pang malalaking bahay po kasi yang explain ni sir kaya kong ano set up nio wag nio ng palitan kong maganda naman ung takbo ng solar nyo at kong wala naman problema
kong 170watts refrigerator lang naman pinapaandar mo tapos 3 fan lang coast of 35wattsx2=105watts,, no need that all requirements,, ac/dc metter, circuits breaker na 3 depende sa watts/voltage/current ng gamit mo,,kasi yan lang Naman gamit ko ngayun pero okay naman at walang problema, thank you sir sa video kasi pag may magpa2tau ng solar sa idea mo ako ku2ha idol thumbs up
Boss anong awg wire ang pwde setup ko na 24v 200ah. SSC to Battery na wire? Battery to Inverter na wire? Inverter AC out to Terminal (light, appliances at ref aircon)
ganyan pa din po ba ang safety requirements 2024? ang daming redundancy. asking lang po wala akong idea kung alin mas tama. may mga nakikita lang akong less ang protection setup pero di ko naman alam kung ok na yon.
Yes ka-Toolbox 2017 pa lang ang latest PEC natin as of now. Pwede naman hindi masunod yan pero yan ang pinaka-required ng ating Philippine Electrical Code.
From PV to Inverter lang ang pwedeng magamit para sa Grid-tied dito sa video natin boss. Ang output gaya lang din nung sa Building wiring CBs, etc boss.
Pa shout out idol...request ko sayo...pademo nmn paano ang set up sa solar pa.to charger to inverter at battery..ksama na po yung important na mga gamit lalo na breaker at fuse..pati na sa ground ..para magawa ko na yung skin na nabili ko...kakabili ko lng...
Sir, question lang po? Kc ang mga latest inverter ngayon may mga advance safety features na like over voltage protection, ground fault protection/ leakage current protection, impedance features, over current protection, SPD (MOV: Type III standard. Baka kc hindi mag match ang mga additonal breaking protection na ilalagay manually during installation sa built-in features ng isang inverter doon pa magka problema? Sapat na rin ba na mag rely tayo sa kung ano meron na safety standard features si inverter? Syempre alam natin na itong mga manual safety protection ay parte ng electrical code (PEC) standard.
Agree boss. Marami na talaga may mga protection na inverter at equipments ngayon. Pero need ko pa ng further info kung magc0nflict ba sila. Marami din kasing equipments na may built-in protection na hindi natin sure kung working ba talaga yung built-in protection nila.
You computed correction factors for higher ambient temperature in your wire sizing video. You adjusted ambient to a higher 40-45 degrees I think. Corrent me if i am wrong, are you not supposed to divide instead of multiply. Increased ambient temperature degrades the ampacity of the conductor right? And when you divide, the result will be a figure that will call for a bigger wire hence a higher ampere rating. But say coming from higher ambient temperature of say 38 degrees, if we want to adjust to a room temperature of say 30 degrees, thats the time you multiply. This will result for a conductor that will have a lower ampere rating. Just looking for clarification.
Master meron lng po tanung meron akon 100 solar panel 30A na solar charger 65 ah 12 battery 1000w power inverter anu po kya gagamitin kung DC/AC breaker po jan
sir saan po kaya sa PEC yung nagsasabi na kailangan i-multiply nang 125% due to over irradiance yung ISC ng PV ? overall lods sobrang ganda ng tutorial mo.
Thank you po. Try ko search maya pag-uwi. Pero sa natandaan ko base yan sa recommendations ng mga PV manufacturers. At base sa na-experience ko din ay nangyayari talaga.
master kung bibili kami nang 24v hybrid inverter powerwall na my ground wire protection at lahat ng wire na papunta sa hybrid inverter na may circuit braker safe naba ito kasi nag titibid kase ako
Pwede na 20A-30A kung gagamitin mo sa Outlets. At 10A-20A para sa Lightings. Pero kung masyadong mababa talaga ang total drawn current ng bawat ciruit na susuplayan, ay mas maganda yung mas mababa pa dyan boss.
Ang solar panel po natin boss ay kayang magproduce ng more or less 4,200W per day. Ang battery, kailangan ng 4,800W. Pero may paraan dyan. Ang load natin within 24 hrs ay aabot sa 12,000Watts. Short po talaga. Pero baka hindi laging naka-ON ang mga unit gaya ng Ref. ON/OFF kasi ang operation nyan sa loob ng 24 hrs, baka may ganyan boss.
