Equilibration Time in Autoclave

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 เม.ย. 2024
  • Why Air Removal is Required in Autoclave?
    How to calculate F0 Value?
    What is Overkill Cycle in Steam Sterilization?
    #autoclavevalidation
    #Validation
    #Validationinpharma
    #sterilization
    #autoclave
    #aseptic
    #usfda
    #steam
    #bacteria
    #bacterial
    #filter
    #pharmaknowlege
    #sterility
    #qualityassurance
    #quality
    #sterile
    #gmp
    ​⁠

ความคิดเห็น • 10

  • @sumitkumarsharma3914
    @sumitkumarsharma3914 24 วันที่ผ่านมา +1

    Very informative vedio
    Thank you so much sir

  • @nirmalsartana4061
    @nirmalsartana4061 24 วันที่ผ่านมา +1

    Nice information sir

  • @drx.trimbak3126
    @drx.trimbak3126 5 วันที่ผ่านมา +1

    Sir please make video on dwell time

  • @manojpatel6518
    @manojpatel6518 22 วันที่ผ่านมา +1

    Video on Manufacturing and storage tank validation .

  • @saivijay1580
    @saivijay1580 19 วันที่ผ่านมา +1

    Sir thank you very much for your valuable knowledge sharing. Always a pleasure to have your video. Request you to please make a video on "if an injection product is failed to comply with in-process specification which is pertaining to bulk sample, in tests such as pH and Assay and if Finished product specification of same batch is well within acceptance criteria, why can't we release batch without solid identification of root cause for bulk failure as ultimately finished product is sent for administration to pateint.

    • @PHARMAVEN
      @PHARMAVEN  11 วันที่ผ่านมา

      You are right but in practical sense, the batch was failing in process, if there is no laboratory error or if we cannot have another sample to test once lab error is confirmed, then this batch cannot be released

  • @saivijay1580
    @saivijay1580 23 วันที่ผ่านมา +1

    Hi Sir!! Please make a detailed video on difference between collapsed cake vs improper cake vs melt back defects which are blatant defects identified in Lyophilised visual inspection. I would be a great help if expected explanation from your side is along with pictorials.

    • @PHARMAVEN
      @PHARMAVEN  23 วันที่ผ่านมา

      Ok I will make

  • @ravindrajoshi3374
    @ravindrajoshi3374 24 วันที่ผ่านมา +1

    Then sir, what is the difference between 'lag time' and 'equilibrium time'.
    Does equilibrium time related to empty load only,
    Does it mean difference between reference temperature (i.e.inbuilt reference temperature sensor of autoclave) and data logger sensor
    Plz correct me if I am wrong, plz guide me.

    • @PHARMAVEN
      @PHARMAVEN  24 วันที่ผ่านมา +1

      Equilibration time is for loaded chamber
      Book on validation by Agalloco has given below explanation about lag time with reference to Dry heat sterilization
      The heating lag is defined
      as the difference between the time required for the product to reach the minimum required temperature and the time
      required for the sterilizer air to reach the minimum required temperature. A heating lag will be magnified during the maximum load of product (i.e., maximum density or mass).