Troubleshooting a Powermax 0-30 fault code

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ก.ย. 2024

ความคิดเห็น • 10

  • @pmd7914
    @pmd7914 3 ปีที่แล้ว +1

    Fellow Powermax45 XP users, be aware you may not get a numeric fault code if using hand held torch. If fault develops look at pages 150 of operator manual for flashing lights code meanings. If using with cnc computer screen may display the fault code.

  • @upendergupta5302
    @upendergupta5302 3 ปีที่แล้ว +1

    Please sir help me my machine torch is moving down in running time it touch in material sheet and stop machine plasma collision alarm

  • @EdwardJSamar
    @EdwardJSamar 4 ปีที่แล้ว +1

    Help me, I'm worried because I already checked all the consumables and the problem is still not solved

    • @hypertherm
      @hypertherm  3 ปีที่แล้ว

      Edward, I hope you were able to find the issue you were having and got that fixed. so sorry for missing this question.

  • @omarfarukh7318
    @omarfarukh7318 4 ปีที่แล้ว

    Good

  • @samisiddique5000
    @samisiddique5000 7 หลายเดือนก่อน

    Sir I have powermax105 sometime 0-30 error but two to three time on off its reset I already send to service but same problem until now we change new torch but problem still same any idea why

  • @francescobalbisboggiano7775
    @francescobalbisboggiano7775 3 ปีที่แล้ว

    I have a problem on hypertherm 125: the electrode hops and the air comes out intermittently. result when I start the arc it burns the electrode spring immediately. how should i solve? do i need a more powerful compressor? the flashlight is new

    • @hypertherm
      @hypertherm  3 ปีที่แล้ว

      Hi Fancesco, Thanks for reaching out with your comment. Can you verify that your compressor that is rated for 9.2 CFM at 90 PSI.?

  • @polykid101
    @polykid101 4 ปีที่แล้ว

    1:30 I think you have your swirl ring in backwards

  • @bobd.fletcherjr4912
    @bobd.fletcherjr4912 2 ปีที่แล้ว

    🇺🇸🇺🇸👍👍👍👍👍👍👍👍👍