2pcs ilaw,pldt modem, mikrotik router, 1pcs access point para sa wifi, fiber switch, vendo machine, sa ganito boss ano solar setup specs gamitin ko boss..priority ko is pisowifi na mga gamit ..hindi aabot nga 8hrs ang backup time ..kong kaya sa budget isa ko 1unit freezer
Pwede ko b itap sa grounding rod ko n nakakabit sa meter ng meralco sir? Un po kc sure n malalim hehe. Ako po ngpakabit ng grounding rod nun nung ngapply ako ng meter sa meralco
boss sa AC system po, di ba line to line yung voltage natin sa residential from meralco, pwede po ba gumamit ng SPD kahit Line and neutral (2Pole) kahit line to line ang source?
sir may 12v system ako na lithium iron phospate..maliit lang ang system ko kaya pwm ang gamit ko..may 12v tv ako na nka connect sa pwm. Ngunit nung biglang nag balance ang battery pack ko biglang nag error ang pwm ko tumaas ang voltage bigla kaya nasira ang tv ko. Tanong ko lang anong dapat na protection device gagamitin ko para maiwasan ang biglang pag taas ng voltage sa pwm pra ma protect ang load ko?
No problem boss. Actually, Mas ok yang fuse in terms of tripping/Cut off dahil fast acting yan kaysa sa CB. Yun nga lang ay palit ka ng palit kapag may fault.
May nabibili pong grounding clamp para sa Panel boss. Maliit lang yun, at doon niyo i-tap ang wire at yung clamp ay i-mount nyo sa Aluminum frame ng Solar Panel.
Kung s breaker ay mas malaki Ang amperes Ang gamitin ay ok lng po ba, example ay 20A, tpos ay kunin nalng mas mataas like 40A. Paki sagot po please, balak ko mg DYI
@@ELECTRICALTOOLBOXPH I think the fuse has a faster response than the circuit breaker, but I'm not sure if that makes a difference to the batteries/pv module?
Boss Tanong ko lang puwede ba e charge ni inverter c battery bank kahit nakabaliktad n iyong takbo Ng current nya s MCB Diba Kasi iyong design nya battery to inverter din PG ngcharge Tayo inverter to battery nman.,.d ba maccra iyong MCB KC pabalik ung current papuntang battery bank for charging porpoises ongrid set up ko Po.
Boss paano naman elijoy gamit ko 400W paano ang pagkuha ng current ? para makuha ang size ng wiring at dc breaker. 400W elijoy need ko dc breaker at wire size. thanks Boss
Hello sir, halimbawa po merong akong 4pcs solar panels na 300W kada isa at naka parallel connection. 19.05A po ang Isc ng bawat isang panel. Tama po ba ang computation ko ng circuit breaker na 19.05A x 4panels equals 76.2A. Then, 76.2A x 1.25 x 1.25 = 119.06A. Kaya ang DC CB na ilalagay ko ay 120A, tama po ba? Salamat po
Example, ung sa 550watts panel 5 nakaseries. Ang ISC ay 14.02 x1.25x1.25= 21.9A. So ang gagamitin na DC CB ay 20A? Hindi ung 25A o 16A na breaker. Mayroon na kasi akong existing na16A Dc breaker. Nag aalanganin kung bibili ulit ng bagong 20A o 25A na DC breaker.
boss bakit kaya nainit dc mcb sa 3 panel na 550watts na nkaseries to hybrid inverter ko na 25A, ok naman connection, pnaltan ko 40A ganon pdin, nainit padin.salamat
Sir patulong naman po newbie lang ito po set up ko 2 100w & 1 150w na pv naka series po yan ang gamit ko po na pv cable 4mm2, 40a po na mppt gamit ko controller, 1kw snadi inverter, 2 100ah battery, nka 12v system po ako, ang gamit ko Wire sa system 8awg, ilang amperes po dapat ang breaker ko? 16a lng kasi gamit ko na cb from pv to scc, tska 32a na cb from scc to battery, sana po masagot Tia!
Iba2 ang size ng CB at iba pang protection devices boss, depende sa location at situation ng bawat setup. Try nyo dito boss.. th-cam.com/video/w0SmtIUu4bo/w-d-xo.html
master, kung parallel ang set ng pv mag a add ba ang ISC? lets say dalawang 400w na may isc na 10.36 each pv, x2 din ba ang computation nito? magiging 10.36x2 ba sya? then saka multiply sa 1.25x1.25? tama po ba? maraming salamat po sa tugon ninyo master.
