آپ نے اچھی کوشش کی ہے لیکن ایک بات آپ بھول گئے کہ موٹر ، فرج یا ac وغیرہ آن ہوتا ہے اسٹارٹنگ لوڈ تقریبا 3 گنا زیادہ ہوتا ہے اس صورت میں سولر انورٹر موٹر آن نہیں کر پائے گا اس سے بچنے کے لئے دگنے سولر پینل لگانے ہوں گے
@@textilemachineryloversbyfarhan Dear Sir.kon si company ki moter achi hoti .or sir baz dafa onki winding copper ki nahi hoti yh kesay malom krain.original copper ki moter hai ya nahi .apka experience kia kehta hai .please guide us
Main ne summer Sible pump k Liye inverter lagana he or pump ka torque 22Amp he to or running 11amp to Kitne KW ka inverter lagaon, Please advise karen😊
@@textilemachineryloversbyfarhan ok bhai, mere 330w ke poly panels 4 saal puraane ho gaye hai. Panel ke peeche VOC 46.2V likhi hai. Maine 2 panel ki series banani hai to kya mai 90 VOC ka MPPT charge controller laga sakta hu? Abhi tak PWM charge controller lagaya hua tha.
Bhi 14soler 400w wale 5.5 hp ki submersable moter jo ke310 feet per fiting ha pani ka presor kam ha seting bhi thek ha lekin moter saey tareky se nahi chal rahi ol1 ka fault dety ha please renmany farmain ke hamarin platein kum to nahin hain
Bhai jan agr 1 ton ka inverter A.C chalana ho to kon sa inverter lagana pare ga or kitne solar panel lagain ge.. 220 ampere ki tubular battery bhi sath lgani hai.. Please guide
Dear koi b achi company ka 2 kw ka hybrid inverter use krain. 3 solar panel 585 watt ky lga lain. Battery k liay aap pehly btain back up kitny time ka chahey?
Single phase k liye calculation bilkul ghalat hai. Number 1. 4 solar sey tho invt on nahi hotha. Number 2. Mera motor 10 ampere le raha hai. 585 watt k 7 panal hai. Pir b full pressure sey pani nahi detha
good job
Thanks 👍👍
Zabardast. Achy tareqay se samjhaya.
Thanks for appreciate. Keep watching 👍
Mashallaha bhi jan good information
Thanks 👍
Great talent 💯💯💯✅✅🌹🌹
Thanks for appreciate. Keep watching 👍
Good work
Thanks 👍
Well DONE keep it up .May ALLAH BLESS YOU AND YOUR FAMILY
Thanks for appreciate. Keep watching 👍
آپ نے اچھی کوشش کی ہے لیکن ایک بات آپ بھول گئے کہ موٹر ، فرج یا ac وغیرہ آن ہوتا ہے اسٹارٹنگ لوڈ تقریبا 3 گنا زیادہ ہوتا ہے اس صورت میں سولر انورٹر موٹر آن نہیں کر پائے گا اس سے بچنے کے لئے دگنے سولر پینل لگانے ہوں گے
Dear by vfd you can control starting torque with the setting of Acceleration time. Thanks for your good opinion.
بڑے بہترین انداز سے سمجھایا ہںے
Excellent ❤❤❤
Very nice and good work Brother
Thanks 👍
زبردست
Thanks 👍
❤❤❤❤❤
Thanks 👍
@@textilemachineryloversbyfarhan Dear Sir.kon si company ki moter achi hoti .or sir baz dafa onki winding copper ki nahi hoti yh kesay malom krain.original copper ki moter hai ya nahi .apka experience kia kehta hai .please guide us
6 پلیٹ 12 ایمپیر بہترین ہے🎉
Kitny watt ki ???
🎉
Thanks 👍
Thanks
👍👍
Main ne summer Sible pump k Liye inverter lagana he or pump ka torque 22Amp he to or running 11amp to Kitne KW ka inverter lagaon,
Please advise karen😊
Three phase 15 sy 18 Kw wala inverter use kr lain.
Love from India ❤
Kya samay ke saath solar panel ki VOC kam hoti jaati hai ya keval current kam hote jaate hai?
Voc kam hoti
@@textilemachineryloversbyfarhan ok bhai, mere 330w ke poly panels 4 saal puraane ho gaye hai. Panel ke peeche VOC 46.2V likhi hai. Maine 2 panel ki series banani hai to kya mai 90 VOC ka MPPT charge controller laga sakta hu?
Abhi tak PWM charge controller lagaya hua tha.
I want to install solar of 10 KW. How many panels of 585 are required?
10 kw for one motor or different load ??
4 plates battery ko amp kitny provide kry gay charging k liye
Dear apki battery 12 voltage ki hy?
Bhi 14soler 400w wale 5.5 hp ki submersable moter jo ke310 feet per fiting ha pani ka presor kam ha seting bhi thek ha lekin moter saey tareky se nahi chal rahi ol1 ka fault dety ha please renmany farmain ke hamarin platein kum to nahin hain
Dear aapane p2 group mein motor ke Jo Ampire Hain woh kitne feed kiye Hain? Or motor ka load kitna aata hy. Aur yah falt kis time aata hai.
Solar panel 15 hony chahey thy kam az kam. Baqi aap motor ka load check kr k btain . Or Inverter kitny KW ka hy.
Bhai jan agr 1 ton ka inverter A.C chalana ho to kon sa inverter lagana pare ga or kitne solar panel lagain ge..
220 ampere ki tubular battery bhi sath lgani hai..
Please guide
Dear koi b achi company ka 2 kw ka hybrid inverter use krain. 3 solar panel 585 watt ky lga lain. Battery k liay aap pehly btain back up kitny time ka chahey?
@@textilemachineryloversbyfarhan 4 ghnte ka backup chahie
Bhai yeah calculation theek nhi hai.
Mere pass 9 panels 550w k lagy hoi hain aur sirf 1760 watt load dety hai.
Dear peak hours calculation hy. Aap kis time ki baat kr rahy hain jb check kea.
Peak time pr bhi yahi hai sir jee
عملی طور پر چار پلیٹ دس ایمپر دے ممکن نہیں
Dear losses ki waja hy.
Single phase k liye calculation bilkul ghalat hai. Number 1. 4 solar sey tho invt on nahi hotha. Number 2. Mera motor 10 ampere le raha hai. 585 watt k 7 panal hai. Pir b full pressure sey pani nahi detha
Dear aap off grid, on grid, ya hybrid inverter use karain. Invt basically aik three phase inverter hy. Hr jaga lazmi nhi yehi use karna hy.
@@textilemachineryloversbyfarhan offgrid. Vfd invt
Wrong calculation
Ok. But can you share right calculation. Which helps everyone.
زبردست
👍👍👍
زبردست
Thanks 👍
زبردست
Thanks 👍