Beechcroft Model Railway - #68. Peco Crossings - Safe To Use??

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 พ.ย. 2024

ความคิดเห็น • 37

  • @darrenfawkner2018
    @darrenfawkner2018 วันที่ผ่านมา +1

    Fantastic update cant wait to see the next one 😀

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Thanks very much. I just hope it works out ok!! 😂

  • @ireneforward8115
    @ireneforward8115 2 วันที่ผ่านมา +6

    The short crossing should work . Just isolate it completely and give it independent power , switching polarity according to the direction of travel .

    • @WILLMERE.
      @WILLMERE. 11 ชั่วโมงที่ผ่านมา +1

      This is the method that I used, manually switched, which can cause issues if you are not on your toes. Must get around to fitting auto switching one day.
      One of the biggest problems is older loco’s and stock having wider wheel rims that bridge across the frog rails, that’s why I have decided to move on some loco’s and not bother converting them to DCC.
      What ever method you use, it’s got to be better than mine where one track has to go into a head shunt to gain access to the helix.
      Keep up the good work. Bill.

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Thanks Bill, very useful as always 👍

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Thank you 👍

  • @forrestrobin2712
    @forrestrobin2712 2 วันที่ผ่านมา +4

    I used to be indecisive, but now ? I’m not so sure 🤔
    Nice layout!

  • @johnstephens649
    @johnstephens649 2 วันที่ผ่านมา +1

    Glad you are going for the sweeping junction away from the station and not just because I was one of those who suggested it! You have enough going on with the station throat already and is a cleaner solution. I would still add a cross-over after the branch joins the outer lower loop so you can get trains from the inner loop onto the branch and thereby the helix etc. Without a crossover, the inner loop is somewhat isolated apart from the crossing at the end of the station which wouldn’t work in the same way.

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Thanks very much for your suggestions. Really helpful 👍

  • @Sandlingjunction
    @Sandlingjunction วันที่ผ่านมา +1

    Hi there, in answer to some of your worries, on my larger old Sandling Junction layout, I had a short cross, and it never failed, I also had 5 long crosses without issues. I employed many curve points on that layout and reused them in the new Sandling Junction Layout. Hope that helps a little, cheers Paul

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Hi Paul. That’s really good to know. Thank you 👍. Keep up the great work on the new Sandling Junction. Enjoying watching your progress. Cheers, Andy

  • @timobluetreemodels352
    @timobluetreemodels352 2 วันที่ผ่านมา +1

    Hi, I follow your video with great interest, very good and great work! In answer to your concerns on the crossing junction. I use the larger ones and found the best answer is to add some protection to the static frog areas to correct for any shorts. I use a black nail varnish called “concrete” so far I haven’t had to revisit for any further applications. Running great for six years! As to the three way, they are a sod to power but never had a running issue. Just make sure the point is dead flat. Hope that helps a bit?
    Keep up the great videos.

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Hi. That’s great to know. Thanks very much for taking the time to share your experiences. Really appreciated, Andy 👍

  • @bulleidboy1
    @bulleidboy1 2 วันที่ผ่านมา +1

    I have two Peco Code 75 3-way asymmetric points powered by Cobalt iP motors, and they have been working faultlessly for about ten years.

  • @chugwaterjack4458
    @chugwaterjack4458 ชั่วโมงที่ผ่านมา

    I you are having any shorting issues in points or crossings, be very aggressive with your back-to-backs. I have a Bachmann Deltic that couldn't through a Peco long point (BullHead) without shorting. I checked the rail gauges throughout, adjusted a little on the outer rails, and still had the problem. Finally, I checked the back-to-back, and some of the axles were "close" but still refused my DCCConnection gauge. With a bit of forcing - and ugly process that - I got all six axles in compliance, and the shorting went away.
    I have also found that it is absolutely critical that any point MUST be of the same slope across throughout. That means dead level if the approach tracks are level, or carrying exactly the same super-elevation as the approaches.
    Also, if I were starting over, I would NOT go to bullhead; it is just too touchy to work with, and the commonly available 36" flex track has a sleeper section much too thin to be able to ballast worth a darn. My hidden tracks are all Code 83. and all work just fine.

  • @anfieldroadlayoutintheloft5204
    @anfieldroadlayoutintheloft5204 2 วันที่ผ่านมา

    great update on layout thanks for share

  • @steveclark7971
    @steveclark7971 2 วันที่ผ่านมา +2

    Personally I would stay away from 3 way points I had nothing but agro with them! Shorting out derailments in the end got rid of them and worked something else out.

  • @alanwagstaff16
    @alanwagstaff16 2 วันที่ผ่านมา +1

    I have used nail varnish to stop my shorts . It takes a second leave it 20mins and your good to go

  • @garyhodge7861
    @garyhodge7861 วันที่ผ่านมา +1

    I read that model railways have become too expensive, but I built one anyway! I've had no problems with short crossings or 3 way points (code 100, analogue) but the double slips have caused a few issues. I find it ironic that you have a double slip but are concerned about the short crossing and 3 way.

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Thanks. I’ve no issues with a 3 way point? I already have one on the layout! With regards the short crossing, I’m only asking as there are several forum discussions where they have caused shorting issues 👍

  • @going2thedogs
    @going2thedogs วันที่ผ่านมา +1

    Looks like someone is gonna be busy…. Exciting.

  • @johncresswell9843
    @johncresswell9843 2 วันที่ผ่านมา +1

    Hi, I actually used a Hornby crossover which seems to be better
    Regards John

  • @kelvinVAUGHAN
    @kelvinVAUGHAN วันที่ผ่านมา +1

    Can you remove the right supporting leg whilst you get helix in and then replace it.

  • @kelvinVAUGHAN
    @kelvinVAUGHAN วันที่ผ่านมา

    what make is your station overall roof? As my club is looking for one on it's main layout.

    • @Grandadstrainroom-pn3tt
      @Grandadstrainroom-pn3tt  4 ชั่วโมงที่ผ่านมา

      Hi. It’s the Peco ‘Overall Roof’ kit 👍

  • @colinclegg7911
    @colinclegg7911 2 วันที่ผ่านมา +1

    Three way point could prove unreliable