Kung 200W, 100Ah ang battery dyan kung 12V system ka. Battery Sizing: th-cam.com/video/p4aHzZr9bIY/w-d-xo.html Solar Panel Sizing: th-cam.com/video/9ILSUlOlFzM/w-d-xo.html
Suggestion lng po pra mas gumanda pa lalo content mo sir . Mag invest po kayo sa magandang microphone di ko pokasi kayo marinig masyado parang bumubulong lng po kayo..
You are the best so far for detailed illustration
Thank you so much. I really appreciate it.
pang malalaking bahay po kasi yang explain ni sir kaya kong ano set up nio wag nio ng palitan kong maganda naman ung takbo ng solar nyo at kong wala naman problema
Thank you po.
YOUR ENGLISH TRANSLATION BLOCKS THE POWER POINT!
Baka possible ang pag-turn OFF ng Subtitle boss.
kong 170watts refrigerator lang naman pinapaandar mo tapos 3 fan lang coast of 35wattsx2=105watts,, no need that all requirements,, ac/dc metter, circuits breaker na 3 depende sa watts/voltage/current ng gamit mo,,kasi yan lang Naman gamit ko ngayun pero okay naman at walang problema,
thank you sir sa video kasi pag may magpa2tau ng solar sa idea mo ako ku2ha idol thumbs up
Bagong kadikit sa very informative video mo. Dami kung natutunan. Sana masuklian po Lodz
Gudpm lahat ng mga add mo diko inescape boss kc ang galing mo mag explain
Maraming salamat boss! Welcome sa Electrical Toolbox family.
great presentation. thanks, it is so informative.
Glad it was helpful! Thank you.
Boss anong awg wire ang pwde setup ko na 24v 200ah.
SSC to Battery na wire?
Battery to Inverter na wire?
Inverter AC out to Terminal (light, appliances at ref aircon)
Ok sir salamat, kompleto. rekado
Welcome boss.
Sana sir gumawa din kayo for 12v wind turbine complete guide setup.
Keep it up sir, very informative more video in the future
Thank you boss! Yes! marami pa ang isi-share nating tips and guides.
Well explained kapatid..God bless..Shout out
Thank you boss. Much appreciated!
Galing, dami ko natutunan. Salamat master
Welcome bossing! Maraming salamat sa magandang feedback.
Sana meron din solar pump for agriculture
ganyan pa din po ba ang safety requirements 2024? ang daming redundancy. asking lang po wala akong idea kung alin mas tama. may mga nakikita lang akong less ang protection setup pero di ko naman alam kung ok na yon.
Yes ka-Toolbox 2017 pa lang ang latest PEC natin as of now. Pwede naman hindi masunod yan pero yan ang pinaka-required ng ating Philippine Electrical Code.
16mm2 ang pinakamalaking wire sa system ko so 16mm2 din ang grounding wire sir? 6mm2 lang kasi gamit ko sa dc spd diko pa naparallel ang ac spd
Boss pwede ba na isa lng ang ground rod para sa ac spd at dc spd? Tnx po
Sa 600w gridtie setup need din po b yan ganyan protection like spd or breaker lng sa input at output?
Yes po.
Sir Good day. Ilan ampere po kailagan sa AC SPD 8KW GRID TIE
Meron ka po safety devices for grid tie setup?
From PV to Inverter lang ang pwedeng magamit para sa Grid-tied dito sa video natin boss. Ang output gaya lang din nung sa Building wiring CBs, etc boss.
Ano size number wire gamitin?? Ano SPD?? Mayron pa sa online??
Sir among size ba Ng grounding wire ang kailangan sa Solar Panel?
Pa shout out idol...request ko sayo...pademo nmn paano ang set up sa solar pa.to charger to inverter at battery..ksama na po yung important na mga gamit lalo na breaker at fuse..pati na sa ground ..para magawa ko na yung skin na nabili ko...kakabili ko lng...
Click nyo po ito sir:
th-cam.com/play/PL_nxTvHt0aMQ5_lt0wepN91_5AeLgzPq9.html
Nandito na po ang pagsizing ng lahat ng parts sa Off-grid.
