  • @jeddmerton6877
    @jeddmerton6877 2 ปีที่แล้ว +18

    For those curious about the lack of urgency in this drill…
    This is the fire service playbook used for training and drills only. It emphasises control and efficiency, not speed.
    In a live operation, a hose reel (primarily used as a covering jet) would be deployed immediately as it already has a fed water supply, whilst the rest of the crew will run out a lay flat or two and find a water source (hydrant or open source). Generally 45s and 70s aren’t required as often as people think. Two hose reels will often do the job.

    • @greigshearer5614
      @greigshearer5614 ปีที่แล้ว +1

      Never look down whilst connecting.. keep your head up.

    • @romanlyssenko5618
      @romanlyssenko5618 2 หลายเดือนก่อน

      ​@greigshearer5614 why?

  • @user-ok4cd7vi8q
    @user-ok4cd7vi8q ปีที่แล้ว +2

    Браво от България! Наистина натренирани!

  • @firekev4525
    @firekev4525 2 ปีที่แล้ว

    Brings back memories when i did my recruit training at Reigate.. 38yrs ago.😱

  • @lu8201
    @lu8201 5 ปีที่แล้ว +6

    Respect to the fire women and men!

  • @hollow34
    @hollow34 4 ปีที่แล้ว +8

    Thanks for this and thanks for knocking off the music eventually, wanted to know what they were shouting.

    • @Tokyo-c
      @Tokyo-c 3 ปีที่แล้ว

      Hollow Hat for water

  • @tafadzwachikweye9461
    @tafadzwachikweye9461 ปีที่แล้ว +1

    British Standard FF, well executed

  • @ralv10
    @ralv10 ปีที่แล้ว +2

    In Poland we have in my opinion better system for drills. We use water splitter and if we want to extend or short the line we just give command to each other without a words. i.e
    Nozzle operator when ready raises arm up and show "forward" . It means "Im ready, open water supply" we say ( water ahead)
    Arm waving from side to side means water STOP.
    Arm raises and fall like train whistle or horn motion (upwards), mean increase water pressure,
    the same but Downwards = decrease water pressure

    • @eastofenglandemergencyspotting
      @eastofenglandemergencyspotting 10 หลายเดือนก่อน

      We also use that system here, the arm signals are more used than shouting out this is just training, if we are at a point where the pump operator can't see but they can hear us shout then we would shout.

  • @c.l.ofilms7206
    @c.l.ofilms7206 2 ปีที่แล้ว +2

    At 4:00 it should water off delivery 1 I think

  • @robertlawson8572
    @robertlawson8572 5 ปีที่แล้ว +2

    Hi, you guys deployed this hose "conventionally" (as I was taught in the armed services) yet in your other video, the "Dutch Roll" or "Roll on a Bight" was used. Why the difference? I did note the other hose was a smaller diameter... This method, with a layflat hose, we were taught was fastest, and subjected the hose to less abrasion during deployment. I know times change, but generally there's a reason for doing things a particular way, I just wondered...
    Keep up the good work, anyway, we can't do without you.

    • @scrappy673
      @scrappy673 4 ปีที่แล้ว +2

      A Dutch roll is good for deployment in a more open space environment. These single rolls are more used for bowling and navigating tight spaces. However though this is pretty slow compared to a real fire ground.

    • @benlanchester8645
      @benlanchester8645 4 ปีที่แล้ว +4

      This is purely demonstration real life these guys would be flat out

    • @TheDrummie1
      @TheDrummie1 3 ปีที่แล้ว +3

      Dutch roll is usually deployed as the last line of hose at the entrance of the building, and allows the FFs to have a "bight" of hose as they enter.

    • @challasaraswathi5072
      @challasaraswathi5072 ปีที่แล้ว

      Firefighter uniform cost, gloves vendor/ mfg contact no please

  • @KL-jr5ip
    @KL-jr5ip ปีที่แล้ว

    Are there switches in the pump to switch when it switches from operates with water from the tank to from water connect from hydrant, can both be connected cocurrently?

    • @scooby1992
      @scooby1992 ปีที่แล้ว

      As far as I know you can only use on or the other . You just close the tank valve if you want to use the pressure fed supply .

  • @seanmahoney2671
    @seanmahoney2671 ปีที่แล้ว +1

    It really is interesting the differences. The hose connections are very different from the US (no shock, but those are kind of cool quick connect things), my agency has never allowed running on the fire ground just walk with a mission/urgency (too easy to injure self accidentally), and nozzleman is holding the kickback of the hose with his arms instead of into his hip or the ground. Your arms will tire a LOT faster if you do it that way. Pressure on the line seems pretty low though, so maybe not a big deal... but then you wouldn't need backers either.

