Worked fine. I must have changed settings by mistake. Had a weird ticking sound coming from the unit, but I reset the lot, made your change as shown, and all working again.
Once I click on Export Control theres no option for disable nor enable, it actually shows a message "please set under normal status" My question is which status is normal?
Hey , I have 2 problems ; The first is : I didn't find in the settings " control export ", the serie of inverter is : X3 Mic G2 I found it in the catalog but in the settings of inverter it's not found 😢 The second problem in other inverter but the same serie , I did " zero export" but not apply in the reality 😕 it export the energy to grid, where's the problem plz ?😊❤
It will now start to export to the grid, what if i want to limit it from exporting. Your video doesnt solve the fault. You just disabled the export control without addressing the problem.
You need to have an "energy meter( not an electricity meter)" installed in order to limit the export. If you have one you wouldn't be seeing this error and if you would like to limit the export to a specific value you can do so by enabling and giving it a value in the same menu.
Thanks@@mubasher.s, my inverter was powered down for a period and when I repowered it export control became enabled and I don't have a meter installed.
@@desigirl8704 hey, I hope you were able to fix the fault, as I suggested in my last comment it was due to your cicuit breaker eaither faulty or tripped.
Your are wrong my friend. You did not fix the item that causes the fault, you just disable it on the inverter setting but the fault signal that is from the power meter is still present.
The "Export Control" should only be "enabled" if you have an " Energy Meter" installed. So in this case or most cases the Solax inverter resets to "Enable" while the end user doesn't have an actual Meter installed, so this is the only solution to fix the fault. I have clearly explained that you should do it if you don't have an " Energy Meter( not an electcity Meter). Thanks
Worked fine. I must have changed settings by mistake. Had a weird ticking sound coming from the unit, but I reset the lot, made your change as shown, and all working again.
Once I click on Export Control theres no option for disable nor enable, it actually shows a message "please set under normal status"
My question is which status is normal?
Saved me £325. Thank you very much
How do you disable CT Function on SOLAX SK-SU3000E INVERTER?
many thanks....it worked perfectly
Hey , I have 2 problems ;
The first is : I didn't find in the settings " control export ", the serie of inverter is : X3 Mic G2
I found it in the catalog but in the settings of inverter it's not found 😢
The second problem in other inverter but the same serie , I did " zero export" but not apply in the reality 😕 it export the energy to grid, where's the problem plz ?😊❤
Thank you , it worked👍
Great!
It will now start to export to the grid, what if i want to limit it from exporting. Your video doesnt solve the fault. You just disabled the export control without addressing the problem.
You need to have an "energy meter( not an electricity meter)" installed in order to limit the export. If you have one you wouldn't be seeing this error and if you would like to limit the export to a specific value you can do so by enabling and giving it a value in the same menu.
Thanks@@mubasher.s, my inverter was powered down for a period and when I repowered it export control became enabled and I don't have a meter installed.
Thanks, it helped! 👌👍
Hi mine is already disable still not connecting
What does the screen say? Check if the circuit breaker tripped Off in the main switchboard?
@@mubasher.s . It say grid lost fault.
I rang Solax and they’re going to fix it.
@@desigirl8704 hey, I hope you were able to fix the fault, as I suggested in my last comment it was due to your cicuit breaker eaither faulty or tripped.
Nice. Thanx
Aslamualaikum bother what price
Your are wrong my friend. You did not fix the item that causes the fault, you just disable it on the inverter setting but the fault signal that is from the power meter is still present.
The "Export Control" should only be "enabled" if you have an " Energy Meter" installed. So in this case or most cases the Solax inverter resets to "Enable" while the end user doesn't have an actual Meter installed, so this is the only solution to fix the fault. I have clearly explained that you should do it if you don't have an " Energy Meter( not an electcity Meter). Thanks
@@mubasher.s hi, is there a way to limit wattage export to certain value, if I don't have any energy meter? Thanx.
@@XavierLit no, the esport limit can only be controled with an energy meter.
@@mubasher.s could you suggest what meter to buy? I both one from Aliexpress for 100$ and it won't work:(. Inverter doesn't see it
@@mubasher.s hi sir I am facing same problem. From where I can buy energy meter
اس جیسا چاھیے کہاں سے ملے گا
Bro Hindi mo bolo to accha he