Sir, question lang po? Kc ang mga latest inverter ngayon may mga advance safety features na like over voltage protection, ground fault protection/ leakage current protection, impedance features, over current protection, SPD (MOV: Type III standard. Baka kc hindi mag match ang mga additonal breaking protection na ilalagay manually during installation sa built-in features ng isang inverter doon pa magka problema? Sapat na rin ba na mag rely tayo sa kung ano meron na safety standard features si inverter? Syempre alam natin na itong mga manual safety protection ay parte ng electrical code (PEC) standard.
Agree boss.
Marami na talaga may mga protection na inverter at equipments ngayon. Pero need ko pa ng further info kung magc0nflict ba sila.
Marami din kasing equipments na may built-in protection na hindi natin sure kung working ba talaga yung built-in protection nila.
sir about grounding,,,ok ba pagsamahin ang mga grounding ng dc at ac sa isang grounding rod?
Yes boss. As much as possible, 1 ground lang dapat to avoid potential difference between the grounding Electrodes.
@@ELECTRICALTOOLBOXPH salamat sir.new subscriber here !!!!
Welcome to the Electrical Toolbox family boss!
@@ELECTRICALTOOLBOXPH sir my grounding rod nko nakconnect sa meralco meter ko pwede konaba dun itap ung grounding wire or need separate na rod?
Sir pwede ba iconnect grounding wire nung spd sa ground rod nung solar panel ? Para isahang ground rod lang. Thank you
Mas maganda yan boss. Mas maganda 1 grounding lang.
Mas maganda yan boss. Mas maganda 1 grounding lang.
Yung ground wire ba ng inverter niyo tas ground wire ng solar panel at spd papunta sa isang ground rod lang or tig iisa sila ng rod?
Mas maganda iisa lang boss. To avoid potential between the other grounding electrode.
You computed correction factors for higher ambient temperature in your wire sizing video. You adjusted ambient to a higher 40-45 degrees I think. Corrent me if i am wrong, are you not supposed to divide instead of multiply. Increased ambient temperature degrades the ampacity of the conductor right? And when you divide, the result will be a figure that will call for a bigger wire hence a higher ampere rating. But say coming from higher ambient temperature of say 38 degrees, if we want to adjust to a room temperature of say 30 degrees, thats the time you multiply. This will result for a conductor that will have a lower ampere rating. Just looking for clarification.
Ok sir.
Dividing numbers in decimal point will give a higher result:
Example:
100 x 0.5 = 50 (Small result)
But,
100 / 0.5 = 200 (Higher result)
Master meron lng po tanung meron akon 100 solar panel 30A na solar charger 65 ah 12 battery 1000w power inverter anu po kya gagamitin kung DC/AC breaker po jan
sir saan po kaya sa PEC yung nagsasabi na kailangan i-multiply nang 125% due to over irradiance yung ISC ng PV ? overall lods sobrang ganda ng tutorial mo.
Thank you po. Try ko search maya pag-uwi. Pero sa natandaan ko base yan sa recommendations ng mga PV manufacturers. At base sa na-experience ko din ay nangyayari talaga.
master kung bibili kami nang 24v hybrid inverter powerwall na my ground wire protection at lahat ng wire na papunta sa hybrid inverter na may circuit braker safe naba ito kasi nag titibid kase ako
Pwede na yan boss. Pero kung gusto mo ng additional protection, pwede rin gawan.
Sir tanung lang po if pwede ac breaker ang gamitin from inverter,?
Kung sa output ng Inverter boss, ok na yan. Dapat AC na.
Sir okay lng puba ang 16a DC breaker ko sa 160watts na panel? At 16a sa 12v battery?
Depende yun sa Ambient Temperature po.
Sir kng mag lalagay ako Ng ac breaker sa out Ng inverter na 1kw ILang amps Ang breaker ko na ilalagay?
Pwede na 20A-30A kung gagamitin mo sa Outlets.
At 10A-20A para sa Lightings.
Pero kung masyadong mababa talaga ang total drawn current ng bawat ciruit na susuplayan, ay mas maganda yung mas mababa pa dyan boss.
Sir ask po sa 300x4 na panel
At 200ah geltype 4pcs 48v setup
Load sa inverter 500watts kaya puba 24hours
Ang solar panel po natin boss ay kayang magproduce ng more or less 4,200W per day.
Ang battery, kailangan ng 4,800W. Pero may paraan dyan.
Ang load natin within 24 hrs ay aabot sa 12,000Watts. Short po talaga.
Pero baka hindi laging naka-ON ang mga unit gaya ng Ref. ON/OFF kasi ang operation nyan sa loob ng 24 hrs, baka may ganyan boss.