    • @josh35639
      @josh35639 2 หลายเดือนก่อน

      All fire service equipment uses instantaneous couplings

    • @almerindaromeira8352
      @almerindaromeira8352 7 วันที่ผ่านมา

      Yeah, they all say no running but when you are understaffed, have quite a big job at hands and the public is watching everything goes.

    • @seanmahoney2671
      @seanmahoney2671 6 วันที่ผ่านมา

      @@almerindaromeira8352 Until you are picking up someone who hurt themselves on scene because they were running and not only did you take time away to deal with them, you are down a guy.

    • @almerindaromeira8352
      @almerindaromeira8352 5 วันที่ผ่านมา

      @@seanmahoney2671don't join the fire service if you can't run.
      You can trip and fall by walking too, is not like jogging is going to exponentially increase the risk

  • @danielfowles-ti1oe
    @danielfowles-ti1oe ปีที่แล้ว

    If 999 calls comes in about RTC you need get the in 2 miss ok

  • @nitin77776
    @nitin77776 3 ปีที่แล้ว +6

    One of the most funny drill i ever seen

  • @markbaird9054
    @markbaird9054 5 ปีที่แล้ว +3

    Do firefighters do this at real fires?

    • @b0ris360
      @b0ris360 4 ปีที่แล้ว +9

      Nope

    • @scrappy673
      @scrappy673 4 ปีที่แล้ว +10

      Nope... such wasted time pulling out the hose and sending runners.. just throw ur hand up and shout water on and bowl your hoses and they'd be set...

    • @nitin77776
      @nitin77776 3 ปีที่แล้ว

      Never

    • @niksvab7148
      @niksvab7148 3 ปีที่แล้ว

      We never do it like that

    • @jamesbrough8949
      @jamesbrough8949 2 ปีที่แล้ว

      @@niksvab7148 is it just for the camera or are the drills actually carried out like this

  • @Rhaman68
    @Rhaman68 3 ปีที่แล้ว +1

    What’s with the extended arm “salute” thing? Seems too high a level of military style routine that chews up time.

    • @boybish27
      @boybish27 2 ปีที่แล้ว +6

      It's not a salute, they're called 'pumping signals'. They are used when it's noisy on a fire and the pump operator can't hear the person on the hose. An arm straight up in the air is 'water on' so the pump operator gives water. The arm out to the side then down is 'knock off' so the pump operator turns that delivery off. An arm up and making a pulling down motion (like you'd signal to a truck driver to sound their horn) means increase pressure by one bar. One arm straight up and one out to the side in an 'L' shape means reduce pressure by one bar.

  • @markbaird4147
    @markbaird4147 4 ปีที่แล้ว +3

    I would have thought fire hose drills would need to be carried out as fast as possible to ensure firefighters could do it under pressure since fires are not slow.

  • @c.l.ofilms7206
    @c.l.ofilms7206 ปีที่แล้ว

    Line 1 or is it delivery 1

    • @scooby1992
      @scooby1992 ปีที่แล้ว +1

      Line one is the hose . Delivery one is the outlet you connect the hose to on the pump . Generally numbered from left to right .

  • @shanestamball1886
    @shanestamball1886 ปีที่แล้ว

    After the video released by this channel (How UK Fire Fighters put out a house fire) and turned the comments off. Truly shows the LUNACY of who ever is approving the training and tactics of this fire service. In the USA if I were to perform a Vent Enter Search then return to the window with or without a victim, and the ladder was moved outta reach. Someone would be going to hospital and fired. Completely LUNACY. I'm curious how many people die a year in UK house fires???

    • @scooby1992
      @scooby1992 ปีที่แล้ว

      I am in the UK , but not in this Brigade and I watched the video you talked about and I understand what you mean . Using the harness and lowering the casualty down looked much safer than doing a carry down , but as you say it meant re positioning the ladder and extending it and pitching it higher up to in corporate the pulley system , BUT like you I also thought how the hell do the BA Team get out of the building quickly if something has gone wrong and their ladder isnt there .? I also noticed that comments were not allowed on that video . If possible I wonder if a second ladder could have been pitched at the side of the first so that at no point were the BA Team left without an escape route . It may be that as this was for demonstration purposes at a ' safe ' venue that the video was just to show us how they carry out the rescue .

