineers definitely more valuable for the workforce, than learning from uni inexperienced academics.

  • @calvoh9715
    @calvoh9715 2 ปีที่แล้ว

    how did you get the shear force?

  • @robelgeremew8343
    @robelgeremew8343 2 หลายเดือนก่อน

    what is the software that your using to mark up

  • @maheshg5516
    @maheshg5516 2 หลายเดือนก่อน

    Thanks a lot 🙏

  • @mahmoudsamir4063
    @mahmoudsamir4063 หลายเดือนก่อน

    Hello there, a question regarding to your overturning check of the foundation why did not you add the additional moment due to eccentric load (column) you have calculated at the beginning of the video of 500 kN.m with the overturning moment ?

  • @venkatesh2285
    @venkatesh2285 9 หลายเดือนก่อน

    Could you do the similar type of example for us code

  • @adrianuslahiwu1002
    @adrianuslahiwu1002 ปีที่แล้ว

    What about allowable soil pressure Mr Dazz ?

  • @ibrahimjafaru6031
    @ibrahimjafaru6031 ปีที่แล้ว

    What foundation book can you recommend

  • @ravreyes11
    @ravreyes11 3 ปีที่แล้ว

    Can you do a design also using ACI code please?

  • @kameshtensigengg4658
    @kameshtensigengg4658 2 ปีที่แล้ว +1

    Moment on eccentric column will not act on centroid of the footing. So the MOI calculated is wrong...

  • @86gautamp
    @86gautamp 2 ปีที่แล้ว

    Do include some underground Pit design examples in your next Video 😀

  • @miguelimagina4322
    @miguelimagina4322 2 ปีที่แล้ว

    It would be very useful to show the reinforcement design of the foundation 👍

    • @EverydayDazz
      @EverydayDazz  2 ปีที่แล้ว +1

      Something I’m going to do in the future 🙂

  • @allanmanana1644
    @allanmanana1644 3 ปีที่แล้ว

    Great video, however I just have a simple question to ask, for the bearing pressure check, aren’t we supposed to check the calculated value vs the bearing capacity from the geotechnical report? (You didn’t include the bearing capacity) thanks.

    • @EverydayDazz
      @EverydayDazz  3 ปีที่แล้ว +1

      Yes you would check against the allowable bearing pressure from the geo report. I just skipped it 😅

    • @allanmanana1644
      @allanmanana1644 3 ปีที่แล้ว

      @@EverydayDazz okay then. So at 3:32 on your stress diagram, you indicated that the calculated values for the bearing pressure are 244kN/m2(highest) and 200kN/m2, my assumption is that the bearing capacity is greater than 244 in that case, what do you think 🤔? (Bearing capacity should bd greater than the bearing pressure)

    • @EverydayDazz
      @EverydayDazz  3 ปีที่แล้ว

      Yeah so if the allowable was greater than 244 than it passes. But if it’s less then you would need to re-size your pad to spread the stress

  • @aristotlesiron3303
    @aristotlesiron3303 2 ปีที่แล้ว

    are you using ACI CODE for the safety factor of 1.5 and reduction factor of 0.9?

  • @janasanjay1227
    @janasanjay1227 2 ปีที่แล้ว

    What would you do if footing width and length is limited sir

  • @biglolmaster
    @biglolmaster 2 ปีที่แล้ว +1

    Question: According you the moment generated by the excentricity isnt reversable, as so, whenever there's a compression load with excentricity and no moment at the foot, there's an constant increase in the bearing pressure.
    This doesnt feel correct! the pressure should vary and not be constant.
    can you please clarify me??

    • @EverydayDazz
      @EverydayDazz  2 ปีที่แล้ว

      If the column force is fixed in place then the eccentric moment generated is also fixed and doesn’t vary. So pressure cannot vary if the only moment generated is from eccentric axial loading.

    • @odera8289
      @odera8289 2 ปีที่แล้ว

      @@EverydayDazz shouldn’t there be more pressure closer to the eccentric column position compared to away from the column?

    • @odera8289
      @odera8289 2 ปีที่แล้ว

      th-cam.com/video/3OkkiFicH2Y/w-d-xo.html

    • @odera8289
      @odera8289 2 ปีที่แล้ว

      hi i have a question. will eccentricity caused by column offset from the centre lead to greater bending moment?

    • @odera8289
      @odera8289 2 ปีที่แล้ว

      th-cam.com/video/m_ITdRW-wYI/w-d-xo.html that’s a better eccentric pad foundation design

  • @TexasEngineer
    @TexasEngineer 2 ปีที่แล้ว

    Big question. What do you do if your method shows the soil in tension. This can happen when the loading is outside the kern. The S changes - to what? You did it another way, but you passed over the real reason for using 1.5.

    • @EverydayDazz
      @EverydayDazz  2 ปีที่แล้ว

      Do you mean when their is uplift? Soil can’t be in tension.
      If there is uplift then you need to make the foundation bigger to increase the self weight so that there is no more uplift.

    • @TexasEngineer
      @TexasEngineer 2 ปีที่แล้ว

      @@EverydayDazz That is my point. If you have tension in the soil, then the design does not work and the design is flawed. Stop and redesign. You did not check for tension. If you have the same problem using a tall steel pole with low axial load, high overturning, and low shear, you can see tension, which is not good because soil does not resist tension. If you have a situation with unsymetrical foundation or skewed lateral loads the problem is similar but more complex. A wind turbine foundation is somtimes octagonal.

    • @EverydayDazz
      @EverydayDazz  2 ปีที่แล้ว

      So I work out the stress on the soil and it’s all in compression, so that is the check to see if there is uplift.
      Also the overturning check is a check for uplift. Factor down the favourable forces and factor up the unfavourable forces.
      High shear is unfavourable because you take moments about the foundation.

    • @TexasEngineer
      @TexasEngineer 2 ปีที่แล้ว

      @@EverydayDazz To be quite honest, I don’t do these foundations by hand, I wrote an Excel spreadsheet with pictures and diagrams that would solve the problem and print the documentation. We also do not use the .9 on the weight for overturning; I wish I knew what code you are using. My perspective is from the electrical world (NESC) and the telecom world (EIA/TIA-222), not the building world. Bowels wrote a book that had very good examples of ths problem but it is very old.

  • @ICRPI
    @ICRPI 3 ปีที่แล้ว +1

    Would this "fag packet calculation" be sufficient for a building control submission or is it more for preliminary sizing or for Seniors to do a quick check?

    • @EverydayDazz
      @EverydayDazz  3 ปีที่แล้ว

      If you tidy up the calculation there’s no reason why you can’t use it for building regs.
      Definitely a great tool to use for preliminary sizing too since it’s so quick.

    • @ICRPI
      @ICRPI 3 ปีที่แล้ว

      @@EverydayDazz And by tidy up you mean copy and pasting the bearing pressure check, sliding check etc. in the correct sequence onto some calc paper?

    • @EverydayDazz
      @EverydayDazz  3 ปีที่แล้ว

      Yeah basically. Maybe use a ruler for the sketches too just to neaten everything. But essentially the calculation as I’ve shown is good enough for build regs.

    • @ICRPI
      @ICRPI 3 ปีที่แล้ว +1

      @@EverydayDazz Okay, good stuff. Thank you again!
      You're probs getting sick of me saying thank you but your content is top quality mate fairplay.