Bossing kpag size 14 po ang size ng wire anu po kaya ang breaker na kailangan..
Siguro ang available ngayon sa market para sa AWG 14 ay 16A.
2pcs ilaw,pldt modem, mikrotik router, 1pcs access point para sa wifi, fiber switch, vendo machine, sa ganito boss ano solar setup specs gamitin ko boss..priority ko is pisowifi na mga gamit ..hindi aabot nga 8hrs ang backup time ..kong kaya sa budget isa ko 1unit freezer
Need nyo po muna malaman ang wattage ng bawat load ka-Toolbox.
Ito ka-Toolbox for small loads. Sundan mo ito for additional idea. th-cam.com/video/gy72YPJMorw/w-d-xo.html
Paanu po mag wire NG DC and ac isolator switch? Sana po matulungan ninyo ako
Gaya lang ng pagwire ng circuit breaker boss.
Boss ok lng b 100a Ang gamitin na circuit breaker kysa 80a Kasi 86.4 ung compute mu bumaba.,.ung sa battery to inverter Po.
Masyadong mataas yan boss. Mahaba po ba ang wire ninyo from inverter to battery po?
@@ELECTRICALTOOLBOXPH NASA 3ft lang Po boss para Hindi maapektuhan ung wire size gauge4 Po ga2mitin q n wire.
Ok po. Pero mas ok na hindi mataas ang CB rating po para safe talaga ang wires nyo po.
@@ELECTRICALTOOLBOXPH ok Po Thank you boss.
Thank you
Welcome po...
Sir ung grounding wire ng dc spd at ac spd pwede naba pagsamahin sa isang busbar tapos connected to pv ground wire gang grounding rod?
Yes boss. Mas maganda yung pinagsama sila para iwas sa potential difference between two or more Grounding Rod (Electrodes).
Pwede ko b itap sa grounding rod ko n nakakabit sa meter ng meralco sir? Un po kc sure n malalim hehe. Ako po ngpakabit ng grounding rod nun nung ngapply ako ng meter sa meralco
Yes po. Pwede yun boss. Make sure na tight ang mga bonding.
@@ELECTRICALTOOLBOXPH maraming salamat uli idol more power anf more videos to cone hehe
Welcome boss. Maraming salamat din po.
grabe ung requirements ng conductor wire, pano pag battery cable 35mm2, so that 35mm2 or higher ung grounding cable? :O
Sa actual boss depende na sa installer. Pero kung Code kailangan talaga minimum allowable.
boss sa AC system po, di ba line to line yung voltage natin sa residential from meralco, pwede po ba gumamit ng SPD kahit Line and neutral (2Pole) kahit line to line ang source?
Yes po. Walang problema yan boss.
sir may 12v system ako na lithium iron phospate..maliit lang ang system ko kaya pwm ang gamit ko..may 12v tv ako na nka connect sa pwm. Ngunit nung biglang nag balance ang battery pack ko biglang nag error ang pwm ko tumaas ang voltage bigla kaya nasira ang tv ko. Tanong ko lang anong dapat na protection device gagamitin ko para maiwasan ang biglang pag taas ng voltage sa pwm pra ma protect ang load ko?
Pwede pla pwm sa lithium? kala ko pang lead acid lng at gel Ang pwm...
Pwede ka gumamit ng LVD HVD cut-off relay module boss.
Yes pwede boss. Gamit ko yung green na nasa 300 plus ang presyo.
sir ok lang ba na fuse na gamit ng motor ang ginawa ko temporary na protection device sa pwm,?
No problem boss. Actually, Mas ok yang fuse in terms of tripping/Cut off dahil fast acting yan kaysa sa CB. Yun nga lang ay palit ka ng palit kapag may fault.
meron po ba kayong Drawing or Patter na pwede naming Masundan sa Pag set up ng Off Grid tnx po
Yes po. Dito po.
th-cam.com/video/MKyWvWfFhz8/w-d-xo.html
Pano po magkabit ng grounding wire sa solar panel?
May nabibili pong grounding clamp para sa Panel boss. Maliit lang yun, at doon niyo i-tap ang wire at yung clamp ay i-mount nyo sa Aluminum frame ng Solar Panel.
Pano niyo po na calculate yung battery to inverter circuit breaker?
Nandito boss.
th-cam.com/video/xPyTeT_dFr0/w-d-xo.html
sir dc circuit breaker ung sa battery to inverter tama po ba? thank u
Yes po.