  • @nitin77776
    @nitin77776 3 ปีที่แล้ว +8

    Im also the firefighter but they make me laugh

  • @luizalmeida9399
    @luizalmeida9399 ปีที่แล้ว +1

    Rennen rig 2010 mattel hot wheels comentários 58

  • @samryuthe2nd67
    @samryuthe2nd67 8 หลายเดือนก่อน

    Your branck look hard to connect

  • @MsBeverly13
    @MsBeverly13 ปีที่แล้ว

    The other day a fire truck took off for a fire after leaving the grocery store for food I presume and the hose flew out the truck and kept releasing as they were flying down the road. It laid stretched out on the road while they kept driving. I tried to catch and tell them but they couldn’t hear nor see me. Finally I turned off and said screw it… how dumb can they be. They need something updated to tell them their hose is not secure in those old ass trucks if they’re not going to make sure they check check and recheck things like that.

  • @tylerdevine332
    @tylerdevine332 หลายเดือนก่อน

    Not how you should hold a fire hose

  • @bethanymuldowney3335
    @bethanymuldowney3335 3 ปีที่แล้ว

    A

  • @muryantoarc1808
    @muryantoarc1808 ปีที่แล้ว

    Ho

  • @rajdeepsinh5076
    @rajdeepsinh5076 8 หลายเดือนก่อน

    Worng drill im Indian firefighters

  • @Chris-hy6jy
    @Chris-hy6jy 4 ปีที่แล้ว +2

    Wow! That's really embarrassing. I hope our firefighters don't do any of this regimented textbook nonsense when fighting a real fire 🤦‍♂️

    • @TheDrummie1
      @TheDrummie1 3 ปีที่แล้ว +21

      These are drills from the fire service drill book and they do this "regimented" style right through training this gets the team going as each member has a number and a role, by the time they are graduating they will know each role and will be proficient in each of these. At the start its not about speed its about getting to know how to use the equiipment correctly, too much speed at the start of training can cause unnecessary injury and mistakes. When they get out the stations they will continue training with their colleagues, but the basics will all be there. If you observe fully trained FFs at a call the jump into action without "regimented drill" and this is because they have been trained using these long established well tried methods.

    • @Blood-pack
      @Blood-pack 3 ปีที่แล้ว +3

      TheDrummie1 couldn’t have said it better myself

    • @yjwrangler7819
      @yjwrangler7819 2 ปีที่แล้ว +1

      You haven't a clue what you're even looking at.

    • @Chris-hy6jy
      @Chris-hy6jy 2 ปีที่แล้ว

      @@yjwrangler7819 who me? Wrong.

    • @scooby1992
      @scooby1992 ปีที่แล้ว

      No they dont . When you learn you learn by drilling like this to get used to how you do it . When they were running the hose out one firefighter who has run out their hose kneels down to accept the next firefighter's hose ( as shown in the first drill ). At a real job you might be doing this task by yourself if the rest of the crew is busy .

  • @alexpalacio2695
    @alexpalacio2695 3 ปีที่แล้ว +4

    YIKES LMAO lots things need to be changed in European firefighting and I mean LOTS

    • @josephmalsom
      @josephmalsom ปีที่แล้ว +12

      A year on and we're all still waiting for your suggestions kid

    • @shanestamball1886
      @shanestamball1886 ปีที่แล้ว

      @@josephmalsom I just watched the video that has comments turned off, (How UK Fire Fighters put out house fire)
      Beyond scratching my head in disbelief, a confirmed victim, and nearly 5min before making entry, then place the ladder out of there reach for some silly contraption. Stand around and listen to some white hat to explain to you how he wants you to perform a Job, not any job but your own Job,,?!$#-+&()!!?!! WTF? STFU! you have a confirm entrapment!! Maybe he should train the pump operator during the fire. There isn't anything proper about any of this.

  • @Tokyo-c
    @Tokyo-c 3 ปีที่แล้ว +1

    What kind of hekin hose rolling is that and that’s that fucking weak nozzle I am a firefighter in German and what’s that weak nozzle

    • @Tokyo-c
      @Tokyo-c 3 ปีที่แล้ว

      You need to skit the fire hose

    • @Tokyo-c
      @Tokyo-c 3 ปีที่แล้ว

      And they could just tucking scream

    • @lewis523
      @lewis523 2 ปีที่แล้ว +1

      They are doing it slowly purely for demonstration purposes. If they did it fast, people wouldn't have a clue whats going on

    • @josephmalsom
      @josephmalsom ปีที่แล้ว +3

      I wasn't aware that an akron475l was a weak branch I mean it'll drain a pump in about 4mins, at 3 bar it won't be throwing far

  • @adamant8235
    @adamant8235 9 หลายเดือนก่อน

    Ba hahahahahahahah 🤣🤣🤣 only the Brit’s could do something so funny 🤣🤣🙄🙄