  • #Cornealhysteresis is essentially a measurement of the shock-absorbing capacity of the eye.
    Learn more about Corneal Hysteresis here:
    david-richardson-md.com/get-yo...
    In medicine “vital signs” are those measurements considered critical to the health of an individual. Common vital signs include temperature, heart rate, breathing rate, and blood pressure. But there are also vital signs of the eye. Visual acuity (e.g., “20/20”) and intraocular pressure (IOP) are two such measurements. For the last twenty years, those with ocular hypertension or glaucoma have had a third vital sign: central corneal thickness (CCT). Corneal thickness can be used (among other things) to estimate how likely someone may be to develop glaucoma. However, a newly discovered measurement has proven to be even more valuable than CCT. This new measurement is called Corneal Hysteresis (“CH”).
    What is Corneal Hysteresis?
    The cornea is the clear (transparent) surface at the front of the eye which focuses light onto the lens inside the eye. It can be thought of as a half-millimeter thick soft contact lens. Like a soft contact lens, it is deformable (“bendy”). Many biological tissues that can be flexed or bent without permanent damage can be described as “viscoelastic”. Viscoelastic tissues absorb some of the force used to deform them like the suspension strut in your car or truck works to absorb the impact of a pothole.
    Corneal hysteresis essentially measures the “shock absorbing” ability of the cornea. The higher the corneal hysteresis, the greater the shock absorbing capacity of the cornea (and perhaps the eye).
    It turns out that a low corneal hysteresis may be predictive of the presence of glaucoma and its progression (worsening over time). In particular, a low corneal hysteresis:
    Can help predict who might develop glaucoma
    Is more common in eyes with glaucoma than otherwise normal eyes
    Is associated with optic nerve and visual field damage in those with glaucoma
    Increases the risk of further damage to the optic nerve
    Increases the risk of progressive visual field loss
    May help in predicting which patients with normal tension glaucoma are more likely to lose vision
    May predict who will respond to certain IOP lowering therapies. For example, a low corneal hysteresis is associated with a greater reduction of IOP after treatment with a class of IOP lowering eye drops known as the prostaglandin analogs (latanoprost being the most common). This also appears to be the case with certain surgical treatments such as selective laser trabeculoplasty (SLT).
    What might be the reason for these associations?
    It’s thought that corneal hysteresis may be similar to whole eye hysteresis. In other words, a low corneal hysteresis may indicate that not only is the cornea unable to adequately deal with changes in force, but the entire eye may be subject to damage from repetitive shocks. The eye suffers from a lot of physical abuse during the day as it is rapidly moved inside the orbit and it is squeezed by the eyelids during blinking.
    Both elevated IOP and fluctuations in IOP can result in damage to the optic nerve. We kind of understand why elevated IOP is bad, but why fluctuating IOP is a risk for glaucoma is less well understood. Hysteresis may provide one answer (if not the answer) to this question. After all, if an eye has a limited ability to absorb shock then it makes sense that fluctuating IOP (essentially mini-shocks) would increase the likelihood of damage to the eye.
    Low central corneal thickness (CCT) measurements are also known to be associated with glaucoma risk. However, corneal hysteresis is more strongly associated with glaucoma presence, risk of progression, and effectiveness of glaucoma treatments than central corneal thickness. Thus, if you could choose only one corneal measurement, you would be wise to choose Corneal Hysteresis over central corneal thickness.
    If you fit into one of the following groups you could benefit from knowing your corneal hysteresis:
    You have someone in your family with glaucoma
    You have diabetes (which can increase your risk of developing glaucoma)
    You are nearsighted (which can increase your risk of developing glaucoma)
    You have elevated eye pressure (“ocular hypertension”)
    You’ve been told that you are a “glaucoma suspect”
    Your doctor is considering placing you on glaucoma medications
    You’ve just started a new glaucoma medication
    You are considering the option of glaucoma surgery
    You have just healed from glaucoma surgery
    Should I Worry if my Corneal Hysteresis Number is Low?
    A low CH number on its own doesn’t mean that glaucoma is inevitable. However, the combination of a low corneal hysteresis and a high IOP is predictive of loss of vision over time. As such, this combination may suggest to your eye doctor that more aggressive lowering of the IOP is needed.