Selamat Thank you
You're welcome!
Hello sir magtatanong lang po ako kung paano yung sizing ng AC SPD
Same concept sa DC SPD boss pero AC Voltage at Current ang iko-consider.
@@ELECTRICALTOOLBOXPH yung max. output voltage po ba ang gagamitin sir?
@@jackapigo2383 Yes boss. Base mo sa output voltage ng Inveter.
@@ELECTRICALTOOLBOXPH Thankyou so much boss. Its a big help .
Welcome boss!
Kung s breaker ay mas malaki Ang amperes Ang gamitin ay ok lng po ba, example ay 20A, tpos ay kunin nalng mas mataas like 40A.
Paki sagot po please, balak ko mg DYI
Mas maganda po mas mababa.
Good morning sir. New follower nyo po ako, plano ko sir magset up ng hybrid off grid inverter. Kailangan ko parin po ba ng mga protection. Thanksnpo
Yes po. Kailangan pa din boss.
Hi, is this dc circuit breaker enough to protect Lifepo4 batteries/PV string or should it be combined with fuses?
Yes boss. But if there is a chance to add up another protection, much better to add those devices.
@@ELECTRICALTOOLBOXPH ОК! Thanks a lot!
@@ELECTRICALTOOLBOXPH I think the fuse has a faster response than the circuit breaker, but I'm not sure if that makes a difference to the batteries/pv module?
san makabili ng AFDD for DC
Boss Tanong ko lang puwede ba e charge ni inverter c battery bank kahit nakabaliktad n iyong takbo Ng current nya s MCB Diba Kasi iyong design nya battery to inverter din PG ngcharge Tayo inverter to battery nman.,.d ba maccra iyong MCB KC pabalik ung current papuntang battery bank for charging porpoises ongrid set up ko Po.
Commonly sa mga MCB ay naka-pwede naman po. Maliban nalang po siguro doon sa special designs.
@@ELECTRICALTOOLBOXPH ok thank you Po boss
Sir saan nakakabili ng dc spd na 48v at ground fault at arc fault protection dito sa pinas. matagal na akong naghahanap wala akong makita dito
Try nyo hanapin sa FB boss, One-point System at Hanem Solar.
Sir, anung system po yang vedio presentation nyo? 12volt or 24volts?
12V System po.
Boss okay lang ba na isa lang ang spd sa lahat ng connection
Sa DC side po ba?
Boss paano naman elijoy gamit ko 400W paano ang pagkuha ng current ? para makuha ang size ng wiring at dc breaker. 400W elijoy need ko dc breaker at wire size. thanks Boss
Ano ang system voltage na gamit nyo po? 12V o 24v?
@@ELECTRICALTOOLBOXPH 12V system lang boss
Kung 400W anv Panel boss nasa 25 to 27Amps yan..
@@ELECTRICALTOOLBOXPH 25A dc breaker for safety. Wire size naman Bossing Mppt to Battery Bank. Salamat
Bossing tanong ko lng about sa DC SPD. 24v Kasi ung set up ko sa solar ko. 24v din ba Ang ilalagay ko na DC SPD?thanks
Pinaka-minimum na value ang 24V boss. Kaso walang available na 24V SPD sa atin. Pwede na dyan higher na available.
Ano Kaya magandang ilagay bossing? 500vdc at 1000vdc Kasi ung nakikita ko sa online. Ok lng ba ung 500vdc boss? thanks
Ok na yang 500V boss.
@@ELECTRICALTOOLBOXPH t.y bossing
isang ground rod lang ba ang gagamitin okay na?
Mas mainam na isa lang boss para maiwasan ang potential difference sa pagitan ng dalawang Ground Rod.
Master tanong ko lng hindi mag charge yng charger inverter ko 5kva-par-b
Naka-Set na po ba sa mode 1 boss?
Hello sir, halimbawa po merong akong 4pcs solar panels na 300W kada isa at naka parallel connection. 19.05A po ang Isc ng bawat isang panel. Tama po ba ang computation ko ng circuit breaker na 19.05A x 4panels equals 76.2A. Then, 76.2A x 1.25 x 1.25 = 119.06A. Kaya ang DC CB na ilalagay ko ay 120A, tama po ba? Salamat po
Yes po. Pero kailangan mas mababa ang CB rating mo kaysa sa wire ampacity. Gaya nito, itong 119A ay minimum para sa size ng wire.
