HOW TO TEST AN OVERLOAD RELAY

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 พ.ย. 2024

ความคิดเห็น • 94

  • @LuisGonzalez-qh3tm
    @LuisGonzalez-qh3tm 3 ปีที่แล้ว +13

    Wow, everything I needed to know quickly. Thanks brother!

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      You are welcome bro. Happy I could help.

  • @joselopez8484
    @joselopez8484 ปีที่แล้ว +1

    Nice and simple. Thanks for sharing.

  • @katun1368
    @katun1368 4 ปีที่แล้ว +5

    Short and simple and good information.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for the positive feedback. More great content coming soon.

  • @TradeGod
    @TradeGod ปีที่แล้ว +1

    Nice lesson

  • @SombraLocs
    @SombraLocs 3 ปีที่แล้ว +4

    Great video! Short and easy to understand.

  • @joehernandez4678
    @joehernandez4678 ปีที่แล้ว

    Thank you very informational and straight to the point

    • @synectum640
      @synectum640  ปีที่แล้ว

      You're welcome! Thank you.

  • @kiritvara257
    @kiritvara257 2 ปีที่แล้ว

    that really help me with lathe machine. thank bro.

  • @Kayellt
    @Kayellt ปีที่แล้ว

    You the best. Thanks!

  • @pincermovement72
    @pincermovement72 ปีที่แล้ว

    Very clear , well done

    • @synectum640
      @synectum640  ปีที่แล้ว

      Thanks for the feedback.

  • @fb420smokersclub
    @fb420smokersclub ปีที่แล้ว

    Thanks for the video, liked and subscribed. 🙂

  • @pixedust1689
    @pixedust1689 2 ปีที่แล้ว

    Great video. Thanks

  • @browneye653
    @browneye653 3 ปีที่แล้ว

    Sounds like a Jamaican. Good video breda

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      Yea mon Jamaican. Much respect.

  • @liamcollins8692
    @liamcollins8692 4 ปีที่แล้ว +2

    Well explained thank you.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for the feedback Liam. You are welcome.

  • @marcusseger2583
    @marcusseger2583 4 ปีที่แล้ว +1

    very informative and helpful

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for your feedback.

  • @moisessalazar2417
    @moisessalazar2417 2 ปีที่แล้ว

    Great explanation

  • @juniorross3396
    @juniorross3396 4 ปีที่แล้ว +3

    Thanks for this informative video. Can you tell me if a relay like this can be used to protect a single phase 220v motor from overheating?

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for the feedback. Any motor being controlled it is recommended to use an overload for protection. If your motor is overheating it is probably overworked ( having too big of a load). While this overload will protect you from over current which is a common factor for overheating, you might want to upsize you motor to match the load it is connected to.

    • @juniorross3396
      @juniorross3396 4 ปีที่แล้ว +1

      @@synectum640 Thanks for your fast reply. It's not that I'm having a problem with overheating but I want to prevent any potential overheating problems. I have assembled a diy meat grinder and only use it for meat but I want to grind bones as well. I've only recently learned about overload protection and want to protect the motor in the event that it gets stuck on a hard bone.
      If It's not a problem for you can you recommend a suitable overload relay for my current set up? The motor is 2.2KW 220V.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      What is the FLA on the nameplate of the motor? Should be around 10 -13 amps.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Eaton XT series electronic overload relay, 4-20 A adjustable. Model type XTOE020CCSS.

    • @juniorross3396
      @juniorross3396 4 ปีที่แล้ว

      The motor says 2.2 kw 220v and 7.5 A All of the words are in Chinese so I'm not sure if the FLA is 7.5 A. As for implementing overload protection this might be a dumb question but how do the connections go? Will it just be as simple as running the power source for the motor to L1 and L2 and then connecting T1 and T2 to the motor?

  • @seanoeung4648
    @seanoeung4648 10 หลายเดือนก่อน

    Thank you very much.

  • @lancec6342
    @lancec6342 2 ปีที่แล้ว

    thanks for the video

  • @victoresuku73
    @victoresuku73 4 ปีที่แล้ว +1

    Very educating.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for the feedback.

  • @douglee5715
    @douglee5715 2 ปีที่แล้ว +1

    Good video. Nice glove. Do you have a link for them?

    • @synectum640
      @synectum640  2 ปีที่แล้ว

      Thank you. It's called microflex onyx. Many different suppliers for them online.

  • @walters24051
    @walters24051 4 ปีที่แล้ว +1

    Good video

    • @synectum640
      @synectum640  4 ปีที่แล้ว +1

      Thank you for your feedback!

  • @khalilhenry6300
    @khalilhenry6300 4 ปีที่แล้ว

    Very informative video

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Thank you for the positive feedback.

  • @williamnickolas4288
    @williamnickolas4288 2 ปีที่แล้ว +1

    Very good

  • @larrybassik2768
    @larrybassik2768 3 ปีที่แล้ว

    That Easy to Understand

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      Thanks for the feedback.

  • @Le_vis254
    @Le_vis254 9 หลายเดือนก่อน

    Great video sir. Does it mean that, even if power flows through the o/l relay, the overload's nc and no only change states in one condition; when the overload relay trips?

    • @synectum640
      @synectum640  9 หลายเดือนก่อน +1

      That is correct.

    • @Le_vis254
      @Le_vis254 9 หลายเดือนก่อน

      @@synectum640 thanks sir!

  • @robertoellis225
    @robertoellis225 4 ปีที่แล้ว

    Good tutorial Teacha.

    • @synectum640
      @synectum640  4 ปีที่แล้ว

      Really appreciate the feedback.