ความคิดเห็น • 13

  • @Userzmxncbv
    @Userzmxncbv ปีที่แล้ว

    Thank you so much for the information. Really appreciated. 😊

  • @tcfbrp8807
    @tcfbrp8807 3 ปีที่แล้ว +1

    Great video doctor! Love to learn new information about what to expect with my disease progression going forward and how to keep things working correctly!

    • @DrDavidDRichardsonMDSanMarino
      @DrDavidDRichardsonMDSanMarino  3 ปีที่แล้ว +1

      Thanks! I've got another half dozen videos in the pipeline. Just trying to get them ready to upload to TH-cam.

  • @raphaeldububuchim6983
    @raphaeldububuchim6983 3 ปีที่แล้ว +1

    Thank you.. I feel really sad because i was told my eye pressure is too high and my corneas are very thick... And I'm a visual artist

  • @mrt605
    @mrt605 2 ปีที่แล้ว

    can u talk about cornia edema 0lease

  • @emperorag555
    @emperorag555 3 ปีที่แล้ว

    I’m very very stressed due my eyes but I already did alot surgery I do smoking what should I do dr?

  • @peterrecce-bz5sk
    @peterrecce-bz5sk 8 หลายเดือนก่อน

    Thank you so much for your video, I never knew about corneal hysteresis. My right eye has a thicker cornea due to past surgeries and trauma, and I was just wondering is that the same as being born with if they cornea as far as the IOP possibly being lower than measured. I have glaucoma in my left eye, and was hoping that, my right eye might be more protected by having a thick cornea even though I wasn’t born with it. Next time I see my eye surgeon, I will definitely ask him about my corneal hysteresis. Thank you so much, Peter.

    • @DrDavidDRichardsonMDSanMarino
      @DrDavidDRichardsonMDSanMarino  6 หลายเดือนก่อน

      Glad you appreciated this video. I wasn't certain this particular topic would have much of an audience, but it is important information that I wanted to share.

  • @samanthahudson7099
    @samanthahudson7099 3 ปีที่แล้ว +1

    Hi Dr. Richardson! How does one test their corneal hysteresis? I've never had my optometrist or glaucoma specialist mention this to me. Also, what is your opinion on how soon a definitive neuroprotector (independent of iop) will be available? 5 years? 10 years? 20+ years? Some great clinical trials in place at the moment. Would love the opinion of a doctor on this. Thank you! :)

    • @DrDavidDRichardsonMDSanMarino
      @DrDavidDRichardsonMDSanMarino  3 ปีที่แล้ว +1

      Hello Samantha,
      Currently there is only one FDA approved device for measuring corneal hysteresis: the Reichert Ocular Response Analyzer. I discuss that in more detail here:
      david-richardson-md.com/get-your-corneal-hysteresis-number-using-the-ocular-response-analyzer-g3/
      With regard to an FDA approved neuroprotectant, an optimistic assessment would be 10 years, realistic 20+ years. Millions have been spent on clinical trials on promising agents in attempts to prove benefit. The problem is that it is just far more difficult to demonstrate neuroprotection than it is IOP reduction. In order to prove an effect it takes a very large and long (expensive) study which very few are willing to attempt.

    • @samanthahudson7099
      @samanthahudson7099 3 ปีที่แล้ว

      @@DrDavidDRichardsonMDSanMarino Thank you for the thorough response, Dr. Richardson!

  • @rajk-qk7ne
    @rajk-qk7ne 2 ปีที่แล้ว

    Can CH be measured looking at IOP changes under corneal shocks....

    • @DrDavidDRichardsonMDSanMarino
      @DrDavidDRichardsonMDSanMarino  2 ปีที่แล้ว

      There is currently only one method of measuring corneal hysteresis which is used by both the Reichert 7CR and Ocular response Analyzer.