So ang magandang DC Circuit breaker po ay 100A sa 119A. Hindi yung 120A DC breaker para matrip pag mag over current. Tama po ba?
Yes po. Mas mababang rating ng CB mas ok as long as hindi siya palaging nagtitrip.
Example, ung sa 550watts panel 5 nakaseries. Ang ISC ay 14.02 x1.25x1.25= 21.9A. So ang gagamitin na DC CB ay 20A?
Hindi ung 25A o 16A na breaker.
Mayroon na kasi akong existing na16A Dc breaker. Nag aalanganin kung bibili ulit ng bagong 20A o 25A na DC breaker.
Yes po. Kung hindi naman laging nagtitrip ang 20A CB po.
Gawa kayo ng complete calculation gamit ang hybrid inverter Sir. Salamat
Thank you sa suggestion boss! noted po.
By the way, ang video natin ay applicable sa Standard Hybrid System.
Yes tama sir. Salamat sa mga info mo
boss bakit kaya nainit dc mcb sa 3 panel na 550watts na nkaseries to hybrid inverter ko na 25A, ok naman connection, pnaltan ko 40A ganon pdin, nainit padin.salamat
Ano po Isc ng 550W ninyo?
11.29amps boss.
Mababa naman yan boss. Baka kulang lang sa higpit.
aus nman boss ang pagkakahigpit eh.
Sa may terminal po ba ang umiinit?
hi sir..
tanong sir..may mai'susuggest ka ba na device or unit na magdisconnect ng battery automatically..? salamat sir.
Magdisconnect incase anong situation boss?
Kung magdisconnect paglow voltage, meron sa Lazada nyan boss.
Sir patulong naman po newbie lang ito po set up ko 2 100w & 1 150w na pv naka series po yan ang gamit ko po na pv cable 4mm2, 40a po na mppt gamit ko controller, 1kw snadi inverter, 2 100ah battery, nka 12v system po ako, ang gamit ko Wire sa system 8awg, ilang amperes po dapat ang breaker ko? 16a lng kasi gamit ko na cb from pv to scc, tska 32a na cb from scc to battery, sana po masagot Tia!
Iba2 ang size ng CB at iba pang protection devices boss, depende sa location at situation ng bawat setup.
Try nyo dito boss..
th-cam.com/video/w0SmtIUu4bo/w-d-xo.html
Gnda master tagasaan p0 kau s penas
Davao Region boss.
master, kung parallel ang set ng pv mag a add ba ang ISC? lets say dalawang 400w na may isc na 10.36 each pv, x2 din ba ang computation nito? magiging 10.36x2 ba sya? then saka multiply sa 1.25x1.25? tama po ba? maraming salamat po sa tugon ninyo master.
Yes boss. Saktong sakto yan.
thank sa video na 2
Yun example mo na 20amp at 25vdc spd and other device depende b yun sa solar panel?
Yes boss.
Kailangan talga ung spd boss??pwede ba ung circuit breaker lang?
Pwede naman hindi lagyan boss pero delikado sa kidlat ang SCC at iba pang naka-direct sa linya ng Solar Panel boss.
Saan po part kailangan lagyan ng circuit breaker??at anong circuit breaker gamitin?
Halimbawa po boss..200watts ano po kailangan na battery?
Kung 200W, 100Ah ang battery dyan kung 12V system ka.
Battery Sizing: th-cam.com/video/p4aHzZr9bIY/w-d-xo.html
Solar Panel Sizing:
th-cam.com/video/9ILSUlOlFzM/w-d-xo.html
Tama po ba, isang bus bars nlng na me 4 poles para sa lahat from Pv to scc to inverter, tas isang wire to ground rod.
Yes ka-Toolbox. Pwede yan.
@ELECTRICALTOOLBOXPH yun maraming salamat po ka toolbox🥰🥰🥰🥰🥰🥰godbless
pa shout out ya .. ☺️☺️☺️
No probs dai...
Idolllll!! 10star
Suggestion lng po pra mas gumanda pa lalo content mo sir . Mag invest po kayo sa magandang microphone di ko pokasi kayo marinig masyado parang bumubulong lng po kayo..
Thank you boss.
ini bahasa apa sih :(
but thanks for your presentation
T
ang daming breaker breaker hindi mo alam kung ano ikakabit mo
Ou nga boss. Pwede din naman fuse instead of CB.