  • @michaelcostello6991
    @michaelcostello6991 ปีที่แล้ว +1

    What is the red stop button for ? Is it the same thing as the test

  • @RideWithAnthony
    @RideWithAnthony 2 ปีที่แล้ว

    My motor is on all and won’t shut off when it supposed to would this be a solution ?

    • @synectum640
      @synectum640  2 ปีที่แล้ว +1

      I belive you have a controls issue. You on/off or start/stop seems to be not working and hence keeping your contactor closed. I would start there and work my way down. Thank you.

  • @jefrysukma8208
    @jefrysukma8208 3 ปีที่แล้ว +1

    Sorry for my English, I'm Indonesian.
    Is it possible that Thermal Overload Relay not tripped above the set point after determined time achieve?
    Like: Set 50A, Class 10. The current condition is already above 50A - let say 60A, for more than 20 seconds, and the Relay still not tripped.
    What part of the Thermal Overload Relay is broken?

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      First off for any thermal overload malfunction I would advise you to check the wiring first. Ensure your NC contact is wired in properly to break the circuit in a tripped state. Another failure point is the thermal bi metallic strip. Based on your question however in order to properly set and size the adjustable class 10 overload you must first get your FLA rating from your motor nameplate and use your 125% x FLA if you have a SF of 1.15 to get your max load current. With those values you can properly determine if your overload should have tripped based on your calculations. If possible state the voltage level, FLA, SF, and also the model overload you are using so we can carefully diagnose. Thank you.

  • @bigjoe161
    @bigjoe161 3 ปีที่แล้ว

    Do more videos 📹 please

  • @taurussilver3053
    @taurussilver3053 3 ปีที่แล้ว +1

    What is that stop button for ?

    • @synectum640
      @synectum640  3 ปีที่แล้ว +1

      Good day. It is used to manually open the N/C contact on the overload.

  • @corydarpino9082
    @corydarpino9082 ปีที่แล้ว

    I have continuity when power is on but not when power is off I have 3 of these in a row and the least one doesn’t have contenty when it’s on or off

    • @synectum640
      @synectum640  ปีที่แล้ว

      Seems you might have a tripped OL. Remove power from circuit, reset and test for continuity. If you do, check circuit for a potential short.

  • @shahmi09
    @shahmi09 3 ปีที่แล้ว

    So what I understand is that the NC contact (terminal 95 & 96) will break open during an overload... However, will there be continuity between terminal L3 & T3 when an overload occurs?

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      Yes that is correct. 95 - 95 would be wired in series with coil wiring of the contactor supplying the 3phase power. When it trips it opens the coil circuit, deenergizes the contactor and opens the line to load contacts which prevents current from flowing to the overload terminals IDEALLY.

    • @shahmi09
      @shahmi09 3 ปีที่แล้ว +1

      ​@@synectum640 Thank you for the confirmation and for the great video!

    • @synectum640
      @synectum640  3 ปีที่แล้ว

      You're welcome and thanks for the feedback.

  • @jordanjohnson2685
    @jordanjohnson2685 2 ปีที่แล้ว +1

    So if power is applied do you have 0 volts on your NC and 24 volts on your NO then if it does trip, will you have 24 on your NC breaking it and 0 on your NO? Or am I wrong

    • @synectum640
      @synectum640  2 ปีที่แล้ว +1

      You usually only wire your hot going through your NC contact so it depends on where your reference is that determines the voltage read at your NC contact. If your measuring across the NC and NO contacts then yes. The coil if it is a magnetic or electronic will also affect these readings for your NC contacts.

  • @omarikram5238
    @omarikram5238 3 ปีที่แล้ว

    Connectivity test is good but how are we going to test that whether the relay tripping coil really works when an overload current pass through it.

    • @synectum640
      @synectum640  3 ปีที่แล้ว +1

      The most you can do are the test outlined in the video. Only additional test is to actually supply the overloaded current to see if it trips (I WOULD NOT ADVISE THIS).

  • @nitinkale560
    @nitinkale560 6 หลายเดือนก่อน

    So this is a faulty overload relay.😊

    • @synectum640
      @synectum640  6 หลายเดือนก่อน

      Yes, it is. From my scrap pile.

    • @nitinkale560
      @nitinkale560 6 หลายเดือนก่อน

      @@synectum640 ok, Sir. Any possibility of opening it and try for repair?

    • @synectum640
      @synectum640  6 หลายเดือนก่อน

      For reliability issues I wouldn't. Being such an important safety device, I would replace.

    • @nitinkale560
      @nitinkale560 6 หลายเดือนก่อน

      ​@@synectum640Right, Sir. 😊

  • @jasonamosco318
    @jasonamosco318 3 ปีที่แล้ว

    I have question why L1 and T1 reads OL, also L2 and T2 reads OL but why L3 and T3 is shorted. I don't understand

    • @synectum640
      @synectum640  3 ปีที่แล้ว +1

      Good day. For an overload there should always be continuity between ( L1 - T1) , ( L2- T2) and (L3 - T3) in a normal operating overload device. In my example we experienced "OL" conditions between our first two line to load contact legs hence why that overload was a damaged one. NOTE : It's different from a contactor where you'd usually have an OL condition between your line and load terminals until the coil is energized.

    • @jasonamosco318
      @jasonamosco318 3 ปีที่แล้ว +1

      @@synectum640 Thank you and I now got it. :)

    • @synectum640
      @synectum640  3 ปีที่แล้ว +1

      You're welcome. Happy to help.

  • @Dameshame
    @Dameshame ปีที่แล้ว

    Walter?

    • @synectum640
      @synectum640  ปีที่แล้ว

      If you're asking if I am Walter, then no.

  • @seanoeung4648
    @seanoeung4648 2 หลายเดือนก่อน +1

    Thank you very much.